| 1 | Stage I |
| 2 | Design, Supply, installation, testing & commissioning of Vertical Turbine pump motor set of specified duty parameters with specified capacity vertical solid shaft TEFC squirrel cage induction motor of following Specifications:i) Type : Vertical Turbine, Mixed Flow Pump ii)Discharge of pump: : 30 cusec (3058 m3/hr) iii)Dynamic Head: : 9.00 m iv) Speed: : 960 RPM v) Efficiency: : 82.5% vi) Fluid to be handled: : Raw Water River vii) No. of stages: Singleviii) Duty: Continuous x) Column pipe size Not less than 500mm ND xi)Sump Bed Level : 91.00 m xii) Minimum Water Level : 93.00 m xiii) Machine Floor Level : 100.285 m xiv) Location of Discharge Elbow : Below Machine Floor LevelMaterial of construction Casing: : Cast Iron FG260 Impeller: : Stainless steel/bronze : Bowl & Suction Bell: Cast Iron FG260Shaft/Shaft coupling: AISI 410 Stainless Steel Shaft Sleeve: AISI 410 Stainless SteelColumn Pipe: MS ERW Base Plate: MS Suction Strainer: SS Motor specifications: i)Rating of motor: Suitable for above pump parameters.ii)Frequency: 50 Hz +_3% iii)Phase 03 iv)Voltage: 415±10% v)Efficiency: IE2 vi) RPM: 960vii) Insulation Class: F or abovevii) Enclosure: TEFC The Job includes fabrication and fitting of foundation out of requisite ISMB beams, channels and chequered plate as per site requiremnets for fixing of sole plate etc and commissioning at site and the testing on full load.Note :if not visibile properly please go to tender document |
| 3 | Fabrication,Providing and fitting of MS Pipe for rising main of Size 800mm (probable Dia) of thickeness 7 mm to be connected with the delivery side of pump (45Mtr), The Job includes fab of Y Junction, Increaser with requisite flange to connect the pump outlets with the 800 mm dia Rising main and the pipes are connecting by end to end welding up to delivery chamber. . The job also includes fabrication of bends and offsets as per the site requirement/land profile and painting of Y Junction and rising main in two coats of metal primer and synthetic paint. |
| 4 | Design Supply installation testing and commissio 05 Ton EOHT Crane to be installed inside the pump house. The job further includes providing/Fitting of other allied support Includes ISMB400 for Bridge Girder,ISMB250 for supporting rails, channels,32mm Sq.bar for traveling of end carriages,End carriages and gear and puppy system for providing different directions of the gantry. The job further includes providing of U clamps , Bulldogs grips etc as per requirements. the job further includesProviding and installation of 5-ton x 6 m lift heavy duty chain pully block along with monorail. Total Steel weight(1.686MT) includes ISMBeams, Channels, sq bars etc. |
| 5 | Voltage stabilizers: Supply, installation , testing and commissioning of 400 KVA copper wound, oil cooled , Manually operated Voltage stabilizer ( complete Oil Filled) suitable for output voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bi-directional wheels for easy handling, necessary monitors and user's controls on front and user's controls on front panel such as indication, alarm, voltmeter and selector switch for measuring input and output voltage, Manual selector switch, etc. Suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided. All three phases shall be independently monitored and corrected. Following protections and indications shall be incorporated over voltage / under voltage, Single Phasing Cut off contactor with electronic output sensing unit. |
| 6 | Main distribution panel by way of the following:Incomer panel:Supply, Installation testing and commissioining of cubicle type LT Control panel fabricated out of MS Sheet of guage 16 SWG with I/C feeders of 400A, 4-Pole ACB (Manual Draw-out Type) with Microprocessor release (O/C, S/C & E/F) having breaking capacity Icu of 50 kA at 415V with 6NO+6NC potential free auxiliary contacts, secondary isolating contacts with all necessary Electro-Mechanical protections & interlocks etc.( 01 No)MCCB Out Going Panel:Supply, retrofitting in panel O/G feeders, testing and commissioning of 300A, 3-Pole MCCB having breaking capacity Icu of 50 kA at 415V with 6NO+6NC potential free auxiliary contacts, secondary isolating contacts with all necessary Electro Mechanical protections & interlocks etc.( 02 Jobs)_Auxiliary panelSupply, retrofitting in panel auxiliary feeder and testing and commissioning of 100A, TPN MCCB with Microprocessor release having breaking capacity Icu of 35 kA at 415V along with complete control wiring.(01 No)Complete fitting of panel metering and protection components as under: LED Ammeter 3Ph with inbuilt selector switch - 96x96mm; flush mounting type; Class 1LED Voltmeter 3Ph with inbuilt selector switch - 96x96mm; flush mounting type; Class 1 LED frequency meter Class 0.2Digital PF meter Class 1 96x96mm Current transformerPotentional transformer Phase indicating LED indicatorsFault annunciation and alarm system comprising of alarm fascia panel with required number of fascia windows, one for each fault and flash type, complete with three push buttons for alaram acceptance resetting and testing. The annunciation scheme shall also provide annunciation of alarm for D.C failure, D.C earth fault and D.C under voltage.Starter:Supply, installation, testing & commissioning of 415 V Fully automatic Microprocessor based 200-300 H.P soft starter with built in bypass arrangement for pump control application as per general specification as under:Control Method -Torque Control, Input voltage- 415 V, 3 Phase, Input frequency - 50/ 60 Hz (± 5%), Confirmative to standard - IEC 61947-4- 2UL, CSA, CE, Motor protection - inbuilt Thermal Protection, Starter protection - SC UV, Phase unbalance, Phase failure, EMC Std- IEC 61000-4-2 Level- 3 & IEC 61000-4-3-Level-3, Built in communication as per RS 485. ( 02 Jobs)Capacitor Bank:Providing and installation of shunt capacitor panel in parallel with motors consisting of following:• Capacitors of total rating 125kVAR Capacitor duty contractors MCCB 3P 250A• LED indicators R Y B Suitable size unarmoured aluminium cable for connection. |
| 7 | Cable:Supplying and laying of 3.5Cx300 sq.mm XLPE insulated, steel sheathed,armoured L T cable with 1100V grade with ISI mark, solid/ stranded aluminium conductor of suitable lengths to be laid from HT transformer upto Voltage Stabliser/Panel . The job shall include providing and crimping of 300 sq.mm Aluminium lugs at all cable terminations/ connections. |
| 8 | Insulating Mats:Providing and laying at site of high Voltage antiskid insulating rubber mat 3 mm thick for floor covering around Electro-mechanical gadgets for safe guarding life and limb of workmen due to possible leakage of current and short circuiting. The mats shall have the following characteristics/technical specifications:• Confirming to IS -15652-2006 with latest amendments• Thickness- 3.0 mm• Width – 1 Mtr• Length 15 Mtr• Type Anti- skid• Material- PVC Elastomer• Application: suitable for both AC and DC Electric installations.• Class – C Colour- Blue |
| 9 | Tools and other items: -The Tool Kit for maintenance shall comprise of the following and all the items as mentioned below shall be of Taparia/ equivalent reputed make:Double ended Spanner of Size (6/7 to 30/32) (01 complete set)Ring Spanner Set of Size (6/7 to 30/32) (01 complete set)Cutting Pliers, 8 inch: (01 No.)Nose Pliers 8 inch: (01 No.)Insulated Screw Driver 12 inch/ 8 Inch/ 6 Inch/ 4 inch :( 01 No. Each)Hammer, 01 Kg and 450g: (01 No each)Heavy duty Pipe Wrench 12 inch & 8 inch: (01 No. each)Bearing puller (sizes 6 & 8): (01 no. each)Spirit level (600mm): 01 No.Ladder 20ft long( 1 No.)Fire extinguishers (ABC type) 06 kg capacity as per IS 15683: 2 nos. |
| 10 | Earthing:Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and 20mm GI (medium class) watering pipe 2.7 meter long, funnel etc. with charcoal/ coke and salt as required. |
| 11 | Transformer:Supply/Installation/ Erecting/Testing and Commissioningof 400 KVA outdoor type copper wound distribution transformer 11000/ 440 Volt with On Load Tap Changer - 15% to +5% in steps of 1.25%, Level-II (as per amendment no.4 to IS 1180 (Part I : 2014) continuously rated for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45º C by thermometer in oil and 50ºC by the resistance in winding after continuous run resistance in winding at full load rating, the transformer full load rating, the transformer should have oil immersed winding having vector group DY 11, HT side connected in Delta and LT side connected in Star with neutral brought out connected to provided separate earthing. The transformer shall have power terminal arrangement, bushings / cable end box on HT side and cable end box on LT side. The transformer should have following standard fittings.1) Oil conservator with filling hole with cap and plain oil level gauge.2) Silica gel dehydrating breather charged with Silica Gel.3) Oil drain valve.4) Oil filter valve.5) Lifting eyes / hooks.6) Two earthing terminals.7) Diagram and rating plate.8) Air Vent.9) Explosion Vent.10) 100 mm dia thermometer with thermometer pocket11) Four bi directional plain roller.12) Bucholtz relay.13) Resistance Temp. detector.14) Marshalling box.15) Automatic Voltage Regulator (AVR). 16) Remote Tap Changing Controller (RTCC). The Job Includes Creation of Sub Station at the site by way of providing Tubular Poles (3 No.) SP33 with embendment in cement concrete along with all the required crosses at the site. The Job further includes Providing/fitting of 0.05 ACSR AL conductor( approx 220 m) and allied fitting for creation of Sub station. The Job further includes providing of GO Set , DO SET , 11 KV Lightening Arrester Set, V cross, F.Top , Polemer HT Insulators with pins, ISMC 100 -8ft long channels (7No) and including allied fittings , clamps ,nuts and bolts. The Job further includes Fabrication, erecting of Steel Transformer Bed of size 6x8 feet fabricated out of ISMB200/150 ,ISMC 100, 8mm thick chequired plate,fixing of transformer bed legs in cement concrete and other angles if required Approx. weight (900 Kgs). . The job further includes painting of poles ,channels, crosses etc in metal primer (01 coat) and two coats of silver paint and job includes installation of earthing station by way of electrodes , GI strips, Baby clamps etc . |
| 12 | Supply installation testing and commissioning of PVC 95 Sqmm Cu conductor to fitted inside the pump house connecting the internal Gadgets VIZ Panel, Motor,Starters etc. The Job includes providing of Requisite copp[er Lugs and To be fitted in a manner way Like providing of Cable try etc. |
| 13 | Providing and fitting of Ductile Iron 800 mm Dia ,both side flanged Non Return Valve/Reflex Valve to be installed on the deleivery lines at the formation of V junction. The Job includes of P/F of requisite flanges on both sides ,gaskets ,nuts and bolts in order to allign with the rising main The Specification should satisfy IS:14846 standards with a PN 1.0 |
| 14 | Illumination of pump house by way of P/F of 50W LED Flood lights in 1.5 sqmm PVC copper wire fitted in PVC conduits -(06 Nos) , including P/F of heating points ( 03 Nos) in 2.5 sqmm PVC copper wire in PVC conduit , P/F lighting point inside pump house in PVC conduit of 7W LED Lamps ( 04Nos). The job includes all accessories viz Switch board,Switches,MCBs, Main panel board required as per site requirement. |
| 15 | Stage II |
| 16 | Design, Supply, installation, testing & commissioning of Horizental type motor set of specified duty parameters with specified capacity vertical solid shaft TEFC squirrel cage induction motor of following Specifications:i) Type Horizental Type, Mixed Flow Pump, Split Casingii)Discharge of pump: 20 cusec iii)Dynamic Head: 8.00 miv)Speed: 960 RPMv) Efficiency: 85%vi) Fluid to be handled: Raw Water Rivervii) No. of stages: Singleviii) Duty: Continuousix) NPSHA: 3.5 MMaterial of constructionCasing: Cast Iron FG260Impeller: Stainless steel/bronzeShaft/Shaft coupling: AISI 410 Stainless SteelShaft Sleeve: AISI 410 Stainless SteelBase Plate: MSSuction Strainer: SSMotor specifications:i)Rating of motor: Suitable for above Pump Parametersii)Frequency: 50 Hz +_3%iii)Phase 03iv)Voltage: 415±10%v)Efficiency: IE2vi) RPM: 960vii) Insulation Class: F or abovevii) Enclosure: TEFC The job includes providing fitting and installation of 5Hp 3ph priming monoblock pump motor along with GI suction and delivery pipes including footvalve, elbows, gate valves, starter,wire etc.The job further includes Fab.P/F of 600 mm Dia MS Foot valve having 2/3 openings with strainer for 20 Cusec Pump on suction side. |
| 17 | Providing and fitting of MS Pipe of Size 600 mm (probable Dia) of thickness 6.0 mm for the Suction and delivery side of the equiipment. The job further includes providing and fabrication of Flanged Bends/ Off sets Etc. Approximately the total length of pipe to be utilsed is 20Mtr. |
| 18 | Voltage stabilizers: Supply, installation , testing and commissioning of 250 KVA copper wound, oil cooled , Manually operated Voltage stabilizer ( complete Oil Filled) suitable for output voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, as mentioned below. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bi-directional wheels for easy handling, necessary monitors and user's controls on front and user's controls on front panel such as indication, alarm, voltmeter and selector switch for measuring input and output voltage, Manual selector switch, etc. Suitable capacity termination strips and bus bars for incoming and outgoing cable should be provided. All three phases shall be independently monitored and corrected. Following protections and indications shall be incorporated over voltage / under voltage, Single Phasing Cut off contactor with electronic output sensing unit. |
| 19 | Main distribution panel by way of the following:Incomer panel:Supply, Installation testing and commissioining of cubicle type LT Control panel fabricated out of MS Sheet of guage 16 SWG with I/C feeders of 300A, 4-Pole MCCB having breaking capacity Icu of 50 kA at 415V with 6NO+6NC potential free auxiliary contacts, secondary isolating contacts with all necessary Electro-Mechanical protections & interlocks etc.( 01 No)MCCB Out Going Panel:Supply, retrofitting in panel O/G feeders, testing and commissioning of 250A, 3-Pole MCCB having breaking capacity Icu of 50 kA at 415V with 6NO+6NC potential free auxiliary contacts, secondary isolating contacts with all necessary Electro Mechanical protections & interlocks etc.( 02 Jobs)_Auxiliary panelSupply, retrofitting in panel auxiliary feeder and testing and commissioning of 100A, TPN MCCB with Microprocessor release having breaking capacity Icu of 35 kA at 415V along with complete control wiring.(01 No)Complete fitting of panel metering and protection components as under:LED Ammeter 3Ph with inbuilt selector switch - 96x96mm; flush mounting type; Class 1LED Voltmeter 3Ph with inbuilt selector switch - 96x96mm; flush mounting type; Class 1LED frequency meter Class 0.2Digital PF meter Class 1 96x96mmCurrent transformerPotentional transformerPhase indicating LED indicatorsFault annunciation and alarm system comprising of alarm fascia panel with required number of fascia windows, one for each fault and flash type, complete with three push buttons for alaram acceptance resetting and testing. The annunciation scheme shall also provide annunciation of alarm for D.C failure, D.C earth fault and D.C under voltage.Starter:Supply, installation, testing & commissioning of 415 V Fully automatic Microprocessor based 150 H.P soft starter with built in bypass arrangement for pump control application as per general specification as under:Control Method -Torque Control, Input voltage- 415 V, 3 Phase, Input frequency - 50/ 60 Hz (± 5%), Confirmative to standard - IEC 61947-4- 2UL, CSA, CE, Motor protection - inbuilt Thermal Protection, Starter protection - SC UV, Phase unbalance, Phase failure, EMC Std- IEC 61000-4-2 Level- 3 & IEC 61000-4-3-Level-3, Built in communication as per RS 485. ( 02 Jobs)Capacitor Bank:Providing and installation of shunt capacitor panel in parallel with motors consisting of following:• Capacitors of total rating 125kVAR • Capacitor duty contractors• MCCB 3P 250A • LED indicators R Y B Suitable size unarmoured aluminium cable for connection. |
| 20 | CableSupplying and laying of 3.5Cx240 sq.mm XLPE insulated, steel sheathed,armoured L T cable with 1100V grade with ISI mark, solid/ stranded aluminium conductor of suitable lengths to be laid from HT transformer upto Voltage Stabliser/Panel . The job shall include providing and crimping of 240 sq.mm Aluminium lugs at all cable terminations/ connections. |
