| 1 | Excavation in trenches by mechnical means (hydraulic excavator) not exceeding 1.5m wide and not exceeding 1.5 m in depth and getting out all kind of soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, leveling watering and well ramming in layers of soil not exceeding 25cm. |
| 3 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point of rock. |
| 4 | Taking up or down steel tubing and connections, including cleaning for refixing or removal to store or staking at site of size 15 mm dia. |
| 5 | All as per item No 4 above ……….. But for 20 mm dia |
| 6 | All as per item No 4 above ……….. But for 25 mm dia |
| 7 | All as per item No 4 above ……….. But for 40 mm dia |
| 8 | All as per item No 4 above ……….. But for 50 mm dia |
| 9 | All as per item No 4 above ……….. But for 80 mm dia |
| 10 | All as per item No 4 above ……….. But for 100 mm dia |
| 11 | Refixing/laying old steel tubing and connections of 15 mm dia in new or old positons (wall/ ceiling, floor, intrenches etc) threading, rethreading and with necessary fittings all as directed. |
| 12 | All as per item No 11 above ……….. But for 20 mm dia |
| 13 | All as per item No 11 above ……….. But for 25 mm dia |
| 14 | All as per item No 11 above ……….. But for 40 mm dia |
| 15 | All as per item No 11 above ……….. But for 50 mm dia |
| 16 | All as per item No 11 above ……….. But for 80 mm dia |
| 17 | All as per item No 11 above ……….. But for 100 mm dia |
| 18 | Supply and fixing/laying in trenches steel tube medium grade with all fitting and fixed complete to wall, tubing and ceilings or laid in floor/ trench of size 15 mm dia |
| 19 | All as per item No 18 above ……….. But for 20 mm dia |
| 20 | All as per item No 18 above ……….. But for 25 mm dia |
| 21 | All as per item No 18 above ……….. But for 40 mm dia |
| 22 | All as per item No 18 above ……….. But for 50 mm dia |
| 23 | All as per item No 18 above ……….. But for 80 mm dia |
| 24 | All as per item No 18 above ……….. But for 100 mm dia |
| 25 | Supply and fixing in replacement of gunmetal gate valve with iron wheel screwed both ends for iron pipe and fixed of size 15 mm dia. |
| 26 | All as per item No 25 above ……….. But for 20 mm bore |
| 27 | All as per item No 25 above ……….. But for 25 mm bore |
| 28 | All as per item No 25 above ……….. But for 40 mm bore |
| 29 | All as per item No 25 above ……….. But for 50 mm bore |
| 30 | M&L for CI/DI special/fittings suitable for CI/DI flanged/socket ends pipe upto 80 to 150 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint, etc. complete all as specified and as directed, |
| 31 | M&L for CI/DI special/fittings suitable for CI/DI flanged/socket ends pipe upto 200 to 300 mm bore dia such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junction, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers etc. complete all as specified and as directed. |
| 32 | Taking up old U/S steel hume pipe line/CI/GI/DI any type water mains pipes, any class,(including all fittings) of size 80 mm bore disconnecting pipes and fittings complete |
| 33 | All as per item No 32 above ……….. But for 100mm bore |
| 34 | All as per item No 32 above ……….. But for 150 mm bore |
| 35 | All as per item No 32 above ……….. But for 200mm bore |
| 36 | All as per item No 32 above ……….. But for 300mm bore |
| 37 | Relaying only old pipe DI/CI/GI in good condition/pipe taken out from trenches for repairs in any length including fittings etc. of size 80 mm bore |
| 38 | All as per item No 37 above ……….. But for 100mm bore |
| 39 | All as per item No 37 above ……….. But for 150mm bore |
| 40 | All as per item No 37 above ……….. But for 200mm bore |
| 41 | All as per item No 37 above ……….. But for 300mm bore |
| 42 | Supply and fix cast iron pipes with spigot and socket ends centrifugally casted class LA in any length suitable for rubber tytan joint and Laid in trenches of size 80mm bore. |
| 43 | All as per item No 42 above ……….. But for 100mm bore |
| 44 | All as per item No 42 above ……….. But for 150mm bore |
| 45 | All as per item No 42 above ……….. But for 200 bore |
| 46 | All as per item No 42 above ……….. But for 300 bore |
| 47 | Supply and laying in trenches/surfaces 200mm bore Ductile iron spigot and socket pipes as per IS:8329/2000 class K7 including EPDM rubber gasket suitable for and including push on rubber gasket joint with inside cement mortar lining and outside zinc bitumen coating complete all as specified and as directed. |
| 48 | Supply and laying in trenches/surfaces 150mm bore Ductile iron spigot and socket pipes as per IS:8329/2000 class K7 including EPDM rubber gasket suitable for and including push on rubber gasket joint with inside cement mortar lining and outside zinc bitumen coating complete all as specified and as directed. |
| 49 | Supply and laying in trenches/surfaces 100mm bore Ductile iron spigot and socket pipes as per IS:8329/2000 class K7 including EPDM rubber gasket suitable for and including push on rubber gasket joint with inside cement mortar lining and outside zinc bitumen coating complete all as specified and as directed. |
| 50 | M&L for burning out lead joint in position , including removing lead to store / stacked at site to issue under credit and new Run lead joint for spigot socket cast iron pipes and fitting, including cauking properly and making joint leak proof of size 80mm bore |
| 51 | All as per item No 50 above ……….. But for 100 mm bore |
| 52 | All as per item No 50 above ……….. But for 150 mm bore |
| 53 | All as per item No 50 above ……….. But for 200 mm bore |
| 54 | All as per item No 50 above ……….. But for 300 mm bore |
| 55 | Taking down existing UNSV sluice valve and supply & fix new Sluice valve of rising spindle type (Gear type) PN-1.6 heavy duty ISI marked as per (IS-14846) with flanged ends with 02 Nos of rubber gaskets, nut bolts and washers along with SS spindle and oprating wheel of size 80 mm bore |
| 56 | All as per item No 55 above ……….. But for 100mm bore |
| 57 | All as per item No 55 above ……….. But for 150mm bore |
| 58 | All as per item No 55 above ……….. But for 200 mm bore |
| 59 | M&L for rubber tyton joints for suitable for sockets and spigot CI pipes including rubber gasket of size 80mm bore |
| 60 | All as per item No 59 above ……….. But for 100mm |
| 61 | Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box ofsluice valve spindle brass including taking apart and reassembling of 200 MM complete all as specified and directed byEngineer-in-Charge. |
| 62 | Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box ofsluice valve spindle including taking apart and reassembling of 150 MM complete all as specified and directed byEngineer-in-Charge. |
| 63 | Taking out sluice valves refacing, regrinding and refixing including Repacking stuffing box ofsluice valve spindle including taking apart and reassembling of 80 MM complete all as specified and directed byEngineer-in-Charge. |
| 64 | M&L in repair of rusted & crack CI water branch connection 80 to 100mm dia by using mechanical joint with connecting all accessories complete all as specified and directed byEngineer-in-Charge. Note :(i) cost of gasket and nut bolts ,washers'jointing of materials as required are inclusive in above job.ii) Required T&P for job is provided by the Contractor is deemed to be included in the item rate.(iii) Excavation for pipe is included in job Work. |
| 65 | All as per item No 64 above but for size of pipe line 150 mm to 300 mm |
| 66 | M&L for dismantling old wall valve chamber and construction of brick masonary new valve pit chamber of size 900mmx900mmx900mm (internal ) size 100mm thick PCC 1:4:8 type D2 lean concrete foundation using 40mm graded stone aggregate providing well burnt brick masonary wall of 23mm thick built in CM 1:6 rendering in cement 1:6 finished even smooth using extra cement internally and 20mm thick in CM 1:4 and finished fair and even supply and fix 2.00 mm thick MS sheet steel cover fixed on 50mmx50mmx6mm thick angle iron frame embeded in PCC coping with locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron applying two coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed. |
| 67 | All as per item No 66 above but for chamber of size 1200mmx1200mmx1200mm |
| 68 | Dismantaling of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level). |
| 69 | M&L for Cement concrete 1:2:4 B-2 using 40mm graded stone aggregate in foundations, filling and mass concrete |
| 70 | S&F in replacement inline automatic water pressure pump, house hold with wall mounting bracket suitable cap upto 0.5 HP single phase 230volt Complete all as specified and directed( Note- including all fittings and fixtures as required) UPA15-160 MODEL Make-Grundfos/wirlpool/kar/Anchor |
| 71 | S&F in replacement inline automatic water pressure pump, house hold with wall mounting bracket suitable cap upto 0.5 HP single phase 230volt Complete all as specified and directed( Note- including all fittings and fixtures as required) Make-Crompton/Kirloskar/Grundfos |
| 72 | M&L for repaire inline automatic water pressure pump cap 0.5 HP single phase 230volt Complete including all fittings and fixtures all as specified and directed. |
| 73 | S&F in repair Mild steel work in Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 |
| 74 | Testing of Treated water (Drinking water) sample as per IS - 10500 including collecting of sample from the pump house and handed over it to the authoriesed lab for the testing purpose all as specified and directed. |
| 75 | Testing of Raw water sample as per IS - 10500 including collecting of sample from the pump house and handed over it to the authoriesed lab for the testing purpose all as specified and directed. |
| 76 | S&F in replacement Air release valve of size 80/100 mm along with rubber washer nuts & bolts etc. Complete all as specified and directed |
| 77 | Disconnection and removing the unserviceable Electric motor 120 HP and transporting the same to work shop for rewinding and fixing the same in its original position after repairs, including testing and commissioning complete all as directed |
| 78 | Material & labour rewinding of 120 HP electric motor with fine enameled bared copper conductor of same gauge weight and turn along with insulating materials such as impregnated paper, cotton tap, varnish etc and keeping the rewinding in to the hot air oven till moisture evaporates and achieving proper insulation results and reassemble the motor including taking out old rewinding complete all as directed. |
| 79 | Trimming and cutting of tree branches 50mm to 200 mm girth by using automatic hexa machine coming across LT over head line clearing the line around 2m single/both sides and disposal of branches from the site exeeding 50m and not exceeding 250m from site comlete all as directd by engr-in-Charge :- (i) Due care is to be while trimming/cutting the tree branches that there should no damage to over head line conductor/pole /or bldgs. In case due to any negligence, damage is caused to be make good/renewal by the contractor from his own resources and nothing extra is admissible. (ii) All safety to labourer must be adhered by the contractor during trimming and cutting of tree branches |
| 80 | Supply of Electric chain saw machine with 16inch cutting bar for home and professional use, overall length (without bar) 436mm saw chain, pitch 3/8\\" high performance , power 1300w chain /bar length 16\\" chain speed 12m/s , No load speed 6000/min, chain gauge 1.1 mm all as directed by Engr-In -Charge. |
| 81 | a) Supply & fix of reputeded make full bore SCADA based Electromagnetic flowmeter, size 300mm callibrated with certificate, including all accesseries, cable length- as required, local display- manual reading, remote monitoring- reading see in mobile and laptopand also print last six month hestorical DATA/Excel formate. Enclosser panel- safty Cever Meter, UPS - To Give 3 hours battery backup. With One Year Warranty. b) Supply and installing of all fitting including CI flange addeptor and jointing matterial etc. and commisining of Meter al as directed by Engr-in -Charge. ( Gunjkheda Pump House) |
| 82 | Supply install commisioning and testing of elctrochlorinatortor/sodium hypochloride generator dozing equipement for water disinfection system in renewal. Make: Pristine Water, Ti-anode, Industrial Devices(i) Brine SOLUTION PUMPSalt Solution pump of required capacity should be provided to supply salt solution to the Electrolyzer cell for the production of Sodium Hypochlorite solution with 1 Working and 1 Standby option. The Salt solution pump shall be Electronic Diaphragm Type, with suction strainer and non-return dosing assembly. (a) BRINE PUMP: 2 Nos. (1W+1S),Type : Metering Pump , Diaphragm: PTFE, MOC: PP/PVC, Capacity : 6 LPH, Pressure : 2 kg/cm2, Input : - 220V, 50 HZ, 1Ph(b) HYPO PUMP: 2 Nos. (1W+1S),Type: Metering Pump,Diaphragm: PTFE, Wetter Parts: PP/PVC, Capacity : 32 LPH, Pressure : 3 - 5 kg/cm2 , Input : - 220V/415V, 50 HZ (c) ACID PUMP: 1 No. Type: Magnetic type, Capacity: 900 LPH, Wetted Part: PP,Input : - 220V, 50 HZ, 1Ph (ii) HYDROGEN DILUTION BLOWERCentrifugal Blower with 1 Working and 1 Standby option shall be provided that will create a forced draft in the hypochlorite tank to evacuate the hydrogen produced during the process after it is diluted to a non-flammable mixture with air.(d) BLOWER: 2 Nos.(1W+1S), Type: Centrifugal, Air Capacity: 175 m3/hr, Drive: Direct Driven, MOC: GI Powder coated, Input : - 220V, 50 HZ, 1Ph (iii) Temperature Controllers- 2 Nos, Sensor Type: - RTD PT 100, Thermowell: - Titanium, Sensor Mounting: Electrolyzer outlet line, Controller Mounting: - In Control Panel (iv) Level Switches- 3 Nos Type: - Float type, Float MOC: - PP/PVC, Mounting: - Side mounting, Location: - At Brine & Hypo Tank (v) Rotameters- 3 Nos. Type: - Variable Area flow meter, Body MOC: - Acrylic, Float: - PTFE (Teflon), Mounting: - At Fresh water & Brine Lines (vi) Solenoid Valves- 3 Nos. Type: - Pilot Operated Diaphragm Valve, Size: - ½ “ , MOC: SS, Purpose: - ON/OFF Valve, Service: Fresh Water & Brine |
| 83 | Supply install commisioning and testing of elctrochlorinatortor/sodium hypochloride generator dozing equipement control panel and connected items for water disinfection system in renewal. Make: Pristine Water, Ti-anode, Industrial Devices (i) CONTROL PANELThe following parameters of the Electrochlorinator shall be controlled by a Control Panel: Level in Salt Solution Tank, Temperature of hypochlorite, Level in Hypochlorite Storage Tank, Input power to the panel shall be 220/415 VAC +/-5%, 1/3 Phase, 50 Hz , CONTROL PANEL: 1 No., Control type: Relay Logic, Consist of MCB’s, Contractors, Relays, Buzzer, push buttons, selector switches, indicators, Digital VAF Meter, bus bars & wiring, Enclosure: - Dust Proof / Version proof 14/16 SWG CRC sheet, Enclosure, Powder Coated in Siemens Gray, cable entry bottom, Approx. Size :(H1000 x W600 x D300), Input: 230V/415V, 50Hz . (ii) The freshly hypochloride solution shall be transfered automaticaly to enclosed tank of MOCLLDPE with inlet and outlet connections in addition, the tank shall be provided with a drain valve.HYPO TANK: 1 No., Type: - Cylindrical vessel with Lid, Flat bottom & Flat Top, Material : LLDPE (100 % Virgin & Food Grade), Capacity : 500 Liters (iii) Salt Solution Tank: The salt solution tank shall be provided with minimum one day storage of salt solution and having MOCLLDPE with inlet/outlet connectioin and floot valve on inline line. BRINE TANK WITH AGITATOR: 1 No., Type: - Cylindrical vessel with Lid, Flat bottom & Flat Top, Material : LLDPE (100 % Virgin & Food Grade) Capacity : 100 Liters, Agitator type: - Motor with Gear box, RPM: - 80-100, Input : - 220V, 50 HZ, 1Ph Blade & shaft MOC: - PVC or MS+FRP, Mounting: - Vertical (iv) ACID CLEANING UNIT: A Storage Tank for acid along with recirculating pump shall be provided to clean the Electrolyzers in case of scale formation. ACID TANK: 1 No.,Type: - Cylindrical vessel with Lid, Flat bottom & Flat Top, Material : LLDPE (100 % Virgin & Food Grade), Capacity : 50 Liters. (v) VALVES Type: - Ball Valve, MOC: - PVC,Size: - ½” , Qty. 30 Nos.(vi) Strainer : Type: - Y Type, MOC: - PVC , Size: - ½” ,Qty. 3 Nos. (vii) PIPE & FITTING: MOC: -PVC ,Size: - ½” , Qty. - As required within Electrochlorination system battery limits. (viii) CABLE, SKID & HARDWARE, Cable: - Power & Control Cable, Size: - As per the system requirements. Qty: - As required within Electrochlorination system battery limits, Skid MOC: - MS fabricated epoxy painted, Hardware: - Nut, Bolt, washers, Clamps etc.,Qty: As required within Electrochlorination system battery limits, Hardware MOC: - GI/SS |
| 84 | Supply install commisioning and testing of elctrochlorinatortor/sodium hypochloride generator dozing equipement electrolyzer assembly for water disinfection system in renewal. An Electrolyzer assembly shall have a capacity of 250 grams/hr. of equivalent chlorine as sodium hypochlorite solution. Anodes shall be Titanium ASTMB 265 & 348, with precious metal oxide coating. Cathodes shall be manufactured from Titanium ASTMB 265 & 348. The casing of the Electrolyzer Assembly shall be PVC/Acrylic. Make: Pristine Water, Ti-anode, Industrial Devices ELECTROLYZER: 2 Nos. (1W+1S), Capacity: 250 Grams/hr., Anode: Titanium as per ASTM B 265 or 348 Gr. 1 or 2, Cathode : Titanium as per ASTM B 265 or 348 Gr. 1 or 2, Coating : Mixed Metal Oxide Coated, Spacers : PVDF, Housing : Acrylic/PVC |
| 85 | Supply install commisioning and testing of elctrochlorinatortor/sodium hypochloride generator dozing equipement power supply for water disinfection system in renewal. Power for the electrolysis of brine shall be provided by Step Down Transformer and Rectifier. Power Supply shall be variable type and shall display the operating voltage and current. Input power shall be 220/415 VAC +/-5%, 1/3 Phase, 50 Hz. 1. DC RECTIFIER : 2 Nos. (1W+1S) Type : - AC to DC converter,Consist of Main Transformer, Three phase Dimmer (Manual) (If applicable), Diodes with Heat sinks, digital Voltmeter, Digital Ammeter, and shunt, Free standing sheet metal cabinet. TECHNICAL SPECIFICATIONS: Input Voltage 230/415 V, 1/3 phase, 50Hz, Output Voltage 20 Volts, Output Amperes 100 Amps, Metering,Digital Voltmeter, Digital Ammeter, cooling: Natural Air cooled, Ambient Temp. 50 Deg. C max. Cabinet / Housing: - Free Standing M S Cabinet, Installation Indoor. Supply and fixing in replacement Onload changeover switch AC-23 (side handle) in sheet enclosure 415 Volt , 50 Hz double pole 100 Amp all as specified and directed by EIC. Please Enable Macros to View BoQ information |