Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: |
| 2 | Private car, auto-rickshaw or similar with 1.0 km lead |
| 3 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 4 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 5 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 6 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 7 | Load carrier auto, mini van or similar with 1.0 km lead |
| 8 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 9 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 10 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 11 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 12 | Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead |
| 13 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 14 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 15 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 16 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 17 | Truck, tipper or similar with 1.0 km lead |
| 18 | Extra per kilometer for lead >1.0 kms upto 5.0 kms |
| 19 | Extra per kilometer for lead >5.0 kms upto 10.0 kms |
| 20 | Extra per kilometer for lead >10.0 kms upto 20.0 kms |
| 21 | Extra per kilometer for lead >20.0 kms upto 30.0 kms |
| 22 | Head load carriage of machinery/ equipment at locations inaccessible by vehicles on plain/ rough terrain |
| 23 | Upto 50 kgs load |
| 24 | Extra for every additional 50kgs load (Note: Fraction >=25kgs shall be taken as equivalent to next load of 50kgs) |
| 25 | Extra for uphill terrain (Ground Slope >= 07 deg) |
| 26 | Hiring of mobile crane |
| 27 | Hiring of excavator 3D (with driver & fuel) for earthwork excavation. |
| 28 | MOTORS |
| 29 | Disconnecting of all motor leads, dismantling of motor, draining off the m.oil (if applicable) and collection in suitable pan, taking out the rotor from the stator, and complete disassembly as per requirement of job: |
| 30 | upto 10 HP |
| 31 | upto 60 HP |
| 32 | >60 upto 200 HP |
| 33 | >200 HP upto 350 HP |
| 34 | greater than 350 HP |
| 35 | >500HP (HV motors) |
| 36 | Assembling of all motor parts, refilling of drained out m.oil (if applicable), coupling and alignment with pump, reconnecting of leads and testing on full load. |
| 37 | upto 10 HP |
| 38 | upto 60 HP |
| 39 | >60 upto 200 HP |
| 40 | >200 HP upto 350 HP |
| 41 | greater than 350 HP |
| 42 | >500HP (HV motors) |
| 43 | Replacement of Non Reverse Ratchet on Driving End (DE) of Vertical electric motor by way of:Disconnecting all leads from motor and marking the terminals, uncoupling and dismounting of motor from the motor stool. Removal of non reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting after necessary repairs/ replacements. Refitting of motor, coupling and alignment with the pump. The job includes testing of motor on load. |
| 44 | Replacement of Non Reverse Ratchet on Non Driving End (NDE) of Vertical electric motor by way of:Isolating the motor, dismantling of top end cover of the motor, removing of non reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting back of parts after necessary repairs/ replacements and testing of motor on load. |
| 45 | Replacement of Driving End (DE) bearing of Vertical electric motor by way of:Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump, dismounting of motor from the motor stool. Opening the bottom end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. |
| 46 | upto 60 HP rating |
| 47 | >60 upto 200 HP |
| 48 | >200 HP upto 350 HP |
| 49 | greater than 350 HP |
| 50 | >500HP (HV motors) |
| 51 | Replacement of Non Driving End (NDE) bearing of Vertical electric motor by way of:Disconnecting all leads from motor and marking of terminals, dismantling of top end cover of the motor & removal of non-reverse ratchet assembly. Draining off the m.oil and collection in a suitable pan (if applicable), extraction of old damaged bearing from the motor, fitting of new NDE bearing and refilling of old m.oil. The job includes load testing of motor. |
| 52 | upto 60 HP rating |
| 53 | >60 upto 200 HP |
| 54 | >200 HP upto 350 HP |
| 55 | greater than 350 HP |
| 56 | >500HP (HV motors) |
| 57 | Replacement of Driving End (DE) bearing of horizontal electric motor by way of:Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. |
| 58 | upto 60 HP rating |
| 59 | >60 upto 200 HP |
| 60 | >200 HP upto 350 HP |
| 61 | greater than 350 HP |
| 62 | >500HP (HV motors) |
| 63 | Replacement of Non-Driving End (NDE) bearing of horizontal electric motor by way of:Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of NDE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. |
| 64 | upto 60 HP rating |
| 65 | >60 upto 200 HP |