| 21 | Insulating Mats:Providing and laying at site of high Voltage antiskid insulating rubber mat 3 mm thick for floor covering around Electro-mechanical gadgets for safe guarding life and limb of workmen due to possible leakage of current and short circuiting. The mats shall have the following characteristics/technical specifications:• Confirming to IS -15652-2006 with latest amendments• Thickness- 3.0 mm• Width – 1 Mtr• Length 10 Mtr• Type Anti- skid• Material- PVC Elastomer• Application: suitable for both AC and DC Electric installations.• Class – C Colour- Blue |
| 22 | Earthing:Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and 20mm GI (medium class) watering pipe 2.7 meter long, funnel etc. with charcoal/ coke and salt as required. |
| 23 | Transformer:Supply/Installation/ Erecting/Testing and Commissioningof 250 KVA outdoor type copper wound distribution transformer 11000/ 440 Volt with On Load Tap Changer - 15% to +5% in steps of 1.25%, Level-II (as per amendment no.4 to IS 1180 (Part I : 2014) continuously rated for 3 Ph, 50 Hz, at full load and temp. rise not exceeding 45º C by thermometer in oil and 50ºC by the resistance in winding after continuous run resistance in winding at full load rating, the transformer full load rating, the transformer should have oil immersed winding having vector group DY 11, HT side connected in Delta and LT side connected in Star with neutral brought out connected to provided separate earthing. The transformer shall have power terminal arrangement, bushings / cable end box on HT side and cable end box on LT side. The transformer should have following standard fittings.1) Oil conservator with filling hole with cap and plain oil level gauge.2) Silica gel dehydrating breather charged with Silica Gel.3) Oil drain valve.4) Oil filter valve.5) Lifting eyes / hooks.6) Two earthing terminals.7) Diagram and rating plate.8) Air Vent.9) Explosion Vent.10) 100 mm dia thermometer with thermometer pocket11) Four bi directional plain roller.12) Bucholtz relay.13) Resistance Temp. detector.14) Marshalling box.15) Automatic Voltage Regulator (AVR). 16) Remote Tap Changing Controller (RTCC). The Job Includes Creation of Sub Station at the site by way of providing Tubular Poles (3 No.) SP33 with embendment in cement concrete along with all the required crosses at the site. The Job further includes Providing/fitting of 0.05 ACSR AL conductor( approx 600 m including replacement of GI HT conductor of existing scheme) and allied fitting for creation of Sub station. The Job further includes providing of GO Set , DO SET , 11 KV Lightening Arrester Set, V cross, F.Top , Polemer HT Insulators with pins, ISMC 100 -8ft long channels (7No) and including allied fittings , clamps ,nuts and bolts. The Job further includes Fabrication, erecting of Steel Transformer Bed of size 6x8 feet fabricated out of ISMB200/150 ,ISMC 100, 8mm thick chequired plate,fixing of transformer bed legs in cement concrete and other angles if required Approx. weight (900 Kgs). . The job further includes painting of poles ,channels, crosses etc in metal primer (01 coat) and two coats of silver paint and job includes installation of earthing station by way of electrodes , GI strips, Baby clamps etc . |
| 24 | Supply installation testing and commissioning of 95 Sqmm Cu conductor to fitted inside the pump house connecting the internal Gadgets VIZ Panel, Motor etc. The Job includes providing of Lugs and To be fitted in manner way Like providing of Cable try etc. |
| 25 | Illumination of pump house by way of p/f of 50W LED Flood lights in 1,5 sqmm copper wire fitted in PVC conduits -(03 Nos) , including p/f of heating points ( 02 Nos) in 2.5 sqmm copper wire , lighting point inside pump house of 5W LED ( 04Nos). The job includes all accessories viz Switch board, Main panel board, required as per site requirement. |
| 26 | Civil Part |
| 27 | Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil |
| 28 | Silt clearance from canals inclusive of initial lead of 50 meters and all lifts by Mechanical Means (Wet) |
| 29 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 30 | Extra for every additional lift of 1.5 m or part thereof in excavation/banking excavated or stacked material : All kinds of soil (Lift one) |
| 31 | Providing and laying of dry stone soling including cost of stones |
| 32 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 33 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 34 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All worksupto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 35 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 36 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 37 | Centering and shuttering including strutting, propping etc. and removal of form |
| 38 | Suspended floors, roofs, landings, balconies and access platforms. |
| 39 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 40 | Columns, pillars, piers, abutments, posts and struts. |
| 41 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete ( Thermo-Mechanically Treated bars of grade Fe-500D or more). |
| 42 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 43 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 44 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) :(First class kail wood) |
| 45 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-chargeIst class kail wood 35mm |
| 46 | Providing and fixing 35mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : First class kail wood |
| 47 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 48 | Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete (125 mm) |
| 49 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete : Welded |
| 50 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters( 80x1.25 mm M.S. laths with 1.25 mm thick top cover) |
| 51 | Providing and fixing ball bearing for rolling shutters. |
| 52 | Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required : 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 53 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2 |
| 54 | Providing and fixing plained eaves boarding.250x32 mm (nominal size ) |
| 55 | 12mm Cement plaster of mix: ( 1 cement : 4 fine sand) |
| 56 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 57 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content : With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ liter) |
| 58 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 59 | Providing and laying non-pressure of specified class R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement: 2 fine sand) including testing of joints etc. completeNon pressure NP4 class (heavy duty) RCC pipes. 1200 mm dia. R.C.C. pipe (laying by manual/mechanical means) |
| 60 | Providiing installation, commissioning and testing of single Winch Machine, complete set of standard quality of 3 Ton capacity with double threaded 50mm dia winch rod, gears, padesteal raincover, greese lids, MS Seleves, operating handle with locking arrangements incl greasing and oiling incl all sorts of carriages(Manual/ Mechnical) Complete Job |
| 61 | Providing and fixing of rubber seal to gates for checking of leakages of standard quality with 25x.5mm with plate iron steps including nuts and bolts complete job |
| 62 | Carriage of materials by mechanical transport from source to road site of work including loading, unloading and stacking.Stone soling a) Stone soling from Av. 13 km |
| 63 | b)Stone soling from Av. Lead 20 Km |
| 64 | Stone Aggregates(40mm)a) 40mm Stone Aggregate from Ganderbal avg lead 13 km |
| 65 | b) 40mm Stone Aggregate from Ganderbal avg lead 20 km |
| 66 | Stone Aggregates(20mm) (a) 20mm Stone Aggregate from Ganderbal avg lead 13 km |
| 67 | b) 20mm stone aggregates from avg lead 15 km |
| 68 | c) 20mm Stone aggregates from Avg lead 20 Km |
| 69 | Sanda) Sand from Shadipora Av. Lead 1 km |
| 70 | b) Sand Av. Lead 3 km |
| 71 | c) Sand Av. Lead 5 km |
| 72 | Bricksa) Bricks from Budgam Av. Lead 28 km's |
| 73 | RCC Pipea) RCC pipe 1200mm for an average lead of 05 Km Please Enable Macros to View BoQ information |