| 1 | Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed. |
| 2 | Excavation in trenches, n.exc. 1.5m wide and n.exc. 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. |
| 3 | M & L for cement concrete type D2, 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 4 | M & L for RCC (M-25 design mix) using 20mm graded aggregate as in foundation including rafts, footings, fdn beams, plinth beam, base for columns etc complete all as specified and directed. |
| 5 | All as per above serial item No 04 but in columns, pillars, piers, posts and struts etc complete all as specified and directed. |
| 6 | All as per above serial item No 04 but in roof beams and lintels over 1.5 m Span etc complete all as specified and directed. |
| 7 | All as per above serial item No 04 but concrete for chajjas complete all as specified and directed. |
| 8 | M & L for RCC (M-25 design mix) using 20mm graded aggregate as in Slab supported on walls beams on columns in floors roofs landings, bolocony, canopy, deck slab and in shelves and the like etc complete all as specified and directed. |
| 9 | Supply only polymer compound for water proofing liquid complete all as specifed |
| 10 | M & L for Rough finished surfaces of concrete flat for form work to sides of footing, fdn and plinth beams complete all as specified and directed. |
| 11 | All as per above serial item No 10 but for columns. |
| 12 | All as per above serial item No 10 but for sides and soffits of roof beams and lintels etc |
| 13 | All as per above serial item No 10 but for suspended chajjas |
| 14 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending pirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 15 | M & L for Mild steel TMT bars 5 mm dia and over upto and including 10mm dia in stirrups, spaces and binders complete all as specified and directed. |
| 16 | M & L for form work to sides and soffits of suspended slabs such as roof slabs, landings and similar work not exc 200mm thick (horizontal or slopping) for flat fair finished surfaces complete all as specified and directed. |
| 17 | Returning filling including spreading leveling watering and well ramming in layers n.exc 25 cm in thickness complete all as specified and directed. |
| 18 | Removal of excavated soil to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point as directed. |
| 19 | M&L for hardcore of broken stone or boulder of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 20 | M & L for plain cement concrete 1:4:8 type D-2 (75mm thick) using 40mm graded aggregate as in sub base complete all as specified and directed |
| 21 | M & L for 20mm thick screed bed or bedding layer in CM 1:6 for laying floor finish and. Complete all as specified and directed by Engineer-in-Charge. |
| 22 | M & L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the sahde of the slab including rubbing and polishing complete all as specified and directed |
| 23 | M & L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the sahde of the tiles including laid 15mm thick screed bed in CM 1:4 , rubbing and polishing complete all as specified and directed |
| 24 | M & L for cement concrete type C1 1:3:6 (20mm graded aggregate) 75mm thick as in plinth protection complete all as specified and directed.. |
| 25 | M & L for pre-cast cement concrete block Type C-1 1:3:6, 20 mm graded agg masonry with solid blocks exc. 10 cm in width and setting in mortar 1:6 , complete all as specified and directed. |
| 26 | M & L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed. |
| 27 | M&L for rendering 15mm thick cement plaster on fair faces of brick work on concrete surfaces in CM (1:4) rendering to be finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 28 | M&L for preparation of new plastered surface of walls and appying two coats of cement based paint with priming plastered and other surfaces with alkali resetant priming coat complete all as specifed and directed |
| 29 | M & L for preparation of new plastered surface of walls and applying three coat of white wash complete all as specified and directed. |
| 30 | M & L for preparation of new plastered surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 31 | M & L preparation new or previously untreates steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed. |
| 32 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails braces etc complete drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (running rails guides etc) (Fe-410W Gde E-250 quality A) and hanging also fastening and fixing complete |
| 33 | S & F steel windows or ventilators, fixed type, with glazing bars complete all as specified and directed. |
| 34 | S & F Steel window with side hung shutters inclduing projecting type hinges with steel handle and steel peg stay complete with glazing bars, dovetailed or welded etc complete all as specified. |
| 35 | S & F for sheet glass 4mm thick ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane (ISI Marked) complete all as specified and directed by Engr-in-Charge |
| 36 | S & F framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars: barred iron doors, ladders framed balusters walkways railings frame work or water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specifed |
| 37 | M&L of water proofing treatment to non-accessible roof slab with APP based modified polymeric membrance as per manufacture's instruction with following courses of description below:(a) Applying a priming coat of bituminious primer @ 0.30 Kg/Sqm, till the surface is properly impregnated.(b) Providing APP 5 layer polymeric membrance minimum weighing 3.00 Kg/Sqm and minimum 3mm thick reinforced with plyster non-woven fabric (weight not less than 150gms/Sqm) centre core, laid on primed surface by forced application as per the manufacture's instruction with side over lap of 75mm and end ovelap of 100mm . All overlap joints hsall be sealed throughly by thermo fusing both the menbrane layer (torching overlap by propance or butane gas torch) and sealing it with the help of hot trowel. The overlap joints shall be made as a monolithic laer (c) Apply two coat of bituminous aluminium paint@ 0.20Kg/Sqm over APP membrance.Note :1. The work of water proffing treatment shall be got executed through authorised applicator of the manufactureer only and 10 year company back warranty to be submitted by contractor.2. The work is requried to be carried out at non-accessible roof slab for double storeyed. The contractor shall make arrangement of scaffolding , safety and security of workers and arrangement for approach to roof. The rtes quoted shall deemed to be inclulded for these items |
| 38 | Excavation over area not exceeding 1.5 metre deep and getting out in hard/dense soil, complete all as specified and directed. |
| 39 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation etc, complete all as specified & directed |
| 40 | M&L for precast cement concrete block masonry with solid block exc 10 cms in width made with PCC 1:3:6 type C-1 (using 20 mm graded aggregate) and set in CM 1:6 complete all as specified and directed. |
| 41 | M&L 12 mm thick rendering on fair faces of brick work or concrete surface in cm 1:6 to be finished even and smooth without using extra cement complete all as specified and directed. |
| 42 | M&L 15 mm thick cement plaster in CM 1:4 on brick work or concrete surface other than fair face or brick work and finished surface even and smooth without using extra cement complete all as specified and directed. |
| 43 | M&L for preparation of newly plastered surfaces of walls including cornices, pillasters etc, and applying two coats of oil emulsion distemper over and including one coat of chalk whiting preparatory to distempering complete all as specified and directed. |
| 44 | M&L for 75mm thick in PCC 1:3:6 type C-1 as in plinth protection surface finished even and smooth without using extra cement comlete all as specified and directed |
| 45 | M&L Glazed ceramic white colour tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 15 mm thick rendering in CM 1:4 complete all as specified and directed |
| 46 | M&L for white non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match the existing surface laid over 20mm thick avg screed bed in CM 1:6 complete all as specified and directed. |
| 47 | S&F vitreous China Squatting pan 'Orrisa' pattern size 580x440mm white with integral foot rest, and jointing to PVC/CI bend and flush pipe complete including making good to floor complete all as specified & directed. |
| 48 | S&F PVC flushing cistern dual type 10 Litres capacity incl all accessosaries complete all as specified and directed. |
| 49 | S&F 15mm bore Bib Tap Chromium plated fancy type complete all as specified and directed. |
| 50 | S&F 15mm bore size pillar tap cast copper alloy chromium plated fancy type complete all as specified and directed. |
| 51 | S&F 15mm bore Stop Valve (Angle Valve) chromium plated fancy type complete all as specified and directed. |
| 52 | S&F vitereous china wash hand basin, white, flat back of size 550 x 400 mm including brackets, cutting for pinning in ends of brackets or erecting stand and including PVC waste pipe complete all as specified and directed. |
| 53 | S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 54 | S&F 600x450mm bevelled edge mirror or selected quality galass, mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washers complete all as specified and directed. |
| 55 | S&F Towel rail 600 mm long D type brass chromium plated with and including chromium plated brass screws and wooden/ plastic cleats etc complete all as specified and directed |
