|
| 1 | Operation and maintenance of Electrical and Mechanical installations | Operation and maintenance of Electrical and Mechanical installations of operational and non operational areas including Terminal buildling, ATS Building, Fire station, Electrical Substation and other ancillary buildings for round the clock operation on all days including Sundays and Holidays by engaging following manpower along with providing required tool and consumables as specified in special conditions of contract for day to day maintenance except spares. The job includes preventive, routine maintenance, attending complaint or fault or breakdown by taking rectification actionensuring serviceability and satisfactory working condition of the system, maintaining all records and documentation etc. complete as per agreement conditions and as per the instruction of EIC.1. Supervisor (Highly Skilled) - 01 no.2. Document Assistant (Highly Skilled) - 01 no.3. Wireman (Skilled) - 07 nos.4. Semi-skilled- 06 nos.5. Helper (Unskilled) - 03 nos.(The above manpower is excluding reliever) |
| 2 | Job contract for Operation and Day to Day Maintenance Services of Airport Systems equipments | Job contract for Operation and Day to Day Maintenance Services of Airport Systems equipments including SCCTV Camera System, FIDS , PA System, HHMD, DFMD, Security Equipments, BDDS equipments, XBIS machines, ETD Equipment etc. installed at terminal building, ancillary building at Rupsi Airport. Job also includes attending faults / breakdowns rectifications, ensuring serviceability / satisfactory working condition of the systems, providing registers and log books as per formats given in tender document and maintenance of daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis, registers and log books and coordination with OEM Technicians during CMC works etc. by deploying following manpowers as per scope of work given in special conditions of contract shall be ensured round the clock (ie. in one shifts basis) on all days including Sundays & National Holidays as per direction of EIC and as per attached Annexure-A of ATC. 1. Supervisor (High skilled) -01 no. 2. Technician ( Skilled) -01 no. (The above manpower is excluding reliever) |
| 3 | Execution of item of Schedule of rates CPWD DSR 2022 as and when required | Execution of item of Schedule of rates CPWD DSR 2022 as and when required for attending breakdown, repair and maintenance and upkeep of internal & external electrical installations as per direction of E-I-C at different locations of operational and non operational area i/c Terminal Building, ATS Building, Fire Station, Electrical substation and other ancillary buildings etc. The bidder shall quote the rate in INR only including price escalation for 01 year for the job corresponding to an amount of Rs. 1,00,000.00 (including GST from DSR 2022 items) and percentage (%) above/below shall be calculated by AAI and paid accordingly. |
| 4 | Testing of Transformer oil sample including conducting BDV test and submission of test report etc complete as required | Testing of Transformer oil sample including conducting BDV test and submission of test report etc.complete as required |
| 5 | Filtration of Transformer oil of 630 kVA transformer | Filtration of Transformer oil of 630 kVA transformer to attain acceptable di-electric strength by hot streamline process including arrangement of plant/machine, transportation etc. complete as required by topping of Transformer oil and BDV testing including submission of test reports before & after dehydration of oil. (excluding cost of Transformer oil) (Item is to be executed if the BDV value of transformer oil is found below the stipulated value). |
| 6 | Servicing and Checking of LT Air Circuit Breaker | Servicing & Checking of LT Air Circuit Breaker (ACB) of L&T U POWER OMEGA make by deploying Authorised Service Personnel of Manufacturer/ OEMs Service Dealers as per OEMs standards complete as required and submission of service reports. |
| 7 | Servicing and Checking of HT Vacuum Circuit Breaker | Servicing & Checking of HT Vacuum Circuit Breaker (VCB) of Siemens make by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of service reports. |
| 8 | Calibration and testing of relays at HT Panel | Calibration and testing of following relays at HT Panel by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of service reports.i) Vamp 57 - 5 Nos. (Numerical type of Schneider Make)ii) VAJH13 - 5 Nos. (Tripping Relay of Alstom Make)iii) VAX31 - 5 Nos. (Trip Circuit Supervision Relay of Alstom Make)iv) VAA33 - 4 Nos. (Auxiliary Relay of Alstom Make) |
| 9 | Calibration and testing of following relays at LT and Synchronizing Panel | Calibration and testing of following relays at LT & Synchronizing Panel by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of service reports.i) VAJH13 - 2 Nos. (Tripping Relay of Alstom Make)ii) VAX31 - 2 Nos. (Trip Circuit Supervision Relay of Alstom Make)iii) CCUM21PF112A - 2 Nos. (Definite Time Reverse Power Relay of Areva Make)iv) CAG14AF15A - 2 Nos. (Instantaneous Earth fault Relayof Alstom Make) |
| 10 | Scrubbing, cleaning the existing surface of cubicle panel, feeder pillars and painting | Scrubbing, cleaning the existing surface of cubicle panel, feeder pillars & painting the same with one coat of primer and one coat of synthetic enamel paint of approved colour etc. complete as required |
| 11 | Lettering of maximum 2 inch size Alphabetic or numerical | Lettering of maximum 2inc size (Alphabetic / numerical) on the finished painted surface of feeder pillar / panel / earth pits with synthetic enamel paint of approved colour etc. complete as required. |
| 12 | Cleaning the surface of MS chequered plates | Cleaning the surface of MS chequered plates and painting with one coat of primer and two coats of synthetic enamel black paint etc. complete as required. |
| 13 | Supply and replacement of silica gel in breather of existing 630 KVA transformer etc. complete as required | Supply and replacement of silica gel in breather of existing 630 KVA transformer etc. complete as required |
| 14 | Lifting and lowering of 10 HP borewell submersible motor pump set | Lifting and lowering of 10 HP borewell submersible motor pump set along with dismantling of complete delivery pipeline, removal of pump sets, disconnection of flexible submersible cable, reassembling of submersible pump, complete delivery pipeline, fixing / laying of existing submersible cable including electrical connection, testing and commissioning etc. complete as required. |
| 15 | Servicing and complete overhauling of 10 HP borewell submersible motor pump set | Servicing and complete overhauling of 10 HP borewell submersible motor pump set including replacement of defective bearing, coupling, impellar, mechanical & oil seal, heat varnishing of motor etc. complete as required |
| 16 | Decoration of Terminal Building and Canopy of Rupsi Airport | Decoration of Terminal Building and Canopy of Rupsi Airport, in Tri-Colour, with the following lighting items of pattern approved by E-i-C or his authorized representative, for 03 days etc. complete as required.i) 60 nos. LED series lighting chain (minimum chain length 5m and uniform spacing between chains not more than 0.75 m)ii) 20 nos. RGB LED Facade/ Disco/ Flood light fittings (minimum 10000 lumen output) |
| 17 | Supply and replacement of defective smoke detectors | Supply and replacement of defective smoke detectors of suitable make & model compatible to theexisting system. |
| 18 | Supply and replacement of defective manual call point | Supply and replacement of defective manual call point of suitable make & model compatible to the existing system |
| 19 | Supply of convertor or driver suitable for PHILIPS make 20 W downlight types LED luminaires or fittings | i) PHILIPS make 20 W downlight Type DN195B LED20S |
| 20 | Supply of convertor or driver suitable for OSRAM make 120W types LED luminaires or fittings | ii) OSRAM make 120W Type. LEDENVO LED Street Light |
| 21 | Supply of convertor or driver suitable for HAVELLS make 18 or 20 W downlight types LED luminaires or fittings | iii) HAVELLS make 18/20 W downlight |
| 22 | Supply of convertor or driver suitable for WIPRO make 36W 2ftx2ft recess mounted fitting | iv) WIPRO make 36W 2ftx2ft recess mounted fitting |
| 23 | Supply of 1000W 240V Lamp suitable for Aerodrome Beacon | Supply of 1000W , 240V Lamp suitable for Aerodrome Beacon of model AB-1000F Make- Manairco Inc as and when required. |
| 24 | Supply of Aerodrome Beacon | Supply of Aerodrome Beacon of model AB-1000F Make- Manairco Inc as and when required. |
| 25 | Calibration of Clinometer | Calibration of Clinometer from Govt. Test laboratory/ OEM, submission of test report etc., complete as required i/c taking the equipment from AAIs site to laboratory and bringing back the same from laboratory to AAIs site. |
| 26 | Supply of reflector suitable for AMA make PAPI | Supply of reflector suitable for AMA make PAPI fittings as and when required. |
| 27 | Supply of 2C x 4 sq mm. Secondary lead with Plug | Supply of 2C x 4 sq mm. Secondary lead with Plug at one end of standard length of 5 m as and when required |
| 28 | Supply of B connector or four way porcelain terminal | Supply of B - connector / four-way porcelain terminal for AMA make PAPI units as and when required |
| 29 | Supply of 5 kV grade 50 Hz AC Isolating Transformer | Supply of following rating 5 kV grade, 50 Hz AC Isolating Transformer, series type, encapsuled inpolyster resin, finally moulded in neoprene type rubber with primary and secondary leads, confirming to latest specifications as required suitable for airfield lighting applications etc. as and when required. 200 Watt, 6.6/6.6 Amp. |
| 30 | Supply of two pin halogen lamp Holder suitable for 200 Watt | Supply of two pin halogen lamp Holder suitable for 200 Watt, 6.6 Amp Lamp as and when required. |
| 31 | Supply of 5 W Screw Cap LED lamp | Supply of 5 W Screw Cap LED lamp suitable for Landing T , efficacy not less than 100 lm/W as and when required. |
| 32 | Supply of Wind Sock Cloth | Supply of Wind Sock Cloth, 13 ft 9 inch length, colour preferably Orange & White and conforming to ICAO Annex-14 as and when required. |
| 33 | Supply and replacement of LED flood light | Supply and replacement of LED flood light for mounting on Wind Direction Indicator, equivalent to Philips make Model BVP132LED16/CW 20W 100-240V WB IN as and when required. |
| 34 | Supply and replacement of Obstruction Light of Wind Direction Indicator | Supply and replacement of Obstruction Light of Wind Direction Indicator as and when required. |
| 35 | Supply and replacement of 180 AH 12 V Lead Acid battery | Supply and replacement of 180 AH 12 V Lead-Acid battery, conforming to IS 14257 1995 with up to date amendments, suitable for high cranking performance of 400 kVA DG set as and when required. |
| 36 | Supply and replacement of 100 AH 12 V Lead Acid battery | Supply and replacement of 100 AH 12 V Lead-Acid battery, conforming to IS 14257 1995 with up to date amendments, suitable for high cranking performance of 62.5 kVA DG set as and when required |
| 37 | Supply of Automaic Electric Hand drier | Supply of Automaic Electric Hand drier of following specifications or equivalentMake OMCO, Model IPX1,Voltage-220-240V, Power 1800W |
| 38 | Servicing, Checking Repairing Overhauling and Testing of CROMPTON make 630 KVA Transformer | Servicing, Checking, Repairing, Overhauling and Testing of CROMPTON make 630 KVA, 11/0.433 KV Transformer including carrying out the following tests by deploying Authorised Service Personnel of Manufacturer/OEMs Service Dealers as per OEMs standards complete as required and submission of reports.a) General inspectionb) IR value test primary to secondary, primary to earth, secondary to earthc) Votage ratio check at all tap position,d) Buchholz relay operatione) OTI operationf) WTI operationg) On-Load Tap changer operation checkh) Cleaning of transformer and replacement of silica geli) Acidity Check test of Transformer Oil. |