Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil.i. 1 meter from cutting edge |
| 2 | i. 25 meter beyond 1 m from cutting edge |
| 3 | iii. 50 meter beyond 1 m from cutting edge |
| 4 | Extra for additional lift of 1.5 mtr or part thereof in excavation/banking excavated or stacked material.i. In all kinds of soils. |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. (Subject to actual quantities during execution). |
| 6 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m in -All kinds of soil. |
| 7 | Open timbering in trenches including strutting and shoring complete (measurements to be taken of the face area timbered):i. Depth not exceeding 1.5 m. |
| 8 | i. Depth exceeding 1.5 m but not exceeding 3 m |
| 9 | Depth exceeding 3 m but not exceeding 4.50 m |
| 10 | Supply and filling of 2nd class sand / stone dust around pipes at different spots including cost of material i.e. stone dust from available approved source including all carriages, leads and lifts upto the site of work including spreading of stone dust, levelling dressing and watering including compaction after each 15cms thickness in all respects. Complete Job. (Subject to actual quantities during execution). |
| 11 | Supply and Filling of trenches by GSB / Nallah Muck from approved source including all carriages upto actual site of work. The material shall be natural having durable particles graded from fine to coarse in a uniform combination with no boulders larger than 80mm in size. It shall not contain excessive quantity of loam. The item including ramming, consolidation in layers, charges of T&P, equipment’s etc. required for completion of job. |
| 12 | Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same in- All kinds of soil. |
| 13 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. |
| 14 | Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared |
| 15 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.i. Beyond 30cm girth upto and 60cm girth |
| 16 | ii. Beyond 60cm girth upto and 120cm girth |
| 17 | iii. Beyond 120cm girth upto and 240cm girth |
| 18 | iv. Above 240cm girth |
| 19 | Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. (Subject to actual quantities during execution). |
| 20 | Removal of unhygienic materials (so classified by the site engineer) from designated sites and its disposal as per directions, all inclusive. |
| 21 | Disposal of surplus excavated material by mechanical transport including loading, unloading & stacking. (Deductions on account of use of departmental men and machinary shall be as per actual).i. For an avg lead of 1km. |
| 22 | i. For an avg lead of 2km. |
| 23 | For an avg lead of 3km. |
| 24 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: i. 1:3:6 or richer mix (i/c equivalent design mix) |
| 25 | ii. 1:4:8 or leaner mix (i/c equivalent design mix) |
| 26 | Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. |
| 27 | Extra for cutting reinforcement bars manually/by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional areas of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 28 | Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work |
| 29 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge In cement mortar.i. In mud mortar. |
| 30 | ii. In Cement mortar. |
| 31 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks shall be measured) : i. From brick work in mud mortar |
| 32 | ii. From brick work in cement mortar |
| 33 | Demolishing stone rubble masonry manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar. |
| 34 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: i. In cement mortar |
| 35 | Removing mortar from and cleaning stones and concrete articles (net quantity of stacks of cleaned materials will be measured) i. In cement mortar |
| 36 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. |
| 37 | Dismantling steel work in single sections including dismembering and stacking within 50 meters lead in : i. R.S. Joists. |
| 38 | ii. Channels, angles, tees and flats. |
| 39 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 meters lead. |
| 40 | Dismantling steel work manually/by mechanical means in built up sections without dismembering and stacking within 50 meters lead as per direction of Engineer-in-charge: |
| 41 | Extra for dismantling trusses, rafters, purlins etc. of steel work for every additional span of one meter or part thereof beyond 10 meters. |
| 42 | Extras for dismantling trusses, rafters, purlins etc. of steel work for every additional height of one meter or part thereof beyond 5 meters. |
| 43 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 meters lead. i. For thickness of tiles 10 mm to 25 mm |
| 44 | ii. For thickness of tiles above 25 mm and upto 40 mm. |
| 45 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead : i. Of area of 3 sqm. and below. |
| 46 | ii. Of area beyond 3 sqm |
| 47 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead : i. Of area of 3 sqm. and below |
| 48 | ii. Of area beyond 3 sqm. |
| 49 | Dismantling wood work in frames, trusses, purlins and rafters upto 10 meters span and 5 meters height including stacking the material within 50 meters lead : i. Of sectional area 40 sqcm. and above. |
| 50 | ii. Of sectional area below 40 sqcm. |
| 51 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional span of one meter or part thereof beyond 10 meters : i. Of sectional area 40 sqcm and above. |
| 52 | ii. Of sectional area below 40 sqcm. |
| 53 | Extra for dismantling trusses, rafters, purlins etc. of wood work for every additional height of one meter or part thereof beyond 5 meters : i. Of sectional area 40 sqcm. and above. |
| 54 | ii. Of sectional area below 40 sqcm. |
| 55 | Providing and laying of dry stone soling in foundation/trenches hand packed and consolidated by hand ramming. (Subject to actual quantities during execution). |
| 56 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: i. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). |
| 57 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: i. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 58 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size.) |
| 59 | Providing and laying in position reinforced cement concrete 1:2:4 (1 Cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size crushed stone agg) excld. the cost of centering, shuttering and reinforced steel.) upto plinth level for saddle/anchor/thrust blocks. (Subject to actual quantities during execution). |
| 60 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 61 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 62 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 63 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etc upto floor V level, including curing but excluding the cost of centring, shuttering and finishing with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 64 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 65 | Centering and shuttering including strutting, propping etc. and removal of form for:(Deductions on account of use of departmental men and machinary shall be as per actual)i. Foundations, footings, bases of columns etc. for mass concrete. |
| 66 | ii. Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. |
| 67 | iii. Suspended floors, roofs, landings, balconies and access platforms. |
| 68 | iv. Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 69 | v. Columns, pillars, piers, abutments, posts and struts. |
| 70 | vi. Stairs (excluding landings) except spiral staircases. |
| 71 | Reinforcement for R.C.C. work including straightening cutting, bending, placing in position and binding all complete (TMT BARS) for saddle/anchor/thrust blocks. (Subject to actual quantities during execution). |
| 72 | Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand).a. Including cost of stones. |
| 73 | Excluding cost of stones. |
| 74 | Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone. Nallah |
| 75 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :1.4 Cement mortar ( 1 cement : 4 coa rse sand).inery up to site for completion of job. (Subject to actual quantities during execution). |
| 76 | 12mm cement plaster finished with a floating coat of neat cement of mix : 1 : 3 (1 cement : 3 fine sand). |
| 77 | Pointing on stone work with cement mortar 1 : 3 (1 cement : 3 fine sand).i. Raised and cut Pointing |
| 78 | Providing, fixing of M.S fittings viz bends of suitable degrees / size to be fabricated out of 8mm to 10mm thick MS. plate as per the requirement of site. This item includes cost of lead, spun yarn, R.I. cloth and lead caulking, lead beating with insertion of spun yarn etc. The fittings should be leak proof and should be painted with Anticorrosive Red Oxide Primer and incld. all carriages, leads lifts, etc. complete. (Subject to actual quantities during execution). |
| 79 | Welding of pipe / pipe fittings by way of engaging generator, welding set including all types of carriage involved. (Complete Job) (Subject to actual quantities during execution). |
| 80 | Structural steel work in welded built up sections for angles, channels, girders, gusset plates etc, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (welded or bolted). This item includes all carriages, charges of welder, equipments and machinery up to site for completion of job. (Subject to actual quantities during execution). |
| 81 | Dismantling of dislocated joints, repairs by way of welding of joints, flanged bends including cost of hire charge of DG set on vehicle including cost of equipment etc. complete. |
| 82 | Renewing glass panes, with putty and nails wherever necessary including raking out old putty : a. Float glass panes of thickness 4.0 mm(weight not less than 10kg/sqm) |
| 83 | b. Float glass panes of thickness 5.0 mm(weight not less than 12.5 kg/sqm) |
| 84 | Renewing glass panes, with wooden fillets wherever necessary : a. Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm) |
| 85 | b. Float glass panes of thickness 5.0 mm (weight not less than 12.5 kg/sqm) |
| 86 | Providing & fixing White vitreous china water closet squatting pan(Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Long pattern W.C Pan of size 580x440 mm. |
| 87 | Desilting of various structures (Clarifloculators, Backwash tanks, Raw/ Settled water channels, zero effluent, service reservoirs etc. including disposal of desilting material from site premises with all carriages lead and lifts etc. The job also includes washing and cleaning of walls, beds drains and floor etc. with bleaching powder solution complete job. |
| 88 | Clearing snow (with frost) from Roads, manually using picks and shovels; snow depth upto 150 mm. |
| 89 | Clearing Snow (without frost) from Roads, manually;i. Snow depth 150mm. |
| 90 | i. Snow depth over 150mm but 250mm |
| 91 | ii. Snow depth 250mm but 350mm |
| 92 | Snow depth 350mm but 450mm |
| 93 | Fixing of chain link fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge. This item also includes carriage of chain link fencing from Divisional Store upto site of work. |
| 94 | Fixing charges of MS lids of different size for Sluice Chambers etc. including concreting, angle irons, locking arrangements, hinges etc. required for the completion of job. This item also includes carriage of lids from Divisional Store upto site of work. |
| 95 | Replacement of old worn out/damaged manually operated winches machines for M.S. Gates with new ones as per the directions of engineer incharge. This item includes cost of providing and fixing of new winches including fitting and all carriages up to site complete job. (Subject to actual quantities during execution). |
| 96 | Repairs to manually operated winch gates, trash guards by means of replacement of channels , M.S. Gates, Bearings including dismantling and refixing of the same as per the directions of engineer incharge. (Subject to actual quantities during execution). |
| 97 | Repairs/rethreading/replacement of sluice rod and providing of new check nut made of gun metal and replacement of worn out parts by new ones if required at site incl. all complete . The entire assembly is to be re-fixed in its original position after carrying out necessary repairs. The job includes all carriages of materials, tools and plants and shall be paid in fitted and fixed form after testing on full water load and successful commissioning. Complete job. (Deductions on account of use of departmental men and machinery shall be as per actual).i. 900mm dia Butterfly Valve |
| 98 | i. 700mm dia Butterfly Valve |
| 99 | ii. 900mm dia Sluice Valve |
| 100 | iii. 600mm dia Sluice Valve |
| 101 | iv. 500 / 450mm dia Sluice Valve |
| 102 | v. 350 / 300mm dia Sluice Valve |
| 103 | 200/150mm dia Sluice Valve |
| 104 | Dismantling of spindle rod and check nuts of flanges type sluice valves by way of manufacturing of new spindle / rod made out of mild steel and new check nut made out of gun metal material. The job includes dismantling of sluice valve reassembling after fixing of spindle and check nut duly manufactures and threaded in workshop including cost of welding, packing, carriage to & from upto the workshop and back to site of work (Complete job) from 100mm dia Slucie Valve upto 450mm dia Slucie Valve. |
| 105 | Dismantling of spindle / rod and check nuts of flanged type sluice valves by way of manufacturing of new spindle /rod made out of mild steel only. The job includes dismantling of sluice valve reassembling after fixing of spindle and check nut duly manufactures and threaded in workshop including cost of welding, packing, carriage to & fro upto the workshop and back to site of work (Complete job) from 100m dia Sluice valve upto 450mm dia Sluice valve. |
| 106 | Dismantling of spindle / rod and check nuts of flanged type sluice valves by way of manufacturing of new check nut made out of gun metal material. The job includes dismantling of sluice valve reassembling after fixing of spindle and check nut duly manufactures and threaded in workshop including cost of welding, packing, carriage to & fro upto the workshop and back to site of work (Complete job) from 100m dia Sluice valve upto 450mm dia Sluice valve. |
| 107 | Overhauling of flanged type sluice valves by way of replacing of gland packing, non-magnetic nuts bolts and washers including R.I. cloth washers including oiling and greasing. The job includes dismantling of sluice valve reassembling after carrying out necessary repairs rod to be threaded in workshop including cost of welding, packing, carriage to & fro upto the workshop and back to site of work from 100m dia Sluice valve upto 450mm dia Sluice valve (Complete job). |
| 108 | Dismantling of air blower / backwash motors and pumps / Alum motors / bleaching motors of filtration plants by way of rewinding of core made out of copper metal fiber superior type of required thickness and guage. The job also includes all sorts of carriage from site to work upto workshop to & fro including testing and commissioning of following capacity.i. For 0.50HP to 2.00HP |
| 109 | i. For 3.00HP to 5.00HP |
| 110 | For 30.00HP to 40.00HP |
| 111 | Providing and fixing of running V-Belt of groove type for air blower, the job includes dismantling damaged ones and fixing of new ones including successful testing, commissioning. All types of carriage complete. |
| 112 | Dismantling of complete reduction gear unit of de-sludge bridge for repairs by way of providing & manufacturing of complete reduction gear with hub. The job includes casting of brass material, grinding & finishing of virme in order to make the new teeth, replacement of damaged oil seals by way of new one, replacement of ball bearings, pouring of required specific gravity gear oil I order to run the reduction gear in smooth order, refixing of same at the site of work including all sorts of carriage from site of work upto workshop and back to site of work including testing and successful commissioning (Complete Job). |
| 113 | Dismantling of churner of de-sludge bridge for repairs by way of providing & fixing of angle iron frame work complete, including replacement of damaged oil seals by way of new one, replacement of ball bearings, pouring of required specific gravity gear oil I order to run the reduction gear in smooth order, refixing of same at the site of work including all sorts of carriage from site of work upto workshop and back to site of work including testing and successful commissioning (Complete Job). |
| 114 | Providing and fixing of dry 50HP, 100A Starter of approved Make, the job includes dismantling of damaged / non functional starter and fixing of new one including all sorts of carriages from source to workshop including carriages of salvaged materials from filtration plant upto Divisional Sores including testing, installing and commissioning complete job. |
| 115 | Providing and fixing of dry 40HP 100A Starter of approved Make, the job includes dismantling of damaged / non functional starter and fixing of new one including all sorts of carriages from source to workshop including carriages of salvaged materials from filtration plant upto Divisional Sores including testing, installing and commissioning complete job. |
| 116 | Providing and fixing of dry 30HP 100A Starter of approved Make, the job includes dismantling of damaged / non functional starter and fixing of new one including all sorts of carriages from source to workshop including carriages of salvaged materials from filtration plant upto Divisional Sores including testing, installing and commissioning complete job. |
| 117 | Providing and fixing of dry 5.0HP Starter of approved Make, the job includes dismantling of damaged / non functional starter and fixing of new one including all sorts of carriages from source to workshop including carriages of salvaged materials from filtration plant upto Divisional Sores including testing, installing and commissioning complete job. |
| 118 | Overhauling voltage stabilizers installed at site. The job includes pouring/filling of transformer oil of required specified gravity, replacement of driven rotars (automatic), replacement of voltage meters, Amp meters, indicators, thimbles etc. complete job, making the unit complete functional for bearing of required load. The job also includes labour charges, cost of wiring, pin sockets and all sorts of carriages from site of work upto the workshop & back to actual site of work incld. installation at site & testing, successful commissioning complete job.i. 5KV to 10KV |
| 119 | i. 10KV to 20KV |
| 120 | ii. 20KV to 50KV |
| 121 | iii. 30KV to 100KV |
| 122 | iv. 60KV to 230KV |
| 123 | 100KV to 300KV |
| 124 | Providing and fixing of MCCB Havells make the job includes dismantling of damaged / non functional Amp. MCCB and fixing of new one including all sorts carriage from source to workshop including carriages of salvaged material from filtration plant upto Divisional Stores including testing, installating and commissioning complete job.i. 3 Pole 650Amp |
| 125 | i. 4 Pole 650Amp |
| 126 | ii. 3 Pole 630Amp |
| 127 | iii. 4 Pole 630Amp |
| 128 | iv. 3 Pole 400Amp |
| 129 | v. 4 Pole 400Amp |
| 130 | vi. 3 Pole 200Amp |
| 131 | vii. 4 Pole 200Amp |
| 132 | viii. 3 Pole 100Amp |
| 133 | ix. 4 Pole 100Amp |
| 134 | x. 3 Pole 63Amp |
| 135 | xi. 4 Pole 63Amp |
| 136 | xii. 2 Pole 32Amp |
| 137 | 1 Pole 16Amp |
| 138 | Decamping of main cable at filtration plants from LT poles, cutting of main cable by Hexa blades, providing / fixing of bone china insulators, thimbles, cost of PVC tape rolls, fuse wire, engagement of skilled / un skilled labourers, cost of rope, hire charges of long stair etc. complete job. |
| 139 | Providing, laying, fixing and commissionning of Un-armoured cable including proper termination of cables with properly crimped appropriate size. Aluminium thimbles properly taken over existing cable tray/ poles. The job includes all carriages, fitting costs etc. Nothing extra shall be paid.as per latest IS specifications and to be of approved make of cable size:A. Single CoreI. 4 sq. Mm |
| 140 | I. 6 sq. mm |
| 141 | II. 10 sq. mm |
| 142 | III. 16 sq. mm |
| 143 | IV. 25 sq. mm |
| 144 | V. 35 sq. mm |
| 145 | VI. 50 sq. mm |
| 146 | VII. 70 sq. mm |
| 147 | VIII. 95 sq. mm |
| 148 | IX. 120 sq. mm |
| 149 | X. 150 sq. mm |
| 150 | XI. 185 sq. mm |
| 151 | XII. 240 sq. mm |
| 152 | XIII. 300 sq. mm |
| 153 | XIV. 400 sq. mm |
| 154 | XV. 500 sq. mm |
| 155 | XVI. 630 sq. mm |
| 156 | XVII. 800 sq. mm |
| 157 | XVIII. 1000 sq. mm |
| 158 | B. 2-CoreI. 4 sq. mm |
| 159 | I. 6 sq. mm |
| 160 | II. 10 sq. mm |
| 161 | III. 16 sq. mm |
| 162 | IV. 25 sq. mm |
| 163 | V. 35 sq. mm |
| 164 | VI. 50 sq. mm |
| 165 | VII. 70 sq. mm |
| 166 | VIII. 95 sq. mm |
| 167 | IX. 120 sq. mm |
| 168 | X. 150 sq. mm |
| 169 | XI. 185 sq. mm |
| 170 | XII. 240 sq. mm |
| 171 | XIII. 300 sq. mm |
| 172 | XIV. 400 sq. mm |
| 173 | XV. 500 sq. mm |
| 174 | XVI. 630 sq. mm |
| 175 | XVII. 800 sq. mm |
| 176 | XVIII. 1000 sq. mm |
| 177 | C. 3- CoreI. 4 sq. mm |
| 178 | I. 6 sq. mm |
| 179 | II. 10 sq. mm |
| 180 | III. 16 sq. mm |
| 181 | IV. 25 sq. mm |
| 182 | V. 35 sq. mm |
| 183 | VI. 50 sq. mm |
| 184 | VII. 70 sq. mm |
| 185 | VIII. 95 sq. mm |
| 186 | IX. 120 sq. mm |
| 187 | X. 150 sq. mm |
| 188 | XI. 185 sq. mm |
| 189 | XII. 240 sq. mm |
| 190 | XIII. 300 sq. mm |
| 191 | XIV. 400 sq. mm |
| 192 | XV. 500 sq. mm |
| 193 | XVI. 630 sq. mm |
| 194 | XVII. 800 sq. mm |
| 195 | 1000 sq. mm |
| 196 | D. 3.5-CoreI. 4 sq. mm |
| 197 | I. 6 sq. mm |
| 198 | II. 10 sq. mm |
| 199 | III. 16 sq. mm |
| 200 | IV. 25 sq. mm |
| 201 | V. 35 sq. mm |
| 202 | VI. 50 sq. mm |
| 203 | VII. 70 sq. mm |
| 204 | VIII. 95 sq. mm |
| 205 | IX. 120 sq. mm |
| 206 | X. 150 sq. mm |
| 207 | XI. 185 sq. mm |
| 208 | XII. 240 sq. mm |
| 209 | XIII. 300 sq. mm |
| 210 | XIV. 400 sq. mm |
| 211 | XV. 500 sq. mm |
| 212 | XVI. 630 sq. mm |
| 213 | XVII. 800 sq. mm |
| 214 | 1000 sq. mm |
| 215 | E. 4- CoreI. 4 sq. mm |
| 216 | I. 6 sq. mm |
| 217 | II. 10 sq. mm |
| 218 | III. 16 sq. mm |
| 219 | IV. 25 sq. mm |
| 220 | V. 35 sq. mm |
| 221 | VI. 50 sq. mm |
| 222 | VII. 70 sq. mm |
| 223 | VIII. 95 sq. mm |
| 224 | IX. 120 sq. mm |
| 225 | X. 150 sq. mm |
| 226 | XI. 185 sq. mm |
| 227 | XII. 240 sq. mm |
| 228 | XIII. 300 sq. mm |
| 229 | XIV. 400 sq. mm |
| 230 | XV. 500 sq. mm |
| 231 | XVI. 630 sq. mm |
| 232 | XVII. 800 sq. mm |
| 233 | 1000 sq. m |
| 234 | Providing, laying, fixing and commissionning of Armoured cable including proper termination of cables with properly crimped appropriate size. Aluminium thimbles properly taken over existing cable tray/ poles. The job includes all carriages, fitting costs etc. Nothing extra shall be paid.as per latest IS specifications and to be of approved make of cable size:A. Single Corei. 4 sq. mm |
| 235 | i. 6 sq. mm |
| 236 | ii. 10 sq. mm |
| 237 | iii. 16 sq. mm |
| 238 | iv. 25 sq. mm |
| 239 | v. 35 sq. mm |
| 240 | vi. 50 sq. mm |
| 241 | vii. 70 sq. mm |
| 242 | viii. 95 sq. mm |
| 243 | ix. 120 sq. mm |
| 244 | x. 150 sq. mm |
| 245 | xi. 185 sq. mm |
| 246 | xii. 240 sq. mm |
| 247 | xiii. 300 sq. mm |
| 248 | xiv. 400 sq. mm |
| 249 | xv. 500 sq. mm |
| 250 | xvi. 630 sq. mm |
| 251 | xvii. 800 sq. mm |
| 252 | xviii. 1000 sq. mm |
| 253 | B. 2-Corei. 4 sq. mm |
| 254 | i. 6 sq. mm |
| 255 | ii. 10 sq. mm |
| 256 | iii. 16 sq. mm |
| 257 | iv. 25 sq. mm |
| 258 | v. 35 sq. mm |
| 259 | vi. 50 sq. mm |
| 260 | vii. 70 sq. mm |
| 261 | viii. 95 sq. mm |
| 262 | ix. 120 sq. mm |
| 263 | x. 150 sq. mm |
| 264 | xi. 185 sq. mm |
| 265 | xii. 240 sq. mm |
| 266 | xiii. 300 sq. mm |
| 267 | xiv. 400 sq. mm |
| 268 | xv. 500 sq. mm |
| 269 | xvi. 630 sq. mm |
| 270 | xvii. 800 sq. mm |
| 271 | 1000 sq. mm |
| 272 | C. 3- Corei. 4 sq. mm |
| 273 | i. 6 sq. mm |
| 274 | ii. 10 sq. mm |
| 275 | iii. 16 sq. mm |
| 276 | iv. 25 sq. mm |
| 277 | v. 35 sq. mm |
| 278 | vi. 50 sq. mm |
| 279 | vii. 70 sq. mm |
| 280 | viii. 95 sq. mm |
| 281 | ix. 120 sq. mm |
| 282 | x. 150 sq. mm |
| 283 | xi. 185 sq. mm |
| 284 | xii. 240 sq. mm |
| 285 | xiii. 300 sq. mm |
| 286 | xiv. 400 sq. mm |
| 287 | xv. 500 sq. mm |
| 288 | xvi. 630 sq. mm |
| 289 | xvii. 800 sq. mm |
| 290 | 1000 sq. mm |
| 291 | D. 3.5-Corei. 4 sq. mm |
| 292 | i. 6 sq. mm |
| 293 | ii. 10 sq. mm |
| 294 | iii. 16 sq. mm |
| 295 | iv. 25 sq. mm |
| 296 | v. 35 sq. mm |
| 297 | vi. 50 sq. mm |
| 298 | vii. 70 sq. mm |
| 299 | viii. 95 sq. mm |
| 300 | ix. 120 sq. mm |
| 301 | x. 150 sq. mm |
| 302 | xi. 185 sq. mm |
| 303 | xii. 240 sq. mm |
| 304 | xiii. 300 sq. mm |
| 305 | xiv. 400 sq. mm |
| 306 | xv. 500 sq. mm |
| 307 | xvi. 630 sq. mm |
| 308 | xvii. 800 sq. mm |
| 309 | 1000 sq. mm |
| 310 | E. 4- Corei. 4 sq. mm |
| 311 | i. 6 sq. mm |
| 312 | ii. 10 sq. mm |
| 313 | iii. 16 sq. mm |
| 314 | iv. 25 sq. mm |
| 315 | v. 35 sq. mm |
| 316 | vi. 50 sq. mm |
| 317 | vii. 70 sq. mm |
| 318 | viii. 95 sq. mm |
| 319 | ix. 120 sq. mm |
| 320 | x. 150 sq. mm |
| 321 | xi. 185 sq. mm |
| 322 | xii. 240 sq. mm |
| 323 | xiii. 300 sq. mm |
| 324 | xiv. 400 sq. mm |
| 325 | xv. 500 sq. mm |
| 326 | xvi. 630 sq. mm |
| 327 | xvii. 800 sq. mm |
| 328 | 1000 sq. m |
| 329 | Manufacturing, providing, fixing, installation of any number of retro- reflective signage system/ boards as directed by engineer-in-charge of 2 mm thick aluminium alloy highly stressed sheeting plates of different size and specifications having properties of anti- corrosion, weather resistant, colour stability, extreme durability and extreme visibility in all weather conditions in accordance with the international brand complete with computer aided machine process subject matters, logos symbols, borders arrow text size in English/Urdu as directed by engineer-in-charge and graphics by way of cut outs, printing application in green and white colours which includes providing of fancy type metal stanchion upto 300 cm length of 40 mm OD with 90 mm decorative dome shaped top including supporting stiffeners for strengtheningof the job wherever necessary with providing of 15 cm long resting toe plates fitted at bottom for embedding which also includes suitable technical provisions by way of accurate pre-drilled holes to enable anti- theftrivetting system and other necessary allied hardware required for the job and priming / cladding, painting of ISC which also includes installation, erection, hoisting and fixing in position including embedding of signage/ metal stanchion at various locations or site including packing/ carriages, handling/ re-handling/, loading/ unloading, leads/ lifts and head load necessary with tools/ plants and all consumable electric energy gases etc. as and when required for scaffolding as per requirement of site (retro-reflective signages of super-engineering grade with fancy type metal stanchion in structural steel frame and all installation charges, complete in all respects. |
| 330 | Providing and fixing of electrical points (heating and lighting) including cost of wire (1.5mm for lighting and 4mm for heating) switches, necessary MCB’s switch boards, ceiling roses of reputed make ISI mark screws, casing / conduit material of all sorts of carriage and labour charges required for the job.i. Lighting Points |
| 331 | ii. Heating Points |
| 332 | Supply of 20W LED Bulbs ISI make as approved by Engineer Incharge for filtration plant sites etc. |
| 333 | Providing ,fixing and commissioning of Bus bar. The job includes dismantaling of damaged Bus- bar ,all carriages, fitting costs etc. (Complete Job)i. 4-Pole 63A |
| 334 | i. 4-Pole 100A |
| 335 | ii. 4-Pole 200A |
| 336 | iii. 4-Pole 250A |
| 337 | iv. 4-Pole 315A |
| 338 | 4-Pole 400A |
| 339 | Providing ,fixing and commissioning of Change-over . The job includes dismantaling of damaged Change- over ,all carriages, fitting costs etc. (Complete Job)I. 4-pole 200 A |
| 340 | Supply of 9W LED Bulbs ISI make as approved by Engineer Incharge for filtration plant sites etc. |
| 341 | Supply of 50W LED flash lights for filtration plant sites etc. |
| 342 | Repairs to fridge/ defreezer by way of replacement of panel board etc. |
| 343 | Periodic servicing and maintenance of Acs |
| 344 | Periodic servicing / overhauling of 125KVA DG Set |
| 345 | Repairing of water Geyser.a. Heating element ALuminium made |
| 346 | a. Thermostat Autocut |
| 347 | b. Indicator lights |
| 348 | c. 3 pin plug 15 Ampere IS made |
| 349 | d. Copper Wire 2.5mm thick, 2.00Mtr. |
| 350 | e. Gyser bolts 4 No. MS |
| 351 | f. PVC connection length 450mm, 15mm. |
| 352 | Angle valve 15mm if IS make |
| 353 | Repairing of inverter battery & inverter (Complete job) |
| 354 | Supply of distilled water for batteries. |
| 355 | Repair of lawn mover by way of replacement of bearings / belt etc. Complete job. |
| 356 | Refilling of commercial LPG gas excluding cost of gas cylinder. |
| 357 | Repairs to foot valves 150mm dia. (Complete Job) |
| 358 | Supply of various T&P Articlesi. Slippers (Aqualite) |
| 359 | i. Hower wiper (Action ware) |
| 360 | ii. Dust bin 15Ltr. capacity |
| 361 | iii. Dust bin 5Ltr. capacity |
| 362 | iv. Brooms long type |
| 363 | v. Brooms short type |
| 364 | vi. Long boots (water proof) |
| 365 | vii. Rubber pipe 20mm dia |
| 366 | viii. Towel (large size) |
| 367 | ix. Towel (meduim size) |
| 368 | Harpic |
| 369 | i. Colin |
| 370 | ii. Soap 50gm. |
| 371 | iii. Gas regulator |
| 372 | iv. Gas Pipe |
| 373 | v. Waste Pipe for sinks / wash basins. |
| 374 | vi. Bush rods |
| 375 | vii. Mug |
| 376 | viii. Bucket 15Ltr. Capacity |
| 377 | ix. Bucket 5Ltr. Capacity |
| 378 | x. Garden Shear |
| 379 | i. Mirror (looking glass) size 2’-0” x 1’-6” |
| 380 | ii. Showel |
| 381 | iii. Pick axe |
| 382 | Fish net |
| 383 | xxvi. Floating material arrester (with steel net) complete. |
| 384 | i. Rechargeable LED Torch 100W. |
| 385 | ii. Link set for main Stabiliser. |
| 386 | iii. Thimble different sizes. |
| 387 | iv. Transformer oil. |
| 388 | Rubber sheet 8 mm. |
| 389 | i. Room matting with Thermocol. |
| 390 | ii. Paper Rim A4. |
| 391 | iii. Attendance Register. |
| 392 | xxxv. Gauge books,Test report books including proper binding and printing as per engineer incharge all complete job. |
| 393 | i. Water proof uniforms |
| 394 | ii. Rain coats. |
| 395 | iii. Exide Inverter Battery 12V,150Ah. |
| 396 | xxxix. Manual Lawn Mower with grass catcher (14/16 inch dia. Tyre size). |
| 397 | i. Lubricating Oil. |
| 398 | ii. Gear Oil. |
| 399 | iii. Grease. |
| 400 | iv. Digging Fork (Panja). |
| 401 | v. Grease Gun. |
| 402 | xlv. Stainless steel cotter pins (100/150/200 mm long). |
| 403 | i. 35cc 4 stoke bush cutter. |
| 404 | 500V Voltahe Meter |
| 405 | Engagement of JCB cost of POL, Driver. |
| 406 | Providing and fixing of 8mm thick rubber matting on floor of electrical control room. |
| 407 | Providing and fixing of thermocoal foam 10 mm thick for matting of approved make. |
| 408 | Providing and fixing of carpet, excel for matting. |
| 409 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 410 | White washing with lime to give an even shade .i. Old work (two or more coats). |
| 411 | ii. Old work (one or more coats). |
| 412 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 413 | Distempering with dry distemper of approved brand and manufacture (one or more coats) and of required shade on old work to give an even shade. |
| 414 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer. |
| 415 | Applying priming coat: i. With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). |
| 416 | ii. With ready mixed aluminum primer of approved brand and manufacture on resinous wood and ply wood. |
| 417 | iii. With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works. |
| 418 | iv. 4 With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel work (second coat). |
| 419 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 420 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. i. One coat |
| 421 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 422 | Finishing walls with premium Acrylic smooth exterior paint with silicon additives of required shade: i. Old work (Two or more coats applied @ 1.43 liters/ 10 sqm) over existing cement paint surface. |
| 423 | ii. Old work (one or more coats applied @ 0.83 liters/ 10sqm) |
| 424 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc complete i. On steel work |
| 425 | ii. On concrete work |
| 426 | Painting on G.S sheets with synthetic enamel paint of approved band and manufacture of required colour to give an even shade on New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. |
| 427 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 428 | Painting with oil type wood preservative of approved brand and manufacture on old work (one or more coats). |
| 429 | Painting with aluminum paint of approved brand and manufacture to give an even shade, one or more coats on old work. |
| 430 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade, one or more coats on old work. |
| 431 | French spirit polishing, one or more coats on old work. |
| 432 | Floor polishing on masonry or concrete floors with wax polish of approved brand and manufacture. |
| 433 | Melamine polishing on wood work (one or more coats). |
| 434 | Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade on new work Two or more coats. |
| 435 | Lettering with black Japan paint of approved brand and manufacture. |
| 436 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. i. 2 mm thick |
| 437 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 438 | Providing, fixing of M.S flanges by welding including cost of cutting making both holes made out of 10/14mm thick M.S plate to the pipes of different dia’s and including cost of nuts, bolts, washers etc. (Complete Job).i. 80mm dia |
| 439 | i. 100mm dia |
| 440 | ii. 150mm dia |
| 441 | iii. 200mm dia |
| 442 | iv. 250mm dia |
| 443 | v. 300mm dia |
| 444 | vi. 400mm dia |
| 445 | vii. 450mm dia |
| 446 | viii. 500mm dia |
| 447 | ix. 600mm dia |
| 448 | x. 700mm dia |
| 449 | xi. 750mm dia |
| 450 | xii. 800mm dia |
| 451 | 900mm dia |
| 452 | Providing lead caulked joints to spun iron or C.I. pipes and specials including testing of joints but excluding the cost of pig lead. (Subject to actual quantities during execution).i. 100 mm dia. Pipe |
| 453 | i. 125 mm dia. pipe |
| 454 | ii. 150 mm dia. pipe |
| 455 | iii. 200 mm dia. pipe |
| 456 | iv. 250 mm dia. pipe |
| 457 | v. 300 mm dia. pipe |
| 458 | vi. 350 mm dia. pipe |
| 459 | vii. 400 mm dia. Pipe |
| 460 | viii. 450 mm dia. pipe |
| 461 | ix. 500 mm dia. pipe |
| 462 | x. 600 mm dia. Pipe |
| 463 | 700 mm dia Pipe |
| 464 | Supply of fitter / labours. i. Fitter |
| 465 | i. Asstt. Fitter |
| 466 | ii. Labour |
| 467 | iii. Blacksmith Ist Class |
| 468 | iv. Blacksmith 2nd Class |
| 469 | v. Carpenter Ist Class |
| 470 | vi. Carpenter 2nd Class |
| 471 | vii. Technicial |
| 472 | Helper technician |
| 473 | Hire Charges of Plants and Machineries.a. Hire and running charges of Crane 20 Ton Capacity. |
| 474 | b. Hire and running charges of Light Crane |
| 475 | c. Hire charges of Commercial vehicle of loading capacity upto 8 MT including POL alongwith commercial licensed driver.i. Upto 20 Km/Trip |
| 476 | ii. Beyond 20 Km upto 50 Km/Trip |
| 477 | Supply of lead, spun Yarn, Fire Wood Kerosene including all carriages upto site of work.i. Lead |
| 478 | ii. Spun Yarn |
| 479 | iii. Fire Wood |
| 480 | iv. Kerosene |
| 481 | Providing and fixing brass bib cock of approved quality. i. 15 mm nominal bore |
| 482 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) i. 25 mm nominal bore |
| 483 | i. 20 mm nominal bore |
| 484 | ii. 32 mm nominal bore |
| 485 | iii. 40 mm nominal bore |
| 486 | iv. 50 mm nominal bore |
| 487 | v. 65 mm nominal bore |
| 488 | 80 mm nominal bore |
| 489 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete.i. 15 mm nominal bore |
| 490 | i. 20 mm nominal bore |
| 491 | 25 mm nominal bore |
| 492 | Laying in position centrifugally cast (spun) iron S&S or flanged pipes (excluding cost of pipe). |
| 493 | Laying in position S&S or flanged C.I. special such as tees, bends, collars, tapers and caps etc. (excluding cost of specials). |
| 494 | Providing and laying flanged C.I. standard specials such as tees, bends, collars, tapers, caps etc ., suitable for flanged jointing as per IS : 1538 i. Up to 300 mm dia. |
| 495 | ii. Over 300 mm dia |
| 496 | Providing push-on-joints to Centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket. i. 100 mm dia pipes |
| 497 | i. 150 mm dia pipes |
| 498 | ii. 200 mm dia pipes |
| 499 | iii. 250 mm dia pipes |
| 500 | iv. 300 mm dia pipes |
| 501 | v. 350 mm dia pipes |
| 502 | vi. 400 mm dia pipes |
| 503 | vii. 450 mm dia pipes |
| 504 | viii. 500 mm dia pipes |
| 505 | ix. 600 mm dia pipes |
| 506 | x. 650 mm dia pipes |
| 507 | xi. 700 mm dia pipes |
| 508 | xii. 800 mm dia pipes |
| 509 | xiii. 900 mm dia pipes |
| 510 | 1000 mm dia pipes |
| 511 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/by mechanical means including stacking of pipes within 50 meters lead as per direction of Engineer-in-charge : i. 15 mm to 40 mm nominal bore. |
| 512 | ii. Above 40 mm nominal bore |
| 513 | Re-threading of damaged pipe ends including carriage from site to workshop and back.i. 20mm dia |
| 514 | i. 25mm dia |
| 515 | ii. 40mm dia |
| 516 | iii. 50mm dia |
| 517 | iv. 65mm dia |
| 518 | v. 80mm dia |
| 519 | 100mm dia |
| 520 | Supply of pipe specials from open market, if not available in the Divisional stores (available supplies if any has to be lifted from the Divisional Stores). of reputed make.i. 25mm dia GI Union |
| 521 | i. 20mm dia GI Union |
| 522 | ii. 25mm dia GI Elbow |
| 523 | iii. 20mm dia GI Elbow |
| 524 | iv. 25mm dia GI Socket |
| 525 | v. 20mm dia GI Socket |
| 526 | vi. 25mm dia GI Nipple 250mm long |
| 527 | viii. 20mm dia GI Nipple 250mm long |
| 528 | Replacement / supply of PPR gate valves for bleaching / alum tank / foot valves and Prince pipes.i. 20mm dia Gate Valve |
| 529 | i. 25mm dia Gate Valve |
| 530 | ii. 32mm dia Gate Valve |
| 531 | iii. 40mm dia Gate Valve |
| 532 | iv. 50mm dia Gate Valve |
| 533 | v. 20mm dia PVC Pipe (B Class) |
| 534 | vi. 25mm dia PVC Pipe (B Class) |
| 535 | vii. 32mm dia PVC Pipe (B Class) |
| 536 | viii. 40mm dia PVC Pipe (B Class) |
| 537 | 50mm dia PVC Pipe (B Class) |
| 538 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. i. Internal work-exposed on wall with clamps at 1.00 meter spacing a. PN-16 pipe, 16mm OD(SDR-7.4) |
| 539 | a. PN-16 pipe , 20mm OD(SDR-7.4) |
| 540 | b. PN-16 pipe , 25mm OD(SDR-7.4) |
| 541 | c. PN-16 pipe , 32mm OD(SDR-7.4) |
| 542 | d. PN-16 pipe , 40mm OD(SDR-7.4) |
| 543 | e. PN-10 pipe , 50mm OD(SDR-11) |
| 544 | ii. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. a. PN-16 pipe, 16mm OD(SDR-7.4) |
| 545 | a. PN-16 pipe , 20mm OD(SDR-7.4) |
| 546 | b. PN-16 pipe , 25mm OD(SDR-7.4) |
| 547 | PN-16 pipe , 32mm OD(SDR-7.4) |
| 548 | iii. External work including trenching, refilling etc. a. PN-16 pipe, 16mm OD (SDR-7.4) |
| 549 | a. PN-16 pipe , 20mm OD (SDR-7.4) |
| 550 | b. PN-16 pipe , 25mm OD (SDR-7.4) |
| 551 | c. PN-16 pipe , 32mm OD (SDR-7.4) |
| 552 | d. PN-16 pipe, 40mm OD (SDR-7.4) |
| 553 | e. PN-10 pipe , 50mm OD (SDR-11) |
| 554 | f. PN-10 pipe , 63mm OD (SDR-11) |
| 555 | g. PN-10 pipe , 75mm OD (SDR-11) |
| 556 | h. PN-10 pipe , 90mm OD (SDR-11) |
| 557 | i. PN-10 pipe , 110mm OD (SDR-11) |
| 558 | PN-10 pipe , 160mm OD (SDR-11) |
| 559 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. i. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing a. 15mm nominal outer dia pipes. |
| 560 | a. 20mm nominal outer dia pipes. |
| 561 | b. 25mm nominal outer dia pipes. |
| 562 | c. 32mm nominal outer dia pipes. |
| 563 | d. 40mm nominal outer dia pipes. |
| 564 | 50mm nominal outer dia pipes. |
| 565 | ii. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. a. 15mm nominal outer dia pipes. |
| 566 | a. 20mm nominal outer dia pipes. |
| 567 | b. 25mm nominal outer dia pipes. |
| 568 | c. 32mm nominal outer dia pipes. |
| 569 | iii. External work including trenching, refilling etc. a. 15mm nominal outer dia pipes. |
| 570 | a. 20mm nominal outer dia pipes. |
| 571 | b. 25mm nominal outer dia pipes. |
| 572 | c. 32mm nominal outer dia pipes. |
| 573 | d. 40mm nominal outer dia pipes. |
| 574 | e. 50mm nominal outer dia pipes. |
| 575 | f. 62.50mm nominal outer dia pipes. |
| 576 | g. 75mm nominal outer dia pipes. |
| 577 | h. 100mm nominal outer dia pipes. |
| 578 | 150mm nominal outer dia pipes. |
| 579 | Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) Light Class.i. 15 mm dia. nominal bore |
| 580 | i. 20 mm dia. nominal bore |
| 581 | ii. 25 mm dia. nominal bore |
| 582 | iii. 40 mm dia. nominal bore |
| 583 | iv. 50 mm dia. nominal bore |
| 584 | 65 mm dia. nominal bore |
| 585 | Replacement of old damaged G.I. / C.I. Gate Valves / Sluice Valves by providing / fixing of new Gate Valves / Sluice Valves including cost of nuts, bolts,. Rubber insulations all carriages upto site of works complete.i. 100mm dia Gate Valve |
| 586 | i. 80mm dia Gate Valve |
| 587 | ii. 65mm dia Gate Valve |
| 588 | iii. 50mm dia Gate Valve |
| 589 | 40mm dia Gate Valve |
| 590 | Fixing charges of Sluice Valve including testing, commissioning and carriages from Divisional Store to actual site of work, Complete job.i. 900mm dia Butterfly Valve |
| 591 | i. 700mm dia Butterfly Valve |
| 592 | ii. 900mm dia Sluice Valve |
| 593 | iii. 750mm dia Sluice Valve |
| 594 | iv. 700mm dia Sluice Valve |
| 595 | v. 500mm dia Sluice Valve |
| 596 | vi. 450mm dia Sluice Valve |
| 597 | vii. 400mm dia Sluice Valve |
| 598 | viii. 350mm dia Sluice Valve |
| 599 | ix. 300mm dia Sluice Valve |
| 600 | x. 200mm dia Sluice Valve |
| 601 | xi. 150mm dia Sluice Valve |
| 602 | xii. 125mm dia Sluice Valve |
| 603 | xiii. 100mm dia Sluice Valve |
| 604 | xiv. 80mm dia Sluice Valve |
| 605 | 50mm dia Sluice Valve |
| 606 | Filling empty cement bags with sand/ earth; including cost of sewing and strings; excluding cost of bags and earth / sand. |
| 607 | Loading/Unloading sand/ earth filled bags in lorries; lead upto 50m. |
| 608 | Supplying and stacking at site. Good Earth |
| 609 | Hand-packing stones in wire-crates; excluding cost of crates and stones |
| 610 | Extra for every additional lift of 1.5 m or part there of beyond 1.5 m height for hand-packing of stones in wire-crates. |
| 611 | Dumping stone excluding cost of stones. i. in Horizontal on level. |
| 612 | Making knitted wire crates of approved mesh-size; including weaving, binding sides and partitions, and binding top after filling; excluding cost of filling, stones and weaving materials. |
| 613 | Tipping stone-filled wire crates in position; including equipment charges. |
| 614 | Silt clearance from canals. Inclusive of initial lead and lift ( 50m & 1.5m respectively )i. Dry |
| 615 | ii. Wet |
| 616 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) i. For fixed portion a. Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 617 | b. Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 618 | c. Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns) |
| 619 | ii. For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) a. Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) |
| 620 | b. Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 621 | c. Polyester powder coated aluminum (minimum thickness of polyester powder coated 50 microns) |
| 622 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.) i. With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm). |
| 623 | ii. With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm). |
| 624 | iii. With float glass panes of 8 mm thickness (weight not less than 20.0 kg / sqm) |
| 625 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in- charge etc. complete as per the direction of Engineer-in-chargei. With Stainless Steel cover plate minimum 1.25 mm thickness. |
| 626 | ii. With brass cover plate minimum 1.25 mm thickness |
| 627 | Filling the gap in between aluminum frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. i. Upto 5mm depth and 5mm width |
| 628 | Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminum extruded sections. i. For fixed portions |
| 629 | ii. Shutters of doors, windows and ventilators |
| 630 | Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. |
| 631 | Providing and fixing aluminum round shape handle of outer dia 100mm with SS screws etc. Complete as per direction of Engineer-in-charge.i. Anodized (AC 15) aluminum |
| 632 | ii. Powder coated minimum thickness 50 micron aluminum |
| 633 | iii. Polyester powder coated minimum thickness 50 microns aluminum |
| 634 | Providing and fixing Anodized aluminum grill (Anodized transparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved Anodized aluminum standard section around the opening, all complete as epr requirement and direction of Engineer-in-charge. (only weight of grill to be measured for payment). |
| 635 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot &double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 636 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer -in- Charge. |
| 637 | Carriage of earth from source to dumping site of work including loading, unloading and stacking etc. complete by mechanical transport.a. Earth avg. lead upto 1Kms |
| 638 | a. Earth avg. lead upto 2Kms |
| 639 | b. Earth avg. lead upto 3Kms |
| 640 | c. Earth avg. lead upto 4Kms |
| 641 | d. Earth avg. lead upto 5Kms |
| 642 | f. Earth avg. lead upto 5Kms upto 10Kms (per Km) |
| 643 | g. Earth avg. lead upto 10Kms upto 20Kms (per Km) |
| 644 | h. Earth avg. lead upto 20Kms upto 10Kms (per additional Km) |
| 645 | Carriage of material from divisional store upto dumping site of work including loading, unloading and stacking etc. complete by mechanical transport.a. Cement & Steel, GI/CI Pipe avg. lead upto 1Kms. |
| 646 | b. Cement & Steel, GI/CI Pipe avg. lead upto 2Kms. |
| 647 | c. Cement & Steel, GI/CI Pipe avg. lead upto 3Kms. |
| 648 | d. Cement & Steel, GI/CI Pipe avg. lead upto 4Kms. |
| 649 | e. Cement & Steel, GI/CI Pipe avg. lead upto 5Kms. |
| 650 | f. Cement & Steel, GI/CI Pipe beyond 5Kms upto 10Kms (per Km). |
| 651 | g. Cement & Steel, GI/CI Pipe beyond 10Kms upto 20Kms (per Km) |
| 652 | h. Cement & Steel, GI/CI Pipe beyond 20Kms. |
| 653 | Carriage of material from different sources upto dumping site of work including loading, unloading and stacking etc. complete by mechanical transport.a. Sand and Agg., 20 mm av. lead upto 1Kms |
| 654 | a. Sand and Agg., 20 mm av. lead upto 2Kms |
| 655 | b. Sand and Agg., 20 mm av. lead upto 3Kms |
| 656 | c. Sand and Agg., 20 mm av. lead upto 4Kms |
| 657 | d. Sand and Agg., 20 mm av. lead upto 5Kms |
| 658 | f. Sand and Agg., 20 mm beyond 5Kms upto 10Kms. (Per Km). |
| 659 | g. Sand and Agg., 20 mm beyond 10Kms upto 20Kms. (Per Km). |
| 660 | a. Sand and Agg., 20 mm av. lead upto 20Kms |
| 661 | b. 40 mm Agg., lead upto 1Km. |
| 662 | c. 40 mm Agg., lead upto 2Km. |
| 663 | d. 40 mm Agg., lead upto 3Km. |
| 664 | e. 40 mm Agg., lead upto 4Km. |
| 665 | f. 40 mm Agg., lead upto 5Km. |
| 666 | n. 40 mm Agg., av. lead beyond 5Kms upto 10Kms (per Km). |
| 667 | o. 40 mm Agg., av. lead beyond 10Kms upto 20Kms (per Km). |
| 668 | p. 40 mm Agg., av. lead beyond 20Kms (per Km). |
| 669 | a. Stone soling av. lead upto 1Kms |
| 670 | b. Stone soling av. lead upto 2Kms |
| 671 | c. Stone soling av. lead upto 3 Kms |
| 672 | d. Stone soling av. lead upto 4Kms |
| 673 | e. Stone soling av. lead upto 5Kms |
| 674 | v. Stone soling av. lead beyond 5Kms upto 10Kms (per Km) |
| 675 | w. Stone soling av. lead beyond 10Kms upto 20Kms (per Km). |
| 676 | x. Stone soling av. lead beyond 20Kms (per Km) |
| 677 | Carriage of material from dumping site to actual site of work, including loading, unloading and stacking etc. complete by manual labour.a. Cement for an Avg. lead upto 50m |
| 678 | b. Cement for an every additional lead of 50m or part thereof beyond Ist 50m |
| 679 | c. Steel for an Avg. lead upto 50m |
| 680 | d. Steel for an every additional lead of 50m or part thereof beyond Ist 50m |
| 681 | e. Pipe for an Avg. lead upto 50m |
| 682 | f. Pipe for an every additional lead of 50m or part thereof beyond Ist 50m |
| 683 | g. Soling for an Avg. lead upto 50m |
| 684 | h. Soling for an every additional lead of 50m or part thereof beyond Ist 50m. |
| 685 | i. Sand and Agg. 20mm for an Avg. lead upto 50m |
| 686 | j. Sand and Agg. 20mm for an Avg. lead upto 50m or part thereof beyond Ist 50m. |
| 687 | k. 40mm Agg. for an avg. lead of 50m or part therefore of beyond Ist 50m. |
| 688 | l. 40mm Agg. for every additional lead of 50m or part therefore of beyond Ist 50m. |
| 689 | Providing refreshment to supervisory staff & departmental labour for prolonged/continuous operation of repair/ restoration/ maintenance work of pipelines. Complete job including packing with following Menu.i. Water Bottle One litre |
| 690 | i. Water Bottle 500 ml |
| 691 | Water bollte 250 ml |
| 692 | iv. Juice pac/ tin 100 ml to 180 ml of Standard Quality |
| 693 | i. Boiled Egg/Omelete |
| 694 | ii. Biscuit standard Quality of 50g |
| 695 | iii. Banana |
| 696 | iv. Butter Toastes each pair |
| 697 | v. Toastes without Butter each pair |
| 698 | vi. Tea Sugar each Cup |
| 699 | Tea Namkeen each Cup |
| 700 | xii. Normal Chicken Biryani one plate for each person |
| 701 | xiii. Rice Plate with vegetables Single piece meat for each person |
| 702 | Supply of guage / chemical test report / bed washing books etc. of required format with 100leaves each in triplicate including binding. |
| 703 | Repairs to the rotatory wheel of the clarifloculator bridge by way of raising the bridge on the hydraulic jacking arrangement, replacement of the worn-out wheel bearings and nuts of the assembly, depositing of the cast iron metal if required on the cups /base of the wheel bearing or shaft rod /axle rod, welding of the unit if required testing and commissioning after completion of work with all carriages and head load all complete. |
| 704 | Loading in or unloading chemicals (Alum or Bleaching) by manual means from trenches and carrying the same into chemical store including stacking the same properly in rows upto any height as per the clarification of Incharge Incharge, sweeping the vehicles/floor. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail