| 1 | The work of safe carriage of the following material from store center Nawada/Workshop to work site under the jurisdiction of EDD-Budaun, Bisauli & Ujhani Approx. distance upto 0-70 Km. Including safe loading and unloading. |
| 2 | 25 KVA T/F |
| 3 | 100 KVA T/F |
| 4 | 250 KVA T/F |
| 5 | LT AB Cable 3x120 sqmm |
| 6 | LT AB Cable 3x95 sqmm |
| 7 | LT PVC Cable (3.5x70x35 sqmm) |
| 8 | LT PVC Cable (3.5x150x70 sqmm) |
| 9 | PCC Pole Support 8.5 Mtr. Long |
| 10 | 11 KV MS T-Off Channel (125x65x1300 mm) |
| 11 | MS Channel (Dropper) (100x50x2028 mm) for fuse set |
| 12 | Top Channel (125x65x2240 mm) |
| 13 | 11 KV Disc Insulator Composite 45 KN (T&C Type) |
| 14 | 11 KV Disc Fitting |
| 15 | 11 KV Pin Insulator Composite |
| 16 | Stay Complete (16x1800 mm) |
| 17 | MS Earthing Rod (20x2500mm) for PCC Pole |
| 18 | Earthing Complete |
| 19 | ABC Cable (3x50+1x35+1x16) sqmm |
| 20 | 11 KV Fuse Set |
| 21 | The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom). |
| 22 | LT Clamps with N&B |
| 23 | I Hook |
| 24 | I Hook with Suspention Clamp |
| 25 | LT Fuse Set |
| 26 | Henley Type Tailless Unit for 250 KVA with T,H,I type copper connector, Copper busbaar, Connecting Plate, Aluminium Connector and Heneley Type Tail less Unit covered with Box. |
| 27 | Clamp for LT T-OFF with N&B |
| 28 | Holding Clamp |
| 29 | Danger Board with Clamp |
| 30 | Barbed Wire |
| 31 | Al. Lugs for 240 KV Sqmm Cable |
| 32 | Construction of 250 KVA T/F plinth 2x2x1.5 Mtr. For mounting T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 2 mtr long of size 100x50x6 mm compete in all respect as per RESSPO Norms. |
| 33 | Cage fencing of 250 KVA Plinth mounted transformer in Town areas to avoid electrical human/cattle accidents by fabrication of cage (1 Inch Sq wiremesh) made of 10 No gauge in suitable size angle iron frame of size 7.5’(L)x5’(W)x8’(H) by trengthening of wire mesh 20x3 mm M.S. flat haorizentally as well as vertically, Grouting the panel with 1:2:4 cement/coorse send/brick ballast. The Frame should be bolted on angles at the four corners so that frame may be un-bolted/bolted at the time of replacement of the transformer. Provision of 1 gate should be there for maintenance of the transformer. Painting (1 coat of red oxide + 2 coat of Bus green enamel paint). The wire mesh should be earthed with 50x6 mm MS earthing strip with existing earthing of Transformer Body. All men, material and T&P provided by the contractor to complete the fabrication, transportation and installation. |
| 34 | Dismantling of following Transformer as per norms complete in all respect |
| 35 | 16 KVA T/F |
| 36 | 63 KVA T/F |
| 37 | 100 KVA T/F |
| 38 | Construction/Erection of Double Pole (except pole) Suitable for 25 KVA T/F including fitting of all accessories (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per RESSPO Norms). |
| 39 | Grouting of PCC 8.5 Mtr. Long with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/CC & sand Required as per RESSPO Norms. (All Grouting material shall be provided by the contractor). |
| 40 | The work of driving the earthing electrode and making connections with GI wire. |
| 41 | Mounting of following T/F,s as per norms complete in all respect - |
| 42 | 25 KVA T/F |
| 43 | 100 KVA T/F |
| 44 | 250 KVA T/F |
| 45 | Laying, Stringing, Sagging & Jumpring of Following Conductor complete in all respect as per RESSPO Norms. |
| 46 | LT AB Cable 3x120 sqmm |
| 47 | LT AB Cable 3x95 sqmm |
| 48 | LT PVC Cable (3.5x70x35 sqmm) |
| 49 | LT PVC Cable (3.5x150x70 sqmm) |
| 50 | ABC Cable (3x50+1x35+1x16) sqmm |
| 51 | Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms. (All the grouting material shall be provided by the contract for execution of work). |
| 52 | Fixing of danger board on each location and G.I. barbed wire including proper clamping as per RESSPO Norms. (Danger Board shall be provided by the contractor as per RESSPO Norms). |
| 53 | Erection/Fixing of Heneley Type Tail less Unit with T,H,I type copper connector, Copper busbaar, Connecting Plate, Aluminium Connector and Heneley Type Tail less Unit covered with Box. complete in all respect. (All material shall be provided by the contractor) |
| 54 | Erection/Fixing of 11 KV Fuse Set with fixing of all accessories & connections. complete in all respect as per RESSPO Norms. |
| 55 | Erection/Fixing of LT Fuse Set with fixing of all accessories & connections. complete in all respect as per RESSPO Norms. (All material shall be provided by the contractor). |
| 56 | Safe back carriage of Following item (if any) from work site to Store Center, Nawada, Budaun approx distance upto 0-70 Km including loading & unloading. |
| 57 | 16 KVA T/F |
| 58 | 63 KVA T/F |
| 59 | 100 KVA T/F Please Enable Macros to View BoQ information |