| 1 | Schedule 'A' |
| 2 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for incl removing the debris out side the premises of MoD land of deposting at low laying area complete all as specified and directed |
| 3 | Demolition of RCC of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition).incl removing the debris out side the premises of MoD land of deposting at low laying area complete all as specified and directed |
| 4 | Taking down cement plaster of any description from brick wall surfaces etc including racking out joints and hacking for key, scrubbing down with water complete all as specified and directed. |
| 5 | M&L for rendering 15 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface fair and even without using extra using cement complete all as specified and directed. |
| 6 | M&L for preparation for new or previously untreated plastered surface of walls and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 7 | Dismantling of Bricks(laid flat or on edges) or brick tiles in floors, channel, kerbs, aprons laid bedded and pointed in any mortar etc complete all as specified and directed |
| 8 | M & L for providing bricks sub class ‘B’ (locally available best quality) laid flat in floor, of old size laid dry and pointed in CM 1:3 complete all as specified and directed |
| 9 | Ditto all as per Sl item No. 7.00 here-in-above but except brick (NOTE: Seviceable brick obtained from dismantling under Sl item No 6.00 here-in-above shall be reused under the item) |
| 10 | M&L for providing brick work with sub class ‘B’ (locally available best quality) Bricks laid on edge in floor, of old size bricks laid dry and pointed in CM 1:3 complete all as speified and directed. |
| 11 | Ditto all as per Sl item No. 9.00 here-in-above but except brick (NOTE: Seviceable brick obtained from demolition under Sl item No 6.00 here-in-above shall be reused under the item) |
| 12 | Demolition Cement concrete (unreinforced) in ground floors and pavings n.exc 15 cm thickness below or above ground level complete all as specified and as directed |
| 13 | M & L for PCC 1:3:6 type C2 (using 40 mm graded stone aggregates) as in surface channel and drain complete all as specified and directed. |
| 14 | M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping and bonders (for stone walling) etc incl necessary formwork etc complete all as specified and directed. |
| 15 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds, mitered /stopped ends etc. complete all as specified and directed. |
| 16 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed. |
| 17 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted built in cm (1:6) complete all as specified and directed. |
| 18 | Ditto all as per Sl item No. 16.00 here-in-above but except stone (NOTE: Seviceable stone obtained from demolition under Sl item No 15.00 here-in-above shall be reused under the item) |
| 19 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling,uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc. 20mm granite or trap stone. complete all as specified and directed. |
| 20 | M&L for Raised pointing to random or polygonal rubble stone masonry, uncoursed or brought upto courses in cement mortar ( 1:4) complete all as specified and directed. |
| 21 | M & L for boulder filling dry, handpacked tightly, as in wire crate apron bunds complete all as specified and as directed. |
| 22 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. |
| 23 | Ditto all as per Sl item No. 21.00 here-in-above but except brick (NOTE: Seviceable brick obtained from demolition under Sl item No 15.00 here-in-above shall be reused under the item) |
| 24 | M&L for cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed. |
| 25 | S&F in repair 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed. |
| 26 | M & L for 75 mm thick cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) as in sub base/plinth protection/hardstanding complete all as specified and as directed by the Engineer-in-Charge |
| 27 | M&L hardcore of gauge n exc 63mm, broken stone or boulders deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface completed all as specified and directed. |
| 28 | Dismantling floor, hearth , chequred tiles, interlocking tiles, tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 29 | M&L for precast cement concrete chequred tiles (ISI approved) of size 300mm x300mm x25mm thick, set and jointed and pointed in neat cement slurry in floor with grey cement and pigment including 15mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 30 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. |
| 31 | S&F of Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 32 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 33 | M&L for precast RCC 1:2:4 type B1 ( using 20mm graded stone agg) as in cover slab for manhole etc with plane faces complete all as specified and directed by Engineer-in-Charge. |
| 34 | M&L for preparation of new or previously untreated surfaces of steel of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 35 | M & L for PCC 1:3:6 type C2 (nominal mix) concrete bed to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 36 | M & L for PCC 1:3:6 type C2 (nominal mix) concrete bed to 300mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 37 | Demolition and breaking up 150mm drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 38 | Demolition and breaking up 300mm drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 39 | M&L for 150mmdia reinforced concrete pipes class NP-2 laid and jointed complete with collars complete all as specified and directed. |
| 40 | M&L for 300mmdia reinforced concrete pipes class NP-2 laid and jointed complete with collars complete all as specified and directed. Please Enable Macros to View BoQ information |