| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (Army) Ahmedabad NAME OF WORK : REPAIR/REPLACEMENT OF SEWAGE LINE AND OTHER CONNECTED WKS UNDER ZONE A OF GE AHMEDABAD CONTRACT AGREEMENT: GE (A)/ABD/ OF 2026-2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item of Work Item Code / Make Quantity Unit Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT (in Words) |
| 2 | Cleaning and desilting of manholes not exceeding 1.5metre deep by pumping manually with required rope, buckets and ladders and depositing the sludge at distance not exceeding 50 metre and then removing sludge outside ministry of defence land and complete all as specified and as directed |
| 3 | All as per item No 1 above but depth of manholes exceeding 1.5 metre but not exceeding 3.00 metre complete all as specified and as directed |
| 4 | Cleaning of sewer line 150mm internal dia to 300mm internal dia depth upto 1.5 metre by removing blockage/chocking/obstruction of flow and making free flow by rodding with steel rods and finally passing the rope through the line with jute cloth for cleaning the chocked/blocked sewer line complete all as specified and as diected |
| 5 | All as per item No 3 above but depth exceeding 1.50 metre not exceding 3.00 metre complete all as specified and as directed |
| 6 | All as per item No 3 above but depth exceeding 3 metre but not exceeding 4.00 metre complete all as specified and as directed |
| 7 | M & L for pumping out sewage water from the blocked manhole for cleaning the existing line through diesl pump set 7.5 HP & disposal of sludge as directed |
| 8 | M & L cleaning of heavy blockage sewage line above 3.00 metre depth by mechanically operated jetting machine with pressure water supply complete all as specified and as directed |
| 9 | Removing of blockage/chocked up water closet by rodding upto first manhole including testing complete all as specified and as directed |
| 10 | Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.5 metre deep for foundation etc., for shafts, wells cess pits manholes etc., not exceeding 10 sqm on plan and not exceeding 1.5 metre depth in soft/loose soil and getting out complete all as specified and as directed |
| 11 | Excavation in trenches not exceeding 1.50 metre wide for foundation etc., for shafts, wells cess pits,manholes etc., not exceeding 10 sqm on plan and exceeding 1.5 metre and not exceeding 3.0 metre depth in soft/loose soil and getting out complete all as specified and as directed |
| 12 | Demolition and breaking up drain pipes (SGSW) set in CM including concrete bed haunching of any description for all as specified and directed for 150mm internal dia of pipes. |
| 13 | Demolition and breaking up drain pipes (SGSW) set in CM including concrete bed haunching of any description for all as specified and directed for 200mm internal dia of pipes. |
| 14 | Demolition of cement concrete of any description and in any position not otherwise specially provided for complete all as specified and as directed |
| 15 | M&L for 150mm bore RCC Class NP-2 pipe with colars laid in trenches, jointed as specified. |
| 16 | M&L for 200mm bore RCC Class NP-2 pipe with colars laid in trenches, jointed as specified. |
| 17 | M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) bedding to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm internal dia of pipes |
| 18 | M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) bedding to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm internal dia of pipes |
| 19 | M&L for cement concrete 1:3:6, type C2 (using 40mm graded stone aggregate) in foundations, filling & mass concrete all as specified and directed |
| 20 | M&L for cement concrete 1:2:4, type B1 (using 20mm graded stone aggregate) as in coping, benching, kerb etc., rounded or chamfered on edges including necessary form work all as specified and directed |
| 21 | Demolition of Brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed |
| 22 | M&L for brick work with sub class 'B' bricks built in cement mortar (1:4) straight or curved on plan & exc 6 metre mean radius with old size bricks all as specified and directed |
| 23 | Returning, filling in trenches including spreading levelling, watering well ramming in layers not exceeding 25 centimetre in soft/loose soil (from available soil) complete all as specified and as directed |
| 24 | Removal of excavated material such as soils to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed |
| 25 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed |
| 26 | M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete surfaces with even and smooth finish without using extra cement all as specified and directed |
| 27 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching and forming branch channel in PCC (1:2:4) type B1 (using 20 mm graded stone aggregate), smooth finished all as specified for 150mm internal dia of pipes |
| 28 | All as per item No-26 above but 225mm internal dia of pipe complete all as specified and as directed |
| 29 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed |
| 30 | S&F factory made 50mm thk precast man hole cover , Size 1500mmx300mm of min strength of manhole cover should not be less than M - 25 complete all as specified and directed |
| 31 | S&F factory made 50mm thk precast man hole cover , Size 1200mmx300mmof min strength of manhole cover should not be less than M - 25 complete all as specified and directed |
| 32 | S&F factory made 50mm thk precast man hole cover , Size 600mmx300mm of min strength of manhole cover should not be less than M - 25 complete all as specified and directed |
| 33 | S&F factory made 50mm thk precast man hole cover , Size 1000mmx300mm of min strength of manhole cover should not be less than M - 25 complete all as specified and directed |
| 34 | M&L for providing precast reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) as in landings, cover slabs(for manholes etc.,) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 all as specified and directed |
| 35 | S&F steel bars 6mm to 8mm dia TMT bars and cut to length bent to hape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips quality complete all as specified and as directed |
| 36 | Dismantling cast iron or reinforced cement concret drain pipes jointed in cement mortar and taking out of trenches if required for internal dia of pipe upto 100mm incl all fittings (Tee, bend branches pieces etc,.) |
| 37 | S & F for cast iron soil, waste and vent pipe of 100mm bore (sand cast pipes) in any length, with or without ears, with cement joints fixed to walls. |
| 38 | S & F for cast iron soil, waste and vent pipe of 75mm bore (sand cast pipes) in any length, with or without ears, with cement joints fixed to walls. |
| 39 | S & F bends (any radius), diminishing pieces or tapers (larger bore measured) bore of bends 100mm complete all as specified and as directed |
| 40 | All as per item No 38 hereinbefore but 75 mm bore complete all as specified and as directed |
| 41 | S & F cast iron branch piece, single (Y junctions equal or unequal) ordinary or inverted ( spigot or socket type) or parallel branches laid and jointed, of 75mm dia bore complete |
| 42 | S & F cast iron branch piece, single (Y junctions equal or unequal) ordinary or inverted ( spigot or socket type) or parallel branches laid and jointed, of 100mm dia bore complete |
| 43 | Material & labour for 150 x 150mm size salt-glazed stoneware gully traps, square or round mouthed, type 'P' in repairs complete all as specified |
| 44 | S&F in repairs PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints, laid in wall, trenches or in floors complete all as specified and as directed |
| 45 | S&F in repairs PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, laid in wall, trenches or in floors complete all as specified and as directed |
| 46 | S & F in repairs PVC(SWR) bends 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 47 | S & F in repairs PVC(SWR) bends 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed |
| 48 | S &F vitreous china water closet Squatting Orissa patern white size 580 x 440mm with integral foot rest with P or S trap including connecting to fushing cistern low or high level, 32mm dia polyethylene fush pipe etc compete all as specified.(excluding cost of flush tank) including provn of lime concrete bedding complete all as all as specified and directed. |
| 49 | S & F in repair vitreous china wash down water closet pan (pedestral pattern), white including connection trap and to flushing pipe, anti-syphnoge pipe etc complete including complete all as all as specified and directed. |
| 50 | M&L 75mm thick PCC (1:3:6) type C2 as in plinth protection/footpath using 40mm graded stone aggregate finishing cement concrete surface even & smooth without using extra cement including bitumen filling in between panels etc complete all as specified and as directed. Total in Figures 0.0 23 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |