| 1 | Demolition of reinforced cement concrete of any description and in any position no otherwise specifically provided for as in cover slabs (for man holes, septic tank, soak well etc) complete all as specified and as directed by Engineer-in-charge. |
| 2 | M&L for providing precast cement concrete in landings,cover slabs (for man holes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces type B1 1:2:4 using 20mm graded stone aggregate set in cement mortar 1:4 complete all as specified and as directed by Engineer-In-Charge. |
| 3 | MS bars (TMT) 8mm dia and over cut to length bent to shape reqd incl cranking binding spirally for hooking for cols and binding with and inc mild steel wire (Annealed) not less than 0.9mm dia as in reinforcement complete all as specified and as directed by Engineer-in-charge. |
| 4 | Demolition of cement concrete in ground floor and pavings nexc 15cm thickness (below or above ground level), complete all as specified and as directed by Engineer-in-charge. |
| 5 | M&L 25mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in levelling course complete all as specified and directed by Engineer-in-charge. |
| 6 | M&L non skid cermic coloured tiles 8mm thick ( square or rectangular) area of each tile exceeding 0.6 sqm but not exceeding 0.11sqm, in floor etc and jointed in neat cement slurry and pointed in white cement or coloured cement to match the shade of tile over and including 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed by Engineer-in-charge. |
| 7 | M&L for Vitrified Dark Shade/Designer Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:4 complete all as specified and as directed by Engineer-in-charge. |
| 8 | M&L for Vitrified Dark Shade/Designer Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 0.1 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 15mm thick screed bed in CM 1:4 complete all as specified and as directed by Engineer-in-charge. |
| 9 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-in-charge. |
| 10 | S&F glazed ceramic coloured tiles in vertical surfaces such as skirting, dado etc 350 x 250 x 7mm/ 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match incl cutting to reqd shape and size over and including 10mm thick plaster in CM (1:4) on vertical surfaces as backing coat complete all as specified and as directed by Engineer-in-charge. |
| 11 | M&L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded aggr) as in path/hard standing/ plinth protection cement all as specified and as directed by Engineer-in-charge. |
| 12 | Taking down chowkats or frames with shutters w/o taking off shutters from the frames n.exc 1.5 Sqm each,complete all as specified and as directed by Engineer-in-charge. |
| 13 | Taking down chowkats or frames with shutters) w/o taking off shutters from the frames exc 1.5 Sqm and n.exc 4.0 sqm each each, complete all as specified and as directed by Engineer-in-charge. |
| 14 | Taking down shutter of any description n. exc 1.00 Sqm each complete all as specified and as directed by Engineer-in-charge. |
| 15 | Taking down shutter of any description exc 1.00 Sqm and not exc 2.00 sqm each , complete all as specified and as directed. |
| 16 | Refixing shutter in same opening any description exc 1.00 Sqm and n.exc 2.0 Sqm each complete all as specified and as directed by Engineer-in-charge. |
| 17 | Taking down and refixing of aluminium doors shutters of area n exc 4sqm including new SS hinges, riveting, rubber beadings, locking arrangement, door stopper, alignment of doors frame styles and rails including required fasteners long screw to make shutter in serviceable condition and making good to existing surface complete all as specified and as directed by Engineer-in-charge. |
| 18 | Taking down and refixing of aluminium window shutters sliding/ casement of area n exc 2sqm including new SS hinges, riveting, rubber beadings, locking arrangement, alignment of window frame styles and rails including required fasteners long screw to make window in serviceable condition and making good to existing surface complete all as specified and as directed by Engineer-in-charge. |
| 19 | S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with M.S. square tube and fixing in opening as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge. |
| 20 | S&F factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site complete all as specified and as directed by Engineer-in-charge. |
| 21 | S &F power coated Anodised aluminium frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-charge. |
| 22 | S &F for Powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed by Engineer-in-charge. |
| 23 | S &F of powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, locking arrangement etc. complete all as specified and as directed by Engineer-in-charge. |
| 24 | S&F powder coated Anodised aluminium grill (anodised transparent or dyed to requiredshade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill toproper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 25 | S&F framed work such as grills, gratings etc. with ends of bars shouldered and or rebated or forged into spikes, framed guard bars etc confirming to Fe-290-Gde-E-165 complete all as specified and as directed by Engineer-in-charge. |
| 26 | Polyrethane flooring : 4mm thick PU floor ( thickness will vary per requirement) in repair(a) Surface preparation : Providing and roughening the smooth surface to provide the mechanical key for subsequent application, grinding all sharp edges to make them flush with the surface, making groove of 8mm x 8mm in size at approximately 100mm away parallel from wall and adjacent to doorway, covering not more than 20Smtr, cleaning the all floor area to make it free from all dirt, dust and other contaminants, etc and complete as per manufacturer's specifications.(b) Scratch Coat :- Providing and installing Apcoflor PU Screed at 1mm thick as scratch coat using flat trowel by mixing all 3 components and colour pigment in mixing vessel using heavy duty slow speed drilling machine fixed with mixing Paddle, etc and complete as per manufacturer's specifiecation.(c) Top Coat : Supply and apply of Apcoflor PU screed Polyurethane floor Topping on concrete floor. The floor concrete should be prepared with scarification or captive shot blasting process. The dust and debris to be removed by Industrial Vacuum Cleaner. Anchor Grooves to be cut of size 1.5 to 2 times the thickness of the floor topping. Along the perimeter of floor topping, around columns, open drains, slong construction joints, cable trenches, etc, Open up all the cracks in to anchor grooves. Fill all the anchor grooves with Apcoflor PU screed material. Provide a scratch coat of Apcoflor PU screed @ 2 to 2.25 Kg per Sqm with groove filling, allowing to cure over night. Complete the topping with Apcoflor PU Screed @ 2Kg per Sqm/mm. Allow to cure for the necessary period as per Manufacturers instructions.Note :- The following shall comply to the following technical parameters :(i) Compressive Strength (ASTM C 579) 38+/-5% MPa(ii) Flexural Strength (ASTM C 580) 12+/-5% MPa(iii) Tensile Strength (ASTM C 307) 5.5+/-5% MPa(iv) Abrasion Resistance, (ASTM D 4060) 120 mg loss per 1000 cycles (1 KG load using CS 17 wheels. (v) Pull up Adhesion on concrete (ASTM D 4541) > 1.5 MPa, Concrete failure (vi) Shore D Hardness, 24 hours (ASTM D 2240) 80(vii) Surace Resistivity (ANSI/ESD 2020) 2.5x10^11 ohms |
| 27 | M&L for preparation of new or previously untreated steel surfaces over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide complete all as specified and as directed by Engineer-in-charge. |
| 28 | S&F in repairs aluminium Mortice lock, vertical type, size 75 mm 4 Levels complete all as specified and directed by Engineer-in-charge. |
| 29 | S&F for ACP boards in 4.00 mm thickness as in panel of door shutters/partition wall including AC beading etc complete all as specified and as directed. |
| 30 | S&F in 5.5mm thick plain glass, ordinary quality and glazing with oil putty/aluminium glazing clips in squares n.exc 0.5 Sqm in each panel complete all as specified and as directed. |
| 31 | All as per item No 30 (here-in-before) but exc 0.5 Sqm in each panel 5.5 mm thick sheet glass complete all as specified and as directed by Engineer-in-charge. |
| 32 | S & F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed by the Engineer-in-Charge |
| 33 | S & F in repair galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed by the Engineer-in-Charge. |
| 34 | S &F stainless steel butt hinges 100mm size medium weight, complewte all as specified and as directed by Engineer-in-charge. |
| 35 | S&F for 100mm long anodised aluminium barrel tower bolt of extruded section complete all as specified and as directed |
| 36 | S & F 150mm long anodised aluminium handles, cast type, complete all as specified and as directed. |
| 37 | S&F 300MM long aluminium anodised sliding door bolt with hasp staple (bolt type) and fixing clups of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy and fixed, complete all as specified and as directed by the Engineer-in-Charge. |
| 38 | S&F, Aluminium(Die cast)body Door closer hydraulically regulated,designation No3,universal type,suitable for shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified & as directed. |
| 39 | S&F in repairs and fixed Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty floor spring for aluminum/glass door shutter of required size and making good to surface complete all as specified and as directed. |
| 40 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets complete all as specified and as directed by Engineer-in-charge. |
| 41 | S&F in repair 4mm thick (Non asbestos fibre cement building board), size 600mm x 600mm HPSC (High pressure steam cured) prelamainated self embosed, textured disigner board E classic board fixed or laid/inserted to timber/GI/Aluminium frame work with screws in ceilling flat or sloping complete all as specified and as directed. |
| 42 | S&F in repair 12mm thick size 600mm x 600mm perforated Gypsum Board textured disignerfixed or laid/inserted to timber/GI/Aluminium frame work with screws in ceilling flat or sloping complete all as specified and as directed. |
| 43 | Supply and fix false ceiling work of galvanised iron powder coated frame work of size 28x24x0.9mm thick angle, snap grid size (605mm X 605mm) frame work with Hangers 6mm dia. GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and including necessary bolts, nuts and washers for false ceiling with and including 12mm thick of size 600mm x 600mm perforated Gypsum Board textured designer as in ceiling tile fixed or laid/ inserted to framework complete all as specified and as directed by Engr-in -Charge. |
| 44 | Supply and fix false ceiling work of galvanised iron powder coated frame work of size 28x24x0.9mm thick angle, snap grid size (605mm X 605mm) frame work with Hangers 6mm dia. GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and including necessary bolts, nuts and washers for false ceiling with and including 4mm thick of size 600mm x 600mm HPSC (High pressure steam cured) prelaminated self embosed, textured designer board E classic board as in ceiling tile fixed or laid/ inserted to framework complete all as specified and as directed. |
| 45 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 46 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour and design having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or 'J' / 'L' hooks complete all as specified and as directed. |
| 47 | Same as in item No. 46 but plain sheet as in ridges, gutters , facia etc complete all as specified and as directed. |
| 48 | M&L for coloured glossy finish Chequered cement concrete tiles 20cm x 20cm x 25mm thick, With white cement & pigment set, jointed and pointed in neat cement slurry and painted in white or coloured cement in floors incl 15mm thick screed bed in CM (1:6) complete all as specified and as directed |
| 49 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive way or light traffic, parking etc of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping etra and complete all as specified and as directed. |
| 50 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate ) as in kerb / coping including necessary form work etc complete all as specified and as directed. |
| 51 | M&L for 75 mm thick PCC 1:3:6 type D2 (using 40mm graded stone aggregate) as in Sub base for path/hard standing ,complete all as specified and as directed. Please Enable Macros to View BoQ information |