| 1 | Annual regular maintenance, rewinding & repairing of single & three phase submersible motor pump sets & buster pump control panels, starters, installed in under nagar palik nigam Ujjain i/c of all of work realedted of repairing & rewinding to motor pumps, control panels, starters, replacement of all required spare part etc. opening & refitting taking out and lowering the submeribles from the tubewells, loading, unloading transfportation, trypot with chain pully, vechicle & labor trail & testing etc complete work. |
| 2 | Lowering & taking out of single/three phase submersible motor pump set |
| 3 | Labour only for taking out of single phase submersible pumping set of capacity 1 to 3 HP from the tube well with flexible/ rigid pipe line assembly, electrical cable, nylone rope, testing etc. complete including disconnecting the electrical cable from pump & starter -Depth up to 150 mtr.26.20/P-330 |
| 4 | Labour only for lowering of single phase submersible pumping set of capacity 1 to 3 HP in the tube well with flexible/ rigid pipe line assembly, electrical cable, nylone rope, testing etc. complete including connecting the electrical cable from pump & starter - Depth up to 150 mtr.26.21/P-330 |
| 5 | Labour only for taking out of three phase submersible pumping set from the tube well with pipe line assembly, electrical cable, testing etc. Complete including disconnecting the electrical cable from pump & starter. 26.22/P-331 |
| 6 | 3 hp to 7.5 hp - depth up to 150 mtr. |
| 7 | Above 7.5 hp to 12.5 hp - depth up to 150 mtr. |
| 8 | Labour only for lowering of three phase submersible pumping set in the tube well with pipe line assembly, electrical cable, testing etc. Complete including connecting the electrical cable from pump & starter. 26.23/P-331 |
| 9 | 3 hp to 7.5 hp - depth up to 150 mtr. |
| 10 | Above 7.5 hp to 12.5 hp - depth up to 150 mtr. |
| 11 | Repairing of single/three phase submersible motor pump set |
| 12 | Removing the old burn winding from stator & cleaning of slot then complete rewinding of submersible motor by using PVC insulated ISI marked quality copper conductor with suitable gauge including insulating material like bamboo, strip, fire proof papers, leeve, cotton tape, PVC tape including cable jointing of motor. 26.25/P-331 |
| 13 | A. Single phase 100 mm dia |
| 14 | B. Three phase 100 mm & 150 mm dia |
| 15 | 5 HP (100 mm dia.) |
| 16 | Above 6.0 tp 7.5 HP (150 mm dia.) |
| 17 | Above 10.0 to 12.5 HP (150 mm dia.) |
| 18 | Providing & fixing of Adjusting Cap 1 HP to 5 HP /100mm26.25.5.1/332 |
| 19 | Providing & fixing of L N key BMM 1 HP to 5 HP /100mm26.25.6.1/332 |
| 20 | Providing & fixing of L N key BMM 3 HP to 15 HP /150mm26.25.6.2/332 |
| 21 | Providing & fixing of Pump sleeve SS 1 HP to 5 HP /100mm26.25.13.2/333 |
| 22 | Providing & fixing of impeller 1 HP to 5 HP /100mm26.25.15.1/333 |
| 23 | Providing & fixing of impeller 3 HP to 15 HP /150mm26.25.15.2/333 |
| 24 | Providing & fixing of stud for suction 1 HP to 5 HP /100mm26.25.23.1/333 |
| 25 | Providing & fixing of stud for suction 3 HP to 15 HP /150mm26.25.23.2/333 |
| 26 | Providing & fixing of pump shaft key 1 HP to 5 HP /100mm26.25.27.1/333 |
| 27 | Providing & fixing of pump shaft key 3 HP to 15 HP /150mm26.25.27.2/333 |
| 28 | Providing & fixing of pump coupling & motor coupling 1 HP to 5 HP /100mm26.25.29.1/334 |
| 29 | Providing & fixing of pump coupling & motor coupling 3 HP to 15 HP /150mm26.25.29.2/334 |
| 30 | Providing & fixing of thrust bearing plate complete 1 HP to 5 HP /100mm26.25.40.1/334 |
| 31 | Providing & fixing of thrust bearing plate complete 3 HP to 15 HP /150mm26.25.40.2/334 |
| 32 | Providing & fixing of thrust bearing (carben) 1 HP to 5 HP /100mm26.25.41.1/334 |
| 33 | Providing & fixing of thrust bearing (carben) 3 HP to 15 HP /150mm26.25.41.2/334 |
| 34 | Providing & fixing of thrust bearing hosing ci 1 HP to 5 HP /100mm26.25.43.1/334 |
| 35 | Providing & fixing of thrust bearing housing ci 3 HP to 15 HP /150mm26.25.43.2/334 |
| 36 | Providing & fixing of New rotor26.25.58/336 |
| 37 | 2 HP (100 mm. dia)26.25.58.2/336 |
| 38 | 3 HP (100 mm. dia)26.25.58.3/336 |
| 39 | Above 6.0 to 7.5 HP (150 mm. dia)26.25.58.10/336 |
| 40 | Labour only for stator servicing 1 HP to 5 HP /100mm26.25.62.1/336 |
| 41 | Labour only for stator servicing 5 HP to 10 HP /150mm26.25.62.3/336 |
| 42 | Labour only for rotor balancing 1 HP to 5 HP /100mm26.25.63.1/336 |
| 43 | Labour only for rotor balancing 3 HP to 15 HP /150mm26.25.63.2/336 |
| 44 | Provision for Repairing of submersible pump of any diameter i/c cost of material, labour, transportation etc. in case of breakdown maintenance as per approved specification and as directed by Engineer in charge. 14.28/241 |
| 45 | REPAIRING OF CONTROL PANEL |
| 46 | Providing & Fixing of Relay unit L&T Type26.25.71/337 |
| 47 | Providing & Fixing of Contacter L&T Type - 16 Amp26.25.73/337 |
| 48 | Providing & Fixing of Kit Point Set L&T Type26.25.76/337 |
| 49 | Providing & Fixing of No Volt Coil L&T Type26.25.79/337 |
| 50 | Providing & Fixing of Amp meter (Round) 26.25.85/337 |
| 51 | Providing & Fixing of Volt Meter (Round)26.25.86/337 |
| 52 | Providing & Fixing of Amp meter (Square)26.25.87/337 |
| 53 | Providing & Fixing of Volt Meter (Square) 26.25.88/337 |
| 54 | Providing & Fixing of ON Switch26.25.89/337 |
| 55 | Providing & Fixing of Off Switch26.25.90/337 |
| 56 | Providing & Fixing of terminal plate26.25.91/337 |
| 57 | Providing & Fixing of indicator lamp26.25.92/337 |
| 58 | Providing & Fixing of MCB -Single Pole - 16 -25 Amp26.25.93/337 |
| 59 | Providing & Fixing of MCB -Three Pole - 32 Amp26.25.94/337 |
| 60 | Providing & Fixing of MCB -Three Pole - 40 Amp26.25.95/337 |
| 61 | Providing & Fixing of MCB -Three Pole - 63 Amp26.25.96/337 |
| 62 | Providing & Fixing of Capacitor 36 MFD26.25.97/337 |
| 63 | Providing & Fixing of Capacitor 50 MFD26.25.98/337 |
| 64 | Providing & Fixing of Capacitor 120-150 MFD26.25.99/337 |
| 65 | Providing & Fixing of Capacitor 200-250 MFD26.25.100/337 |
| 66 | Provision for Repairing of Starter/control panel i/c cost of material, labour, transportation etc. complete as per approved specification and as directed by Engineer in charge14.29/241 |
| 67 | Supply & erection of readymade mini pump house (control panel box) GI sheet of 18 gauge of size 90 cm x 90 cm x 60cm with 40 x 40 x 5 mm angle Iron frame to fix it 200mm below ground level with hold fasts grouted in foundation and 300mm above ground level for clearance suitable for fixing of control panel, fuse unit, main switch etc. as per approved specification.14.21/239 |
| 68 | REPLACEMENT OF FLAT COPPER CABLE & OTHER REQ. MATERIAL |
| 69 | Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. 11.5/165 |
| 70 | 2.5 Sq.mm.multi strand |
| 71 | 4.0 Sq.mm.multi strand |
| 72 | 6.0 Sq.mm.multi strand |
| 73 | Supplying and laying of approved Make Nylon rope 12mm thick complete with binding for support of pump and motor11.6/165 |
| 74 | Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS-1239/2011 Part II3.1/P-47 |
| 75 | 32 mm dia (medium) |
| 76 | 50 mm dia (medium) |
| 77 | Labour only for fixing G. I. cross outer threading in G.I. Pipe line i/c cutting, threading, testing and carriage etc. complete (Old work)3.48/P-61 |
| 78 | 32 mm dia |
| 79 | 50 mm dia |
| 80 | Providing and fixing of well cap on top of the tube well for protection M.S. Caps 21.9/P-316 |
| 81 | 150mm dia |
| 82 | 200mm dia |
| 83 | Providing, laying, Jointing & field testing of High Density Polyethylene pipes, (HDPE) confirming to IS 4984/14151/12786/13488 with necessary jointing material like mechanical connector or jointing pipes by heating to the ends of pipes with the help of Teflon coated electric mirror/ heater to the required temperature and then pressing the ends together against each other, to form a monolithic & leak proof joint by thermosetting process. It may be required to be done with Jacks/HydraulicJacks/But fusion machine. (50mm & above fusion jointed & below 50mm mechanical jointed)UADD SOR VOL. - I 2nd Aug. 20217.1/103 |
| 84 | 25 mm dia |
| 85 | 32 mm dia |
| 86 | Providing and fixing gun metal/ brass check (non-return) valves Class-II, female ends, tested to 21.09 kg/sq.cm. Screwed 6.8/P-90 |
| 87 | 25 mm dia |
| 88 | 32 mm dia |
| 89 | Providing and fixing G. I. Bend 90 degree in G.I. Pipe line i/c cutting threading testing etc. complete (Old work) 32mm dia6.27/P-95 |
| 90 | 25 mm dia |
| 91 | 32 mm dia |
| 92 | Supply of XLPE Insulated power cable (conforming IS-7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade, 2core/3½core/4core ISI MARKED with Alu. Stranded /solid conductorUADD SOR VOL. - IV 2nd Aug. 202114.1/P-78 |
| 93 | ARMOURED 2 Core |
| 94 | 4 Sq.mm.(Heavy Duty) |
| 95 | 6 Sq.mm.(XLPE) |
| 96 | ARMOURED 4 Core |
| 97 | 6 Sq.mm.(XLPE) |
| 98 | 10 Sq.mm.(XLPE) Please Enable Macros to View BoQ information |