| 1 | Excavation in trenches n. exc 1.5m wide and n. exc 1.5m in depth in hard/dense soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm on plan and getting out complete all as specified and directed |
| 2 | Removing excavated material (any type of soil) to a distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed |
| 3 | Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed |
| 4 | M&L Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete complete all as specified and as directed |
| 5 | M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in cement mortar 1:4 all as specified |
| 6 | M&L for PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in coping including necessary form work complete all as specified |
| 7 | M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in surface channel or drain or benching in manhole including necessary formwork complete all as specified and directed |
| 8 | M&L for 10mm thick plaster in CM (1:4) on fair faces of concrete/PCC block surfaces of walls finished even and fair (without using extra cement) all as specified. |
| 9 | M&L for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitered/stopped ends etc complete all as specified and directed |
| 10 | Returning filling in hard/dense soil including spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed |
| 11 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290, Gde-E-165 all as specified and as directed |
| 12 | M&L for providing precast reinforced cement concrete cover slabs for drain in RCC (1:2:4) B-1, using 20mm graded aggregate set in cement mortar 1:4 complete all as specified and as directed. |
| 13 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia for securing with clips quality conforming to deformed or twisted bars. |
| 14 | Demolition of reinforced cement concrete of any description (reinforcement cut as required to facilitate demoltion) and in any position not otherwise specifically provided for complete all as specified and directed |
| 15 | Excavation in trenches n. exc 1.5m wide and n. exc 1.5m in depth in hard/dense soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm on plan and getting out complete all as specified and directed |
| 16 | M&L for design mix M-30 (using 20mm graded crushed stone aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 17 | M&L for design mix M-30 (using 20mm graded crushed stone aggregate) in columns, pillars, piers, posts and struts complete all as specified and directed |
| 18 | M&L for design mix M-30 (using 20mm graded crushed stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed |
| 19 | M&L formwork for rough finished flat surface to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter complete all as specified and directed |
| 20 | M&L formwork for rough finished surface of square, rectangular or triangular surface to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed |
| 21 | M&L formwork for rough finished flat surface to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup-ports, overhangs, etc also splays between floors and beams, etc complete all as specified and directed |
| 22 | M&L for mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed |
| 23 | M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified and directed |
| 24 | M&L for broken glass coping on top of security wall in cement mortar 1:3 complete all as specified and directed |
| 25 | M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed |
| 26 | S&F Galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed |
| 27 | S&F concertina coil with punched tape 600 mm dia with wire diameter 2.6 mm and razor size 15mmx12mmx0.5mm, spacing of blade 26mm, fixed on angle iron frames over RCC or brick post/wall including securing or tying at crossing with and provision of galvanised mild steel wire, staple or steel pins etc complete all as specified and as directed. The razor tape should have minimum galvanised coating thickness 12 microns (both side inclusive). The concertina coil should have as per relevant IS and should be hot dip galvanised coated with CLR anticorrosive paint by making diamond shape with the help of dove tail clips (18 SWG) fixed over razor wire with the help of hug ringes (14 SWG) complete all as specified and directed |
| 28 | Dismantling wrought iron or mild steel work of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 29 | Surface excavation n. exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in hard dense soil |
| 30 | M & L for hardcore of gauge n exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface of broken stone or boulders |
| 31 | M & L for providing 75 mm thick, PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base of floors |
| 32 | M & L for providing 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in floors finishing the surface of concrete topping even and fair without using extra cement, complete all as specified and as directed |
| 33 | M&L chequered Cement concrete tiles 30 cmx30cmx 25 mm thick set, jointed and pointed neat cement slurry in floor with grey cement and pigments , incl CM (1: 4) 20 mm thick screed bed all as specified and directed by Engr-in-Charge. |
| 34 | M&L for 16-18mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admix ture of pigment to match with shade of granite complete all as specified. |
| 35 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed |
| 36 | S&F framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works including ornamental and intricate design conforming to Fe-290, Gde-E-165 all as specified and as directed. |
| 37 | M&L for complete removal of existing treatment on plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed Please Enable Macros to View BoQ information |