| 1 | Dismanteling fencing wire mesh , any type |
| 2 | Dismanteling post, struts , (wood , steel or Rcc) any section incl. taking out embede portion in concrete or brickwork and making disturbed portion good |
| 3 | Excavation in post holes or similer holes each nexc. 0.5 cum getting out returning filling in and ramming earth around in layers n. exc 25 cm,watering , and removing surplus soils to a distence nexc 50m and making good surface in hard soils,complete all as specified. |
| 4 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate ) as in foundation concrete for fencing post. |
| 5 | S&F angle iron fencing post and struts including cutting tops to shape as directed, drilling holes, notching for wire etc , flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-410-0 or Fe 310-0 anyu size. |
| 6 | S&F MS Screw bolts ( machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut length exc. 5 cm but not exc 10 cm long 11 to 15mm dia of shank. |
| 7 | Supply only chain link MS galvanised fencing any size or type and any type of strands, rails, straining bolts etc incle provn of binding wire all complete |
| 8 | Fixing only chain link fencing any mesh, size and type to any type of standards, rails, straining bolts etc incl provn of binding wire |
| 9 | M&L for round bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hoping for columns, hooking ends and binding with and incl MS Wire (annealed) not less than 0.9mm dia or securing with clips. Fe-410-w (Gde-E-250) quality A or Fe-290 (Gde-E-165) |
| 10 | S&F in repair GI two strand, steel barbed wire 2.24mm dia, narbed with 2mm dia barbs @ 75mm spacing and straining and fixing to any type of standard rail, straining bolts, inlc securing or tying at crossing with and provn of galvanised mild steel wire staples or steel pins etc. All as specified (Each line of wire to be measured.) |
| 11 | M&L two coats of synthetic enamel paint to new steel surfaces over a coat of red oxide primer surfaces of any description exc 10 cm in witdth or girth |
| 12 | M&L preparing new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer surface area not exc. 10cm in width or girth |
| 13 | Demolition & breaking up drain pipe (salt glazed , AC or reinforced concrete) set in cement mortar for 150 mm dia pipes. |
| 14 | All as item No.13 above but for internal dia of pipe 200mm. |
| 15 | Demolition of brick work (PCC Block) built in cement mortar including all arches, pillars all quoins etc complete all as directed. |
| 16 | M & L for excavation in trenches n exc 1.5M deep & exc. 1.5M wide and getting out in soft/loose soil |
| 17 | Material and labour for Modular Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in and setting in mortar CM 1:6, complete all as specified and as directed by engr-in-charge. |
| 18 | M & L Pre-cast cement concrete 1:3:6, type C1 (20 mm graded stone aggregate) as in block masonary with solid blocks, exc 10 cm in width and setting in cement mortar 1:4 complete. |
| 19 | Taking down cement plaster of any description of brick or stone wall etc incl racking out joints and hacking for key, scrubbing down with water etc complete |
| 20 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface incl mixing of water proofing compound finished even & smooth with using extra cement. (Note: WPC shall be measured & paid seperately) |
| 21 | M&L for preparing new plastered surfaces & applying two coats of cement base paint on walls. complete all as specified and directed. |
| 22 | Supply only integral water proofing compound. |
| 23 | taking down or dismantling bends, sockets, cowl, Y joints etc. all as complete |
| 24 | S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm. |
| 25 | S&F.110 mm dia PVC (SWR) bends, any radius with access door |
| 26 | S&F 110 mm dia PVC (SWR) branch piece (Single Y) equal or unequal. |
| 27 | S&F 110 mm dia PVC (SWR) branch piece double, (Single Y) equal or unequal. |
| 28 | S&F 110 mm dia PVC (SWR) vent cowl |
| 29 | M&L for reinforced cement concrete pipes class NP-3 , laid in trenches & jointed complete with collars, dia of pipe 150 mm . |
| 30 | All as item No. 29 above but for 200 mm internal dia of pipe. |
| 31 | M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in bed to drain pipes, incl packing under & hauching against the sides of pipes after they are laid and tested for 150 mm bore RCC pipe. |
| 32 | All as item No. 31 above but for 200 mm dia RCC pipe. |
| 33 | M&L for cutting into existing manholes for connecting new drains making good to pipe & rendering, cutting. Out existing benching for & forming branch channel in cement concrete 1:2:4 type B-1 smooth finishing & reforming benchine as required for bore of pipe 150 mm. |
| 34 | All as per item No. 33 above but for bore of pipe 200 mm . |
| 35 | Supply and fix in repair hume pipe septic tank 50 users capacity including all excavation earth work required and demolition and removal of old septic tank (any size) and removal of debris and connecting the new septic tank to the incoming sewer lines and connected to soak pit as directed. |
| 36 | all as per item No. 35 above but 25 users -do- |
| 37 | Demolition of cement concrete (reinforced) as in manholes cover. |
| 38 | M&L for providing reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone agg) as in slabs. complete all as directed by Engr-in-charge. |
| 39 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 40 | M&L for mild steel TMT bars 6 to 8mm dia cut to length, bent to shape required incl cranking, bending, hooking ends & binding with & incl mild steel wire (annealed) not less than 0.9 mm dia. |
| 41 | Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and rough finished surface of concrete similar work all as specified and directed. |
| 42 | M&L for PCC type B1(1:2:4, using 20mm graded stone aggregate) as in bed blocks/coping/ edging all as specified and directed. |
| 43 | Dismantling Plain or corrugated steel (corrugated/ semi corrugated etc) sheet in roof covering complete all as specified and directed. |
| 44 | Dismantling wrought iron or mild steel work of any description not otherwise provided for . |
| 45 | S&F Rolled Sections as in main croos beams , hip and jack rafters; purlins, where connected to common rafter , posts etc. conf to Fe-410-w(gdeE-250 quality-A) |
| 46 | M &L for MS work as in wind tie or any other work incl cutting, drilling holes etc. |
| 47 | S & F 0.5mm thick corrugated pre painted / coloured galvalume sheet in roofing fixing all as per manufactures instructions with all fittings and accessories etc complete. |
| 48 | All as per item No.47 above but plain sheet fix in valley gutter / ridge/view cutter etc. |
| 49 | M&L for cement concrete 1:3:6 type C2 (using 40mm graded stone agg.) as in plinth protection 75 mm thick finished top surface even and smooth with out using extra cement |
| 50 | Demolition of concrete ( un reinforced ) in ground floors and paving nexc 15 cm thk (below or above ground level) |
| 51 | M & L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in sub base for hard standing complete all as specified and directed. |
| 52 | M&L for cement conceret 1:2:4 Type B-2 Using 40 mm graded stone aggregate as in surface channel and drain bed wall and floor etc. |
| 53 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. |
| 54 | M/L PCC type B1, 1:2:4 (20 mm Gr. Agg ) 50mm thick as in leveling course for floor finishes etc all as specified and as directed. |
| 55 | M/L PCC type D2 1:4:8 (40 mm Gr. Agg ) 75mm thick as in sub base. |
| 56 | M&L for laying machine pressed precast concrete interlocking reflective coloured (Glossy Finish) rubber mouldedpavers block any shape and size confirming to IS 15658-2006 of 55mm to 60mm thick, M-35 Grade over 30mm thick sand layer watering and ramming all as specified. |
| 57 | M& L Chequared Cement Concrete (Glossy finish) rubber moulded Tiles 30 CM x 30 CM X 25 mm th set and jointed in cement slurry and pointed in neat grey cement & pigment in floors over screed bed 15 mm thk in cm 1:6 .complete all as specified. |
| 58 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar all as specified. |
| 59 | M&L for machine cut kota stone slab flooring 20-22 mm th over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl cutting, rubbing and polishing to receive mirror finish over 20 mm th screed bed in CM 1:6 complete all as specified and as directed. |
| 60 | all as above item ser No 59 but on skirting over 10 mm th backing coat in CM 1:4 complete. |
| 61 | M&L for Marble work green marble 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with green marble shade complete all as specified. |
| 62 | M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed no pigment to match the shade of the slab including rubbing and polishing complete all as specified. |
| 63 | Material and labour for 20 mm thick granite stone machine cut (table rubbed and polished) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigments to match the shade of granite stone including grinding and polishing, rounding to edges of granite stone etc.complete all as specified and directed. |
| 64 | Dismantling floor hearth or wall tiling incl cement mortar bedding but not backing, removing serviceable tiles to stores complete all as specified. |
| 65 | M&L for vitrified coloured tiles 10mm th (square/rectangular) polished area of each tile 0.30 sqm but n exc 0.42 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm th screed bed in CM 1:6 complete all as specified. |
| 66 | above ser No 65 but on skirting over 10 mm th backing coat in CM 1:4 complete all as specified and as directed. |
| 67 | M&L for Non-skid coloured Ceramic tiles of size 300 x 300 x 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the coloured tiles over and including 15mm thick Screed bed or bedding layer in CM 1:6 for laying floor finishes complete all as specified. |
| 68 | M&L for Glazed ceramic tiles 350mm x 250mm x 7mm or 450mmX350mmX7mm thick (square/rectangular) of approved colour on vertical surface, set and jointed in neat cement slurry and pointed with coloured cement to match the tile colour over 10mm thick rendering in CM (1:4) for wall. |
| 69 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths ofcirculating pipes exc 250 & n exc 500 ltr , etc. |
| 70 | Cleaning and removing all scale and dirt, etc, from tanks and from mouths ofcirculating pipes exc 500 & n exc 1000 ltr , etc. |
| 71 | Taking down shutter with frame of area exc 1.50 Sqm but n.exc 4.0Sqm. |
| 72 | S & F for 10/12 mm thick toughened glass with etching fixed with necessary Ozone patch touch fittings including openable door chamfered edge polishing as in bathing cubical / partitions including all fitting and fixture as per manufasture instructions etccomplete all as specified |
| 73 | S & F in repair for aluminium powder coated partition using 'Jindal' aluminium SP/DP section or equivelent make as specified with 5mm thick tinted glass, PVC rubber beading, 12mm thick prelaminated partical board fixed with glazing clips etc complete all as specified and as directed, section SP (single partition) -20033, DP (double Partition)- 20034, glazing clips -4407 |
| 74 | Providing and carrying out water Proofing treatment to toilet, sunkan slabs, wet areas ets, after proper surface prepration, carry out cementitious ingection grouting at leakage point using cebex 100 plasticised expanding grounding admixture, application of polymer modified at slab wall junction using Nitoband SBR latex screen modifier cum bonding agent and application of two coat of brushbond RFX two part acrylic polymer modified cementitious elastomeric waterproof and protective coating etc, complete including 15mm thick cement plaster in CM 1:4 all tools and plant as per manufacturers specification paint complete all as specified and directed. |
| 75 | Dismantling wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness incl. cover fillets and alum snip grid. |
| 76 | M and L for 10 mm thick Polypan PS 20010 Prelam PVC (hallow profile) sheets used for fixing on wall Lining and PVC false ceiling inclusive of necessary fixing as directed by manufacturer and engr-in-charge. |
| 77 | S & F Anodised Alu. Snap grid 605x605 mm frame wk for false ceiling and providing 9mm th Acoustical board/tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed in celing with screws to frame work or with staples on snap grid including hangers 6 mm dia G.I. ( up to 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 X 3 mm size 60 mm long all as specified |
| 78 | Disconnecting existing PVC water tanks of capacity 500 litres, setting aside (or lowering if required) for replacement complete all as specified and as directed. |
| 79 | Fixing only water tanks of capacity 500 Ltr incl cleaning and removing all scale and dirt etc from tanks and mouth of circulating pipes. |
| 80 | Disconnecting existing PVC water tanks of capacity 1000 litres, setting aside (or lowering if required) for replacement complete all as specified and as directed. |
| 81 | Fixing only water tanks of capacity 1000 Ltr incl cleaning and removing all scale and dirt etc from tanks and mouth of circulating pipes. |
| 82 | Dismantling water tanks and removing to site exc 250 ltr nexc 500 Ltr capacity. |
| 83 | S & F rotational moulded Polythene (HDPE) double layer water tanks, cylindrical & vertical type 500 Litres capacity hoisted and fixed in position including provision of 20mm/15mm dia. spouts for connecting inlet, outlet, over flow and washout pipes. |
| 84 | Dismantling water tanks and removing to site exc 500Ltr but n. exc 1000Ltr capacity. |
| 85 | S & F rotational moulded Polythene (HDPE) double layer water tanks, cylindrical & vertical type 1000 Litres capacity hoisted and fixed in position including provision of 20mm/15mm dia. spouts for connecting inlet, outlet, over flow and washout pipes. |
| 86 | S & F in repair Ball brass valve, high pressure, with polythene float horizontal plunger type, IS-1703-2000 marked screwed to iron pipe or brass ferrule of size 15 mm bore complete all as specified and as directed. |
| 87 | S & F in repair Ball brass valve, high pressure, with polythene float horizontal plunger type, IS-1703-2000 marked screwed to iron pipe or brass ferrule of size 20 mm bore complete all as specified and as directed. |
| 88 | Taking up or down steel tubes and connections including cleaning for refixing or removal to stones bore of pipe 15mm etc all as specified and directed by Engr-in -charge. |
| 89 | All as per item No.88 above but bore of pipe 20mm |
| 90 | M&L GI tubes, medium grade with all fittings and fixed complete to walls, ceiling or laid in floors, bore of pipe 15mm |
| 91 | All as per item No.90 above but bore of pipe 20mm |
| 92 | Supplying and laying15 mm of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified |
| 93 | Supplying and laying 20 mm of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified |
| 94 | Supply and Fixing in repair stop valves fancy type cast copper alloy with capsta'n heads screwed down high pressure screwed both ends for iron pipe or union fixed for 20 mm dia GI pipe. |
| 95 | S & F in repair bib taps cast copper alloy with capstan headscrewed down, screwed for iron pipe or for brass furrule and fixed for 15mm dia pipe. |
| 96 | S &F in repair pillar taps fancy type ,chromium plated with capstan heads screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed for 15 mm dia pipe. |
| 97 | S & F in repair Brass cromium plated with capstan heads shower rose of 125 mm dia complete all as specified. |
| 98 | S & F in repair Grating round 140 mm size of PTMT (Minimum weight 50gms.) |
| 99 | S/F in repairs Vitreous china wash basin white flat back size 550 x 400mm including , waste pipe and plug and porcelain stopper and brackets incl cutting for and pinning in ends of brackets or erecting stand along with 32mm dia CP waste coupling and PVC waste pipe complete all as directed. |
| 100 | S & F in repair for PVC connection pipe 15mm dia with PTMT nuts of length 450mm complete all as specified and directed. |
| 101 | Returning filling in including levelling , watering and well ramming in layers n exc 25 cm thick in soil. |
| 102 | Removal of surplus soil to a distance n exc. 50 M & depositing where directed at a level n exc. 1.5 M above starting point. Please Enable Macros to View BoQ information |