| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Certain misc repairs to drain, fencing, gates, pathway, boundary wall etc at New Mil Stn Kapurthala under GE Kapurthala Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Dismantling of brick work built in cement mortar including quoins ,arches and pillars etc. all as specified and directed by Engineer-in -Charge. |
| 3 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer- in-Charge. |
| 4 | Taking down cement plaster on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified and directed by Engineer- in-Charge . |
| 5 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:4 complete all as specified and directed by Engineer- in-Charge . |
| 6 | - ditto - all as per item No. 4 here in before but except bricks including cleaning from mortar complete all as specified and directed. |
| 7 | M&L for brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed by Engineer- in-Charge. |
| 8 | - ditto - all as per item No. 6 here in before but except bricks including cleaning from mortar complete all as specified and directed. |
| 9 | Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises |
| 10 | M&L for cement concrete 1:5:10 type E-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed by Engineer- in-Charge . |
| 11 | M&L for cement concrete (1:2:4) B-1 using 20mm graded stone aggregate as in lintels up to 1.5 m clear span, benching, coping, bed blocks etc including use of necessary form work complete all as specified and directed by Engineer- in-Charge . |
| 12 | Providing precast cement concrete Type B0 1:2:4 set in cement mortar 1:4 louvres and jallies, 40mm thick measured solid, including all mouldings but excluding frame (Pre cast frame shall be measured separately) all as specified and directed by Engineer- in-Charge. |
| 13 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge. |
| 14 | M&L for machine pressed precast conc. interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade with grey cement and pigment complete all as specified and directed by Engineer- in-Charge. |
| 15 | M&L for chequered coloured cement concrete tiles 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry and pigments as in floors over 15mm thick screed bed in cement mortar 1: 6 complete all as specified and directed by Engineer- in-Charge . |
| 16 | M&L for rendering 15mm thick on fair faces or other than fair faces of brick work in cement mortar 1:4 finished even and smooth without using extra cement all as specified and directed. |
| 17 | M&L for preparation of plastered and un plastered surface of wall by applying two coat of exterior emulsion paint over a coat of primer complete all as specified and directed. |
| 18 | M&L for keyed pointing to brick work as in cement mortar (1:4) omplete all as specified and directed by Engineer-in-Charge |
| 19 | M&L for vitrified ceramic coloured tiles 10 mm thick light shade (square/rectangular) area of each tile n.exc 0.36 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, with 15 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed by Engr-in-Charge |
| 20 | M&L for preparation of old Plastered or Unplastered surface of wall shall include brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying two coat of exterior emulsion paint complete all as specified and directed by Engineer-in-Charge |
| 21 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed y Engineer-in-charge. |
| 22 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, confirming to GDE Fe410-O or Fe-310-O complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L for 50 mm thick cement conrete1:2:4 type B–1 using 20mm graded stone aggregates flooring finished even and smooth without using extra cement all as specified and directed by Engineer-in-Charge . |
| 24 | M&L for glazed ceramic coloured tiles of size 450X 300X (7-8mm thick) as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer- in-Charge. |
| 25 | M&L for non skid ceramic coloured tiles with matt finish, 6 to 8 mm thicksquare or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm and shall be jointed in neat cement slurry and pointed in paste pigmented to tile shade as in floors over 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed by Engineer- in-Charge. |
| 26 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in conc or brick masonary and making good disturbed ground all as specified and directed by Engineer- in-Charge. |
| 27 | Dismantling fencing wire mesh, any type, any size all as specified and directed by Engineer- in-Charge. |
| 28 | M&L for mild steel work as in posts, struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290. Gde E-165 complete all as specified and directed by Engineer- in-Charge. |
| 29 | S&F in repairs galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at cross with and provision of galvanised mild steel wire, staples or steel pins etc all as specified and directed by Engineer- in-Charge. (Each line to be measured separately) |
| 30 | Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed by Engineer- in-Charge. |
| 31 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire |
| 32 | M&L for steel round bars Fe-410 -W (Gde E-250) 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 33 | S&F of MS screw bolts (machine made) with hexagonal or square head at one end, screwed end to be fitted with washer and one hexagonal / square nuts exc 10 cm and not exc 15mm , dia of neck 5 to 10mm all as specified and directed by Engineer- in-Charge. |
| 34 | M&L for applying two coats of synthetic enamel paint on preparation of newly steel surfaces over a coat of Zinc chromate primer any description over 10 cm width of girth not otherwise described all as specified and directed by Engineer- in-Charge . |
| 35 | M&L for applying two coats of synthetic enamel paint on preparation of old brick/Kerb stone/ concrete surfaces and repair demaged portion by any means like plastering and concreting any description over 10 cm width or girth not otherwise described all as specified and directed by Engineer- in-Charge . Note : cost of repairing of demaged portion is included in this item. |
| 36 | Dismantling of existing drain removing of mud, soil, etc for a depth of 1m and deposit at 500m away from the site complete all as spefied and directed by Engineer-in-Charge. |
| 37 | Excavation in post holes (or similar holes) each n.exc 0.5 cum, getting out , returning filling in layers not exceeding 25cm including watering and ramming and removing surplus earth to a distance not exceeding 50 metre complete all as specified. |
| 38 | M&L for plain cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |