| 1 | Providing and fixing of compressor including Gas charging, welding testing and refitting at site complete in all respect (change of filter, capillary and flushing etc.) Make Emerson /kiroskar /mittsubish / hitachi/blue star,carrior or as per machines requirment. (NSR) .NSR |
| 2 | 1.5 ton cap.compressor . |
| 3 | 2.0 ton cap.compressor . |
| 4 | 3.0 ton cap.compressor . |
| 5 | 11.5 ton cap.compressor . |
| 6 | Supply and fixing of R-22/R-134a/R-410A/R-32 various AC complete in all respect including change of filter, caoaillary and flushing with Nitrogen, Rectifying defector leakage etc .NSR |
| 7 | 3 ton to 5 ton AC . |
| 8 | 1.5 and 2.0 ton cap. Window A.C . |
| 9 | 1.5 and 2.0 ton split type AC . |
| 10 | Ductable AC 11 ton . |
| 11 | Providing and fixing of hard copper piping with sleeve type insulation complete in all respect for all 2.0 TR/1.5 TR AC as per direction of the EIC. .NSR |
| 12 | size -5/8 inch . |
| 13 | size-3/8 inch . |
| 14 | Repair and Replacement of AC Fan motor 1/6 HP including rewinding, rebushing, refiting at site single phase 220volts complete in all respects .NSR |
| 15 | Providing and fixing of various running capacitors mfd make: Tasla and Siemens, EPCOS,Tibcon (NSR) .NSR |
| 16 | 80/100 Mfd . |
| 17 | 36/45 Mfd . |
| 18 | 4/6 Mfd . |
| 19 | Repair and Replacement of PCB circuit for window /Split type AC of all tanage. .NSR |
| 20 | Providing and fixing of 3core wire 2.5mm2 between outdoor and indoor unit of split AC at various sites .NSR |
| 21 | Providing and fixing of PVC rigid drain pipe of Diplast make of Size (3/4) complete in all respect from indoor unit to disposal point as directed by the E.I.C. .NSR |
| 22 | Service and cleaning of split / window type /pillar type AC with the help of jet pump , cleaner complete in all respect. .NSR |
| 23 | Service and cleaning of Ductable type AC with the help of jet pump , cleaner complete in all respect. .NSR |
| 24 | Providing and fixing of sensor for cutoff AC with remote complete in all respect . |
| 25 | 2 Ton to 3 Ton window / split AC . |
| 26 | Ductable unit 8 Ton to 11 Ton . |
| 27 | Providing and fixing of fan motor for split AC including dismantelling of old motor with fitting of new motor and rebate for old material .NSR |
| 28 | Split AC-1/6 HP . |
| 29 | Providing and fixing of condenser fan blade for window/split type AC's complete in all respect .NSR |
| 30 | Providing and fixing of various type Contactor Block single phase and 3phase make: L&T Siemens .NSR |
| 31 | ML 3/CL03 3 phase . |
| 32 | ML 1.5/CL02 single phase . |
| 33 | Providing and fixing of copper piping with sleeve type insulation between outdoor and indoor unit of spilt type AC at various sides requirment/manufacture standards .NSR |
| 34 | Supply and installation and testing of microprocessor controller with wiring connector for ductable AC's (Indoor / Outdoor) complete in all respect .NSR |
| 35 | 4 Ton to 11 Ton packing unit . |
| 36 | Providing and Fixing of Voltage Stabilizers of (3 stage) with Copper winding Input range 160 to 280 Volts, Nominal output-230 Volts±10% Including cost of copper wire from stabilizer to AC unit and power plug to stabilizer upto 6m each with M.S. body of 22 gauge sheet (powder coated), complete in all respects Make Deol or Jewel Volts,V-Guard (5 KVA). .NSR |
| 37 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. .E&M DSR 20252.10 |
| 38 | Single pole and neutral .2.10.2 |
| 39 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. .E&M DSR 20252.15 |
| 40 | 63 A .2.15.3 Please Enable Macros to View BoQ information |