| 1 | Supplying at store or site of work including railway freight, carting, loading and unloading, stacking etc. Centrifugally cast, (spun) ductile iron pressure pipes (with socket/spigot ends) conforming to IS: 8329-2000 with cement mortar lining inside the pipe and outside zinc coat as per IS: 8329-2000 with up to date amendments suitable for jointing with rubber gasket known as TYTON joints. Class K-9 .; Nominal Diameter in mm ; 200 |
| 2 | Supplying at store or site of work including freight, loading, unloading and stacking at site Oriented PVC (PVC-O) ring fit type pipes having orientation class 500, conforming to ISO 16422-2014, and IS 16647-2017, with integral homogeneous spigot having elastomeric sealing ring made of EPDM rubber (one per pipe). PN 16; Size in mm -OD; 110 |
| 3 | Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. Tamper proof double acting air valve conforming to AWWA C-512, with tamper proof air vents and SS:304 floats with isolating sluice valve confirming to IS:14846 flanges drilled as per IS:1538, PN 1.0.(Class A); Dia in mm; 50 |
| 4 | Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. Cast iron double flanged manually operated Sluice Valve generally conforming to IS: 14846 - 2000 having body, door, dome, gland in graded cast iron to IS:210 Gr. FG 200Min., four faces and spindle nut of leaded tin bronze to IS:318 Gr. LTB 2, inside screw of non-rising stainless steel AISI410, spindle, Flanges drilled to IS:1538 Table 4 & 6. Valves tested by closed end method only (350mm and above will be fitted with BTB and Spur gear box. and back seat bush) TYPE P.N. 1.0 (Class A); Nominal Diameter in mm; 100 |
| 5 | Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. Cast iron double flanged manually operated Sluice Valve generally conforming to IS: 14846 - 2000 having body, door, dome, gland in graded cast iron to IS:210 Gr. FG 200Min., four faces and spindle nut of leaded tin bronze to IS:318 Gr. LTB 2, inside screw of non-rising stainless steel AISI410, spindle, Flanges drilled to IS:1538 Table 4 & 6. Valves tested by closed end method only (350mm and above will be fitted with BTB and Spur gear box. and back seat bush) TYPE P.N. 1.0 (Class A); Nominal Diameter in mm; 200 |
| 6 | Supplying at store or at site of work cast iron specials for mechanical and push on flexible joints as per IS:13382 - 1992 including Sealing rubber gaskets (NR), CI compression glands and coated MS Nuts bolts.; Double Socket Branch Flange Tee; Nominal Dia in mm; 250x250x200 |
| 7 | Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete.; Double Socket Tee with Branch Flange; Nominal Diameter in mm ; 200x100 |
| 8 | Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete.; Double Socket Bend 45 Degree ; Nominal Diameter in mm ; 200 |
| 9 | Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete.; Double Socket Bend 22.5 Degree ; Nominal Diameter in mm ; 200 |
| 10 | Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete.; Double Socket Reducer ; Nominal Diameter in mm ; 200x100 |
| 11 | Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete.; Flanged Socket ; Nominal Diameter in mm ; 100 |
| 12 | Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete.; Flanged Socket ; Nominal Diameter in mm ; 200 |
| 13 | Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete.; M.J.Collar; Nominal Diameter in mm ; 100 |
| 14 | Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete.; M.J.Collar; Nominal Diameter in mm ; 200 |
| 15 | Conveying carefully from stack at site, 250m from both sides rolling and lowering in trenches, laying and jointing true to line and level and perfect linking of joints; Cast iron or Ductile iron or A.C. or S & S or flanged & PVC pipes. |
| 16 | Conveying carefully from stack at site, 250m from both sides rolling and lowering in trenches, laying true to line and level and perfect linking for joints for P.V.C / H.D.P.E complete in all respects as per the direction of the engineer in-charge; 110 mm OD |
| 17 | Jointing of rigid / SEL FIT PVC pipes by cleaning the pipe with solvent cement including the cost of solvent cement and hydraulic testing of joints etc. complete as per IS:7634-1975 Part 3, including hydraulic testing of joints as directed by the Engineer in-charge.; Outer Diameter in mm; 110 |
| 18 | Jointing of C.I/D.I pipes and specials with rubber gaskets (TYTON joints) EPDM type including cleaning the socket and spigot ends with kerosene oil/below lamp and applying soft soap to socket and spigot ends before inserting for rubber gasket jacking and fixing in proper condition including cost of rubber gasket, oil, soft soap and hydraulic testing of jointing as per IS:3144-1985.; Nominal diameter in mm; 200 |
| 19 | Hoisting laying cast iron sluice valves/butterfly valves/reflux valve of size given below at location in pipeline etc. complete as directed as per IS:2685-1971 CLASS I; Nominal diameter in mm.; 100 |
| 20 | Hoisting laying cast iron sluice valves/butterfly valves/reflux valve of size given below at location in pipeline etc. complete as directed as per IS:2685-1971 CLASS I; Nominal diameter in mm.; 200 |
| 21 | Fixing C.I. Tamper proof Kinetic double orifice type air valve. Small orifice elastic ball resting on bronze orifice nipple and large orifice vulcanite ball resting on moulded seat ring with built in Kinetic features of isolating sluice valve of rating P.N. 1.6 with ISI mark mounted on a horizontal mounting operated by metered wheel gear suitable for working pressure of 10 kg / sq. cm; Fixing C.I. Tamper proof Kinetic double orifice type air valve. Small orifice elastic ball resting on bronze orifice nipple and large orifice vulcanite ball resting on moulded seat ring with built in Kinetic features of isolating sluice valve of rating P.N. 1.6 with ISI mark mounted on a horizontal mounting operated by metered wheel gear suitable for working pressure of 10 kg / sq. cm; 50 |
| 22 | Hydraulic testing of pipeline as per CLAUSE NO 6.4.4 of CPHEEO MANUAL on water supply and treatment, to the required test pressure by providing all work force, materials, reciprocating pump, pressure gauge, including the cost of water required, maintaining the test pressure for a period of 24 hours from the time the pipe line has attained the test pressure for successful testing, as per the standards, required as per the direction of the engineer in-charge for ductile Iron/ Mild steel/cast iron pipeline.; 200mm |
| 23 | Construction of masonry chamber 90x90x100 cm inside in 40kg/sq. cm brickwork complete with 23 cms wall thickness and in cement mortar 1:4( 1 cement : 4 coarse sand) for sluice valve of sizes 100 mm, 120 mm 150 mm and 200mm dia with necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 coarse sand: 10 graded stone ballast 40 mm nominal size) and inside plastered with CM 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement complete and chamber cover as specified below etc. all complete as per standard drawing . (rate is inclusive of rate earthwork excavation, cost of surface cover and all other materials and labour and as per details below); with M.S. sheet cover with 12mm thick M.S. plate and frame of Angle iron 50x50x6mm in 120 mm thick RCC slab cover in cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone ballast 20 mm nominal size) |
| 24 | Providing & laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in:; All works upto plinth level |
| 25 | Cutting the bituminous road for laying the pipeline in trenches including labour, tools, etc. and disposing the excavated excess material from the trench to a distance of 1000 metres, including making level the trench surface by utilising the serviceable material to the level of the top surface of road, by compacting, watering ramming with rolling with road roller after completion of laying of pipe and refilling the trenches etc. complete as per the direction of engineer in charge.; By Manual Means :; District Road, State highways, National highway and roads of similar standards |
| 26 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation pipeline trenches, drains not exceeding 1.5 m in width 10sq.m on plan including dressing of sides ramming of bottoms for all lift including getting out the excavated soil & disposal of surplus soil for all lead and in all types of soft stratas comprising any of the materials such as soil, silt, sand, clay, gravel, moorum of all varieties shingles, pebbles all types of conglomerates, laterite rocks, ordinary rocks, soft rock disintergrated rocks, fissured, shuttered/decomposed rock, weathered rocks and all such other materials as described under appendix A to these specification either in full or in parts as the case may be adopting any method / methods as may be convenient or permitted inclusive of chiseling, wedging etc, blasting prohibited and in all conditions such as dry , moist , foul, saturated submerged etc including providing barricading, danger lighting guarding and as per the direction of the Engineer-in-charge etc. |
| 27 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 28 | Repairs and reinstatement to the road for trenches made by laying water supply pipeline, by removing the refilled material in the trench for the total depth of 0.42m and making good the road surface by providing laying rollling by road roller compacting for laterite soling 30cm thick, two layer of full grout of 50mm thick each, tack coat and open graded premix carpet of 20mm thickness as per specifications mentioned in item nos 14086, 14093, 14051 & 14068 of road GSR respectively, complete as per the direction of the engineer incharge.; District Road, State highway, National highway and roads of similar standards |
| 29 | Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge. |
| 30 | Making connection to individual 15mm /20mm/25mm G.I/ OD Blue PVC pipeline with existing distribution line of any diameter with saddle piece / and necessary pipe and specials required suitable to the distribution line with road cutting trenching refilling the same including the cost of labour and accessories etc. complete. as per the direction of Engineer -in- charge. |
| 31 | Construction of masonry chamber60x60x75cminside in 40kg/sq. cm ,brickwork complete with 23 cms wall thickness and in cement mortar 1:4( 1 cement : 4coarse sand) for sluice valves 50 to 80mm with necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 coarse sand: 10 graded stone ballast 40 mm nominal size) and inside plastered with CM 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement complete and chamber cover as specified below etc. all complete as per standard drawing . (rate is inclusive of rate earthwork excavation, cost of surface cover and all other materials and labour and as per details below); with M.S. sheet cover with 12mm thick M.S. plate and frame of Angle iron 50x50x6mm in 120 mm thick RCC slab cover in cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone ballast 20 mm nominal size) Please Enable Macros to View BoQ information |