| 1 | 11 Mtr long WPB GI Pole(160x160) |
| 2 | Pressure Channel 100x50x6mm, 2.8Mtr 2 No with Galvanisation Charges |
| 3 | Transformer Mounting Channel G.I (100x50x6) mm(9.2 Kg/Mtr)x2.8 Mtr eachx 2 Nos with Galvanisation Charges |
| 4 | AB Switch & HG Fuse mounting channel G.I (75x40x6)mm 2.8 Mtr Long 4 Nos (6.8Kg/Mtr) with Galvanisation Charges |
| 5 | Cantilever channel for supporting HG Fuse (75x40x6)mm MS ANGLE 1 Mtr Long 2 Nos (6.8Kg/Mtr) with Galvanisation Charges |
| 6 | Cantilever channel for supporting HG Fuse (75x40x6)mm MS ANGLE 1 Mtr Long 2 Nos (4.5Kg/Mtr) with Galvanisation Charges |
| 7 | Angle for Cantilever arrengement for AB Switch & HG Fuse (50x50x6)mm 2Mtr Long 2 Nos (4.5Kg/Mtr) with Galvanisation Charges |
| 8 | angle mounting of LT distribution box (50x50x6)mm 3 Mtr long each (4.5 Kg/Mtr) with Galvanisation Charges |
| 9 | Disinsulator(T&C) 45 KN Polymer |
| 10 | H.W fitting(T&C) 45KN |
| 11 | 11 KV AB Switch 3 pole, 400A |
| 12 | 11 KV HG Fuse 3 pole, 400A |
| 13 | 11 KV Lighting Arrester 9KV, 5KA |
| 14 | LT Distribution Box with MCCB, Alluminium Busbar for 3 Bay with Kit kat fuse for 500KVA S/S |
| 15 | H.T Stay set (Complete) REC Construction Standard |
| 16 | HT Stay Insulator Type-C |
| 17 | Stay Clamp (1.9Kg/Pair) |
| 18 | 7/10 SWG Stay Wire (Garde-2) |
| 19 | G.I Pipe Earthing 40mm Dia medium gauge 3 Mtr long for Earthing device |
| 20 | Earthing Of Support Coil Type |
| 21 | No.6 G.I wire for Earthing |
| 22 | G.I flat (25x6mm) for Neutral & body Earthing of DTR |
| 23 | G.I Nut,Bol & Washer |
| 24 | 500KVA 11/0.4 KV (AL) Transformer with tap Changer, BIS Energy Level-II |
| 25 | 3.5Cx500mm2 LT PVC Cable (Un armoured) |
| 26 | Danger Board |
| 27 | Back Clamp for Danger Board 25x3mm G.I Earth flat, 0.59Kg/Mtr, Flat of 0.510mtr for each back Clamp |
| 28 | Anticlimbing Device (G.I barbed wire 3 Kg per support) |
| 29 | Back Clamp for anticlimbing device 25x3mm G.I Earth flat, 0.59Kg/Mtr, Flat of 0.510mtr for each back Clamp |
| 30 | Sundries |
| 31 | WPB 160x152 (30.44 KG/Mtr) 9 Mtr Long with Base Plate |
| 32 | 11 KV Lighting Arrester (For 11KV XLPE Cable) |
| 33 | 75x40x6 mm MS Channel with Galvanisation, 1.2 Mtr long 02 Nos(@6.8Kg/Mtr) for road support of Las |
| 34 | Heat shrinable jointing kit for 3Cx35 mm2 |
| 35 | 3Cx35 mm2 11KV XLPE Cable (Armoured) A2XFY |
| 36 | 7/10 G.I Stay wire for support of XLPE Cable |
| 37 | 11KV XLPE Cable Clamp to hold Support Wire |
| 38 | Pole Clamp for Eye Hook (for XLPE Cable) |
| 39 | Eye Hook for XLPE Cable |
| 40 | Suspension Clamp with Eye hook for XLPE Cable |
| 41 | Conductor dead end clamp suitable for bare Massenger XLPE Areial bunched Cable (25-70MM) |
| 42 | (25x4) mm GI Flat for earthing of XLPE Cable |
| 43 | G.I Pipe Earthing 40mm Dia medium gauge (3.25mm thick ness) 3 Mtr long |
| 44 | 11 KV V Cross arm (10.2 Kg Each) |
| 45 | G.I Back Clamp for 'v' Cross Arm (0.85 Kg Each) |
| 46 | 11 KV F Clamp 2.9 Kg |
| 47 | Disinsulator(T&C) 45 KN Polymer |
| 48 | H.W fitting(T&C) 45KN |
| 49 | 11KV Pin Insulator polymer |
| 50 | Earthing Of Support Coil Type (G.I) |
| 51 | G.I Nut,Bol & Washer |
| 52 | 100x50x6 mm MS Channel Staright cross arm (1.2mx02 pcs) (9.2 Kg/Mtr)+(0.2mx00 pcs) (9.2 Kg/mtr) for tapping & cut point pole+ Gallvanisation charges |
| 53 | Top Bracket 100x50mm MS Channel (0.2 Kg each) |
| 54 | Anticlimbing Device (G.I barbed wire 3 Kg per support) |
| 55 | Back Clamp for anticlimbing device 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 Nos per Pole = (8x0.59x0.510) |
| 56 | Danger Board |
| 57 | Back Clamp for anticlimbing device 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 2 Nos per Pole = (2x0.59x0.510) |
| 58 | Sundries |
| 59 | Material for Earthing include masonary for earth pit, Charcoal, Salt etc |
| 60 | Concreting of Support C.C 1:1.5:3, 0.55 Cum, @ 6400/- (J) |
| 61 | Concreting of Support C.C 1:1.5:3, 0.45 Cum, @ 6400/- (J) |
| 62 | Couping of poles in ratio 1:1.5:3, 1125 Cum @ Rs.6400.00(L) |
| 63 | 100x116 MM WPB Pole 11 Mtr |
| 64 | Earthing Of Support Coil Type (G.I) |
| 65 | Top Pressure Channel (100x50x6) mm MS Channel, 2.8 Mtr long, 2 Nos (9.2 Kg/Mtr) |
| 66 | MU Mounting Channel (100x50x6) mm MS Channel, 2.8 Mtr long, 2 Nos (9.2 Kg/Mtr) |
| 67 | (75x40x6) mm MS Channel for bracing 2.8 Mtr long, 2 Nos (9.2 Kg/Mtr) |
| 68 | (50x50x6) mm MS angle for bracing, 3 Mtr long, 2 Nos (4.5 Kg/Mtr) (total 6 Mtr long) |
| 69 | H.T Stay set (Complete) |
| 70 | HT Stay Insulator |
| 71 | Stay Clamp or stud clamp |
| 72 | 7/10 SWG Stay Wire |
| 73 | G.I Nut,Bol & Washer |
| 74 | 11 KV Lighting Arrester (For 11KV XLPE Cable) |
| 75 | (25x6) mm GI Flat (for MU & LA) |
| 76 | G.I Pipe Earthing 40mm Dia medium gauge (3.25mm thick ness) 3 Mtr long |
| 77 | Anticlimbing Device (G.I barbed wire 3 Kg per support) |
| 78 | Back Clamp for anticlimbing device 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 Nos per Pole = (8x0.59x0.510) |
| 79 | Danger Board |
| 80 | Back Clamp for anticlimbing device 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 2 Nos per Pole = (2x0.59x0.510) |
| 81 | Sundries for Danger Board, Anticlimbing Device etc |
| 82 | Cement concreting for stay Anchor plate with C.C 1:2:4, 0.2 Cum @ 6177.92/- (M) |
| 83 | Concreting of Support C.C 1:1.5:3, 1125 Cum, @ 6400/- (J) |
| 84 | Couping of poles in ratio 1:1.5:3, 0.375 Cum @ Rs.6400.00(K) |
| 85 | WPB 160x152 (30.44 KG/Mtr) 9 Mtr Long with Base Plate |
| 86 | Top Pressure Channel (100x50x6) mm 9.2 Kg/Mtr. Each Channel length 2.8 Mtr, long, 2 Nos Channel |
| 87 | AB Switch mounting channel (100x50x6) mm 9.2 Kg/Mtr. Each Channel length 2.8 Mtr, long, 2 Nos Channel |
| 88 | DP bracing channel (75x40x6) mm 6.8 Kg/Mtr. Each Channel length 2.8 Mtr, long, 4 Nos Channel |
| 89 | G.I bracing Angle (50x50x6) mm 4.5 Kg/Mtr. Each angle length 4 Mtrlong, 2 Nos angle |
| 90 | AB Switch handle mounting channel (75x40x6) mm 6.8 Kg/Mtr. Each Channel length 1.0 Mtr, long, 1 No Channel |
| 91 | Fish Plate 50x8 mm, 0.97 Kg/Mtr, each 0.280 Mtr Length |
| 92 | Disc Insulator(T&C) 45 KN Polymer |
| 93 | H.W fitting(T&C) 45KN |
| 94 | PG Clamp for 55 mm2 AAA |
| 95 | 11KV Pin Insulator polymer for pin point pole and jumpering |
| 96 | Lighting Arrester (9KV,10KA) Station Class |
| 97 | 11 KV AB Switch 3 Pole 400A (Hz) |
| 98 | Earthing Of Support Coil Type (G.I) |
| 99 | Anticlimbing Device (G.I barbed wire 3 Kg per support) |
| 100 | Back Clamp for anticlimbing device 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 Nos per Pole = (8x0.59x0.510) |
| 101 | Danger Board |
| 102 | Back Clamp for anticlimbing device 25x3mm.flat, 0.59Kg/Mtr, Flat of 0.510mtr length 2 Nos per Pole = (2x0.59x0.510) |
| 103 | G.I Pipe Earthing 40mm Dia medium gauge (3.25mm thick ness) 3 Mtr long |
| 104 | (25x6) mm GI Flat (for Earthing) |
| 105 | H.T Stay set (Complete) |
| 106 | HT Stay Insulator |
| 107 | Stay Clamp or stud clamp |
| 108 | 7/10 SWG Stay Wire |
| 109 | G.I Nut,Bol & Washer |
| 110 | Sundries |
| 111 | Material for Earthing include masonary for earth pit, Charcoal, Salt etc |
| 112 | Concreting of Support C.C 1:1.5:3, 0.45 Cum, @ 6400/- (K) |
| 113 | Couping of poles in ratio 1:1.5:3, 1125 Cum @ Rs.6400.00(L) |
| 114 | Cement concreting for stay Anchor plate with C.C 1:2:4, 0.2 Cum @ 6177.92/- (M) |
| 115 | 2.5 mm2 10 core Armoured Control Cable |
| 116 | G.I Bolts & Nuts |
| 117 | Sundries for Danger Board, Anticlimbing Device etc Please Enable Macros to View BoQ information |