| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including dressing of sides and ramming of bottom disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. (No extra lift is payable if work is done by mechanical means) All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level : With 20mm nominal size graded stone aggregate. M-10 Nominal (Mix-1 Cement : 3 sand : 6 graded stone aggregate ) |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for concrete upto plinth level |
| 4 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Walls (any thickness) in cluding attached pilasters butter esses, plinth beams and string courses etc. Uptoplinthlevel. |
| 5 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Lintels, beams, girders, bressumers and cantilevers |
| 6 | Centering and shuttering in cluding strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. |
| 7 | Providing and laying in position specified grade of reinforced cement concrete (with 20mm nominal size graded stone aggregate) excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : M-20 Grade Concrete |
| 8 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding including cost of binding wire all wastages and overlaps, couplers (overlaps shall be provided as per requirement of IS 13920 for ductile detaling IS-456 RCC Design & SP 34 Reinforcement detailing ) etc. complete .(Note:-1. Spacer bars (chairs) shall be paid separately as shown in the drawing and as per direction of engineer in charge.2. No extra payment shall be done for overlaps and/or couplers.3. Couplers shall be conforming to IS code on “Reinforcement Couplers for Mechanical Splices of Bars for Concrete Reinforcement - Specification”) Thermo-Mechanically Treated bars. FE 500 conforming to IS 1786 |
| 9 | Filling available excavated earth (excluding hard rock/Ordinary rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 10 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 sand) |
| 11 | Neat cement Punning |
| 12 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 13 | Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality Heavy duty D - 20 Circular shape 560 mm internal diameter |
| 14 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. External work : including trenching and refilling etc. 80 mm dia. nominal bore |
| 15 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. External work : including trenching and refilling etc. 50 mm dia. nominal bore |
| 16 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. External work : including trenching and refilling etc. 40 mm dia. nominal bore |
| 17 | Providing fixing, including testing and commissioning the following size of flanged type sluice valve of cast iron body and bronze/ gun metal seat confirming to class PN 1.6 of IS: 14846/IS: 780 complete with bolts and nuts, rubber insertions etc. as per specification complete as required. 80mm dia |
| 18 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore |
| 19 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore |
| 20 | Providing and fixing G. I. Union in G.I. Pipe line including cutting threading testing etc. complete (New work) conforming to IS 1879 80 mm diameter pipe |
| 21 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 50mm nominal bore |
| 22 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40mm nominal bore |
| 23 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design With flyash bricks of 50 kg/cm2 strength |
| 24 | Supplying & installation of approved make required capacity 3 phase, 50 Hz, 415V, centrifugal mono-block pump, with starter i/c single phase preventer, connections, base channel foundation etc. as required as per specifications but excluding pipe and connection cable. 10.0 HP head metre 10-36, discharge LPM 2400-1200 |
| 25 | Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make. 4.0 sq.mm multi strand |
| 26 | Providing & Fixing 1.25\\" RAIN Gun Complete Set With 0-360 degree Adjustable, 40 mtr (Radius) Range, Suitable Adapter, CLAMP, FOOTBATTEN, 4FT Riser Pipe, 4 Leg Height Adjustable Stand, Rubber Washer and Endcap, All complete as per direction of engineer incharge. Please Enable Macros to View BoQ information |