| 1 | Cementing : Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). |
| 2 | LT CABLE Supplying, erecting & terminating XLPE armoured cable 3½ core 120 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 3 | Supplying & laying (including excavation) reinforced cement concrete pipe of IS458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slopeincluding providing and fixing collars in cement mortar 1:2 and curing etc.complete. |
| 4 | Supplying and erecting all aluminium stranded conductors 7/3.10 mm.complete. (Ant.) (145.0 kg/km) as per specification No. OH-CON/AAC |
| 5 | Supplying and erecting porcelain disc type insulator 45KN with necessaryhardware suitable for 11kV line, complete as per specification no. OH-INS/DI |
| 6 | Supplying and erecting porcelain pin type insulator with GI pin suitable for11kV line, complete as per specification no. OH-INS/PN |
| 7 | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m)with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 8 | Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kVHTOHline with arrangement to fix insulator at 45mm from the end & horizontaldistance between insulators 1220mm bent at angle of 60 degree keeping base305mm and the total vertical height of V cross arm as 460mm, and fixed on polewith MS clamp of 80x10 mm, nut bolts, washers complete as per specification no.OH-PL/VCA |
| 9 | Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 100 kVATransformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long withsuitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200Amps as incomer & 6 Nos.100 Amps Kitkat / MCCB for out going circuits.Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set &L.A. Set. 2 Nos. Top channel of size 100 mmx 50 mm for erection of A.B. Switch& 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer.Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handleetc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Beltetc.as per drawing (min. 124 Kg. iron work) with necessary clamps, Nut-bolts. Vcross arm, top clip, insulators etc. complete with caution board & barbed wire.D.P. Structure shall be erected in c.c. foundation complete. |
| 10 | Transformer Supplying, installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz., 100 kVA, oil immersed and naturally cooled outdoor type, Aluminium wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oC by thermometer in oil and 45oC by the resistance in winding at full load rating, with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, with standard accessories complete with test certificate with losses below 475 Watts at 50% load, 1650 Watts at 100% load as per IS:1180 - 2014 energy efficiency level II, with necessary permissions of Electrical Inspector, as per specification no SS- TR. |
| 11 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/10 SWG, G.l. stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation. |
| 12 | Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 13 | Supplying and erecting PVC trunking (PVC casing-ncapping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON |
| 14 | Supplying and erecting PVC trunking (PVC casing-ncapping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON |
| 15 | Supplying & erecting mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW |
| 16 | Supplying & erecting mains with 1x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW |
| 17 | Supplying & erecting mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW |
| 18 | Supplying & erecting mains with 1x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW |
| 19 | Supplying & erecting mains with 2x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW |
| 20 | Supplying & erecting mains with 1x4 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW |
| 21 | Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 22 | Supplying, erecting & terminating XLPE armoured cable 3½ core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 23 | Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 24 | Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete |
| 25 | Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 26 | Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete |
| 27 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 modules duly erected. |
| 28 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 modules duly erected. |
| 29 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 modules duly erected. |
| 30 | Wiring for plug on board with Switch socket surface/concealed type, copperwiring and earthing and with modular accessories as per specification No: WGPW/CW |
| 31 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 32 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WG-PW/SW |
| 33 | Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW (note- concealed point wiring item is considered for futute provisions proposed by authority, if any) |
| 34 | Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete &compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary. |
| 35 | Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. (note- concealed light item is considered for futute provisions proposed by authority, if any) |
| 36 | Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22/E-27 base. |
| 37 | Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden |
| 38 | Supplyinganderectingregular/standardmodel ceilingfanof900/1050mm. sweep complete erected in position as per specification no. FG-FN/CF |
| 39 | Supplying and erecting „B‟ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. |
| 40 | Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. |
| 41 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner. |
| 42 | Providing recess in brick wall suitable for erection of exhaust fan up to 450mm. sweep complete with grouting of nut, bolts, plastering and colour washing to match the colour of the wall for the wall thickness of 225 mm. |
| 43 | Supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room airconditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 tomaximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no ofair handling unit hi-wall/floor mounting type complete with refrigerant R32having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizerfree operation & temperature display on indoor unit, noise level maximum 50dBAat position as per specification no. APAC/ WAC |
| 44 | Supplying and erecting fully automatic line voltage stabilizer buck and boosttype for operation on input voltage 160-270V and output voltage 200-250V ratedfor 3kVA maximum load and with voltmeter, selector switch, 6A/16A flush type3 pin socket for output and with 3 core copper flexible cord and 3 pin 6/16A plugtop with overload & short circuit protection complete |
| 45 | Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC. ' |
| 46 | Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. |
| 47 | Supplying and erecting PVC Surfacemodular switch box with double mounting plate for 2 module duly erec |
| 48 | Supplying, erecting & marking SPMCB 6A to 32A, B-series in provided distribution board as per specification no. SW-SWR/MCB |
| 49 | Supplying, erecting & marking SPMCB 6A to 32A, C-series in provided distribution board as per specification no. SW-SWR/MCB |
| 50 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as perspecification no. SW-SWR/MCB |
| 51 | Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SW-SWR/MCB |
| 52 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 53 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB |
| 54 | Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP |
| 55 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP. |
| 56 | Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breakingcapacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixedmagnetic setting with provided leads, provision for installation of shunt/UV/tripalarm contact. MCCB with phase barriers on both sides, insulation withstandcapacity 800V, no line-load bias in provided enclosure/panel as per specificationno. SW-SWR/MCCB (added 20% to the cost of 3 pole mccb for 4 pole ) |
| 57 | Providing, erecting & commissioning 4 pole RCCB of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 100A, complete as per specification no. SW-RCCB/RCCB |
| 58 | Supplying and erecting bus bar chamber triple pole with neutral with fouraluminium bars, 500V 200A having 25mm (Width) X 5 mm (Thickness) , with99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A persq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCAsheet and epoxy paint, with suitable number of ways and with SMC/DMCInsulators and accessories of suitable rating complete as per specification no. CPBB |
| 59 | Supplying & erecting CRCA sheet metal one way enclosures suitable for D.P.M.C.B. /T.P. M.C.B. /F.P M.C.B. complete erected on angle iron/ G.I. frame. |
| 60 | Supplying and erecting GI sheet 1.6 mm (16 SWG) to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. Distrubution Panel |
| 61 | Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 4 pole upto 100A MCCB complete. (Set of 8) |
| 62 | Supplying and erecting terminal spreaders for use on MCCB incoming and outgoing terminals for 4 pole above 100A upto 250A MCCB complete. (Set of 8) |
| 63 | Providing & erecting prewired meter module suitable for MCCB panel board with CT's and emf's VIF meter complete. |
| 64 | Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc |
| 65 | Supplying & erecting LED type indicating pilot lamp with LED colours blue, 230 / 250V on provided box / panel with necessary material, wiring & connections etc |
| 66 | Supplying & erecting four pole ON LOAD change over switch, 415V, 100A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 |
| 67 | Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 2500 VA digital pure sine wave inverter with backup time of .6. hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV |
| 68 | Supplyinganderecting12V/200Ahtubularbatterywithbattery terminalwire, duly charged with 36 months warranty complete |
| 69 | Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.(note - |
| 70 | Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB |
| 71 | Supplying & erecting FRP box of size 250 x 200 x 100 mm, 2.7 mmthick complete on pole/wall as per specification no. CB-SB |
| 72 | Supplying, erecting & terminating XLPE armoured cable 4 core 6sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12SWG) G.I. earth wire complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no.CB-LT/AL |
| 73 | SupplyinganderectingPVCinsulatedPVCroundsheathed1.5sq.mm(30no.x 0.25mmdia.)3coreflexiblemultistranded copperIndustrialcableforvoltage grade up to 1.1 kV |
| 74 | Supplying & erecting single phase, 240V, street light control panel up to the max load of 6kW, SPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame/ CC foundation. Please Enable Macros to View BoQ information |