| 1 | 2.2 Clearing and Grubbing Road LandClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees having girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness.A In area of light jungle |
| 2 | 3.3 Excavation in Soil using Hydraulic Excavator and Tippers with disposal up to 1000 meters.Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting suitable earth to the embankment location and disposing off unsuitable earth with all lifts and lead up to 1000m as per relevant clauses of section-300 of specification. |
| 3 | 3.13 Embankment/ Sub Grade Construction with Material Obtained from Borrow PitsConstruction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevant clauses of section-300. |
| 4 | 3.14 Construction of Embankment with Material Deposited from Roadway CuttingConstruction of embankment with approved materials having CBR>7 deposited at site from roadway cutting and excavation from drain or foundation of structures graded and compacted to meet requirement of table 300-1, 300-2 and as per relevant clauses of section-300. |
| 5 | 3.18 Surface Drains in SoilConstruction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions to the requirement of clause 301 and 309. Suitable Excavated material to be used in embankment within a lead of 50 meters as per relevant clauses of section-300. |
| 6 | 4.2 Crusher Run Macadam Sub Base/Base CourseProviding crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller as per clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications.(ii) For 37.5 mm maximum size |
| 7 | 4.3 Wet Mix MacadamProviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mixplant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13 and as per clause of section 406 of specifications.A By Sensor Paver |
| 8 | 4.16 Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting on OMC using vibratory roller of 80 to 100 kN static weight. Field compaction shall be done in corresponding layers of carriage way thickness and meet the requirements of MDD to achieve compaction (98% -100%) as per relevant clause of 408.A Hard Shoulders (CBR value >12) |
| 9 | 5.1 Prime Coat Over WMM/WBMProviding and applying primer coat with catonic bitumen emulsion on prepared surface of granular Base including cleaning of road surface and spraying primer at the rate of 0.70 to 1.00 kg/sqm using mechanical means as per clause 502 of specifications. |
| 10 | Providing and applying tack coat with cationic bitumen emulsion using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications.(ii) @0.30 kg per sqm (dry & hungry bituminous surfaces /Granular surfaces treated with primer) |
| 11 | 5.5 Bituminous MacadamProviding and laying bituminous macadam using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with Electronic Sensor paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction and as per clause 504 of specifications.b) Using Drum Mix Plant of appropriate capacity and paver finisher.(ii) for Grading (19 mm nominal size) bitumen content 3.5% with bitumen 60/70 (VG 30) |
| 12 | 5.9 Open - Graded Premix SurfacingProviding, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tone capacity, finished to required level and grades all complete as per clause 510 of specification.(i) Case - I: Mechanical method using Penetration grade Bitumen VG 30 and HMP of appropriate capacity not less than 75 tones/hour. |
| 13 | 5.11 Seal CoatProviding and laying seal coat, sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats, all complete as per clause 511 of Specification.(ii) Case - II: Type B (Providing and laying of premix sand seal coat using HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping (aggregate shall pass 2.36mm sieve and retained to 180-micron sieve) and penetration bitumen VG 30 of suitable grade all complete as per clause 511 of specification. |
| 14 | 8.4 Retro- reflectorised Traffic signsProviding and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2022 clause 6.7.4.3 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT&H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame ofiv) 60 cm equilateral triangle |
| 15 | viii) 60 cm circular |
| 16 | x) 80 cm x 60 cm rectangular |
| 17 | xii) 60 cm x 45 cm rectangular |
| 18 | xiii) 60 cm x 60 cm square |
| 19 | 8.9 Direction and Place Identification signs more than 0.9 sqm size board. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC:67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thickskins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8of the IRC 67-2012 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on 2 nos. of MS sign post of size 100 x100 x 3mm Square Pipe of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25x50x1.25mm tubular frame with the help of suitable sizes pop rivettes of 6mm or by the help of G I / Nickle Chome plated nut & bolts to be hammered after tightening. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. |
| 20 | 8.35 Cable Duct Across the RoadProviding and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-2011, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 2011 and approved drawings.Single Row for one utility service |
| 21 | 8.36 Kilo Metre StoneReinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc(ii) Ordinary Kilometer stone (Precast) |
| 22 | (iii) Hectometer stone (Precast) |
| 23 | 8.38 Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beeds on Bituminous surface.Providing and applying (Cleaning of Bituminous surface) thermoplastic compound having composition of binder (Resin) minimum 18 %, titanium dioxide minimum 10 % and intermixed glass beed, minimum 30% of brand like Asian, Burger or equivalent make of 2.5 mm thick including drop down reflectorizing, glass beeds @ 250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beeds as per IRC:35.The finished surface to be level, uniform and free from streaks and holes, all complete as per clause 803 of specifications. |
| 24 | 9.1 PCC M-15 in FoundationPlain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409. |
| 25 | 9.2 Providing and Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.B 1000 mm dia |
| 26 | 9.3 Providing and Laying Reinforced Cement Concrete Pipe NP 4 /prestrssed concrete pipe on first class bedding in double row. Providing and Laying Reinforced cement concrete pipe NP4 /prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.B 1000 mm dia |
| 27 | 9.8 Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900. |
| 28 | 12.1 Excavation for StructuresEarth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per relevant clauses of section 300 & 2100 inI Ordinary soil (including back filling with approved material)(i) Depth upto 3 m |
| 29 | II Ordinary rock (not requiring blasting)(i) Depth upto 3 m |
| 30 | 12.2 Add extra as follows in the rates of the above items if dewatering is resorted toa) upto 3 m depth |
| 31 | b) beyond 3 m to 6 m depth |
| 32 | 12.3 Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100. |
| 33 | 12.6 Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with.(i) Concrete with plant (Drum Type) and placingA PCC Grade M15 |
| 34 | 12.6 Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with.(i) Concrete with plant (Drum Type) and placingB PCC Grade M20 |
| 35 | 13.1 Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specificationsB PCC Grade M20Concrete with plant (Drum Type) and placing |
| 36 | 13.1 Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specificationsA PCC Grade M15Concrete with plant (Drum Type) and placing |
| 37 | 13.1 Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specificationsC PCC Grade M25Concrete with plant (Drum Type) and placing1 Height up to 5 m |
| 38 | 13.4 Supplying, fitting and placing HYSD bar reinforcement in sub- structure complete as per drawing and technical specifications and as per relevant clause of section 1600.FE 500 |
| 39 | 13.7 Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications. |
| 40 | 13.8 Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification and as per relevant clauses 305 of specifications and as per appendix 6 ofIRC-78.A Granular material |
| 41 | 13.16 Providing and fixing in position bituminous paper bearing for slabs as per approved drawing and confirming to IS:1398. |
| 42 | 14.1 Providing and Placing Reinforced/Prestressed cement concrete in super-structure e/x reinforcement as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 inB RCC Grade M25Concrete with plant (Drum Type) and placing1 Height up to 5 m |
| 43 | 14.11 Providing and laying Cement concrete wearing coat 75 mm thick with M-30 grade concrete with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 19 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with static paver, spread, compacted and finished with power trowel in a continuous operation including provision of admixtures as approved, curing compound, finishing to lines and grades as per drawing but including cost of steel etc. including reinforcement, texuring with texuring brush complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications. |
| 44 | 14.4 Supplying, fitting and placing HYSD bars reinforcement in super- structure complete as per confirming to IS 1786:2000 drawing and technical specifications as per relevant clauses of section 1600(i) FE 500 Please Enable Macros to View BoQ information |