| 1 | Taking down existing unserviceable street/security light fittings along the perimeter wall/ fencing/ Street light by using ladder in hilly areas, any type of security light fitting of any capacity any type from pole/wall after disconnection from the connecting wires, carrying to store yard for necessary repair/replacement of spares etc complete all as specified and as directed. |
| 2 | Refixing only the street light fittings after repair along the perimeter wall/fencing /Street light by using ladder in hilly areas, obtained from item No.01 here in before including making connections with cables and testing complete all as specified and as directed. Note for Item Nos. 1 & 2 : (a) Any new spares including cable required to be replaced shall be measured and paid separately. (b) Necessary T&P, Safety Belt, Aluminium Ladder, Vehicle etc required for taking down will be arranged by the Contractor and cost for the same shall deemed to be included in the Quoted Unit Rate. |
| 3 | Supply and laying of XLPE under ground insulated, armoured, heavy duty LT 1100 volts 16 Sqmm 4 core grade cable with aluminium conductor ISI marked, laid in trenches/pipes, fixed to poles/walls with suitable saddle & glands complete all as directed including taking out the old burnt out cables all as specified and directed by Engr-in-Charge. |
| 4 | All as Srl item No. 3.00 above but of size 4 core 25 Sqmm |
| 5 | All as Srl item No. 3.00 above but of size 3.5 core 35 Sqmm |
| 6 | All as Srl item No. 3.00 above but of size 3.5 core 50 Sqmm |
| 7 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth and getting out in any type of soil for taking up or laying of cable all as specified and directed. |
| 8 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed. |
| 9 | Removal of surplus soil not exceed to a distance of 50M where directed at a level not exc 1.5M above the starting point |
| 10 | Supply and laying dry river sand laid in trenches as cable cushioning and covering complete all as specified and directed. Note : Punned thickness shall be measured and paid |
| 11 | M & L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed. |
| 12 | M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 2.5 sqmm including taking down existing unserviceable wire complete all as specified and directed by Engineer-in-Charge. |
| 13 | M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 6 sqmm including taking down existing unserviceable wire complete all as specified and directed by Engineer-in-Charge. |
| 14 | M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 10 sqmm including taking down existing unserviceable wire complete all as specified and directed by Engineer-in-Charge. |
| 15 | M & L in repair PVC insulated, PVC Sheathed flat twin core cable with stranded aluminium conductor of size 16 sqmm including taking down existing unserviceable wire complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down existing unserviceable light fitting, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, including taking down existing unserviceable light fitting, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, including taking down existing unserviceable light fitting, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply and fix Integral LED aviation light luminaire, 5 watt, 230 V AC, comprising of yellow painted LM6 aluminium alloy housing polycarbonate enclosure including taking down existing unserviceable aviation light fitting complete all as specified and directed by Engineer-in-Charge. |
| 20 | Taking down in repair of high mast light, Hot dip galvanised Mast 15/16meter high and Luminaires carriage duly opening of nut & bolt at bottom with the help of Hydra/Crane for repair/replacement of old unserviceable Winch and steel wire ropes (as per existing) complete with ratchet, limit switches etc as per standard engineering practice to avoid falling of carrier during raising or lowering and re-installation, testing at site and comissioning after satifactorily repair complete all as specified and directed. |
| 21 | Taking down of old unserviceable street light timer switch board of any type and supply, installation, testing and commissioning of street light distribution boards 12 KW, Digital 24 Hour capacity, 3 pole, 415 volt, made out of 3.15mm thick CRCA Steel Sheet with front openable door fitted with necessary hinges, door locking by Panel lock and provision for Pad Locking duly phosphatized and powder coated and conforming to IP 54 degree of protection, complete suitable for wall mounting/ pole mounting with suitable clamps, nuts & bolts etc, internally pre-wired with suitable guage of copper wires and connecting up all incoming and outgoing cables with suitable cable glands, lugs, nuts, bolts and washers complete suitable for accommodating and including provision of following switchgears/ components :-a) Incoming MCB 63 Amp TPN - 01 No.b) 3 pole contactor 65 Amp - 01 No.d) Timer switch Digital type, 24 Hour - 01 No.e) Auto/Manual selector Switch - 01 No. |
| 22 | Supply and fixing in replacement of post top lantern LED type 20 watt, 230 V AC outdoor type with decorative post top for 360 degree indirect light with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down existing unserviceable light fitting, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply and fixing in replacement of post top lantern LED type 40 watt, 230 V AC outdoor type with decorative post top for 360 degree indirect light with IP66 protection, with impact and corrosion resistant complete with driver and lamp including taking down existing unserviceable light fitting, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Taking down solar street light fitting from pole for repairing work in inbuit solar street light fitting including replacement of solar PV module, battery, LED strips, sensors etc., testing and refixing the same on existing pole complete all as specified and directed. |
| 25 | Note :- An amount of Rs. Rs 13,730.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |