Name of Work:- RRD of LWSS Patbag Linjhan in Tehsil Pal ur Distt. Kangra (HP) (SH:- Repair of 5 Hp & 30 HP auto starter panel)
Sl. No.
Item Description
1
Replacement & Installation of electronics instruments 5 HP X 1 X 2 Starter having panel serial no. AEPL/ ECP/ 2022-23/ 172 Replacement of energy saving variable Frequency module of 5 HP X 1 X 2 Heavy duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be capable to monitor & control the frequency of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 degrees celcius without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc.
2
Replacement & Installation of Multifunction meter to showing the degital opration like Amp. Voltage, frequency, PF Complete in all respect as per the direction of Engineer in charge with in all leads and lifts.
3
Replacement and installation of surge Protection Device used for safeguard sensitive electronic equipement from voltage spikes and surge. They are crucial for protecting against voltage inconsistencies caused by lightning strikes, Power surge or electrical malfunctions complete in all respect as per direction of Engineer in charge with in all leads and lifts.
4
Replacement & installation of LED Three phase indicating lamps complete with logged switches for individual motors confirming to BIS 3452 (Part I & II) Latest with upto date ammendments. complete in all respect as per direction of Engineer in charge with in all leads and lifts.
5
Labour and service charges complete in all respect as per direction of Engineer in charge with in all leads and lifts.
6
Repaired and replacement of electronics instruments of 30 HP X 1 X 2 Starter having panel serial no. AEPL/ ECP/ 2022-23/ 172 Replacement of Energy saving variable Frequency module of 30 HP X 1 X 2 heavy duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It should be cabable to monitor & control the frequency of pumps through out the operation and to maintain the power factor of the system within acceptable limits. It should be able to withstand ambient temperature upto 50 degrees celcius without derating and have conformal coating class 3C2, So that it can work in any harsh environment like moisture etc. complete in all respect as per direction of Engineer in charge with in all leads and lifts. Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.