| 66 | >200 HP upto 350 HP |
| 67 | greater than 350 HP |
| 68 | >500HP (HV motors) |
| 69 | VOLTAGE STABILIZERS |
| 70 | Dismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling. |
| 71 | upto 50 kVA |
| 72 | >50 upto 100kVA |
| 73 | >100kVA upto 250 kVA |
| 74 | greater than 250 kVA |
| 75 | Assembling of all parts of 3-ph Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. Oil |
| 76 | upto 50 kVA |
| 77 | >50 upto 100kVA |
| 78 | >100kVA upto 250 kVA |
| 79 | greater than 250 kVA |
| 80 | AUTOTRANSFORMER STARTER |
| 81 | Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. |
| 82 | upto 60 HP rating |
| 83 | >60 upto 200 HP |
| 84 | >200 HP upto 350 HP |
| 85 | greater than 350 HP |
| 86 | Fitting of autotransformer coil assembly in the starter oil tank, refilling of collected t.oil in the tank, reconnecting all leads and load testing of the starter. |
| 87 | upto 60 HP rating |
| 88 | >60 upto 200 HP |
| 89 | >200 HP upto 350 HP |
| 90 | greater than 350 HP |
| 91 | POLES |
| 92 | Dismantling of pole/ street light standard/ strut embedded incement concrete foundation etc. as required. |
| 93 | Erection of metallic pole in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. |
| 94 | Above 4.5 meter and upto 6.5 meter |
| 95 | Above 6.5 meter and upto 8.0 meter |
| 96 | Above 8.0 meter and upto 10.0 meter |
| 97 | Above 10.00 meter and upto 12.00 meter |
| 98 | Supply of new bearing as under: (Make: SKF imported/ equivalent imported) |
| 99 | Bearing No. 3210 A/C3 |
| 100 | Bearing No.3212 A/C3 |
| 101 | Bearing No.3213 A/C3 |
| 102 | Bearing No.3309 A/C3 |
| 103 | Bearing No.3313 A/C3 |
| 104 | Bearing No.51310 |
| 105 | Bearing No.51312 |
| 106 | Bearing No.51314 |
| 107 | Bearing No.51320 |
| 108 | Bearing No.6014 |
| 109 | Bearing No.6220 |
| 110 | Bearing No.6314-Z |
| 111 | Bearing No.6315-Z |
| 112 | Bearing No.6320 |
| 113 | Bearing No.6324 |
| 114 | Bearing No.6406 |
| 115 | Bearing No.6408 |
| 116 | Bearing No.6410 |
| 117 | Bearing No.6411 |
| 118 | Bearing No.6412 |
| 119 | Bearing No.6415 |
| 120 | Bearing No.6418 |
| 121 | Bearing No.NU322 ECJ |
| 122 | Bearing No.NU324 ECJ |
| 123 | Bearing No.29322 E |
| 124 | Bearing No.29324 E |
| 125 | Bearing No.29328 E |
| 126 | Bearing No.29330 E |
| 127 | Bearing No.29424 E |
| 128 | Bearing No.29426 E |
| 129 | Bearing No.7316-B |
| 130 | Bearing No.6409 |
| 131 | Bearing No.NU 312 |
| 132 | Bearing No.6015 |
| 133 | Bearing No.6020 |
| 134 | Bearing No.6214 |
| 135 | Bearing No.NU 206 EC |
| 136 | Bearing No.6212 |
| 137 | Supply of new bearing as under: (NBC/ ARB/ ZKL/ equivalent domestic) |
| 138 | Bearing No.1217 |
| 139 | Bearing No.16026 |
| 140 | Bearing No.3200 |
| 141 | Bearing No.3210 |
| 142 | Bearing No.3212 |
| 143 | Bearing No.3213 |
| 144 | Bearing No.3214 |
| 145 | Bearing No.3215 |
| 146 | Bearing No.3306 |
| 147 | Bearing No.3307 |
| 148 | Bearing No.3309 |
| 149 | Bearing No.3310 |
| 150 | Bearing No.3311 |
| 151 | Bearing No.3312 |
| 152 | Bearing No.3313 |
| 153 | Bearing No.51310 |
| 154 | Bearing No.51312 |
| 155 | Bearing No.51314 |
| 156 | Bearing No.51320 |
| 157 | Bearing No.51322 |
| 158 | Bearing No.6014 |
| 159 | Bearing No.6028 |
| 160 | Bearing No.6217 |
| 161 | Bearing No.6220 |
| 162 | Bearing No.6305 |
| 163 | Bearing No.6306 |
| 164 | Bearing No.6307 |
| 165 | Bearing No.6308 |
| 166 | Bearing No.6309 |
| 167 | Bearing No.6310 |
| 168 | Bearing No.6311 |
| 169 | Bearing No.6312 |
| 170 | Bearing No.6313 |
| 171 | Bearing No.6314 |
| 172 | Bearing No.6315 |
| 173 | Bearing No.6317 |
| 174 | Bearing No.6320 |
| 175 | Bearing No.6322 |
| 176 | Bearing No.6406 |
| 177 | Bearing No.6408 |
| 178 | Bearing No.6410 |
| 179 | Bearing No.6411 |
| 180 | Bearing No.6412 |
| 181 | Bearing No.6415 |
| 182 | Bearing No.7214 |
| 183 | Bearing No.7220 |
| 184 | Bearing No.7308 |
| 185 | Bearing No.7312 |
| 186 | Bearing No.7314 |
| 187 | Bearing No.7319 |
| 188 | Rebuilding of bearing seats and then machining to the required size for proper fitment of bearings. |
| 189 | Providing of transformer oil / Type II inhibited oil conforming to IS 335 (Preferred make: Power oil/ Indian Oil Servo/ HPCL) |
| 190 | Filtration & demoisturizing of Transformer-oil (on site) |
| 191 | Complete rewinding of stator coils of 3-phase LV horizontal/ vertical induction motor after complete removal of burnt out winding, cleaning of slots, etc. by way of the following: (Note: The unserviceable scrap copper generated is not taken into account for estimation of rates and shall be credited separately). |
