| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair/Maintenance of high mast lights, street lights, LT cables, garden lights and other misc works in the area of Golf view enclave, 4 Para, 4/3 GR and other locations under GE (Utilities) Udhampur. Contract No: GE/U-10/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Dismantling the flood light, cable, connector, ring and other assembly from 9 to 12 mtr mini hight mast of any type, size and situated any type of location by applying crane /hydra and refixing the complete items/ assembly on 16 mtr top after repairing of light any type/wattage incl complete dismantling, checking replacement of unserviceable parts and components as required and make the light fittings operational to give rated illumination incl cleaning the acrylic/glass cover and refixing the same after repair/replacement of spare components complete with necessary electrical connection complete all as specified and directed by Engineer-in-Charge.Note :- 1. Spare parts/components shall be measured and paid separately under respective item of sch 'A' . |
| 3 | Dismantling and taking down the complete high mast tower 15 to 20 mtr height by removing bolts and nuts at the bottom with the help of crane/motor and removing the worn out /cut stainless steel GI wire unservicable pulley,shafts checknuts etc including fixing new spares,applying grease, checking and rectifying mechanical and electrical connections and re-erecting the same after making functional of all components complete all as specified and directed by Engineer-in-Charge.Note:(i) Necessary Spares shall be measured and paid separately under relevant item/items of the schedule. The rate for minor spares necessary for carryingout the repair work which are all not covered under the schedule shall also deemed to be included the quoted rate.(ii) The rate quoted deemed to be included the rate of all manpower including technicians, crane operator etc. and all tools and plants including crane/motor required to carryout above work.(iii) The light assembly shall also be checked twice in the contract period other than the repairing time by taking down the light assembly from top to bottom and taking up to the original position (i.e. from bottom to top) after completing the repair work if any including checking the serviceability of high mast operating mechanism.(iv) The greasing of pully, roller, bearing and gear including refixing rope clamp, adjustment of lock, lever etc deemed to be included in the item rate. |
| 4 | Supply and fixing trailing cable 4 Sqmm, 5 core copper conductor EPR insulated PCP sheathed cable having current carrying capacity 30 Amp complete all as specified and directed by Engineer-in-Charge. |
| 5 | Supply and fixing trailing cable connector and terminal box suitable for 16 Mtr high mast. Make and model as per existing, complete all as specified and directed by Engineer-in-Charge. |
| 6 | M & L for removing the motor of capacity 2 hp to 5 hp from high mast light, rewinding the same with supper enamelled copper wire as per existing gauge and varnishing complete with “E” class varnish, including replacement of gun metal bush and side rubber ring and re-fixing in original position complete including testing complete all as specified and directed by Engineer-in-Charge. |
| 7 | M&L in replacement of Chain system suitable for running in pinion at site of individual high mast pole complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply and fix in repair reverse forward switch suitable for existing high mast light tower 15 mtr to 20 Mtr height including taking down old and unserviceable R/F switch etc complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply and fix galvanised steel wire rope 8 mm dia 30 mtr long suitable for existing high mast light tower 15 mtr to 20 Mtr height including taking down old rope complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply and fix galvanised steel wire rope multistranded suitable for high mast not less than 10 mm dia 30 mtr long suitable for existing high mast light tower 15 mtr to 20 Mtr height including taking down old rope complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply and fix in repair pulley for geared motor after removing old and unserviceable pulley including applying grease and gear oil for making the high mast functional complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply and fix in repair sprocket for geared motor including taking down the old and unserviceable sprocket complete all as specified and directed by Engineer-in-Charge. |
| 13 | S&F of Steel tubular swaged Ring suitable for 12 m long pole for semi highmast light and for fixing of four nos flood loghts with bolts, nuts and screws, ring made out of ERW MS tubing conforming to IS-2713 including drilling of holes of required size for fixing of brackets , painting the exposed surfaces of ring with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of silver paint on the surface complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply and fixing street light Lexic Power Timer contactor, 04 pole, 63 Amps complete all as specified and directed by Engineer-in-Charge. |
