| 1 | Supply , Installation, Testing and Commissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. Min 5 year Original Equipment Manufacturer (OEM) warranty of both compressor and Printed Circuit Board (PCB). |
| 2 | Cooling capacity 5000-5300 Watt, ISEER not less then 3.8 |
| 3 | Supply , Installation, Testing and Comissioning of Window type Air conditioners as per BEE star rating complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 230 V +/- 10% with low & high voltage cutoff and 50 Hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation R-32/R-410 Green Refrigerant with Scroll / rotary compressor complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. |
| 4 | Cooling capacity 4900 Watt, ISEER not less then 3.1 |
| 5 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. |
| 6 | 25 mm |
| 7 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. |
| 8 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. |
| 9 | Short point (up to 3 mtr.) |
| 10 | Medium point (up to 6 mtr.) |
| 11 | Long point (up to 10 mtr.) |
| 12 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 13 | On board |
| 14 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. |
| 15 | 20 mm |
| 16 | 25 mm |
| 17 | Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with socket,elbow,tee, flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect. ( If Pipe Laid Underground Excavation and refilling cost will be paid extra) |
| 18 | 32mm dia |
| 19 | 40 mm dia. |
| 20 | 50 mm dia. |
| 21 | SITC of Copper Bonded rod Earthing with high tensile strength (more than 600 N / sq.mm low carbon steel rod molecularly bonded with Copper thickness (250 microns) and confirming to UL 467 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- |
| 22 | (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole |
| 23 | (b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 25 kg for 3000 mm. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC 62561-7 |
| 24 | © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt |
| 25 | (d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. |
| 26 | (e) Testing of earth resistance for value of 5 ohms or less as required. |
| 27 | (f) Test certificates for confirming above standards from OEM is mandatory. |
| 28 | 17.2 mm thick and 3 Mtr. Long |
| 29 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. |
| 30 | 10 SWG G.I. ( Hot Dipped ) Wire |
| 31 | Supply, installation, testing & commissioning of following size & Material Lightning protection system accessories meeting requirement of IS/IEC 62305 and tested as per IEC 62561-2 / IS 18925 (Part 1-7) : 2025 as required. |
| 32 | SS 304 Solid round conductor 10 mm dia. |
| 33 | Alluminium alloy Vertical Air termination 16/10 mm with base mounted on 5000 mm 56/40 mm GI pipe as mast |
| 34 | SS 304 clamp connector for 8/10 mm round conductor on metal structure |
| 35 | Lightning Surge Counter designed to record and display lightning strike events. The counter shall feature a 3 digit LCD screen (0-999 events) for clear event tracking and operate on a battery powered system. |
| 36 | Hire charges for Silent type D.G. Set, including change over switch. Control panel, 2 No. Pipe earthing etc. and excluding POL with skilled operator to operate system as and when etc as required. of following capacity: |
| 37 | 62.5 KVA |
| 38 | for 1st day |
| 39 | From 2nd day onwards |
| 40 | 125 KVA |
| 41 | for 1st day |
| 42 | From 2nd day onwards |
| 43 | Hire charges of Main service line for 3 phase connection upto 50 mtr. Length (without any joint) including meter board, panel/distribution Board and supports with skilled operator to operate system as and when etc as required. |
| 44 | above 25.0 sq.mm & upto 95 Sq.mm PVC insulated and Sheathed cable aluminium Armoured or Un-armoured as required.) |
| 45 | for 1st week |
| 46 | For 2nd / 3rd day |
| 47 | from 4th Day onwards |
| 48 | Supply and filling of POL for DG sets |
| 49 | Hire charges for LED Flood light luminaire ( white or warm white as required )for 90- 150 watt with the standard housing ,pole & mounting accessories with wiring, connection with skilled operator to operate system etc. as and when required. |
| 50 | With suitable pole |
| 51 | for 1st day |
| 52 | For 2nd / 3rd day |
| 53 | from 4th Day onwards |
| 54 | Without suitable pole |
| 55 | for 1st day |
| 56 | For 2nd / 3rd day |
| 57 | from 4th Day onwards |
| 58 | Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day ) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India |
| 59 | Pump Operator, AC Plant Operator, ELV System Operator, Lift Operator, DG set Operator or any other services operator with experience of 3 years in relevant field ) |
| 60 | Technical Helper Having basic Knowledge of E&M Services |
| 61 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia |
| 62 | 50 mm dia per running inch length Please Enable Macros to View BoQ information |