| 192 | Providing, preparation and fitting new copper coils of electrolytic grade copper wire windings having F-class insulation in place of damaged coils including allied jobs such as varnishing (Becks or any other reputed make) drying, etc., - per kg of winding.(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 193 | Providing, preparation and fitting new copper coils of electrolytic grade copper strip windings having F-class insulation in place of damaged windings including allied costs such as varnish (Becks or any other reputed make), drying, etc., - per kg of winding. (Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 194 | Rewinding of old LV Copper Coil and re-insulation with new inter-layer insulation (Labour only).(Note: Labour charges for fitting of inter-layer insulation are taken into account for estimation but the cost of inter-layer insulation materials is not included and shall be paid extra) |
| 195 | Varnishing, impregnation and drying of stator windings of LT motors with standard quality varnish (Becks or any other reputed make) as specified below along with proper tapings, etc. as per requirement. |
| 196 | upto 5HP |
| 197 | > 5 HP upto 20 HP |
| 198 | > 20 HP upto 50 HP |
| 199 | > 50 HP upto 100 HP |
| 200 | > 100 HP upto 200 HP |
| 201 | > 200 HP upto 350 HP |
| 202 | > 350 HP |
| 203 | Providing and replacement of copper contact points on Voltage stabilizer regulator plate |
| 204 | Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) |
| 205 | ELECTROMAGNETIC BRAKES |
| 206 | Providing and fitting of AC solenoid for electromagnetic brake of stroke length as under: (Make: BCH or equivalent) |
| 207 | 31.4mm |
| 208 | Providing and fitting of AC solenoid brake having wheel diameter as under: |
| 209 | 4 inch |
| 210 | 5.5 inch |
| 211 | 7 inch |
| 212 | 10 inch |
| 213 | Providing and fitting of drum for AC solenoid brake having wheel diameter as under: |
| 214 | 4 inch |
| 215 | 5.5 inch |
| 216 | 7 inch |
| 217 | 10 inch |
| 218 | Providing and fitting of brake lining for AC solenoid brake having nominal wheel diameter as under: |
| 219 | 4 inch |
| 220 | 5.5 inch |
| 221 | 7 inch |
| 222 | 10 inch |
| 223 | Providing and fitting of brake shoe assembly for AC solenoid brake having nominal wheel diameter as under: |
| 224 | 4 inch |
| 225 | 5.5 inch |
| 226 | 7 inch |
| 227 | 10 inch |
| 228 | Providing and fitting of brake coil for AC solenoid brake having nominal wheel diameter as under: |
| 229 | 4 inch |
| 230 | 5.5 inch |
| 231 | 7 inch |
| 232 | 10 inch |
| 233 | SLIP RING MOTORS |
| 234 | Providing and replacement of carbon brush for slip ring motors as under |
| 235 | 65mm x 50mm x 25mm (Grade: M16E) |
| 236 | 40 x 40 x 20mm Grade: M14E |
| 237 | 50 x 50 x 25mm Grade: M14E |
| 238 | 32 x 20 x 16mm Grade: M15E |
| 239 | 38 x 20 x 10mm Grade: M15E |
| 240 | 38 x 25 x 10mm Grade: M15E |
| 241 | 50 x 38 x 25mm Grade: M15E |
| 242 | 50 x 38 x 32mm Grade: M15E |
| 243 | 60 x 40 x 32mm Grade: M15E |
| 244 | 40 x 40 x 20mm Grade: M16E |
| 245 | 65 x 50 x 25mm Grade: M145E |
| 246 | 50 x 50 x 25mm Grade: BE22Z1 |
| 247 | Providing and replacement of brass brush holder of HV slip ring motor with pocket sizes as under: |
| 248 | BHEL 11KV HT motor pocket size 50mm/25mm |
| 249 | BHEL 11KV HT motor pocket size 38mm/25mm |
| 250 | INSULATION MATERIALS |
| 251 | Providing of inter-layer Insulating materials for rewinding of motors, transformers, etc. as per requirement |
| 252 | Grade 3.1 Pre-compressed presspahn paper board (like Raman Sigmacom 3.1 or other make) for use as phase separator/ spacer/ axial ducts/ cylinder for core yoke insulation |
| 253 | Grade K pre-compressed Press Board of required thickness (like Senapathy or any other make) |
| 254 | Inter-leaved insulating paper between the layers of the winding Epoxy dotted Kraft Paper |
| 255 | Fiberglass cotton insulation tape 1-inch |
| 256 | Epoxy slot wedges |
| 257 | F-class fiberglass insulating sleeves (for stubbing, etc.) |
| 258 | Upto 6mm |
| 259 | 8mm to 12mm |
| 260 | CONTACTORS |
| 261 | Providing and fitting of 3-pole contactor with specified coil voltage: |
| 262 | L&T ML 1.5 |
| 263 | L&T ML 2 |
| 264 | L&T ML 3 |
| 265 | L&T ML 4 |
| 266 | L&T ML 6 |
| 267 | L&T ML 12 |
| 268 | L&T MNX 50 |
| 269 | L&T MNX 70 |
| 270 | L&T MNX 80 |
| 271 | L&T MNX 95 |
| 272 | L&T MNX 110 |
| 273 | L&T MNX 140 |
| 274 | L&T MNX 185 |
| 275 | L&T MNX 225 |
| 276 | L&T MNX 250 |
| 277 | L&T MNX 300 |
| 278 | L&T MNX 400 |
| 279 | L&T MNX 550 |
| 280 | L&T MNX 650 |
| 281 | MK1 (220V-440V) |
| 282 | MK2 (360 V-440V) |
| 283 | LC1F Replaced with LC1G Series |
| 284 | Schneider Electric LC1G115 |
| 285 | Schneider Electric LC1G150 |
| 286 | Schneider Electric LC1G185 |
| 287 | Schneider Electric LC1G225 |
