| 1 | APPENDIX A- CIVIL WORKS |
| 2 | 21.1.1.2Providing and fixing aluminium work for doors, windows, ventilators and partitionswith extruded built up standard tubular sections/ appropriate Z sections and othersections of approved make conforming to IS : 733 and IS: 1285, fixing with dashfasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dashfasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) |
| 3 | 21.1.2.2For shutters of doors, windows & ventilators including providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including thecost of EPDM rubber/ neoprene gasket required (Fittings shall be paid forseparately)Powder coated aluminium (minimum thickness of powder coating 50micron) |
| 4 | 21.3.1Providing and fixing glazing in aluminium door, window, ventilator shutters andpartitions etc. with EPDM rubber / neoprene gasket etc. complete as per thearchitectural drawings and the directions of Engineer - in -Charge. ( Cost ofaluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mmthickness (weight not less than 10kg/sqm) |
| 5 | 21.2.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layeror graded wood particle board conforming to IS : 12823 Grade I Type II, in panellingfixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination onboth sides |
| 6 | 21.17Providing and fixing anodised aluminium grill ( anodised transparent or dyed torequired shade according to IS : 1868 with minimum anodic coating of grade AC 15)of approved design/pattern, with approved standard section and fixed to the existingwindow frame with C.P brass/stainless steel screws @ 200 mm centre to centre,including cutting the grill to proper opening size for fixing and operation of handlesand fixing approved anodised aluminium standard section around the opening, allcomplete as per requirement and direction of Engineer-in-charge.(Only weight of grillto be measured for payment ). |
| 7 | 9.100.1Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:125 mm |
| 8 | 9.83Providing and fixing aluminium die cast body tubular type universal hydraulic doorcloser (having brand logo with ISI, IS : 3564, embossed on the body, door weightupto 35 kg and door width upto 700 mm), with necessary accessories and screws etc.complete. |
| 9 | 9.97.5Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating notless than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:100x10 mm |
| 10 | 21.13Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pairof handles ( best make of approved quality ) for aluminum doors including necessarycutting and making good etc. complete |
| 11 | 10.16.3Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trussesetc., including cutting, hoisting, fixing position and applying a priming coat ofapproved steel primer, including welding and bolted with special shaped washers etc.complete.Electric resistance or induction butt welded tubes |
| 12 | 85.103Supply of MS checquered plates including cost of conveyance charges |
| 13 | OD44199/2024-2025Providing and fixing 16mm thick ply wood with thick lamination confirming to IS710 to frame backing or studdingwith screws etc complete.(16mm thick modified9.17.1)(Frames backing or studding to be paid seperately) Details of cost of350x200cm=7sqm. wastage -5%=0.36=7.35sqm |
| 14 | OD46776/2024-2025Supplying and fixing Cupboard using 16mm,12mm and 9 mm laminated plywood,laminations using hot pressed mica etc complete (cost of 1.00 x 1.8 x 0.45cupboard)(16mm for vertical and horizontal 5 x 1 x 0.45 horizontals and 3 x 0.45x1.80 verticals =2.25 + 2.43 = 4.68 m2 12mm for doors 2x 0.5 x 1.8 = 1.8 mm 2 9 mmfor backside 1 X 1.8 add 10 % of wastage ( mica sheets sticking all sides ofcupboard = 2(4.68+1.80+1.80)=16.56 m2 + wastage 10 % = 1.66 = 16.56 + 1.66 =18.22 |
| 15 | OD44842/2024-2025Supplying and Fixing Telescopic Drawer Channel |
| 16 | OD44847/2024-2025Supplying and Fixing Brass Cupboard Knob |
| 17 | 13.83.1Wall painting with premium acrylic emulsion paint of interior grade, having VOC(Volatile including applying additional coats wherever required to achieve even shadeand colour.One coat |
| 18 | 13.62.1Painting with synthetic enamel paint of approved brand and manufacture of requiredcolour to give an even shade:Two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand and manufacture . |
| 19 | APPENDIX B - ELECTRICAL WORKS |
| 20 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 21 | 1.14.1Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 22 | 1.14.2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 23 | 1.14.3Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface / recessedmedium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 24 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 25 | 1.28.1Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.1 or 2 Module |
| 26 | 1.17.13Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x2.5 sq. mm |
| 27 | 1.28.3Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.4 Module |
| 28 | 1.28.4Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.6 Module |
| 29 | 90.16.1.1Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.00 mm copper conductor ( 14SWG) |
| 30 | 90.16.5.1Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.00 mm (14 SWG) |
| 31 | OD44892/2024-2025Supply and providing 12x3mm brass nut and bolt etc.as required. |
| 32 | 1.28.2Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.3 Module |
| 33 | 1.28.5Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.8 Module |
| 34 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.3pin 5/6 amp socket outlet |
| 35 | 1.25Supplying and fixing two module stepped type electronic fan regulator on the existingmodular plate switch box including connections but excluding modular plate etc. asrequired. |
| 36 | 1.28.6Supplying and fixing following Modular base & cover plate on existing modularmetal boxes etc. as required.12 Module |
| 37 | 1.56Supplying and fixing suitable size Gl box with modular plate and cover in front onsurface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socketoutlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For lightplugs to be used in non residential buildings). |
| 38 | 90.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as perIS 732 as required. |
| 39 | 90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizesincluding wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mmFRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cubmeter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper windingsuitable for 230V/240V single phase AC supply |
| 40 | 90.4.6Conveyance, installation, testing and commissioning of wall mounting fans of alltypes using mounting brackets supplied along with the fan. |
| 41 | 90.4.8Charges for cutting holes suitable for accommodating exhaust fans up to 305mmsweep including plastering colour washing etc. as required. |
| 42 | 90.4.9Charges for cutting holes suitable for accommodating exhaust fans above 305mmsweep and up to 450mm sweep including plastering colour washing etc. as required. |
| 43 | 1.26Supplying and fixing modular blanking plate on the existing modular plate & switchbox excluding modular plate as required. |
| 44 | 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required |
| 45 | 90.3.24.3Supply & installation of light fittings suspended on ball & socket arrangement with19 mm down rodSupply, conveyance, installation, testing and commissioning the light fittings offollowing types made of .5mm thick CRCA sheet accessories and lamps etc.including supplying and fixing ball and socket arrangements on PVC round block,suspension down rod of 19mm dia MS conduit up to 2x30cm length includingpainting and wiring the down rod with 16/0.20mm 3 core round copper conductorflex wire conforming to relevant ISS or extending the original wiring and givingconnections etc. a required.1200 mm 1X20W LED Lamp with box type fixture |
| 46 | 90.4.10Conveyance, installation , testing and commissioning of exhaust fans of size up to450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., asrequired including giving connections with the supplied wire along with the exhaustfan. |
| 47 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 48 | 2.12.2Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.63amps |
| 49 | 2.14.1Supplying and fixing following rating, double pole, (single phase and neutral),240volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.25 amps |
| 50 | 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc.as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 51 | 1.53.1Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required1 run of Cable |
| 52 | 1.53.2Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required2 run of Cable |
| 53 | 1.53.3Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existingsurface/recessed steel/PVC conduit as required3 run of Cable |
| 54 | OD44932/2024-2025Supply and fixing of CAT 6 information Outlet (I/O) box in recess/surface withsingle port and RJ45 face plate having front access with spring shutter, easyidentification labels or RJ45 port etc.and OEM surface Box having rigid plastic body and giving connection properly with the incoming CAT 6 UTP cable, testingthe connection, making good the damges,colour washings etc (Recommended:MOLEX/D link/LEGRAND) |
| 55 | OD44940/2024-2025Supply and Installation of CAT-6 ,1 meter Patch code for interconnecting rackmounted switch and patch panels. Accepted model: D-Link / Digisol or equivalent |
| 56 | OD44947/2024-2025Supply and fixing Wall Mount 4U Rack for Port switch, Patch panel, ACDistribution box, cooling fan and hardware mounting kit.(D Link/AMP/equivalent) |
| 57 | OD44948/2024-2025Supply and installation and giving connection of 16port CAT- 6 Patch panels fullyloaded for inter connecting sever and nodes. Recommended :D link or equivalent. |
| 58 | OD44955/2024-2025Supply and fixing of 16 port GIGA Switch High speed with rack mountaccessories.(Make: Cisco /D link or equivalent) |
| 59 | OD44965/2024-2025Supply & Fixing 4 Pole enclosure MCB DB sheet steel phosphatised , painted,dust and vermin proof on surface/ recess etc. as required. |
| 60 | APPENDIX C-PLUMBING AND SANITARY WORS |
| 61 | 17.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Washbasin size 630 x 450 mm with a single 15 mm C.P. brass pillar tap |
| 62 | 50.18.9.1.2Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of joints complete as per direction ofEngineer in Charge. 15 mm dia 10Kgf/cm2 |
| 63 | 50.18.9.2.2Providing and fixing PVC pipes includings of pipes with one step PVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineerin Charge. 20 mm dia 10 Kgf/cm2 |
| 64 | 50.18.9.3.2Providing and fixing PVC pipes includes jointing of pipes with one step PVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineerin Charge. 25 mm dia 10KGF/cm2 |
| 65 | 50.18.9.4.1Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of joints complete as per direction ofEngineer in Charge.32 mm dia 10.Kgf/cm2 |
| 66 | 50.18.9.5.2Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of joints compete as per direction ofEngineer in Charge. 40 mm dia 6 Kgf/cm2 |
| 67 | 50.18.9.6.2Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of joints complete as per direction ofEngineer in Charge. 50 mm dia 6 Kgf/cm2 |
| 68 | 50.18.9.7.1Providing and fixing PVC pipes includings of pipes with one step PVC solventcement, trenching refilling & testing of joints complete as per direction of Engineer inCharge. 63 mm dia 6Kgf/cm2 |
| 69 | 50.18.9.9.1Providing and fixing PVC pipes includings jointing of pipes with one step PVCsolvent cement, trenching, refilling & testing of Joints complete as per direction ofengineer in charge.110 mm dia 6Kgf/cm2 |
| 70 | 17.28.2.1Flexible pipe32 mm dia |
| 71 | 18.15.1Providing and fixing brass bib cock of approved quality :15 mm nominal bore |
| 72 | 18.18.1Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:15 mm nominal bore |
| 73 | OD45962/2024-2025Providing and fixing125mm CP Gratings for Floor including all cost of materials andlabour charges etc. complete Please Enable Macros to View BoQ information |