| 1 | Civil Work |
| 2 | Providing & Laying of Tactile Flooring and Friendly Handrail & Grab Rails |
| 3 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation |
| 4 | Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type |
| 5 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 6 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 7 | Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material) |
| 8 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints(Tile design and pattern will be as per guidelines issued for persons with disability). |
| 9 | 12.5 mm thick cement plaster 1:4 |
| 10 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 11 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 12 | Disposal of Malwa |
| 13 | Providing & fixing 16 gauge stainless steel pipe gate of grade 304 duly fixed at site with the help of M.S pivot & hinges grouted in cement concrete complete in all respect as per any kind of drawing & design |
| 14 | Providing and fixing Mettal extendable hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm. |
| 15 | Providing and Installation of Safety signage as per guideline for person with disability made of retro reflective sheeting as per colour specified and writing matter will be of same material in white fixed / pasted over 4mm thick aluminum composite sheet, including cost of writing matter with braille also firmly fixed on wall with nylon fastener, brass screw and washer complete as per specification and as desired by engineer in charge |
| 16 | Supplying of wheel chair fix in Judicial Court complex |
| 17 | Granular Sub-Base (Coarse Graded Material Grading-I):-Construction of granular sub-base by providing coarse graded material grading-I, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications (CSR-24.8(a) |
| 18 | Cement concrete 1:8:16 with 40mm gauge stone aggregate using concrete mixing volumetric type |
| 19 | Providing and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications |
| 20 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge. |
| 21 | Road Marking with Thermoplastic Compound Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications |
| 22 | Painting new letters and figures of blacksynthetic enamel paint to an even shade |
| 23 | Construction of Toilet Facilities for Disability Person and Transgender Person |
| 24 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation |
| 25 | Cement concrete 1:5:10 with 40 mm gauge stone ballast. using concrete mixing volumetric type |
| 26 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 27 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 28 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 29 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres |
| 30 | First Class burnt brick work laid in cement sand mortar 1:6 in in first storey upto 4 merters above plinth level. |
| 31 | Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete |
| 32 | Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter. |
| 33 | Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter. |
| 34 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 35 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture |
| 36 | Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete P.B,lintel & RCC slab (1.2qtl/cum)(1.41+2.40cum) |
| 37 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 38 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 39 | Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge. |
| 40 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 41 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 42 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 43 | 12.5 mm thick cement plaster 1:4 |
| 44 | 20mm thick cement plaster 1:4 in two coat |
| 45 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 46 | Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitered and electrically flash- welded, with iron fittings including necessary iron handles, hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire gauge) |
| 47 | Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respect. |
| 48 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area |
| 49 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 50 | Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick. |
| 51 | Providing & Fixing decorative high pressure laminated sheet 1mm SF thick ith high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 52 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm |
| 53 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16mm |
| 54 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 55 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 56 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 57 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 58 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade |
| 59 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 60 | Public Health Services |
| 61 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100 mm sand filling using mechanical mixer for mixing of material |
| 62 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/ Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.2 (9-3\\" + 6-9\\") x 7-0\\" = 224.00 sft2 (6-9\\" + 6-0\\") x 7-0\\" = 178.50 sftTotal = 402.50 sftDeduct door = 2 x 7-0\\" x 2-6\\" = 35 sft402.50 - 35 = 367.50 Sft367.50 x 0.092903 = 34.14 sqm |
| 63 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)1 x 9-3\\" x 6-9\\" = 62.44 sft1 x 6-9\\" x 6-0\\" = 40.50 sftTotal = 102.94 Sft102.94 x 0.092903 = 9.56 sqm (say 10 sqm) |
| 64 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition |
| 65 | Size 75 mm x 75 mm |
| 66 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 67 | Through wall 34.29 cm thick |
| 68 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge |
| 69 | Providing and fixing in position SS Brass Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect. |
| 70 | 35mm dia 600mm (24\\") long |
| 71 | Foldable U type 762mm long |
| 72 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. |
| 73 | Size 630 mm x 450 mm x 830 mm |
| 74 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. |
| 75 | Vitreous chinaware standard white pedestal for wash hand basin. |
| 76 | Vitreous chinaware standard white half pedestal for wash hand basin. |
| 77 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge) under various fixtures complete in all respect. |
| 78 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge) with various fixtures complete in all respect. |
| 79 | C.P. Brass extension piece 75mm long |
| 80 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 81 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge) fixed in to wall with C.P brass screws complete in all respect. |
| 82 | C.P. brass toilet paper holder |
| 83 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 84 | C.P.brass 15mm Concealed stop cock with flange. |
| 85 | C.P.brass 15mm Angle valve without flange |
| 86 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 87 | PVC tube connection of size 15 mm x 450 mm with PTMT nut |
| 88 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 89 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 90 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 91 | C.P. brass Bib cock foam flow without flange |
| 92 | Providing and fixing in position 15mm C.P. Pillar cock foam flow of approved make (to the approval of Engineer-in-charge) |
| 93 | Providing and fixing jet spray with 2'-6\\" long PVC pipe. |
| 94 | With C.P. Brass nut |
| 95 | Providing & Fixing in position plastic moulded frame mirror Size 550mmx400mm with 4mm thick hard board backing of required shape fixed in position with rawl plugs, C.P. brass screws and washers complete in all respect |
| 96 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 97 | Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 98 | C.P brass towel ring |
| 99 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. |
| 100 | Aluminium khunti with 4 pegs |
| 101 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 102 | CPVC SDR 11 pipes & fittings 25mm o/d |
| 103 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 104 | Single Socket Type B |
| 105 | 110mm o/d SWR UPVC pipe lines laid complete |
| 106 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. |
| 107 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 108 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 109 | 600mm x 900mm inside with 455mm x 455mm cover and frame light duty double seal |
| 110 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 111 | For 110mm o/d pipes |
| 112 | Single Tee |
| 113 | Door Elbow 90 Degree (All side socketed) |
| 114 | P Trap/Floor Trap 110mm x 110mm |
| 115 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. |
| 116 | For pipes 100 to 250 mm Diametre |
| 117 | Water Supply pipe line connection with existing pipe line |
| 118 | Electrical Services |
| 119 | PROVIDING INTERNAL ELECTRICAL INSTALLATIONS |
| 120 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: |
| 121 | Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 122 | Wiring light point |
| 123 | Wiring 6Amp. Plug control comprising wall socket point |
| 124 | PVC INSULATED FR COPPER CONDUCTOR CABLES: |
| 125 | Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 126 | Overall size 1.5sq.mm (Un-sheathed) |
| 127 | Overall size 4sq.mm (Un-sheathed) |
| 128 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: |
| 129 | Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 130 | Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) |
| 131 | MINIATURE CIRCUIT BREAKERS: |
| 132 | Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 133 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 134 | MCB double Pole 40 amp. (10kA, Curve-C) |
| 135 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE): |
| 136 | Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 137 | Overall size 10sq.mm (2Core) Un-armoured (on surface) |
| 138 | SHEET METAL DOUBLE DOORDISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: |
| 139 | Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 140 | SP&N Double Door Distribution Board 4 way each |
| 141 | Supply and erection of LED batten 20 Watt LED with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per pecifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 142 | S/E of 12\\" Exhaust fan (300mm-900RPM) of ISI marked heavy duty motor with die cast Aluminium rotor mounted on two ball bearing including erection, connections and testing etc. complete with flexible wire and petty material reqd. for connections and louver shutter complete in all respects as approved and desired by the engineer in charge at site. |
| 143 | Supply and erection of LED Flood Light 80w (including LED driver) in aluminium pressure die cast housing with toughned glass cover (IP66 Protection) and secondary lenses with IP66 protection having efficiency of LED fixture minimum 120 lumens per watt and operating voltage between 140 to 270volt, input frequency 50Hz + 3% complete along with erection of the same with connections, testing etc. Flood light should install on existing parapet complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and Specification of the LED fitting should be as approved by O/o Advisor(Technical), Govt. of Punjab vide Letter no. AT/2021/GL/1410-1422 Dated 06/05/2021.Besides this the lighting fixture manufacturer should have inhouse NABL accredited lab. |
| 144 | Supply and erection of PIR Motion Sensor for automatically switching on and off the NSR lighting fixtures with Complete in all respect as approved and desired by the engineer incharge at site. |
| 145 | Supply and erection of Panic Switch/Emergency Call System |
| 146 | Supply and erection of Panic Switch/Emergency Call System for Disabled in Wash room with Visual and audio Indicator with 1 Pull cord, 1 Siren, 1 LED Light Blinker 230V, 50Hz AC operation Complete in all respect as approved and desired by the engineer incharge at site. Please Enable Macros to View BoQ information |