| 1 | Schedule 'A' |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. |
| 3 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for incl removing the debris out side the premises of MoD land of deposting at low laying area complete all as specified and directed |
| 4 | Demolition of RCC of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition).incl removing the debris out side the premises of MoD land of deposting at low laying area complete all as specified and directed |
| 5 | Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water complete all as specified and directed. |
| 6 | M&L for rendering 15mm thick in CM 1:4 on on fair surfaces of brick in two separate coats (10mm thick backing coat and 5mm thick top coat) using water proofing compound @2% by weight of cement as per manufacture instruction and finishing works/concrete surfaces finished even and smooth complete all as specified and directed.Note : (i) WPC will be measured and paid separately (ii) Rates deemed to be inclusive of scaffolding upto height 12 Mtr at reqd places. No additional payment will be made on this account. |
| 7 | Supply only intergral water proofing compound complete all as specified and directed. |
| 8 | M&L for preparation for new or previously untreated plastered surface of walls and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 9 | M & L for RCC 1:2:4 Type B1 nominal mix (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; basesfor columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 10 | M&L for RCC (Nominal Mix) type B1 1:2:4 (20mm graded stone aggregate ) as in columns,pillars,piers,posts and struts complete all as specified.(Sand :- Dimapur)Note :- Reinforcement and form work required shall be measured and paid seperately. |
| 11 | M&L for formwork to side of pillars, posts, struts, piers, columns and stanchions for square, rectangular fair finished surfaces complete all as specified and directed. |
| 12 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, flat, rough finished surface of concrete complete all as specified and directed. |
| 13 | S & F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 14 | Ditto as per items No 12.00 here-in-above but 5mm and over upto & incl 10mm dia in stirrups, spaces and binders complete all as specified and directed. |
| 15 | M&L for cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 16 | M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping including necessary formwork etc complete all as specified and directed |
| 17 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed. |
| 18 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. |
| 19 | Ditto all as per Sl item No. 17.00 here-in-above but except brick (NOTE: Seviceable brick obtained from demolition under Sl item No 16.00 here-in-above shall be reused under the item) |
| 20 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cm (1:6) complete all as specified and directed. |
| 21 | Ditto all as per Sl item No. 19.00 here-in-above but except stone (NOTE: Seviceable stone obtained from demolition under Sl item No 16.00 here-in-above shall be reused under the item) |
| 22 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling,uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc. 20mm granite or trap stone. complete all as specified and directed. |
| 23 | M&L for Raised pointing to random or polygonal rubble stone masonry, uncoursed or brought upto courses in cement mortar ( 1:4) complete all as specified and directed. |
| 24 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in ,bond stone including necessary formwork complete all as specified and as directed. |
| 25 | M & L for boulder filling dry, handpacked tightly, as in wire crate apron bunds (Wire crate measured separately) complete all as specified and as directed |
| 26 | M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in benching of drain complete all as specified and directed. |
| 27 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds, mitered /stopped ends etc. complete all as specified and directed. |
| 28 | S&F in repair 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints and fixed to wall with steel clamps or in floor as in waste/soil pipe complete all as specified and directed. |
| 29 | Dismantling floor, hearth , chequred tiles, interlocking tiles, tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 30 | M & L for 75 mm thick cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed by the Engineer-in-Charge |
| 31 | M&L for machine pressed precast conctete interlocking paver block rubber moulded any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with gray cement and pigment complete all as specified and directed. |
| 32 | M&L for precast cement concrete chequred tiles (ISI approved) of size 300mm x300mm x25mm thick, set and jointed and pointed in neat cement slurry in floor with grey cement and pigment including 15mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 33 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 34 | M&L for precast RCC 1:2:4 type B1 ( using 20mm graded stone agg) as in cover slab for manhole etc with plane faces complete all as specified and directed by Engineer-in-Charge. |
| 35 | M&L for 100 mm thick plain cement concrete type B 2, 1:2:4 (using 40mm graded stone agg) as in flooring and finishing the cement concrete surface even and smooth without using extra cement complete all as specified and as directed. |
| 36 | M&L for glass dividing strips 38mm wide and 3mm thick and inserted in position to conform to design complete all as specified and as directed. |
| 37 | S&F of Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 38 | M&L for framed work as in doors or gates of angle with ornamental and intricate design or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410 -W(Gde E- 250) quality A complete all as specified and directed. |
| 39 | S&F 1mm thick Mild steel, plain black sheet in wall cladding, steel gates and similar work, cut to size, holes punched including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams including bending or turning up, mitred angles, etc. as required complete all speciified and directed |
| 40 | M&L for preparing of new steel surfaces and applying two coat of synthetic enamel paint over one coat of red oxide primer of any description ,over 10cm in width or girth not otherwise described complete all speciified and directed. |
| 41 | S&F stainless steel letters of size 1'x1' and thickness of letter 25mm (thickness of stainless steel sheet 1mm) fixed in any position horizontaly/vertically with necessary slef tapping screws/ nut and bolts complete all as specified and directed by Engr-in-Charge |
| 42 | Fixing only steel rolling shutters, with out ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, complete push pull or manual type complete all as specified and as directed. |
| 43 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directected . |
| 44 | Dismantling of stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar complete all as specified and directed. |
| 45 | Material and labour for Granite(of any type) 18 to 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed. Please Enable Macros to View BoQ information |