| 1 | Dismantling of following type of road surfaces for laying of pipe line and house connection work including sorting out of serviceable materials and disposal of unserviceable materials. |
| 2 | Cement concrete Road |
| 3 | Interlocking Tiles Road |
| 4 | Excavation for pipeline in ordinary soil (loam, clay, sand) with lift up to 1.5 m and lead up to 50 m and including filling back, watering and ramming of excavated earth into the trenches and removal and disposal of surplus earth within 50 meters.0 to 1.5 m depth |
| 5 | Supply of High Density Polyethelene Pipes (HDPE (PN-6)/PE-100), conforming to IS 4984 / 14151 / 12786 / 13488 in coils/ standard lengths F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation chaloading & stacking the same etc. complete.160 mm (HDPE (PN-6)/PE-100) |
| 6 | 110 mm (HDPE (PN-6)/PE-100) |
| 7 | Lowering, laying and jointing of HDPE pipe in proper position using electrofusion specials including supply of all Electrofusion specials & hydraulic testing as per relevent IS Code complete with all accessories like Electrofusion machine, power arrangements, hydraulic testing arrangements, labours, material etc. complete.160 mm (HDPE (PN-6)/PE-100) |
| 8 | 110 mm (HDPE (PN-6)/PE-100) |
| 9 | Provision for crossing of Nalas (0.5m to 2.0 m width) for laying of pipe line including necessary specials, T&P and arrangement of diversion of water, baricatings etc required, with dismantling of drains and reconstruction of same as per type design of the existing drain. |
| 10 | 1.0 - 1.5 m (Clear Span) |
| 11 | 1.0 - 1.5 m (Clear Span) |
| 12 | Interconnection between following dia of pipe including cutting of old pipe line, dewatering, making proper space to work, including supply of all labour, material & T/P etc. complete required for proper completion of work. |
| 13 | Interconnection 160x160(160x110) mm dia |
| 14 | Interconnection 90x90(110X110) mm dia |
| 15 | Disposal of surplus earth and other similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, etc complete required for proper completion of the work. |
| 16 | Reinstatement of following type of road surfaces after laying of pipe line and house connection work including supply of all materials, T&P etc. required for proper completion of the work as per direction of engineer-in-charge. The quantity of reinstatement has been increased by thirty percent in the view of additional damaged of dismantled road due to traffic / vehicle movement. |
| 17 | Cement Concrete RoadConstruction of Cement Concrete road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:3:6 (cement, coarse sand & stone ballast of 20-40 mm) CC =100 mm, 1:1.5 :3 (cement, coarse sand & stone ballast of 16-20 mm) |
| 18 | C.C. Interlocking Tiles Road Type AConstruction of C.C. Interlocking Tile road including supply of all materials, labour, T&P etc. required for proper completion of work as per following thickness:-PCC = 100 mm,1:4:8 (cement, coarse sand & stone ballast of 20-40 mm)Sand = 30mm to 50mm thick local sand lair for preparation of surfaceTiles = 50% new + 50% oldNote : 100 mm thick rubber moulded interlocking tile shall be used for construction of interlocking tile road. |
| 19 | Supply of following type of valves as per specifications F.O.R. desination rates per meter (exclusive of GST) in Rs. every where in UP upto stores of consignees inclusive of third party inspection charges, packing and forwarding charges, transit insurance charges, road transportation charges, unloading & stacking the same etc. complete. |
| 20 | 150 mm |
| 21 | 50mm dia Air valves as per IS 14845 : 2000 |
| 22 | Carting, lowering, laying, aligning, fixing in position and installation of following valves in pipe line including all material, labour, testing and commissioning as perdirection of Engineer-in- charge. |
| 23 | 150 mm dia |
| 24 | 50mm dia Air valves as per IS 14845 : 2000 |
| 25 | Supply of all materials, labour, T&P etc. required for construction of following masonry type chambers as per type design.Construction of a masonry chamber 600X600X750 inside size with cover, all complete |
| 26 | Air Valve Chamber (Size 0.8 x 0.8 x 0.8) |
| 27 | House connection for water Supply-20mm dia (OD) MDPE pipe (12.5 kg/sqcm), Service Saddle (Brass Thread), Ferrule brass 15mm with end cap (heavy duty)ISI mark, FTA Brass thread (For 20mm MDPE pipe and Brass ferrule), FTA Brass thread (For 20mm MDPE pipe and Brass ferrule), FT Elbow Brass Thread (for 20 mm MDPE pipe), Plug ( For FT Elbow),Clamp (For 20 mm MDPE pipe) etc Including labour work.Material should be of statndard quality.Upto 110 mm dia |
| 28 | For 125 mm to 160 mm dia |
| 29 | P&F of Inauguration stone Board in all complete |
| 30 | Add 18% GST Please Enable Macros to View BoQ information |