| 15 | Labour only for cutting/pruning the overhanging or adjacent branches of trees of any girth LT street light pole including cutting the branches of tree and cleaning the jungle below and upto 4.00 metre clear distance from the street light fitting on the pole on either side complete and removing rubbishes from site complete all as specified and directed by Engineer-in-Charge. |
| 16 | S&F 4 Sqmm single core stranded PVC insulated copper conductor FRLS cable for connection of fittings, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and pour gear box oil suitable for geared motor after cleanig all geared surface of high mast gear box including draining out of old unusable oil complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply and fix in repairs bollts,nuts,washers, check nuts etc.suitable for high mast light complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply and fix in repairs aviation obstruction light LED comprising aluminium housing with poly carbonate enclosure, 302 members LED are provided complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply and fix in repair energy saving rectangular LED flood light fitting 250 Watts, 240 volts AC, cool white colour, CCT 5700°K, CRI>70, THD<10%, system lumens not less than 120 lumens/watt with innovative thermal management, available with multiple optics, equipped with IP-66 protection, 5 KV surge protection, 120 Lm/watt aluminium die cast housing with toughened glass visor, life of luminaires should not be less than 50000 burning hours and suitable for large area lighting including fixing on High mast pole/Buildings/TARMAC poles etc. by means of clamps, nuts, bolts and any other accessories complete all as specified and directed by Engineer-in-Charge.Make-Bajaj Cat Part No. PRAZE F 300L WH NB-A5 TG SD or equivalent from the list of make given in particular sepecifivation |
| 21 | Painting to mini high mast steel tubular pole includin ring of height 9 to 12 metre long at surface of any description over 10 CM grith or width ,not otherwise described,prepare old or new untreated surface,old painted surfaces including priming cement based paints plaster with synthetic enambled paint coat and plastic emulsion coat over surface with two coats of aluminium paint including brackets, clamps, nuts bolts, washer etc complete all as specified and directed by Engineer-in-Charge.. |
| 22 | Scrapping , cleaning and preparation of old surfaces of steel tubular pole of any type. size , height, swan neck type (9 mtr long) steel fitting including brackets, clamps, nuts bolts, washer etc complete and M&L for painting with two coat for aluminium paint after preparation of the steel surfaces complete all as specified and directed by Engineer-in-Charge. |
| 23 | Mateial and labour for applied strap with two coats black and white paint in strap alternatevely all round the poles from the bottom of the pole for indication of the poles. Height of the strap shall be 30 cm and number of strap shall be 05 Nos complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material and labour for writing pole No with sub stn No on pole with applied two coat of black paint and writing the pole No and Sub Stn No with white luminaire paint of letter size 75 mm complete all as specified and directed by Engineer-in-Charge. |
| 25 | Taking down unserviceable street/Security light fittings of any capacity, type , make and position (such as CFL light fitting, HPSV/MH/LED and from any tye and any height of pole etc) for repairing the same after complete dismantling, checking replacement of unserviceable parts and components as required and make the light fittings operational to give rated illumination incl cleaning the acrylic cover and refixing the same with necessary electrical connection complete all as specified and directed. (The U/S street light fittings should be removed from site and to be stored at one place for repairing purpose. The Nos of U/S light fittings to be removed, the place of repairing and refixing schedule complete all as specified and directed by Engineer-in-Charge.) Note :- (Spare parts/components shall be measured and paid separately) under respective item Sch 'A'). |
