| 1 | DSR Item No. 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 2 | Group B |
| 3 | DSR Item No. 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | DSR Item No. 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 5 | Group B |
| 6 | DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 7 | 3 x 1.5 sq. mm |
| 8 | 3 x 2.5 sq. mm |
| 9 | 4 x 1.5 sq. mm |
| 10 | 3 x 4 sq. mm |
| 11 | DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 12 | 25 mm |
| 13 | DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 14 | 5/6 amps switch |
| 15 | 2 way 5/6 A. switch |
| 16 | 3 Pin 5/6 A. socket outlet |
| 17 | 15/16 amps switch |
| 18 | 6 Pin 15/16 A. socket outlet |
| 19 | Telephone socket outlet |
| 20 | TV antenna socket outlet |
| 21 | Bell push |
| 22 | DSR item No.1.26 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 23 | DSR item No.1.28 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 24 | 1 or 2 Module |
| 25 | 3 Module |
| 26 | 4 Module |
| 27 | 6 Module |
| 28 | 8 Module |
| 29 | 12 Module |
| 30 | DSR item No.1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 31 | DSR item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 32 | DSR Item No. 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 33 | DSR Item No.1.38 Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 34 | DSR item No.1.57 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 35 | DSR Item No. 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator). |
| 36 | 4 way (4 + 12) Double door |
| 37 | DSR Item No.2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required). |
| 38 | 4 way (4 + 12), Double door |
| 39 | DSR Item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 40 | Single pole |
| 41 | Triple pole and neutral |
| 42 | Triple pole |
| 43 | DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required |
| 44 | 100 A,30KA,FPMCCB |
| 45 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption,(As per Complete Item No. 18 of the DNIT) |
| 46 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 380-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 47 | DSR item No.9.2.4 Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope,(As per Complete Item No. 19 of the DNIT) |
| 48 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum |
| 49 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 50 | Supply & erection of fresh air fan high speed motor with copper wound 10” sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of Havells make Ventiliar DX White / Orient make Ventilator / Crompton make Brisk Air/ Bajaj make 70049 250mm sweep only. (As per Complete Item No. 20 of the DNIT) |
| 51 | DSR item no.8.9.5 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, (As per Complete Item No. 21 of the DNIT) |
| 52 | 18- 22 watt |
| 53 | S/E of ding dong type electronic bell including carriage, testing with suitable size of nuts / bolts and other petty material etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. The bell should be of Cona/ Anchor/ Gold Medal/ Havells make only. |
| 54 | Supply and Erection of Gate Light fitting with clear / frosted glass duly wired with B-22 d / E-27 lamp holder complete with CFL lamp of 9/11 watt. The lamp should be Philips make and the fitting should be of reputed make & pillar mounting type. (As per Complete Item No. 23 of the DNIT) |
| 55 | S/E of LED Bulk Head Luminaries weather proof frosted light with PMMA / PC reflector and silicon gasket to be installed on surface. The LED fitting should have minimum system Lumen output minimum 1000 Lumen and the driver of the fitting should be workable on 140-260 Volt. (As per Complete Item No. 24 of the DNIT) Please Enable Macros to View BoQ information |