| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. -All kinds of soil |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil |
| 3 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stoneaggregate 20 mm nominal size) |
| 5 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement--All work upto plinth level. 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size). |
| 7 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five levelexcluding the cost of centring, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate20 mm nominal size) |
| 8 | Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank |
| 9 | Centering shuttering including struttings, propping etc. and removal of form work for: Columns, Pillars, Piers, Abutments, Posts and Struts with wooden plank |
| 10 | Centering shuttering including struttings, propping etc. and removal of form work for: Lintels, beams, plinth beams, girders, bressumers and cantilevers with wooden plank |
| 11 | Centering shuttering including struttings, propping etc.and removal of form work for: Suspended floors, roofs, landings, balconies and accessplatform with 12 mm thick shuttering ply |
| 12 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 13 | First class brick work in foundation and plinth including cost of all materials as required complete: cement mortar (1:4) |
| 14 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- |
| 15 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:- Using M.S. angels 40x40x6 mm for diagonal braces. Door. |
| 16 | Providing and laying cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate) flooring finished with a floating coat of neat cement including cement slurry, rounding of edges and strips etc. complete. 40 mm thick with 20 mm stone aggregate |
| 17 | 12 mm cement plaster of mix. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 18 | 15mm cement plaster on the rough side of single or half brick wall of mix. Cement mortar 1:4 (1 cement : 4 fine sand) |
| 19 | Distempering with 1st quality acrylic distemper (readymixed) having VOC content less than 50 grams/ litre, ofapproved brand and manufacture to give an even shade[Payment shall be made after submission of TestCertificate issued by the Manufacturer] :New work ( two or more coats) over and including waterthinnable priming coat with cement primer. |
| 20 | Finishing walls with premium acrylic smooth exterior paint with Silicon additives of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats applied @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 21 | Finishing with Epoxy paint ( two or more coats) of approved brand and manufacture at all locations prepared and applied as per manufacturer's specification including appropriate priming coat, preparation of surface etc. complete [Payment shall be made after submission of Test Certificate issued by the Manufacturer]. |
| 22 | Neat Cement Punning |
| 23 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid. |
| 24 | Providing and fixing 1st class quality ceramic glazed walltiles conforming to IS : 15622 - 2017 (thickness to bespecified by the manufacturer) of approved make in allcolours, shades of any size as approved by Engineer-inchargein skirting, risers of steps and dados, laid over 12mm thick bed of cement mortar 1 : 3 (1 cement : 3 finesand) jointed with ordinary cement slurry includingpointing with white cement mixed with pigment ofmatching shade etc. all complete as per direction of theEngineer in-charge.600 mm X 250 mm in all shades and design |
| 25 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement andmaking necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 26 | Providing and fixing white vitreous china laboratory sinkincluding making all connections excluding cost offittings:Size 450x300x150 mm. |
| 27 | Making connection of G.I. distribution branch with G.I. main following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete as per CPWD specification and direction of the Engineer - in - charge. 25 to 40 mm nominal bore each . |
| 28 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: Coupler, 75 mm |
| 29 | Honey comb brick masonry work of half brickthickness with first class bricks in superstructure forall level including cost of all materials as requiredcomplete:- In cement mortar 1:3 ( 1 cement : 3 fine sand ). |
| 30 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 fine sand) for fire hydrants, with C.I. surface box 350x350 mm. top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With Second Class bricks |
| 31 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R plain & brass threaded polypropylene random fittings including trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. PN-16 Pipe, 16 mm OD (SDR-7.4) |
| 32 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R plain & brass threaded polypropylene random fittings including trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. PN-16 Pipe, 20 mm OD (SDR-7.4) |
| 33 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R plain & brass threaded polypropylene random fittings including trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. PN-10 Pipe, 110 mm OD (SDR-11) |
| 34 | Providing and fixing brass bib cock of approved quality.15mm nominal bore |
| 35 | Providing and fixing soil, waste and vent pipes: 100 mm dia. Sand cast iron S&S pipe as per IS: 1729. |
| 36 | Providing and fixing hand rail using structural steel etc. of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer complete as required:-G.I.pipes. |
| 37 | Providing and fixing precast chequered cement concrete tiles 18 mm thick, laid in footpath & courtyard, on 20 mm thick bed of cement mortar 1 : 4 ( 1 cement : 4 fine sand ) jointed with neat cement slurry including rubbing and cleaning complete as per direction of the Engineer-in Charge |
| 38 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 6 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: Single socketed pipe - 110 mm OD |
| 39 | Providing and laying 1st class quality ceramic floor tilesin different sizes (thickness to be specified by themanufacturer) of 1st quality conforming to IS : 15622 -2017 of approved make in colours such as White, Ivory,Grey, Fume Red Brown, laid over 20 mm thick cementmortar 1:4 (1 cement : 4 fine sand), Jointing with greycement slurry @ 3.3 kg/sqm including pointing the jointswith white cement and matching pigment etc. allcomplete as per direction of the Engineer in-charge.. Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles 600 mm x 600 mm in all shades and designs 1st classquality ceramic floor Porcelain tiles |
| 40 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour.600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. Please Enable Macros to View BoQ information |