| 26 | S&F in replacement of driver for LED light fitting of capacity 60W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F in replacement of driver for LED light fitting of capacity 60W to 90W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge.as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F in replacement of driver for LED light fitting of capacity 120W to 150W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 29 | S&F in replacement of driver for LED light fitting of capacity 210W to 300W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F in replacement of driver for LED light fitting of capacity 40 to 45W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 31 | S&F in replacement of panel for LED light fitting of capacity 60W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. Make : as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 32 | S&F in replacement of panel for LED light fitting of capacity 60W to 90W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F in replacement of Panel for LED light fitting of capacity 120W to 150W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 34 | S&F in replacement of panel for LED light fitting of capacity 210W to 300W for any make fitting as per matching to existing type including necessary connection complete all as specified and directed by Engineer-in-Charge. as per existing make and model complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and fixing in replacement MS clamp any shape and size along with nuts, bolts and washers etc of sizes as required, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Terminal box made out of SMC with hinged door and locking arrangements of size 140x140x95mm (in repair) including Backlite 4 way connector,M.S. Clamps suitable for pole ,PCC/MS/GI/rail etc. with bolt, nut and washer ,electrical connections including MCB SP 6-32 Amps complete all as specified and directed by Engineer-in-Charge.Make - Sintex product code No GSJB-1414 orr equivalent from the list of make given in particular sepecification |
| 37 | Supply and fixing non transparent looping SMC kiosks pole box 3 phase of size 310×210×120 mm made out of engineering plastic one piece moulding siemens gray colour with hold fast including 4 Nos aluminium strips 60 amp of requird size fixed on unbrakable insulator and one no single pole MCB 1 to 3 amp 'C' curve including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. |
| 38 | Replacement of old unserviceable rusted GI tubing brackets, 40mm bore, light grade with new GI tubing bracket, 40mm bore, light grade, 1.20 metre length ,made to shape including MS clamp with nuts, bolts and washers etc complete all as specified and directed by Engineer-in-Charge. |
| 39 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cables, foundation of poles, stays and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge. |
| 40 | Excavation in trenches exc. 1.50 metre depth and not exc. 3.00 metre deep.for laying of underground cable, erection of poles etc. and getting out in soft/loose soil including separating serviceable bricks for re-use at site obtained during excavation complete all as specified and directed by Engineer-in-Charge. |
| 41 | Returning , filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge. |
| 42 | Removing of excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 43 | Taking out UNSV two core/three core aluminium / copper cable of any sizes/ capacity complete all as specified and directed by Engineer-in-Charge. |
| 44 | S & F PVC insulated and sheathed 1.5 sqmm, two core, multi stranded, copper conductor cable from junction box/OH line to street light fitting or for engagement lights complete all as specified and directed by Engineer-in-Charge. |
| 45 | PVC insulated multi stranded aluminum conductor PVC cable sheathed 10 Sqmm twin core (in replacement) and making connections of street light fittings with overhead lines/UG Cable complete all as specified and directed by Engineer-in-Charge. |
| 46 | PVC insulated multi stranded aluminum conductor PVC cable sheathed 6 Sqmm twin core (in replacement) and making connections of street light fittings with overhead lines/UG Cable complete all as specified and directed by Engineer-in-Charge. |
| 47 | PVC insulated multi stranded aluminum conductor PVC cable sheathed 4 Sqmm twin core (in replacement) and making connections of street light fittings with overhead lines/UG Cable complete all as specified and directed by Engineer-in-Charge. |
| 48 | Taking out UNSV XLPE UG cable of any sizes/ capacity from LT panel, junction box, pole, wall, under pcc and trench including disconnection/connection of necessary electrical connection complete and make good the disturbed surface to the existing surface complete all as specified and directed by Engineer-in-Charge. |
| 49 | XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 16 sqmm, 4 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engineer-in-Charge. |
| 50 | XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 16 sqmm, 2 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engineer-in-Charge. |
| 51 | XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 10 sqmm, 2 core, laid in trenches/ducts/through pipe complete all as specified and directed by Engineer-in-Charge. |
| 52 | Double walled corrugated pipe (DWC) of size 50 mm conforming to IS14930 (Pt-II:200)/IS16205 Pt-I 2017,IS-16205 Pt-24 : 2018 with necessary snap fit coupler complete all as specified and directed by Engineer-in-Charge. |
| 53 | S & F LED flood light, 200 watt, with lens , 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engineer-in-Charge.Make- Bajaj Cat No GLEAMF220LWHSYPCSDV2 or equivalent from the list of make given in particular sepecifivation |
| 54 | S & F LED flood light, 150 watt, with lens , 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engineer-in-Charge.Make- Bajaj Cat No GLEAMF220LWHSYPCSDV2 or equivalent from the list of make given in particular sepecifivation |
| 55 | S & F LED flood light, 120 watt, with lens 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engineer-in-Charge.Make :-Bajaj Cat No PRAZEF144LWHNB-ASTGSDMTor equivalent from the list of make given in particular sepecifivationNote: For item Serial no 18.00 to 27.00(a) MS clamp,Brackets required for fixing of fitting are inclusive of rate quoted.(b) Necessary grouting/making good on existing surfaces in inclusive of rate quoted.(c) GI pipe of required dimensions if required at site shall be provided by the contractor. |
| 56 | S & F LED flood light,80 wat, with lens 230 V, AC outdoor type with thermal management in multiple optics, powder coated, pressure die cast aluminium body with toughened glass visor, and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,CCT 5700K, lumen efficacy not less than 110 lumen/watts (in repair) complete all as specified and directed by Engineer-in-Charge.Make :- Bajaj Cat NoGLEAMF88LWHSYPCSDV2 80W or equivalent from the list of make given in particular sepecifivationNote: For item Serial no16.00 to 26.00(a) MS clamp,Brackets required for fixing of fitting are inclusive of rate quoted.(b) Necessary grouting/making good on existing surfaces in inclusive of rate quoted.(c) GI pipe of required dimensions if required at site shall be provided by the contractor. |
| 57 | S&F LED street light fitting withlens , 90 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engr-in-Charge.Note :- Necessary fixing authority including reducers may be included in rateMake-Bajaj Cat No ZELA P 108L WH PO TG SD or equivalent from the list of make given in particular sepecification |
| 58 | LED street light fitting with lens 70/72 Watt , 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection,Touhned glass, CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engineer-in-Charge.Note :- Necessary fixing authority including reducers may be included in rateMake :- Bajaj Cat No ZELA P 86L WH PO TG SD or equivalent from the list of make given in particular sepecifivation |
| 59 | LED street light fitting with lens , 60 Watt , 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection, Touhned glass,CCT 5700K, lumen efficacy not less than 110 lumen/watts complete all as specified and directed by Engineer-in-Charge.Note :- Necessary fixing authority including reducers may be included in rateMake:- Bajaj Cat No ZELA P 72 L WH PO TG SD or equivalent from the list of make given in particular sepecifivation |
| 60 | Post top lantern, LED Warm white , type 40 watt , 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant (in repair) complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP-66 protection complete all as specified and directed by Engineer-in-Charge.Make:- Bajaj cat No BGCTNP40WLED WW or equivalent from the list of make given in particular sepecifivation |
| 61 | LED bollard Warm white lights of 9/11 watt capacity including taking down existing unserviceable garden lights of any type/capacity complete all as specified and directed by Engineer-in-Charge.Make:Bajaj Cat No BGBOL605 9W LED WW or equivalent from the list of make given in particular sepecifivation |
| 62 | LED lamp warm white/white 9 Watt (in replacement) complete all as specified and directed by Engineer-in-Charge. |
| 63 | LED lamp warm white/white 7 Watt (in replacement) complete all as specified and directed by Engineer-in-Charge. |
| 64 | MCB TPN -63 Amp, 230V, 50Hz,10 KA (in replacement) complete all as specified and directed by Engineer-in-Charge. |
| 65 | MCB SPN -40 Amp, 230V, 50Hz, 10 KA (in replacement) complete all as specified and directed by Engineer-in-Charge. |
| 66 | MCB SP-10 Amp, 230V, 50Hz, 10 KA, (in replacement) complete all as specified and directed by Engineer-in-Charge. |
| 67 | Supply and fixing SPN, DBs for lexic MCB complete with SPN MCB 40 Amp, 10 KA, 240 V fixing on pole with necessary clamp and nut, bolts complete all as specified and directed by Engineer-in-Charge. |
| 68 | S &F LED Tiranga Rop light 18 Mtr,IP 65,Input Power 10W/meter,Input Voltage 220-240 VAC Input frequency 50 Hzs,Input current 0.045 Amp/Mtr,Power factor 0.95,Width of strip(+/- 0.1 mm) 8 mm length/reel-18 mtrs,No of led per mtr 120 LED,LED Beam angle 120 degree ,Rope light per Colours length 6 mtr orange, 6 mtr white ,6 mtr Green,Fixing method silicone clip ,Ingrass Protection -IP -65, Ingrass protection method silicone tube ,silicone tube dimention 11.5x5.5 mm+/- 0.5 mm,working temp range-20 degree celcius to + 45 degree celcious ,working humidity range 10-90 RH complete all as specified and directed by Engineer-in-Charge. |
| 69 | S &F Joy LED Strings light 10 Mtr,21D IP 44, Input Voltage 220-240 VAC Input frequency 50 Hzs,Input current 0.045 Amp/Mtr,Power factor ss Protection -IP -44, ,working temp range-20 degree celcius to + 45 degree celcious ,working humidity range 10-90 RH and all as directed by engineer in charge . |
| 70 | S&F single colour warm white LED flexible strip light of 25mtr length with driver, IP20 complete with accessories including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 71 | S&F single colour warm white LED flexible strip light of 50mtr length with driver, IP20 complete with accessories including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 72 | Supply & Fixing in replacement of controlling unit (sensor) in existing Automatic Street Light Control Panel using infrared sensor based Nature Switch . Nature switch operation should be based on Natural Light Lux* level. Required illuminance Level for switching on is < 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max 8 or 12 hours including necessary electriical connection complete with thimble and pvc tape complete all as specified and directed by Engineer-in-Charge.Make:- Nature switch or equivalent from the list of make given in particular sepecifivation |
| 73 | Attending day to day complain of street light/perimeter ligts, high mast lights, flood lights, gate lighrs, garden lights, post of lantern lights, ornamental lights, decorative lights of any type, size, make, model, capacity and any condition from any height of steel tubular pole, mini high mast pole, High mast pole, buildings including disconnection of electrical connection from timer panel, MCB, and street light pole for checking the loose connecton and decarbanising between coper and alluminium conductor and reconnection of the same after checking the servicibility of electric supplly from Timer Panel to Juncion box, pole and upto LED lights fittings of any type complete with PVC tape, proper insulation and tide the wire on pole complete all as specified and directed by Engineer-in-Charge. Note : The contractor has to attend daily minimum 5 to 10 complain of no lights in street lights connection due to carbon, loose connection, disconnection of cable due to monkey nuisance, heavy wind flow and rain effects on electrical circuit. To attend 5 to 10 complain daily. Note : (i) Contractor should organise his staff strength in such a manner that One electrican and Two Helper shall be provided with sutable vehicle by the contractor for attending street light electrical connection unserviceability complaints at different location in the AOR of AGE E/S and all as directed . All the precautionary equipment like safety belt, earth road, hand gloves, ladder, and T&P shall be provided by the contractor. (ii) If he fails to attend the complain daily the penalty of Rs. 2000 per complain per day will be charged and deducted from the next due RAR. |
| 74 | Dismantling of unserviceable concerete/steel tubular pole any size upto 9 mtr long including breaking up PCC and making good disturbed surface and removing materials from site of work complete all as specified and directed by Engineer-in-Charge. |
| 75 | Supply and erecting steel tubular swaged poles erected to truly vertical or planted as strut complete with 6mm thick mild steel base plate(300mmx300mm), welded to pole, finial taper plug, bolts, nuts, and screws. Poles made out of ERW MS tubing conforming to IS-2713 Part-II Type 410 SP-37, 9 mtr long including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bitumenous paint internally and portion embedded in concrete, making five black & white bands at lower portion of pole each 300mm wide alternately upto the height of 1.5 m and marking pole No. with black paint at suitable height including making two nos holes of suitable size in steel tubular pole by gas welding for passing PVC cable connection from junction box to security lights through pole where junction box to be fitted in pole complete all as specified and directed by Engineer-in-Charge. Note: - Excavation, Earth Work and PCC in foundation shall be measured and paid for separately. |
| 76 | Plain cement concrete M- 7.5, (1:4:8), type D-2 (using 40mm graded crushed stone aggregates) as in foundation complete all as specified and directed by Engineer-in-Charge. |
| 77 | Plain cement concrete, M-15, type B-0 (using 12.5 mm graded crushed stone aggregates) as in coping complete all as specified and directed by Engineer-in-Charge. |
| 78 | Note for item No 19.00, 52.00, 53.00, 54.00, 55.00, 56.00, 57.00, 58.00, 59.00, 60.00 & 67.00:- All LED/Street lights shall be embossed from the company/Contractor by GE (U) Udhampur and CA No. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |