| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil : |
| 2 | Providing and laying of boulders stone /stone soling under over size 160mm hand packed including ramming, dressing and watering all complete.(Incl. all sorts of carriage). |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, beam plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form work for: |
| 8 | Foundations, footings, bases for columns |
| 9 | Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Hot rolled deformed bars |
| 11 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 12 | Providing and fixing of colour coated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.50 mm thick with zinc coating not less than 275 gram/m2 including Ridges/Hips velley etc all complete job as per direction of Engineer Incharge at site. |
| 13 | Providing and fixing plained eaves boarding. 2nd class kail wood 250x32 mm (nominal size ) |
| 14 | Providing and fixing Polycarbonite sheet in roof all cost and carriage complete job as per direction of Engineer Incharge at site |
| 15 | Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 16 | Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) as per direction of Engineer Incharge at site |
| 17 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) including Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. including all cost and carriage complete job |
| 18 | 20mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 19 | Distempering with 1st quality acrylic distemper (ready mixed)having VOC content less than 50 gms/litre,two or more coats on new work of approved manufacturer, of required shade and colour complete as per manufacturer’s specifications |
| 20 | Carriage of materials by Mechanical Transport including loading, unloading and stacking complete job |
| 21 | Aggregate upto 20 km. |
| 22 | Sand upto 20 km. |
| 23 | Bricks upto 85 km. |
| 24 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm including all cost and carriage complete job |
| 25 | Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminum primer on both sides & edges, including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodized aluminum (with 15 micron anodic coating) Tsections 35 x15x1.5 mm size main runners, cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer (aluminum frame work shall be paid separately). |
| 26 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: 20 mm dia. nominal bore complete job as per direction of Engineer Incharge at site. |
| 27 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: 15 mm dia. nominal bore complete job as per direction of Engineer Incharge at site. |
| 28 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 20 mm nominal bore |
| 29 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)15 mm nominal bore |
| 30 | Providing and fixing gun metal non-return valve of approved quality (screwed end) as per direction of Engineer Incharge at site |
| 31 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 32 | Providing and fixing of PVC pipe 75mm dia complete job as per direction of Engineer Incharge at site |
| 33 | Providing and fixing of PVC pipe 100mm dia complete job as per direction of Engineer Incharge at site |
| 34 | Providing and fixing of PVC door bend 75mm dia complete job as per direction of Engineer Incharge at site |
| 35 | Providing and fixing of PVC T 100mm dia complete job as per direction of Engineer Incharge at site |
| 36 | Providing and fixing of PVC Cap 100mm dia complete job as per direction of Engineer Incharge at site |
| 37 | Providing and fixing of PVC bend dia complete job as per direction of Engineer Incharge at site |
| 38 | Providing and fixing of PVC 75mm dia pipe for main hole conect complete job as per direction of Engineer Incharge at site |
| 39 | Providing and fixing of PVC Bend 75mm Dia complete job as per direction of Engineer Incharge at site |
| 40 | Providing and fixing of PVC bowel 100mm Dia complete job as per direction of Engineer Incharge at site |
| 41 | Providing and fixing of PVC bowel 75mm Dia complete job as per direction of Engineer Incharge at site |
| 42 | Providing and fixing of PVC Trap 100mm complete job as per direction of Engineer Incharge at site |
| 43 | Providing and fixing of PVC Trap 75mm complete job as per direction of Engineer Incharge at site |
| 44 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 45 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 literwhite P.V.C automatic flushing cistern. |
| 46 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. |
| 47 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. Internal work-exposed on wall with clamps at 1.00 meter spacing |
| 48 | PN-16 pipe, 16mm OD(SDR-7.4) |
| 49 | PN-16 pipe , 20mm OD(SDR-7.4) |
| 50 | PN-16 pipe , 25mm OD(SDR-7.4) |
| 51 | PN-16 pipe , 32mm OD(SDR-7.4) |
| 52 | Providing and fixing PPR Unions |
| 53 | PPR Union 20mm |
| 54 | PPR Union 25mm |
| 55 | PPR Union 32mm |
| 56 | Providing and fixing of 15mm nominal bore mixer bib cock of approved quality/ manufacture complete job as per direction of Engineer Incharge at site |
| 57 | Providing and fixing of 15mm nominal bore two way bib cock of approved quality/ manufacture complete job as per direction of Engineer Incharge at site |
| 58 | Providing and fixing in position 50 litter water gyser (ISI Mark/standard manifacture) including all necessay fittings ( 3pin electrict socket and wiring) main line from nearest source complete job as per direction of Engineer incharge at site. Please Enable Macros to View BoQ information |