| 1 | Preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spotsdown and stopping etc and applying one coat of cement base paint all as directed |
| 2 | Preparation of old painted surfaces of steel exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 3 | M&L for complete removal of existing treatment of old surface of wall including brooming down / steel wire brushing, scrapping down smoke soot, mould, moss and efflorescent salts and trading oil and greasy spoutes and cleaning with water on wall and preparation of plastered surface of walls and applying Acrylic smooth exterior paint of required shade in two coats @1.67 ltr/10 Sqm over and including priming coat of exterior primer @2.20kg/10 sqm using mechanical means like roller or spray gun or manual as specified and directed by Engr-in-charge. |
| 4 | Preparation of newly plastered surface of walls and applying Acrylic smooth exterior paint of required shade two coat @1.67 ltr/10 Sqm over and including priming coat of exterior primer @2.20kg/10 sqm using mechanical means like roller or spray gun or manual as complete all as specified and directed by Engr-in-charge. |
| 5 | M & L for preparation of old plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and applying two coats of white wash including cleaning the floor/ joinery surfaces, glass pans all as directed. |
| 6 | Cleaning of the bushes/unwanted weeds, plants etc. or any rubbish material found along the security/boundary line of defence land upto 1.00 m width for periodical services to walls and removing the material complete all as specified and as directed by Engineer-in-Charge. |
| 7 | Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches, pillars but excluding ashlar facing, dressed stone work and precast concrete articles etc. , complete all as specified and directed. |
| 8 | Brick work with old size bricks having crushing strength not less than 75 Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. |
| 9 | All as per Serial Item No 8 above but except bricks, complete all as specified and directed. Note:- Servicable stone retrieved from Serial Item No 7 shall be reused. |
| 10 | Walling random rubble masonry with best quality locally available stone, uncoursed, well bonded, bedded, solidly hearted and built in cement mortar 1:4 (1 cement : 4 coarse sand), complete all as specified and directed. |
| 11 | All as per Serial Item No 10 above but except stone, complete all as specified and directed. Note:- Servicable stone retrieved from Serial Item No 7 shall be reused. |
| 12 | Taking down cement plaster on brick or stone walls, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. |
| 13 | Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) on fair faces of brick wall or stone masonry surfaces, surface finished even and smooth without using extra cement with WPC, complete all as specified and directed. Note:- water proofing compound shall be measured and paid separately. |
| 14 | M&L for rendering 10mm thick in cement mortar 1:3 on fair faces of RCC concrete surfaces including applying cement slurry on bottom of slab, chajjas, fin, facias etc and finished even and smooth without using extra cement complete all as specified and directed. |
| 15 | M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint complete all as specified and as directed. |
| 16 | Supply only integral water proofing compound . |
| 17 | Dismantling posts or struts (Wood, steel or RCC) any section, including taking out embedded portion, posts embedded in natural ground or lean concrete etc and making good disturbed portion, complete all as specified and directed . |
| 18 | Excavation in post holes (or similar holes) each n.exc. 0.5 cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m, in any type of soil and making good surfaces, complete all as specified and directed . |
| 19 | Plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete etc, complete all as specified and directed . |
| 20 | Rolled mild steel work as in posts & struts in fencing using angle iron or other sections, including cutting tops to shape as directed, drilled holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting and riveting etc and similar work conforming to Fe-290, Gde E-165, complete all as specified and directed . Note : Unit rate includes locking holes after fixing of barbed wire and welding to bent portion as directed. |
| 21 | Dismantling fencing wire mesh, any type, complete all as specified and directed. |
| 22 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified and directed. |
| 23 | Supply Only Chain link hot dipped galvanisd fencing, any size or type, complete all as specified and directed. |
| 24 | M&L for PCC 1:2:4 type B1 (Using 20 mm graded aggregate) as in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed by Engr in Charge. |
| 25 | Demolition of cement concrete unreinforced of any description in any position not otherwise specifically provided forcomplete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. |
| 26 | Providing precast cement concrete louvers and jallies, M-15, type B-0 with 12.50mm graded crushed stone aggregate 35mm thick (measured solid), including all mouldings but excluding frame set in CM 1:6, complete all as specified and directed. |
| 27 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 28 | Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed ballusters walk ways; railings; framework of water tanks and similar work conforming to Fe.290. Gde-E-165, complete all as specified and directed. |
| 29 | Applying two coats of synthetic enamel paint over a coat of red oxide on new steel or steel based surfaces of any description, exceeding 10cm width or girth including preparation of surfaces, complete all as specified and directed. |
| 30 | Demolition of cement concrete reinforced of any description in any position complete including removal of debris to a distance exc 1.50 km but n.exc 2 km, complete all as specified and directed. |
| 31 | Reinforced cement concrete, M-15 (Nominal mix), type B-1, (with 20mm graded crushed stone aggregate as) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 32 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) surface fair finished flat all as specified and directed. |
| 33 | Use and waste of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and directed. |
| 34 | Mild steel TMT bars 5 to 10mm dia , cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers and binders, all as specified. |
| 35 | M&L for precast reinforeced cement concrete 1:2:4, Type B1 (using 20 mm graded aggregate) as in in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set cement mortar 1:6 complete all as specified. |
| 36 | Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc., fixed in repair, complete all as specified and directed. (each line wire to be measured) |
| 37 | M&L for providing high tensile hot dipped galvanised Steel (GI) based concerntina coil of 60 cm dia over Y Shaped angle iron pickets over the boundary wall complete all as specified and as directed. |
| 38 | Restraining and rescuring including making good staples and tying with mild steel binding wire (wherever required) etc., in existing barbed wire fencing of any description, complete all as specified and directed.Note: Each line wire to be measured separately. Please Enable Macros to View BoQ information |