| 56 | Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 57 | S & F Soap dish, vitreous China white, approximate size 160x 160x90mm complete in all respect as specified. |
| 58 | M & L PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete in all respect as specified. |
| 59 | S&F PVC (SWR) pipes single socketed in in any length with rubber ting joints, laid in trencehs or in floors 75mm mm dia complete in all respect as specified. |
| 60 | S&F HDPE water storage tank of capacity 1000 Ltr, cylinderical vertical type, 3 layer, insulated with 75 mm thick PUF insulation of density 48 Kg/Cum covered with Lid having locking arangement including float valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball secured for iron pipe and fixed of 15 mm bore complete all as specified and directed. |
| 61 | S&F Second class softwood plain , solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered , put together with glue pinned at joints supplied and fixed complete all as specified and directed. |
| 62 | S&F second class soft wood 35 mm thick plain framed panelled shutters (any numbers of panels) with panels of timber flat on both sides (feather edged) or of veneered particles board medium density wood particle board with commercial face veneers,supplied and fitted to chowkats complete all as specified and directed. |
| 63 | M&L for two coat of synthetic enamel paint (finishing coat) over one coat of pink primer to new wooden surfaces of any description over 10 cm width or girth incl prepration of surfaces complete all as specified and directed. |
| 64 | S&F Vitreous China wash down pedestal pattern EWC, white water closet pan with intergral trap including seat cover ,making necessary connections to drain and to flushing pipe antisyphonage pipe etc, jointing to PVC/CI and flush pipe including making good to floor complete all as specified and directed. |
| 65 | S&F 75mm size mild steel butt hinges, medium weight cold rolled (including fixing with nails/ screws or selded as requried) complete all as specified and directed. |
| 66 | S&F 100 mm size mild steel butt hinges, medium weight cold rolled (including fixing with nails/ screws or selded as requried) complete all as specified and directed. |
| 67 | S&F 100 mm aluminum anodised barrel towe rbolt of extruded section and fixed complete all as specified and directed. |
| 68 | S&F 150 mm size aluminum aluminium handles, cast type, anodised complete all as specified and directed. |
| 69 | S&F 100 mm size aluminum aluminium handles, cast type, anodised complete all as specified and directed. |
| 70 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws as specified.complete all as specified and directed. |
| 71 | S&F 16mm outer dia 3-layer PP-R polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16)UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including app PP-R plain & brass threaded polyproplene random fittings fixed complete to wall , ceiligs or in floors etc. |
| 72 | S&F 25mm outer dia 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc |
| 73 | S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracketframing (Beam, tee, angle, channelor flat sections) includingdistance pieces, cleats etc complete all as specified and directed. |
| 74 | S & F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars,stiffeners, gusset plates, etc. |
| 75 | S&F plates (plain or chequered) square cut or notched forming holes, without any attachment complete all as spd and as directed by Engr-in-charge. |
| 76 | M & L 110mm bore for PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 77 | S & F PVC (SWR) bends any radius 110mm bore complete all as specified |
| 78 | S & F PVC (SWR) bends any radius 75mm bore complete all as specified |
| 79 | S & F PVC (SWR) vent cowl 110mm bore complete all as specified |
| 80 | S & F PVC (SWR) vent cowl 75mm bore complete all as specified |
| 81 | S & F vitreous china urinals bowl ,flat back of size 465 x 355 x 265 mm with grating and union for discharge pipe, complete including providing and fixing plugs , bedding urinal against wall in cement mortar 1:2 , securing urinal to pluigs with and including 60 mm long brass screw , pointing around urinal back in cement incl provn of flush pipe, grating and union for discharge pipe, complete all as specified and directed. |
| 82 | Exavation over areas in hard dense soil, exceeding 1.5 m and not exceeding 3.00 m deep and getting out complete all as specified & directed . |
| 83 | M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation etc, complete all as specified & directed |
| 84 | M&L stone wailing of random rubble, uncorsed well bounded, bedded and solidly hearted built in 1:6 brought to course complete all as specified and directed. |
| 85 | All as above item 84 but laid in dry completed all as specified and directed. |
| 86 | M&L for reinforced precast cement concrete type B1 1:2:4 (Using 20 mm graded stone aggregate) as in cover slabs man hole etc ) and set in cement mortar 1:4 complete all as specified and directed. |
| 87 | M & L for form work to sides and soffits of suspended slabs such as roof slabs , landings and similar work not exc 200 mm thick (horizontal or sloopping) for flat fair finished surfaces complete all as specified and directed. |
| 88 | M & L form work to edges of concrete flats, RCC/PCC bands floors roofs and similar works exc 10 cm and not exc 20 cm wide surface finished rough to receive plaster complete all as specified and directed. |
| 89 | M & L PCC type B-0 1:2:4 (12.5 mm graded aggregete) as in floor, drain haunching , benching , coping and etc similar work completed all as specified and directed. |
| 90 | S&F PVC (SWR) 75mm pipe single socket in any length with bubber ring lount laid in trenchs or in floors complete all as specified. |
| 91 | Material and labour for point wiring with 1.5 sqmm single core PVC insulated , unsheathed FRLS multi stranded copper cable , 1100 volt grade with necessary termination board in and incl PVC heavy duty casing n caping ISI marked on wall/ceilings including 1.5 sqmm single core PVC insulated multistranded copper conductor cable green in colour as earth earth continuity conductor connected to common earth dolley as rquired at site along with all accessories for the following : - Note :- Colour coding for point wiring should be maintained at site. Incase of any deviation necessary recovery will be made as applicable. |
| 92 | One light point controlled by one way switch. |
| 93 | One 3 pin socket outlet, 5 Amp independent board . |
| 94 | One 3 pin socket outlet 5 Amps on same board with other switches . |
| 95 | M&L for point wiring for 3 pin switch socket outlet 15 Amp independant with 2.5 sqmm copper conductor cable (multi strand ) FRLS PVC insulated and unseathed in and incl PVC casing and caping of adequate size to be turminated in sunk cast iron /pressed steel terminal boxes for mounting switches, sockets, regulators etc with 3mm thick plastic laminated sheet cover of adequate size incl continuous FRLS 1.5 sqmm PVC insulated and unseathed FRLS multistrand copper conductor, earth wire to common earth and connected to earth dully complete all as speicified. |
| 96 | S & F Switch socket combination 15 amp ,230V, 50 Hz flush type complete all as specified. |
| 97 | S & F Switch socket combination 5A , 230V, 50 Hz complete all as specified. |
| 98 | S & F Socket outlet 3/5 pin, 5/6 amp, flush type , ISI Mark complete all as specified. |
| 99 | S&F switch piano flush type single pole one way 5 amp , 230V, 50 Hz complete all as specified. |
| 100 | S&F Batten holder PVC/ poly carbonate typen with cord grip cap complete all as specified |
| 101 | Supply and Fixing LED bulb of 15 watt complete all as specified and directed. |
| 102 | S & F Ceiling rose 3 terminals, ISI Mark, complete all as specified & directed |
| 103 | S&F Ultra slim polycarbonate LED 4 feet long 20/22 watts with THD less than 15% very high efficiency suited for T-8 tube luminare with system efficacy 110 lumen per watts , high quality poly carbonate end cap in white finish and snap fitted to the housing, inbuilt driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete all as specified and directed. . |
| 104 | S&F distribution board double door made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface incl making good of surface complete all as specified and directed |
| 105 | S&F MCB single pole, 6 to 32 Amp 240 volt C curve 10 KA breaking capaity complete all as specified and directed |
| 106 | S&F MCB SPN 40 Amps,10 KA, 240 volt C curve IP 20 complete all as specified and directed |
| 107 | S&F distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 2 way , earth bar IP 43 protection, single pole and neutral 250 volts, flush to wall / fixed on surface incl making good of surface complete all as specified and directed |
| 108 | M&L for sub main wiring with two run of single core PVC insulated copper cable FRLS multi-stranded conductor 1.5 Sqmm drawn through in and including Non metalic PVC heavy duty PVC casing caping of suitable size as required at site with all accessories with one run of 1.5 Sqmm PVC insulated unsheathed copper conductor FRLS as earth wire ( green in colour ) , connected to common earth complete all as specified and directed.Note :1. Two run of main copper conductor 1.5 sqmm size , one run of 1.5 sqmm earth wire and one run of PVC conduit/PVC casing n caping shall be measured as one unit length .2. Proper colour coding shall be maintained as per IS code. |
| 109 | S&F LED building security light fitting 35 watts made of pressure diecast aluminium housing with acrylic cover as diffuser with IP65 and IK -07 protection , THD<10%, lumen output >= 110 lumen per watts with integrated lectronic driver incl copper connecting wire three core of suitable size upto connctor of ceiling rose complete all as specified and directed. |
| 110 | M&L security light GI braket made out of GI pipe 32 mm size 1.2 Mtr length bend to size at 120 degree complete with connecting clamp (02 Nos) , nut , bolt washers, paiting with 02 coat of synthetic aluminium paint incl surface preparation and primer coat all as specified and directed |
| 111 | Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.50 metre below normal ground level connected with galvanised iron earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel complete with 15mm dia GI light grade protection pipe from top edge of earth plate upto distribution board ( Appx. 3 metre long), 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt etc, PCC 1:2:4 in pit with pre-cast RCC M-15 cover slab reinforced with XPM not less than 4 Kg per Sqm, test point, angle iron frame of angle iron 40 x 40 x 6mm etc, all as shown in electric plate No 3 of SSR Part-I, complete with necessary earth work in any type of soil, removal to a distance not exceed 50m, testing on completion, complete all as specified and directed. NOTE: The rates for earthing includes the cost of earth lead and protection pipe upto 7.50m length. |
| 112 | Supply and laying or fixing and testing Cross linked poly ethelene ( XLPE) LT cable XLPE insulated , PVC inner sheathed bedded galavanised steel strip or wire armoured heavy duty 1100 volt grade with stranded aluminium conductor having cross sectional area 16 sqmm 2 core and confirming to IS -7098( Part-I 1988 as per latest amendments) , laid in trenches/ducts/through pipes/in floor/under roads/under hard standing /along pipe complete all aas specified and directed. |
| 113 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cables including getting out in hard soil complete all as specified and directed. (cable shall be laid 60 cm below ground level ) |
| 114 | Sand cushioning for cables with hight of cushioning as 8 cm below the cable and 15 cm above the cable all as specified and directed .(Note: Only punned thickness 18cm shall be measured and paid) |
| 115 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point. |
| 116 | Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil. |
| 117 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type-1, flat, size 250mm x 150mm x 40mm complete all as specified and directed |
| 118 | M&L point wiring using approved colour coding as per IS (Red , Black and Green for single phase circuits),with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, two single core, PVC insulated and unsheathed FRLS-H cable 1100 Volts grade, ISI-694 marked with valid CML No.in and including concealed PVC rigid conduit medium grade not less than 20 mm wide ,ISI marked with accessories fixed wall/roof/floor etc, with mild steel/pressed steel sunken box duly painted with two coats of anti corrosive paint/aiuminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLS-H cable as earth continuity conductor for one light point/fan point /bell point controlled by one switch complete all as specified and directed. Notes : (a) Wiring shall be done by using proper colour coding.(b) Earth wire shall be of green colour. (c) On RCC roof/celing PVC casing 'N' cappingshall be provided on surface with proper fixing clamps all as directed by Engr-in-Charge. |
| 119 | Description all as per serial item No 118 here-in-before but one 5 pin socket outlet, 6 amps on same board with other switches complete all as specified and directed. |
| 120 | S&F angle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 121 | Supply and Fixing LED bulb of 15 watt complete all as specified and directed. |
| 122 | Supply & fixing surface /wall mounted light fitting pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 20 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make- Crompton Greaves |
| 123 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 124 | M&L distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed.Note:- Distribution board and MCB's should be same make. |
| 125 | Supply and fix 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 126 | Supply and fix of SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 127 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed. |
| 128 | M&L 1100 volts grade heavy duty cable PVC insulated aluminium conductor ,served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart incluiding 4 mm dia suspension GI wire with stranded conductor 10 Sqmm twin core cable flat or circular incluiding taking down old unserviceable cable and stacking at site, complete all as specified. |
| 129 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. Please Enable Macros to View BoQ information |