Name of Work:- CONSTRUCTION OF PARTITION WALL AT RAIN BASERA IN BUS STAND AND AT FIRE STATION, CHIRAWA
Sl. No.
Item Description
1
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
2
Providing and fixing aluminiumcomposite pannel of approved make 3 mm thick with 0.5 mm thick skin & PVDF coated approved shade for wall panelling. Main framing work to be done using 50mmX25mmX1.6mm tubular section of approved make. Stainless steel screw to be used to fix the ACP panel to be fixed to the main fame with industrial adhesive tape and panel groove to be sealed with weather proof silicon sealent suitable for glass/ aluminimum etc. Complete in all respect as approved by Engineer in Charge. PWD BSR 16.55
3
Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00mm thick with zinc coating not less than 275gm/m²
4
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.