| 1 | Supply and fixing of fire fighting Jockey pump 25 HP eletrically driven horizontal end suction, centrifugal type confirming to IS-12469:1988 with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for contionus automatic operation with non over loading power characteristic for frequent start / stop with range of operation with range of operation 0 % to 150 % of rated capacity for 440V, 3 phase , 50 Hz 70 M head , 180 LPM discharge complete with mounted on MS Channel and PCC Foundation and covered with proper GI galvalume roof shed protect from rain water and direct sun light complete with out door type panel having fully Automatic star delta starter with metering and control units and operated on prresuure switch fix on line including 01 No of pressure switch with conncetion cable from switch to starter and 16 Sqmm 3 core submersible flat/round cable connection from starter panel to motor of Min 40 Mtr length complete all as specified and directed Note: Make and capicity of Jockey pump 25 HP shall be approved by GE as per list of make.) |
| 2 | Supply and fixing of open well 10 HP Submersible pump, electric driven 415 V, TP suitable complete with self priming and 40 Mtr head and 450LPM (min) complete with out door type panel having fully star delta starter with metering and control units and operated on pressure switch fix on line including 01 No pressure switch with conncetion cable from switch to starter and 6 Sqmm 3 core submersible flat/round cable connection from starter panel to motor of Min 40 Mtr length complete all as specified and directed. Note: Make and capicity of Submersible pump 10 HP shall be approved by GE as per list of make.) |
| 3 | Supply and fixing of open well 15 HP Submersible pump, electric driven 415 V, TP suitable complete with self priming and 40 Mtr head and 1500 LPM (min) complete with out door type panel having fully star delta starter with metering and control units and operated on pressure switch fix on line including 01 No pressure switch with conncetion cable from switch to starter and 10 Sqmm 3 core submersible flat/round cable connection from starter panel to motor of Min 40 Mtr length complete all as specified and directed. Note: Make and capicity of Submersible pump 15 HP shall be approved by GE as per list of make.) |
| 4 | Supply and laying of GI steel tubing 80 mm bore 'medium grade' laid on wall or trenches including fittings & fixture complete all as specified and directed. |
| 5 | Supply and fixing of MS ERW 'medium grade' steel pipe with rapping coating protect from corrosion including specials fittings as required at site, nominal dia 100 mm for laying and lowering in open well or bore well complete all as specified and directed. |
| 6 | Supply and fixing of MS ERW medium grade steel pipe with rapping coating protect from corrosion including specials fittings as required at site, nominal dia 80mm for laying and lowering in open well or bore well complete all as specified and directed. |
| 7 | Supply and fixing of MS ERW medium grade steel with rapping coating protect from corrosion including specials fittings as required at site, connect incoming and out going connection laying or lowering in open well or bore nominal dia 150 mm complete all as specified and directed. |
| 8 | Supply and fixing of Non return valve 80 mm dia and including rubber gasket, nut bolts etc complete all as specified and directed. |
| 9 | Supply, fixing, jointing & testing butterfly valve (wafer type) of 80mm bore as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, complete all as specified and as directed at site. Note:- Jointing material shall deemed to be included in the quoted unit rate of this item. |
| 10 | Supply, fixing, jointing & testing butterfly valve (wafer type) of 100 mm bore as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, butterfly valve complete all as specified and as directed. Note:- Jointing material shall deemed to be included in the quoted unit rate of this item. |
| 11 | Supply, installation and testing flanged ends strainer/dirt box of 80/100 mm bore with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclined/vertical position complete all as specified and directed at site. Note :- Flange joints including jointing materials shall deemed to be included in the quoted unit rate of this item. |
| 12 | Supply & Fixing of 63 mm dia SS branch pipe with 12.5/15 mm dia nozzle conforming to IS 903 complete all as specified and directed. |
| 13 | Supply & Fixing of 63 mm dia Hydrant valve (landing Valve) single headed stainless steel with 1.5 mtr height hydrant post of 80 mm dia pipe complete with all fittings and fixture, rubber gaskets incl 01 No of 80 mm dia butter fly valve on post etc complete all as specified and directed |
| 14 | Supply and fixing of 63 mm dia 15 mtr long hose pipe conforming to IS 636 complete with male and female coupling stainless steel conforming to BIS 903 complete all as specified and directed. |
| 15 | Supply and fixing of hose box for keeping 2 Nos house pipe of length 30 meter each , branch pipe, nozzle , coupling etc. of MS sheet of thickness 2.0 mm complete all as specified and directed. |
| 16 | Supply& fixing/ laying and testing, commissioning of LT XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed.(Note: Excavation and earth work shall be measured and paid seperately under respective item) |
| 17 | Excavation in trenches soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of pipes/cables etc and getting out in soft/loose soil and bottom surface to be required gradient complete all as specified and directed |
| 18 | Returning filling in including spreading leveling watering and well ramming in layers each not exceeding 25 cm thickness complete all as specified and directed |
| 19 | Removal of surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed |
| 20 | Supplying, filling ganga river sand in trenches, spreading, leveling and cushioning 8 cm below cable and 15 cm above the cable for under ground cable complete all as specified & directed. Note: Punned depth of sand only shall be measured and paid) |
| 21 | Supply and laying of Old Size sub class 'B' bricks,laid flat in trenches over the cable with length of brick perpendicular to the direction of the cable , adjacent/abutting each other complete all as specified and directed |
| 22 | Supply and fixing of first aid hose reel 20mm dia with 30 mtr long pipe with nozzle mounted on wall or inside the box complete with 01 Nos 25 mm dia valve at inlet connection complete all as specified and directed |
| 23 | Supply and fixing of GI pipe 25 mm bore medium grade including fittings & fixtures and laid on wall or trenches complete all as specified and directed. |
| 24 | Supply, installation, testing and commissioning of air cushion tank fix out side area with suitable rain water protection complete with connect with suitable pipe line and safety valve from header complete all as specified and directed. Supply only liquid water proofing compound of approved quality and make confirming to IS complete all as specified and directed. Please Enable Macros to View BoQ information |