| 1 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth and getting out for laying of pipe lines in any type of soil. |
| 2 | Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm each in soil. |
| 3 | Removal of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point. |
| 4 | M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in foundations/foot path etc complete all as specified and directed by Engr-in-Charge. |
| 5 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness below or above gound level including removal of debris complete all as specified and directed. |
| 6 | M&L for taking up or down steel water tubing and connections of 15 mm dia including cleaning for refixing complete all as specified and directed |
| 7 | Discription all as item No 6 here in before but of size 20 mm bore. |
| 8 | Discription all as item No 6 here in before but of size 25 mm bore. |
| 9 | Discription all as item No 6 here in before but of size 40 mm bore. |
| 10 | Discription all as item No 6 here in before but of size 50 mm bore. |
| 11 | Discription all as item No 6 here in before but of size 80 mm bore. |
| 12 | Discription all as item No 6 here in before but of size 100 mm bore. |
| 13 | Re-laying / re-fixing galvanised mild steel water tubing of 15 mm bore with and including all fittings laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed. |
| 14 | Discription all as per item No 13 here in before but of size 20 mm bore |
| 15 | Discription all as per item No 13 here in before but of size 25 mm bore |
| 16 | Discription all as per item No 13 here in before but of size 40 mm bore |
| 17 | Discription all as per Item No 13 here in before but of size 50 mm bore |
| 18 | Discription all as per item No 13 here In before but of size 80 mm bore |
| 19 | Discription all as per item No 13 here In before but of size 100 mm bore |
| 20 | S & F galvanised steel water tubing medium grade 15 mm bore with all fittings such as bends, elbow, socket etc lad under floors/trenches or on walls with all fixing arrangments including leakage testing as per is 97684 complete all as specified and directed. |
| 21 | Discription all as per item No 20 here In before but of size 20 mm bore |
| 22 | Discription all as per item No 20 here In before but of size 25 mm bore |
| 23 | Discription all as per item No 20 here In before but of size 40 mm bore |
| 24 | Discription all as per item No 20 here In before but of size 50 mm bore |
| 25 | Discription all as per item No 20 here In before but of size 80 mm bore |
| 26 | Discription all as per item No 20 here In before but of size 100 mm bore |
| 27 | S & F in replacement of brass ball valves of size 15 mm bore ISI marked with iron wheel head, screwed both ends for iron pipe incl dismantling old U/s gate valve all as specified and directed |
| 28 | Discription as per item No 27 here in before but 20 mm bore |
| 29 | Discription as per item No 27 here in before but 25 mm bore |
| 30 | Discription as per item No 27 here in before but 40 mm bore |
| 31 | Discription as per item No 27 here in before but 50 mm bore |
| 32 | Supply only Calcium Hypochlorite 65% to 70% chlorine content in packed with 45 Kg each drum (calcium based granular disinfectant for water treatment much more stable than chlorine gas and stronger than bleaching powder & sodium hypochlorite complete all as specified and directed. Make : Aquafit or equivalent as approved by NMPT committee of E-in-C's Branch.Note :-The contractor must submit the COC (Certificate of Compliance) in original from manufacturer by All India Authorised MES Distributor for each batch of product delivered indicating and including Chemical Analysis Report by All India Authorised MES Distributor. Note :- 1. The contractor must submit the COC (Certificate of Compliance) in original from manufacturer for each batch of product delivered including chemical analysis report. Contractor has to get approval of Accepting officer before placing purchase order . |
| 33 | S & F cast iron foot valves with flanged end in replacement of 80 mm bore all as per including necessary rubber gasket, MS nuts, bolts, washers etc of suitable size complete all as specified and directed. Make:-Kirloskar/leader/upadhayay/sant |
| 34 | S & F cast iron foot valves with flanged end in replacement of 50/65 mm bore all as per including necessary rubber gasket, MS nuts, bolts, washers etc of suitable size complete all as specified and directed.Make:-Kirloskar/leader/upadhayay/sant |
| 35 | S & F cast iron foot valves with flanged end in replacement of 100 mm bore all as per including necessary rubber gasket, MS nuts, bolts, washers etc of suitable size complete all as specified and directed.Make:-Kirloskar/leader/upadhayay/sant |
| 36 | M & L for cutting of GI/DI/CI pipe 80 to 150 mm bore carefully for inserting fittings such as bend, tee, socket pieces, collar etc complete all as specified and as directed. |
| 37 | M & L for cutting and removing unwanted grass, wild growth incl bushes and shrubs from the roots below ground level at various over head tanks premises about 15 mtr radious with approaching road and removing boulders from a depth not more than 25 cms below normal ground level and depositing where directed and levelling / pruning the entire cleaned area to even finish complete all as specified and directed at site. |
| 38 | S&F in replacement of 20 mm Ball valves (float valve) PTMT ,high pressure , with polythene float and fly-nut complete screwed for iron pipe suction pipe, including nut bolt & washers for joints and jointing material complete all as specified and as directed by Engineer in Charge. |
| 39 | Supply and fix water pipe line route indicator made of size 400 x 300 x 25mm of precast RCC (1:2:4) type B-O using 12.5 mm graded stone aggregate complete all as specified and directed. Note :- Route indicator should be writen as main water supply line complete as directed by Engr-in-Charge. |
| 40 | M&L for collecting the sample of water from differeent pump houses and testing the sample for physical, chemical & bacteriological parameters from NABL accredited Lab and submitting the report in duplicate with comparison by IS-10500, complete for 29 parameter all as specified and directed by Engr-in-charge |
| 41 | Supply, install, testing and commissioning in repairs of Pressure vessel with bladder suitable for capacitor start monoblock pressure pump upto 1 HP capacity including taking down the existing unserviceble one.Old Pressurevessel deposited to MES store make: Kirlosker,Texmo.Cromton,CG |
| 42 | Supply,and fixing in repairs of Electronic controlling device (pressure switch) as per existing sample including suitable for capacitor start monoblock pressure pump upto 1 HP capacity including taking down the existing unserviceble one. |
| 43 | M & L for cutting of stone block pavement/road a depth up to 1.5 mtr below the normal ground level and in width equal to external dia plus 300 mm for lay pipe line upto 300 mm dia across the road in horizontal position and making good the cut portion filled with PCC 1:3:6 type C-2 using 40 mm graded stone aggregates 450 mm thick from TOP over 300 mm thick hard core over filled earth to levelled with existing surfaces for smooth plying of vehicles etc complete all as specified and directed. The repaired portion will be match to the existing surface. Note• Cost of PCC ,hard core,stones and Earth shall deemed to be included in unit rate quoted by the tendered. |
| 44 | S & F in repairs GI fittings i.e bends, reducer, tail pieces, tapers, tees, caps and plugs with MS plate, nuts, bolts washers etc for size 40 to 75 mm bore complete all as specified and as directed. |
| 45 | S & F in repairs GI fittings i.e bends, reducer, tail pieces, tapers, tees, caps and plugs with MS plate, nuts, bolts washers etc for size 40 to 75 mm bore complete all as specified and as directed. |