| 1 | Dismantling of posts or struts (wood, steel or RCC) any section including taking out embeded portion and making good distrubed ground on concrete, brick work, masonry etc and removing of demolished materials out side MD land or any designal place as specified by Engineer-in-charge in the complete Jaisalmer Mil Stn all as specified and directed by Engineer-in-charge. |
| 2 | Dismantling fencing wire mesh, any type complete all as specified and directed by Engineer-in-Charge. |
| 3 | M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified & directed by Engineer-in-charge. |
| 4 | S&F for Galvanised Iron work post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge. |
| 5 | S&F for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality confiorming to round bars Fe-410-W (Gde.E-250) quality A- or Fe 290 (Gde-E-165) complete all as specified and directed by Engineer-in-charge. |
| 6 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long dia of neck 5 to 10 mm complete all as specified and directed by Engineer-in-charge. |
| 7 | Supply only 3.5mm thick PVC Coated chain link fencing mesh with 50mm mesh hole any size or type complete all as specified and directed by Engineer-in-charge.Note :-Fixing only PVC coated chain link fencing, steel round bars for protection will measured and paid separately. |
| 8 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc including provision of binding wire complete as specified & directed by Engineer-in-charge. Note :-Supply only chain link fencing will measured and paid separately. |
| 9 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed by Engineer-in-charge. |
| 10 | M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge. |
| 11 | M & L for preparation of new or previously untreated surfaces including two coat of synthetic enamel (ordinary tint) paint over priming with red oxide, zinc of any description, not exc 10cm in width or girth, not otherwise described complete all as specified and directed by Engineer-in-charge. |
| 12 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) including removing of debries out side MoD land complete all as specified and directed by Engineer-in-charge. |
| 13 | M&L for 75 mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing path & finishing the surface even & fair without using extra cement all as specified & directed. |
| 14 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-25 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or heavy traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by engineer-in-charge.Note: No payment shall be released if plate vibratory is not utilised for compaction. |
| 15 | Material & Labour for ceramic out door tiles 400mmx400mmx10-11mmm thick digital design set, heavy duty, jointed and pointed in neat cement slurry as in floors with grey cement over & including over screed bed or bedding layer of mortar 20 mm thick Cement Mortar 1:6 complete all as specified & directed by Engineer-in-charge. Note : Work will be in patches or in bulk |
| 16 | M&L plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) cast in situ kerb stone, copings, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straigth or curved) and setting in CM (1:4) complete all as specified and directed by Engineer-in-charge. |
| 17 | M&L for 50mm thick PCC (1:2:4) type B0 (using 12.50mm graded stone aggregate) as in sub base of floors & finishing the cement concrete surface even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge. |
| 18 | S&F Glass dividing strips 3mm thick, width 22 mm complete all as specified and directed by Engineer-in-charge. |
| 19 | Demolition of brick work or stone/ boulder masonery built in cement mortar including all quoins arches, pillers including coping etc all as specified and directed by Engineer-in-charge. |
| 20 | M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) including Extra over stone walling for hammer dressing to face stones with maximum depression on face from straight edge not exc 20mm and dressing face beds and joints as specified to squared rubble walling, Jodhpur type brought upto courses etc complete all as specified and directed by Engineer-in-Charge. |
| 21 | Taking down cement plaster in cement or cement lime mortar on brick or concrete walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MoD land complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |
| 22 | Taking down cement plaster in cement or cement lime mortar on brick or concrete walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MoD land complete all as specified and directed by Engineer-in-charge. Please Enable Macros to View BoQ information |