| 1 | Demolition of cement concrete (Un reinforced) in ground floor & pavings n.exc 15 cm thickness (below or above GL) and removing debries out side MOD land, complete all as specified and directed. |
| 2 | M & L Sub base 100 mm thick cement concrete type D-2, 1:4:8 (40 mm graded aggregate), complete all as specified and directed. |
| 3 | M&L and fixed in repair machine pressed precast concrete interlocking paver block glossy finish any shape and size confirming to IS 15658 - 2006 of 80 mm thickness, M- 40 grade with grey cement and pigment including 40 mm thick sand cushioning layer, complete all as specified and directed. |
| 4 | M&L and fixed in repair machine pressed precast concrete interlocking paver block glossy finish any shape and size confirming to IS 15658 - 2006 of 60 mm thickness, M- 35 grade with grey cement and pigment including 40 mm thick sand cushioning layer, complete all as specified and directed. |
| 5 | M&L PCC 1:2:4 type B-1 using 20mm graded aggregate as in benching/cooping and sub base set in CM 1:6, complete all as specified and directed. |
| 6 | M&L for 1:3:6 type C-2 (using 40mm graded stone aggregate) as in surface channel and drains and like etc, complete all as specified and directed. |
| 7 | Demolition of brickwork or stone boulders masonry built in CM incl all quins, arches, pillers etc and removing debries out side MOD land, complete all as specified and directed. |
| 8 | M&L for Brick work with Sub class 'B' brick, straight or curved on plan exc 6M mean radius built in CM (1:4), complete all as specified and directed. |
| 9 | Material and labour for rendering 15 mm thick on fair faces of brick wall or stone surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified and directed. |
| 10 | M&L for 75mm thick plain cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) as in plinth protection with out using extra cement & similar work including necessary expansion joint filling with bitumen at a certain distance, complete all as specified and directed. |
| 11 | M&L Preparing old painted brick or conc surfaces of any description not otherwise described over 10 cm width or girth and applying a coat of floor coat emulsion paint, complete all as specified and directed. |
| 12 | M&L Preparing New plaster, brick or conc surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of floor coat emulsion paint over a coat priming paints plaster, complete all as specified and directed. |
| 13 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 14 | S & F of mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders,windows, balcony in ground floor, framed balusters, walk ways, railings, framework of watertanks and similar work conforming to FE-290 Gde -E-165, complete all as specified and directed. |
| 15 | M&L for Preparation of new steel surfaces of any description not otherwise described over 10cm in widht or girth and applying two coats of synthetic enamel paint over red oxide primer, complete all as specified and directed. |
| 16 | Excavation in trenches n. exc 1.50 m wide and n.exc 1.50 m in depth for foundation, drain pipes, sewage lines etc and getting out in soft loose soil, complete all as specified and directed. |
| 17 | Demolition and breaking up drain pipes (SGSW, AC or RCC, CI) of internal dia 75/110 mm, set in cement mortar, complete all as specified and directed. |
| 18 | M & L for 300 mm bore (internal dia of pipe) reinforced concrete pipes, Class NP3 laid in trenches and jointed with CM (1:1) complete all as specified and as directed. |
| 19 | M&L for PCC 1:3:6 type C-2, (using 40 mm graded aggragate) as in concrete bed to 300 mm bore drain pipe including packing under and completely surrounidng pipes with concrete after pipe laid and tested, complete all as specified and directed. |
| 20 | M & L for 450 mm bore (internal dia of pipe) reinforced concrete pipes, Class NP3 laid in trenches and jointed with CM (1:1), complete all as specified and directed. |
| 21 | M & L for PCC 1:3:6 type C-2, (using 40 mm graded aggragate) as in concrete bed to 450 mm bore drain pipe including packing under and completely surrounidng pipes with concrete after pipe laid and tested, complete all as specified and directed. |
| 22 | Returning, filling, including spreading, leveling, watering and well ramming in layers not exc 25 cm, complete all as specified and directed. |
| 23 | Removing excavated (soil) materials and deposited out of MD land.up to a distance of 15 km, complete all as specified and directed. |
| 24 | S&F Factory made precast RCC drain cover of size 900x 600x75 mm or 600x450x50 mm thick and fixed to drain in CM (1:4) and fixed in repair, complete all as specified and directed. |
| 25 | Demolition of RCC of any description and in any position not otherwise specifically provided for including reinforcement cut as required to facilitate demolition and separating scrap and cleaning of reinforcement and removing debris outside MD land, complete all as specified and directed. |
| 26 | M&L for cleaning of open drain or covered drains/culverts including removing & re-covering of RCC/CI/Steel covers by completely removing silt, soil, mud sludge, vegetation growth etc. and removing the same to out side MoD land all as directed by Engr-in-Charge for any width of drains and depth of drains n.exc 0.90m, complete all as specified and directed. |
| 27 | M&L RCC M-20 grade Design Mix (using 20mm graded crushed stone aggregate) as in slab supported on wall, complete all as specified and directed. |
| 28 | M&L MS TMT bars 10 mm dia and over out to length, bent to shape required, including cranking, bending including necessary welding as required & binding with mild steel wire (annealed) not less than 0.90mm dia or securing with clips, complete all as specified and directed. |
| 29 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping, complete all as specified and directed. |
| 30 | Supply & Fixed in repair PVC tensile fabric structure with PVDF (polyvinyl-idene-fluoride) Coating with all necessary fixtures, of any size and shapefor makingcapopies, shade etc fixed with mild steel structural frame work, weight of the fabric is considered, with fabrics ranging from 900 GSM, complete all as specified and directed. Note :- (i) The shape / Design of the shads will be as approved By GE. |
| 31 | S & F in repair for stainless steel letter 450 mm height and 32 mm depth made of 1 mm thick Stainless stell sheet with seamless welding rubed, polished and edges made smooth with necessary fixing devices, complete all as specified and directed. |
| 32 | S & F in repair for stainless steel letter 225 mm height and 32 mm depth made of 1 mm thick Stainless stell sheet with seamless welding rubed, polished and edges made smooth with necessary fixing devices, complete all as specified and directed. |
| 33 | Material and labour fixed in repair for Factory made CI grating drain cover, heavy duty, single seal comforming to Fe-150 IS-210-1978 icluding 2 sets of drain cover lifting and unlocking key to suit each other type drain cover (sample as approved by GE), complete all as specified and directed. |
| 34 | Providing precast RCC jalli & pillars with cement concrete 1:2:4 type B-0 using 12.50 mm graded stone aggregate, thickness of RCC jalli 35 mm (measured solid) including all mouldings & frame, set in cement mortar 1:4 to precast pillars grooves and including reinforcement of 4mm dia annealed wire @ 100 mm c/c spacing on both side alongwith pillars decorative round dome type on top of size 75 x 75 mm with reinforcement 4 mm dia annealed wire 4 Nos with stirrups 4 mm dia @ 150 mm c/c spacing and one number 8 mm dia TMT bar at centre including dismentling of RCC jalli and pillers, complete as approved. |
| 35 | All as per above item No. 34 above but except pillars. |
| 36 | Supply & Fixed in repair Aluminium composite panel sheet 3mm thick PVCF wooden or plain finished fixed with necessary aluminium tube of size 25mm x 38mm x 1.5mm thick with required cilicon & screw as in ceiling/coloumns and in vertical surface complete all as specified and directed and approved sample as kept in GE Office. |
| 37 | M&L in repair for Best quality granite (of any type) 18 to 20 mm mm thick machine cut, beded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing, complete all as specified and directed. |
| 38 | Molding (Sandwitch moulding) of granite slab edges as directed by Engr-in-charge including polishing etc, complete all as specified and directed. |
| 39 | Dismantling, floor hearth or wall tiling inclduing cement mortar bedding and removing rubbish and removing debries out side MOD land, complete all as specified and directed. |
| 40 | M&L for exterior wall tiles as approved by GE thickness of tiles 8 mm area 300 x 600 mm each tiles etc set & jointed in cement and pointed in coloured cement to match the shade of tile and including 10mm thick rendering or backing layer in cement mortar 1:4, complete all as specified and directed. |
| 41 | Material and Labour for first and premium quality of vetrified coloured marble finished digital tiles 1200 mm x 600 mm x 8 to 10 mm thick, in skirting, dados, risers to steps, etc se and jointed in neat cement slurry, and pointed in coloured cement to match tiles over and including 10mm thick rendering or backing layer in cement mortar 1:4, complete all as specified and directed. |
| 42 | Material and Labour for first and premium quality of vetrified coloured marble finished digital tiles 1200 mm x 600 mm x 12 mm to 15mm thick, in floors, etc se and jointed in neat cement slurry, and pointed in coloured cement to match tiles over and including 20mm thick screed bed in cement mortar 1:6, complete all as specified and directed. |
| 43 | Material and Labour for heavy duty outdoor vitrified tiles dark or light shade 10-12 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.16 sqm and not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shed of tiles over and including 20 mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed. |
| 44 | Material & Labour for providing and fixing stainless steel (Grade 304) railing, newal post, ends, caps and balustars etc made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement incl tanking down existing fittings, complete all as specified and directed by Engr in Charge. |
| 45 | M&L for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and and applying two coats of weather proof acrylic exterior paint (100% Acrylic) through authorized applicator only, complete all as specified and directed. |
| 46 | Retroreflective sign board of size 1.20 x 0.60 m both side comprising the following :-(a) Excavation in post holes each not exceedubg 0.50 cum and getting out, returning filling in and ramming earth of broken rubble mixed with earth around in layers not exceeding 25 cm thick watering and removing surplus soil to a distance not exceeding 50 mtrs and making good surface complete. (b) PCC 1:11/2:3 type A-1 using 20 mm graded stone aggregate as in foundation of size 250 x 250 x 450 mm complete. (c) 0.56 mm thick aluminium sheet of size 1.56 m x 0.92 m framed with Stainless steel railing with horizontal and vertical pipe of 32 mm dia on ground in PCC. Height of board from ground level shall be 2.37 m complete.(d) Retroreflective sheeting as prescribed in (c) above on aluminium sheeting both side white or coloured having a smooth outer surface, retroreflective shall be of high intensity grade with encapsulated lence (the message, ledgends, letter, number etc.) and other shall be 100/150 mm size, including taking out old sign board, complete all as specified and directed. Please Enable Macros to View BoQ information |