| 288 | Schneider Electric LC1G265 |
| 289 | Schneider Electric LC1G330 |
| 290 | Schneider Electric LC1G400 |
| 291 | Schneider Electric LC1G630 |
| 292 | AC COIL |
| 293 | Providing and fitting of new AC coil with specified coil voltage for contactors: |
| 294 | L&T ML2/ ML3/ |
| 295 | L&T ML4/ ML6 |
| 296 | L&T ML 10/ 12 |
| 297 | L&T MNX 50/ 70/ 80 |
| 298 | L&T MNX 95/ 110/ 140 |
| 299 | L&T MNX 185/ 225/ 250 |
| 300 | L&T MNX 300/ 400 |
| 301 | L&T MNX 550/ 650 |
| 302 | CONTACT KIT |
| 303 | Providing and fitting of new Contact kit set for contactors |
| 304 | L&T MNX 9 TO MNX 40 |
| 305 | L&T MNX 50 TO MNX 80 |
| 306 | L&T MNX 95 TO MNX 140 |
| 307 | L&T MNX 185 TO MNX 250 |
| 308 | L&T MNX 300 TO MNX 400 |
| 309 | L&T MNX 3550 TO MNX 650 |
| 310 | L&T ML 2 |
| 311 | L&T ML 3 |
| 312 | L&T ML 4 |
| 313 | L&T ML 6 |
| 314 | L&T ML 10 |
| 315 | L&T ML 12 |
| 316 | ELECTROPNEUMATIC TIMING RELAYS |
| 317 | Providing, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make) |
| 318 | Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH make or equivalent) . |
| 319 | (2NO + 2NC) double block; ON delay |
| 320 | (2NO + 2NC) double block; ON & OFF delay |
| 321 | Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent) . |
| 322 | (1NO + 1NC) contact block Timed |
| 323 | (2NO + 2NC) contact block |
| 324 | Magnetic coil 415V AC |
| 325 | Magnet frame assembly without coil |
| 326 | Knob Assembly |
| 327 | ELECTRONIC TIMER Relay |
| 328 | Providing, fitting and setting of DIN mounted electronic Timer (BCH or equivalent make) |
| 329 | Delay on make type BAR 0.1 Sec. - 10 Hrs |
| 330 | Delay on break type BCR 0.1 Sec. - 10 Hrs. |
| 331 | Recycling type BDR 0.1 Sec. - 10 Hrs |
| 332 | Multifunction type BLR 0.1 Sec. - 10 Hrs |
| 333 | Star-Delta Timer 17.5 mm width 0-60 Sec 240-415V AC |
| 334 | Electronic Timer-BTR17 Series - 17.5mm width |
| 335 | ON delay Timer 240V AC/24V AC/DC (0.3 Sec to 30 Hr) |
| 336 | OFF delay Timer 240V AC/24V AC/DC (0.3 Sec to 30 Hr) |
| 337 | Cyclic timer 12-240V AC/DC (0.1 Sec to 100 Hr) |
| 338 | Multi-function timer 12-240V AC/DC, 12 Function (0.1 Sec to 100 Hr) |
| 339 | Electronic Timer-BTR22 Series - 22.5 mm width |
| 340 | ON delay Timer 24 - 240V AC/DC 2 C/O Contact (0.1 sec to 100Hr) |
| 341 | OFF delay Timer 24 - 240V AC/DC 2 C/O Contact (0.1 sec to 100Hr) |
| 342 | Cyclic Timer 24 - 240V AC/DC 2 C/O Contact (0.1 Sec to 100 Hr) |
| 343 | Multifunction Timer 24 - 240V AC/DC,2 C/O Contact (0.1 Sec to 100 Hr) |
| 344 | Providing, fitting and setting of DIN mounted electronic Timer (L&T GIC or equivalent make) |
| 345 | Star Delta (range from 3s - 30s) 240V AC |
| 346 | Star Delta (range from 12s - 120s) 240 - 415V AC |
| 347 | ON delay (0.3s - 30hrs) 240V AC |
| 348 | Providing and fitting of bakelite connection plate min. 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots. |
| 349 | Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. |
| 350 | Complete replacement of suitable copper control wiring of ATS including connections, tapping and insulation as per requirement. |
| 351 | L&T MU-G SUBMERSIBLE PUMP CONTROLLER SPARES |
| 352 | Electronic Star-Delta Timer 3-30s and 12-120 sec (L&T ST100) |
| 353 | Providing and fitting of Terminal Block |
| 354 | 60A - 3 way |
| 355 | 100A - 3 way |
| 356 | VOLT/AMMETER |
| 357 | Volt-Ammeter 500V, |
| 358 | Ampere Meter (0-1 to 0-50 A / 0-60 to 0-100 A) (Round Projection) |
| 359 | Ampere Meter (0-1 to 0-50 A / 0-60 to 0-100 A) (Square Flush) |
| 360 | Volt Meter (0-1 to 0-60 V / 0-75 to 0-300 A/ 0-500 to 0-600 A) (Round Projection) |
| 361 | Ampere Meter (0-1 to 0-60 V / 0-75 to 0-300 A/ 0-500 to 0-600 A) (Square Flush) |
| 362 | SINGLE PHASE PREVENTER |
| 363 | Providing, fitting and setting of single phase preventer relay of specified relay range (Make: L&t/Bentex or Equivalent) |
| 364 | Single phase preventing relay Sz5 type |
| 365 | Single phase preventing relay SDz5 type |
| 366 | Safe ON 06 Wire DOL |
| 367 | Safe ON 07 Wire Star Delta |
| 368 | THERMAL OVERLOAD RELAY |
| 369 | Providing, fitting and setting of thermal overload relay of specified relay range (Make: L&T MU) |
| 370 | MN2 Relay (Directly Operated)(Directly Mounting on MNX 09-40 with folloiwng Ranges |
| 371 | 0.2 to 1 (all range) A |
| 372 | 0.9 to 10 (all range) A |
| 373 | 14 to 23 A |
| 374 | 20-33 A |
| 375 | 24-40 A |
| 376 | MN5 Relay (Directly Operated)(Directly Mounting on MNX 50-80 with folloiwng Ranges |
| 377 | 9 to 33 A (all range) |
| 378 | 30 -50 A |
| 379 | 36-60 A |
| 380 | 45-75 A |
| 381 | 66-110 A |
| 382 | MN12 Relay (CT Operated)(sEPARATE Mounting) with folloiwng Ranges |
| 383 | 28 to 150 A (all range) |
| 384 | 135-225 A |
| 385 | 180-300 A |
| 386 | 270-450 A |
| 387 | ML1 (all ranges) |
| 388 | ML2/ML3 (all ranges) |
| 389 | MU1 (all ranges) |
| 390 | MU2 relays of following ranges |
| 391 | 9 - 14A |
| 392 | 13 - 21A |
| 393 | 15 - 25A |
| 394 | 20 - 32A |
| 395 | 24 - 38A |
| 396 | 28 - 42A |
| 397 | STANDARD OPERAING COIL |
| 398 | Providing and fitting of standard operating coil for following contactors |
| 399 | MK1/ MK2 |
| 400 | CONTACT BRIDGE |
| 401 | Providing and fitting of contact bridge without contact of following contactors |
| 402 | MK1/ MK2 |
| 403 | MU1/ MU2/ MU3 |
| 404 | OIL IMMERSED MANUAL/ SEMI-AUTOMATIC/ FULLY-AUTOMATIC STARTER SPARES |
| 405 | Providing and replacement of operating coil for oil immersed semi-automatic starter, upto 40HP |
| 406 | Providing and fitting of heavy duty contact kit set for semi-automatic/ fully automatic SD oil immersed starters (set of 03 moving and 06 stationary contacts) |
| 407 | Upto 40 HP |
| 408 | Spares for oil immersed manual starters |
| 409 | Fixed finger contact |
| 410 | Moving tip contact |
| 411 | No volt coil |
| 412 | Moving drum contact (starters upto 40HP) |
| 413 | Moving drum contact (starters > 40HP) |
| 414 | Base plate Bakelite/ DMC (starters upto 40HP) |
| 415 | Base plate Bakelite/ DMC (starters > 40HP) |
| 416 | Steam carrier assembly (starters upto 40HP) |
| 417 | Steam carrier assembly (starters > 40HP) |
| 418 | Sequence shaft (starters upto 40HP) |
| 419 | Sequence shaft (starters > 40HP) |
| 420 | Bakelite tube for Sequence shaft (starters upto 40HP) |
| 421 | Bakelite tube for Sequence shaft (starters > 40HP) |
| 422 | Trip rod assembly (starters upto 40HP) |
| 423 | Trip rod assembly (starters > 40HP) |
| 424 | Lock lever |
| 425 | Cam assembly |
| 426 | Oil dashpot assembly |
| 427 | Overload coil (set of 03 nos.) upto 20HP |
| 428 | Overload coil (set of 03 nos.) 30- 40HP |
| 429 | Overload coil (set of 03 nos.) 50- 60HP |
| 430 | Overload coil (set of 03 nos.) 70- 80HP |
| 431 | Overload coil (set of 03 nos.) 90- 100HP |
| 432 | Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 36kA breaking capacity (Ics= 100% Icu) (Make: L&T d-sine or equivalent) having max. of thermal release range as under: |
| 433 | upto and including 100A (Ics= 50% Icu) |
| 434 | 160A (Thermal Release range (from 11 A upto 80 A)) |
| 435 | 160A (Thermal Release range (84 A-125 A)) |
| 436 | A (Thermal Release range (108-160 A)) |
| 437 | 250 A (Thermal Release range from 108 A upto 160 A |
| 438 | 250 A (Thermal Release range from 134 A upto 200 A |
| 439 | 250 A (Thermal Release range from 168 A upto 250 A |
| 440 | 400 A (Thermal Release range from 134 A upto 200A |
| 441 | 400 A (Thermal Release range from 168 A upto 250A |
| 442 | 400 A (Thermal Release range from 215 A upto 400A |
| 443 | 800 A (Thermal Release range from 335 A upto 630A |
| 444 | 600 A (Thermal Release range from 536 A upto 800A |
| 445 | Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 50kA breaking capacity Ics = 100% Icu (Make: L&T d-sine or similar) Having max. of thermal release range as under: |
| 446 | 160A (Thermal Release range (from 11 A upto 50 A)) |
| 447 | 160A (Thermal Release range (43-100 A)) |
| 448 | 160A (Thermal Release range (84-125A)) |
| 449 | 160A (Thermal Release range (108-160A)) |
| 450 | 250A (Thermal Release range (108-160A)) |
| 451 | 250 A (Thermal Release range (134-200A)) |
| 452 | 250A (Thermal Release range (168-250A)) |
| 453 | 400A (Thermal Release range (134-200A)) |
| 454 | 400A (Thermal Release range (168-400A)) |
| 455 | 800A (Thermal Release range (335-630A)) |
| 456 | SPREADER TERMINAL |
| 457 | Providing of set of spreader terminals for above 3-pole MCCBs |
| 458 | Providing and fitting of Shunt release for ACB (L&T C-power) |
| 459 | Providing and fitting of Under Voltage Release for ACB (L&T C-power) |
| 460 | Providing and fitting of Earth Fault Release for ACB (L&T C-power) |
| 461 | Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under: |
| 462 | upto 400 - 1250A |
| 463 | 1600 - 2000A |
| 464 | Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C-power ACB |
| 465 | Providing and fitting of CT for DN1 type L&T C-power ACB |
| 466 | 800/ 1000A |
| 467 | 1250/ 1600A |
| 468 | 2000A |
| 469 | CHANGE OVER |
| 470 | Providing and fitting of Change over four pole Knife type ( L&T / Bentex/ reputed make |
| 471 | COS 100 |
| 472 | COS 200 |
| 473 | COS 300 |
| 474 | COS 400 |
| 475 | COS 600 |
| 476 | SPARES FOR ACB (L&T C-POWER) |
| 477 | Providing and fitting of pole assembly for draw out type ACB (L&T C-power) |
| 478 | upto 1250A |
| 479 | 2000A |
| 480 | Providing and fitting of Arc Chute (440V) for ACB (L&T C-power) |
| 481 | upto 1250A |
| 482 | 1600 - 2000A |
| 483 | Providing and fitting of Jaw contact for ACB (L&T C-power) |
| 484 | 630-1000A |
| 485 | 1250/ |
| 486 | 1600A/ 2000A |
| 487 | Providing and fitting of Fixed arcing contact for ACB (L&T C-power) |
| 488 | 800- 1600A |
| 489 | 2000A |
| 490 | Providing and fitting of Moving arcing contact for ACB (L&T C-power) |
| 491 | 800- 2000A |
| 492 | INSTRUMENTATION AND PANEL ACCESSORIES |
| 493 | Providing and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Rishabh/ AE) |
| 494 | Providing and fitting of flush type analog Voltmeter moving iron AC meter as under:(Make: Rishabh/ AE/ C&S/ BCH/ L&T) |
| 495 | 48x48mm 6 V up to 300 V |
| 496 | 72x72mm 6 V up to 300 V |
| 497 | 96x96mm 6 V up to 300 V |
| 498 | 144x144mm 6 V up to 300 V |
| 499 | 48x48mm 400 V, 500V, 600 V, 750V |
| 500 | 72x72mm 400 V, 500V, 600 V, 750V |
| 501 | 96x96mm 400 V, 500V, 600 V, 750V |
| 502 | 144x144mm 400 V, 500V, 600 V, 750V |
| 503 | Providing and fitting of flush type analog Ammeter moving iron AC meter as under:(Make: Rishabh/ AE/ C&S/ BCH/ L&T) |
| 504 | 48x48mm 30 A up to 100 A |
| 505 | 72x72mm 30 A up to 100 A |
| 506 | 96x96mm 30 A up to 100 A |
| 507 | 144x144mm 30 A up to 100 A |
| 508 | 48x48mm above 100 A Range |
| 509 | 72x72mm above 100 A Range |
| 510 | 96x96mm above 100 A Range |
| 511 | 144x144mm above 100 A Range |
| 512 | Providing and fitting of flush type frequency meter with range 45-55Hz:(Make: Rishabh/ AE/ C&S/ BCH) |
| 513 | Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) |
| 514 | Providing and fitting of 10A voltmeter selector switch with OFF(Make: L&T/ Rishabh/ AE/ Teknic) |
| 515 | Providing and fitting of tape insulated ring type metering current transformers (Rishabh/ AE/ Crompton/ Kilburn) as under: |
| 516 | 100/5A or 150/5A - Class 1 - Burden 5VA |
| 517 | 200/5A - Class 1 - Burden 10VA |
| 518 | 400/5A - Class 1 - Burden 15VA |
| 519 | 600/5A - Class 1 - Burden 15VA |
| 520 | 800/5A - Class 1 - Burden 15VA |
| 521 | 1000/5A - Class 1 - Burden 15VA |
| 522 | 2000/5A - Class 1 - Burden 15VA |
| 523 | Extra for 1A secondary upto 600/1A over corresponding rate |
| 524 | Providing and fitting of analog VAC hour meter(Make: L&T or equivalent make) |
| 525 | DIN mounting |
| 526 | Flush mounting |
| 527 | Providing and fitting of flush or projecting head push button actuator with contact block (L&T/ Teknic/ ABB/ BCH or any other reputed make) |
| 528 | Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH or any other reputed make) |
| 529 | Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) |
| 530 | Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) |
| 531 | 50V or less unbalance & 1 C/O DIN mounted |
| 532 | 50V or less unbalance & 1 C/O Panel wall mounted |
| 533 | 70V or less unbalance & 2 C/O DIN mounted |
| 534 | Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) |
| 535 | Providing of HRC fuses (2A - 32A) ratings |
| 536 | Providing and fitting of Fuse holders for fuses upto 32A rating |
| 537 | Providing and fixing uPVC panel trunking with cover |
| 538 | 15x15mm |
| 539 | 25x25mm |
| 540 | VCB PANEL ACCESSORIES |
| 541 | Providing and fitting of 96x96 flush mounting 3-phase LED Multifunction Meter of Class 1 accuracy (Make: L&T/Schneider) |
| 542 | Providing and fitting of LED Energy Meter of Class 1 accuracy with RS 485 port facility (Make: Schneider EM1200) |
| 543 | Replacement of Trip Circuit Supervision Relay |
| 544 | Alstom VAX31 ZGAT74BCH 110V DC |
| 545 | Replacement of Master Trip Relay |
| 546 | Alstom VAJH13 YF0752 110V DC |
| 547 | Providing and replacement of 3-phase Over Current & Earth Fault Relay |
| 548 | Make: L&T Model: MC31AnX |
| 549 | Make : L&T Model: MC61CnX (with high set and RS-485 port) |
| 550 | Schneider MiCOM P111 |
| 551 | Ashida ADR141A |
| 552 | Providing and replacement of motor protection relay |
| 553 | Schneider Electric MiCOM P220 |
| 554 | Providing and replacement of static under and over voltage relay (C&S BU1-AC-UO) |
| 555 | Replacement of Alarm annunicator of below mentioned specifications |
| 556 | 12-window (Proton Power Control/ equivalent) Op. Voltage : 110-125 V DC |
| 557 | Replacement of 4 inch nominal size electronic panel hooter (multivoltage). |
| 558 | Providing and replacement of multichannel temperature Scanner as under: |
| 559 | 16-channel input & 8 channel relay output (Masibus 85xx+) |
| 560 | Providing and fitting of 25A standard mounting type Breaker Control Switch (TNC) with 01 Trip + 01 Close |
| 561 | 100W nominal output load Power Pack with Battery backup (ALAN India/ equivalent) |
| 562 | Providing and replacement of 1000uF 450VDC capacitor |
| 563 | Providing and replacement of anti pumping relay |
| 564 | MISCELLANEOUS |
| 565 | Providing of CRC2-26 power spray for electrical preventive maintenance contact cleaning, etc. |
| 566 | Providing of WD-40 multipurpose spray for electrical preventive maintenance rust cleaning, etc. |
| 567 | Providing of spray paint, quick drying, for marking on metal surfaces. |
| 568 | Providing and fitting of Polyamide 6.6 DIN rail mounted feed through terminal connector only of following wire size capacities |
| 569 | 2.5 sq.mm |
| 570 | 4.0 sq.mm |
| 571 | 6.0 sq.mm |
| 572 | 10.0 sq.mm |
| 573 | 16 sq.mm |
| 574 | 25 sq.mm |
| 575 | Providing and fitting of Polyamide 6.6 DIN rail mounted feed through terminal complete with connector, end plate, shorting link & marker of following wire size capacities |
| 576 | 2.5 sq.mm |
| 577 | 4.0 sq.mm |
| 578 | 6.0 sq.mm |
| 579 | 10.0 sq.mm |
| 580 | 16 sq.mm |
| 581 | 25 sq.mm |
| 582 | Providing and fitting of Polyamide 6.6 DIN rail mounted Multiple Output Terminal complete with connector, end plate, shorting link & marker of following wire size capacities |
| 583 | 4.0 sq.mm 32A |
| 584 | Providing and fitting of Polyamide 6.6 DIN rail mounted earth terminal with marker of following wire size capacities |
| 585 | 4.0 sq.mm |
| 586 | 6.0 sq.mm |
| 587 | 10.0 sq.mm |
| 588 | 16 sq.mm |
| 589 | Providing and fitting of Polyamide 6.6 DIN rail mounted distribution block with marker of following wire size capacities |
| 590 | 3 block |
| 591 | 4 block |
| 592 | 8 block |
| 593 | 12 block |
| 594 | TERMINALS/ LUGS |
| 595 | Providing and crimping of various Aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: |
| 596 | 25 sq. mm |
| 597 | 35 sq. mm |
| 598 | 50 sq. mm |
| 599 | 70 sq. mm |
| 600 | 95 sq. mm |
| 601 | 120 sq. mm |
| 602 | 150 sq. mm |
| 603 | 185 sq. mm |
| 604 | 240 sq. mm |
| 605 | 300 sq. mm |
| 606 | 400 sq. mm |
| 607 | 500 sq. mm |
| 608 | 630 sq. mm |
| 609 | Providing and crimping of various copper lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under: |
| 610 | 25 sq. mm |
| 611 | 35 sq. mm |
| 612 | 50 sq. mm |
| 613 | 70 sq. mm |
| 614 | 95 sq. mm |
| 615 | 120 sq. mm |
| 616 | 150 sq. mm |
| 617 | 185 sq. mm |
| 618 | 240 sq. mm |
| 619 | 300 sq. mm |
| 620 | 400 sq. mm |
| 621 | 500 sq. mm |
| 622 | 630 sq. mm |
| 623 | CABLES |
| 624 | Providing and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors as under (Makes: Finolex/ L&T/ Havells/ KEI/ Polycab/ equivalent) |
| 625 | 1.5 sqmm |
| 626 | 2.5 sqmm |
| 627 | 4.0 sqmm |
| 628 | 6.0 sqmm |
| 629 | 10.0 sqmm |
| 630 | 16.0 sqmm |
| 631 | 25.0 sqmm |
| 632 | 35.0 sqmm |
| 633 | Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable conforming to IS 7098 as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
| 634 | 16 sqmm |
| 635 | 25 sqmm |
| 636 | 35 sqmm |
| 637 | 50 sqmm |
| 638 | 70 sqmm |
| 639 | 95 sqmm |
| 640 | 120 sqmm |
| 641 | 150 sqmm |
| 642 | 185 sqmm |
| 643 | 240 sqmm |
| 644 | 300 sqmm |
| 645 | 400 sqmm |
| 646 | 500 sqmm |
| 647 | 630 sqmm |
| 648 | Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
| 649 | 16 sqmm |
| 650 | 25 sqmm |
| 651 | 35 sqmm |
| 652 | 50 sqmm |
| 653 | 70 sqmm |
| 654 | 95 sqmm |
| 655 | 120 sqmm |
| 656 | 150 sqmm |
| 657 | 185 sqmm |
| 658 | 240 sqmm |
| 659 | 300 sqmm |
| 660 | 400 sqmm |
| 661 | 500 sqmm |
| 662 | 630 sqmm |
| 663 | Providing and fitting of XLPE insulated, 1100V single core industrial unarmoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
| 664 | 16 sqmm |
| 665 | 25 sqmm |
| 666 | 35 sqmm |
| 667 | 50 sqmm |
| 668 | 70 sqmm |
| 669 | 95 sqmm |
| 670 | 120 sqmm |
| 671 | 150 sqmm |
| 672 | 185 sqmm |
| 673 | 240 sqmm |
| 674 | 300 sqmm |
| 675 | 400 sqmm |
| 676 | 500 sqmm |
| 677 | 630 sqmm |
| 678 | Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
| 679 | 25 sqmm |
| 680 | 35 sqmm |
| 681 | 50 sqmm |
| 682 | 70 sqmm |
| 683 | 95 sqmm |
| 684 | 120 sqmm |
| 685 | 150 sqmm |
| 686 | 185 sqmm |
| 687 | 240 sqmm |
| 688 | 300 sqmm |
| 689 | 400 sqmm |
| 690 | 500 sqmm |
| 691 | 630 sqmm |
| 692 | CONTROL CABLES |
| 693 | Providing and fitting of XLPE insulated, 1100V grade industrial armoured Copper control cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab) |
| 694 | 6C x 1.5 sq. mm |
| 695 | 8C x 1.5 sq. mm |
| 696 | 10C x 1.5 sq. mm |
| 697 | 12C x 1.5 sq. mm |
| 698 | 2C x 2.5 sq. mm |
| 699 | 4C x 2.5 sq. mm |
| 700 | 6C x 2.5 sq. mm |
| 701 | 8C x 2.5 sq. mm |
| 702 | 12C x 2.5 sq. mm |
| 703 | CABLE KITS |
| 704 | Providing and fitting of Heat Shrinkable termination kit for 11 kV(E) XLPE Cable (outdoor type) |
| 705 | 3C x 70 - 95 - 120 sq.mm |
| 706 | 3C x 150 - 185 sq.mm |
| 707 | 3C x 240 - 300 - 400 sq.mm |
| 708 | 1C x 35 - 50 sq.mm |
| 709 | 1C x 70 - 95 - 120 sq.mm |
| 710 | 1C x 150 - 185 - 240 -300 sq.mm |
| 711 | 1C x 400 - 500 - 630 sq.mm |
| 712 | Providing and fitting of Heat Shrinkable termination kit for 11 kV (E) XLPE Cable (Indoor type) |
| 713 | 3C x 70 - 95 - 120 sq.mm |
| 714 | 3C x 150 - 185 sq.mm |
| 715 | 3C x 240 - 300 - 400 sq.mm |
| 716 | Providing and fitting of Heat Shrinkable termination kit for 33 kV(E) XLPE Cable (outdoor type) |
| 717 | 3C x 35 - 50 sq.mm |
| 718 | 3C x 70 - 95 sq.mm |
| 719 | 3C x 120 - 150 - 185 sq.mm |
| 720 | 3C x 240 - 300 - 400 sq.mm |
| 721 | Providing and fitting of Heat Shrinkable termination kit for 3.5/4C LT 1.1 kv Cable |
| 722 | 25 - 35 - 50 sq.mm |
| 723 | 70 - 95 - 120 - 150 sq.mm |
| 724 | 185 - 240 - 300 sq. mm |
| 725 | 400 - 500 sq.mm |
| 726 | Providing and fitting of Heat Shrinkable Straight Through Joint Kit for 11 kV (E) Cable |
| 727 | 3C x 70 - 95 sq.mm |
| 728 | 3C x 120 - 185 sq. mm |
| 729 | 3C x 240 - 300 sq.mm |
| 730 | 3C x 400 - 500 sq.mm |
| 731 | 1C x 35 - 50 sq.mm |
| 732 | 1C x 70 - 95 - 120 sq.mm |
| 733 | 1C x 150 - 185 sq.mm |
| 734 | 1C x 240 -300 sq.mm |
| 735 | 1C x 400 - 500 - 630 sq.mm |
| 736 | 1C x 630 - 800 - 1000 sq.mm |
| 737 | Providing and fitting of Heat Shrinkable Straight Through Joint Kit for 33 kV (E) Cable |
| 738 | 3C x 35 - 50 - 70 sq.mm |
| 739 | 3C x 95 - 120 - 150 sq. mm |
| 740 | 3C x 185 sq.mm |
| 741 | 3C x 240 sq.mm |
| 742 | 3C x 300 sq.mm |
| 743 | 3C x 400 sq.mm |
| 744 | WIRING |
| 745 | Providing and fitting of PVC insulated 1100V flexible copper cable (Heat Resistant Flame Retardant HRFR) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab) |
| 746 | 1.0 sqmm |
| 747 | 1.5 sqmm |
| 748 | 2.5 sqmm |
| 749 | 4.0 sqmm |
| 750 | 6.0 sqmm |
| 751 | 10.0 sqmm |
| 752 | 16.0 sqmm |
| 753 | 2x1.5 sqmm |
| 754 | 2x2.5 sqmm |
| 755 | 2x6 sqmm |
| 756 | CONDUITS |
| 757 | Providing and fixing 25mm uPVC round conduit (medium) with allied PVC fittings |
| 758 | Providing and fixing uPVC trunking 25x16mm with allied fittings |
| 759 | Providing and fixing Polypropylene Corrugated flexible conduit |
| 760 | Providing and fitting perforated, powder coated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders or fixing on cantilever supports and including painting etc as required. |
| 761 | 100 x 50 x 1.6mm |
| 762 | 150 x 50 x 1.6mm |
| 763 | Electrical fitting Items |
| 764 | Providing and fitting of various electrical fittings as under(Preferred makes: Anchor/ SSK/ Havells) |
| 765 | Switch-6A-SP-1way, 240V, 50 Hz, AC. |
| 766 | Switch-6A-SP-2way, 240V, 50 Hz, AC. |
| 767 | Cord Switches:- Providing and fitting of cord switch-6A-SP-1way, 240V, 50 Hz, AC/ hanging bell push. |
| 768 | Bell push 240V, 50 Hz, AC. |
| 769 | 6A Socket:- Providing and fitting of 6A-2/3 pin-universal socket, 240V, 50 Hz, AC. |
| 770 | Neon indicator |
| 771 | Mini telephone jack |
| 772 | Fan regulator (Mini) with rotary step |
| 773 | Fan regulator (Deluxe) with rotary step |
| 774 | Shuttered-3 pin socket and switch (box/ recessed) - 20A-SP-1 way, 230V 50 Hz, AC. |
| 775 | Plug Top 15/16A 3 Pin (ISI Marked) |
| 776 | 32A TP switch 415V with neon |
| 777 | 32A DP switch 240V with neon |
| 778 | Surface mounting box for switches as follows: |
| 779 | 1 Gang box |
| 780 | 2 Gang box |
| 781 | 3 Gang box |
| 782 | 4 Gang box |
| 783 | 5 Gang box |
| 784 | 6 Gang box |
| 785 | 7 Gang box |
| 786 | 4 Gang box (double domestic) |
| 787 | Providing, Fixing, Testing of 6A ceiling rose |
| 788 | Providing and installation of Pendant/ angle/ batten holders6A 240V |
| 789 | Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo) |
| 790 | 4 way |
| 791 | 8 way |
| 792 | 12 way |
| 793 | 16 way |
| 794 | Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider) |
| 795 | 6-32A SP |
| 796 | 40A SP |
| 797 | 6-32A DP |
| 798 | 40A DP |
| 799 | 100A 4P isolator |
| 800 | Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T) |
| 801 | 2-pole 16A 415V |
| 802 | 2-pole 32A 415V |
| 803 | 4-pole 32A 415V |
| 804 | 4-pole 63A 415V |
| 805 | 4-pole 100A 415V |
| 806 | Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under (Preferred make: Havells/ SSK/ L&T) |
| 807 | 63A 415V |
| 808 | 100A 415V |
| 809 | 200A 415V |
| 810 | Providing and installation of various type of fans as under:(Preferred makes: Havells/ Orient/ Crompton) |
| 811 | Industrial exhaust fan 450mm metallic |
| 812 | Exhaust fan 250mm Plastic |
| 813 | Ceiling fan 1200mm sweep |
| 814 | Wall fan 300mm sweep Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail