| 1 | DT ( Supply Part ) |
| 2 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 3 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 4 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 5 | 185mm² (2Ckt)Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63kva DTs |
| 6 | 9 Mtr. Long Pole,ST-410 SP33) |
| 7 | 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 8 | GI Channel/Angle/Flat of sizes including clamps |
| 9 | Galvinized Nuts and Bolts. |
| 10 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 11 | 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 12 | LT Distribution Box for 63kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions |
| 13 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut- bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wirecomplete |
| 14 | 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible) |
| 15 | Wedge Connectors/ PG Clamps |
| 16 | Danger Plates with Clamps |
| 17 | GI Barbed Wire for Anti Climbing |
| 18 | Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 19 | Painting of Poles Red Oxide |
| 20 | Painting of Poles Aluminium Paint |
| 21 | Sundry items like aluminium lugs, Jumpers, binding Tape, |
| 22 | Transformer Fencing |
| 23 | Installation/Testing /Commissioning Part of Substation. |
| 24 | Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type |
| 25 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 26 | 11 kV Horn Gap Fuse Set 3 Phase 200A |
| 27 | 185mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type for 63kva DTs |
| 28 | 9 Mtr. Long Pole,ST-410 SP33) |
| 29 | 33kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 30 | GI Channel/Angle/Flat of sizes including clamps |
| 31 | Galvinized Nuts and Bolts. |
| 32 | Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 33 | 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm |
| 34 | LT Distribution Box for 63kVA DTR with TPN MCCB short ckt rating 16 KA for incomer 120Amp and suitable MCCBs for outgoing circuits with terminal extensions |
| 35 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut- bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wirecomplete |
| 36 | 3-Ø, 4-Wire Trivector Meter with CT(LTCT AMR compatible) |
| 37 | Wedge Connectors/ PG Clamps |
| 38 | Danger Plates with Clamps |
| 39 | GI Barbed Wire for Anti Climbing |
| 40 | Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 41 | Painting of Poles Red Oxide |
| 42 | Painting of Poles Aluminium Paint |
| 43 | Sundry items like aluminium lugs, Jumpers, binding Tape, |
| 44 | Transformer Fencing |
| 45 | HT Line Supply Part |
| 46 | 11 Mtr. Long Pole( ST-410 SP56) |
| 47 | 9 Mtr. Long Pole( ST-410 SP33) |
| 48 | GI V cross-arm with top Bracket including clamp(14.631 kg) |
| 49 | Supply of GI Channel X-arm 1600mm long including clamps and braces (75X40X6mm GI Channel of 1600mm long=40 No.(weight per channel=11.42Kg,back clamp for cantiliver 50X8mm, 365mm long =1.15Kg Total weight=12.57Kg/channel +clamp GI angle 65XiX6mm, 1760mm long =40 nos (weight=10.21Kg, Guy clamp for cantiliver 50X8mm,300mm long=.9Kg, Total weight=11.11Kg Total weight of X-arm and cantiliver=23.68Kg |
| 50 | 30 mm² ACSR Conductor |
| 51 | 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 52 | 33KV Polymeric Composite Disc Insulator 36KN, min failing load 70KN, Lightining Impulse 170KV Positive and 180KV Negative, Creepage distance 900mm |
| 53 | Galvinized Nuts and Bolts |
| 54 | Danger Plates with Clamps |
| 55 | Anti-Climbing Device with Clamps |
| 56 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 57 | Red Oxide |
| 58 | Aluminium Paint |
| 59 | Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 60 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 61 | HT Line Installation/Testing /Commissioning Part |
| 62 | 11 Mtr. Long Pole( ST-410 SP56) |
| 63 | 9 Mtr. Long Pole( ST-410 SP33) |
| 64 | GI V cross-arm with top Bracket including clamp(14.631 kg) |
| 65 | Supply of GI Channel X-arm 1600mm long including clamps and braces (75X40X6mm GI Channel of 1600mm long=40 No.(weight per channel=11.42Kg,back clamp for cantiliver 50X8mm, 365mm long =1.15Kg Total weight=12.57Kg/channel +clamp GI angle 65XiX6mm, 1760mm long =40 nos (weight=10.21Kg, Guy clamp for cantiliver 50X8mm,300mm long=.9Kg, Total weight=11.11Kg Total weight of X-arm and cantiliver=23.68Kg |
| 66 | 30 mm² ACSR Conductor |
| 67 | 33kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 68 | 33KV Polymeric Composite Disc Insulator 36KN, min failing load 70KN, Lightining Impulse 170KV Positive and 180KV Negative, Creepage distance 900mm |
| 69 | Galvinized Nuts and Bolts |
| 70 | Danger Plates with Clamps |
| 71 | Anti-Climbing Device with Clamps |
| 72 | Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip. |
| 73 | Red Oxide |
| 74 | Aluminium Paint |
| 75 | Cement bottoming 1:2:4 mix as per REC standards .5cum/pole |
| 76 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 77 | LT Line Supply Part |
| 78 | 8 Mtr. Long Pole( ST-410 SP15) |
| 79 | GI Channel X ARM (75X40X6mm) 4ft along with GI Clamp, 50x8mm, (4ft=8Kg, 1 No. clamp=0.83Kg = total weight = 8.83 kg) |
| 80 | 30mm² ACSR Conductor |
| 81 | 16kN Polymer Shackle Insulators |
| 82 | Galvinized Nuts and Bolts. |
| 83 | Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip. |
| 84 | Aluminium Paint |
| 85 | Red Oxide |
| 86 | Cement bottoming 1:2:4 mix as per REC standards .45cum/pole |
| 87 | LT Line Installation/Testing /Commissioning Part |
| 88 | 8 Mtr. Long Pole( ST-410 SP15) |
| 89 | GI Channel X ARM (75X40X6mm) 2ft along with GI Clamp, 50x8mm, (2ft=8Kg, 1 No. clamp=0.83Kg = total weight = 4.83 kg) |
| 90 | 30mm² ACSR Conductor |
| 91 | 16kN Polymer Shackle Insulators |
| 92 | Galvinized Nuts and Bolts. |
| 93 | Earthing Complete by GI Spiral/Rod 20mm 2.5 mtr long through GI Strip. |
| 94 | Aluminium Paint |
| 95 | Red Oxide |
| 96 | Cement bottoming 1:2:4 mix as per REC standards .45cum/pole |
| 97 | Dismentling Part |
| 98 | Dismentling of 63KVA Distribution Transformer and shifting at new site ans return back the allied materials of old Sub-Station to Divisional Store Choglamsar. |
| 99 | Dismantling and re-erection of 8Mtr Pole along with all accessories Please Enable Macros to View BoQ information |