|
| 1 | SCHEDULE \\"A\\" |
| 2 | SCHEDULE \\"A\\" PART-I (Building Work)Lump sum price worked out by the contractor for 'Building Work' as listed in Schedule 'A' Part-I against the lump sum price inserted by the MES. |
| 3 | Sch 'A' Part-II (Internal Water Supply) Lump sum price worked out by the contractor for 'Internal Water Supply' as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. |
| 4 | Sch 'A' Part-III (Internal Electric Supply) Lump sum price worked out by the contractor for 'Internal Electric Supply' as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. |
| 5 | Sch 'A' Part-IV (External Water supply) Lump sum price worked out by the contractor for 'External Water supply' as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. |
| 6 | Sch 'A' Part-V (External Electric supply) Lump sum price worked out by the contractor for 'External Electric supply' as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. |
| 7 | Sch 'A' Part-VI (PATH ) Lump sum price worked out by the contractor for 'Road & Hard standing' as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. |
| 8 | Sch 'A' Part-VII (Sewage Disposal) Lump sum price worked out by the contractor for 'Area Drainage' as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES. |
| 9 | Sch 'A' Part-VIII (Area Drainage) Lump sum price worked out by the contractor for 'Area Drainage' as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. |
| 10 | Sch 'A' Part-IX (Compound Wall and Gate) Lump sum price worked out by the contractor for 'Compound Wall and Gate' as listed in Schedule 'A' Part-VII against the lump sum price inserted by the MES. |
| 11 | Sch 'A' Part-X (Solar Water System) Lump sum price worked out by the contractor for 'Solar Water System' as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. |
| 12 | Sch 'A' Part-XI (Rain Water Harvesting) Lump sum price worked out by the contractor for 'Rain Water Harvesting' as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES. |
| 13 | Sch 'A' Part-XII (Site clearance, excavation & earth works for external services) Lump sum price worked out by the contractor for 'Site clearance, excavation & earth works' as listed in Schedule 'A' Part-XII against the lump sum price inserted by the MES. |
| 14 | Sch 'A' Part-XIII (Demolition and Dismantling) Lump sum price worked out by the contractor for 'Site clearance, excavation & earth works' as listed in Schedule 'A' Part-XIII against the lump sum price inserted by the MES. |
| 15 | Note for Srl No 02 to 14The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 02 to 14 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 16 | Schedule 'A' Part-XIV (Miscellaneous works) |
| 17 | Item No 01 : S & F factory made SFRC MH cover with frame confirming to IS 12592-2002 HD 20 grade of size 750mm circular or rectangular surrounded with steel strip 70 x 1.5mm reinforced shall be as per relevant IS code and laid over man hole brick work or concrete in CM 1:4 incl reinforcement complete all as specified and directed. |
| 18 | Item No 02 : S & F on site LLDPE Septic Tank of capacity 4000 Ltr designed to carry sewage and sludge water, excavation in hard dense soil, PCC 1:4:8 below the foundation, with vent shaft, manhole openings with cover connection etc complete with upflow filter incl media for 30 users septic tank with upflow filters complete all as specified & directed. |
| 19 | Item No 03 : Soakage well excavation in hard dense soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete incl intercepting chamber and screen chamber made of brick masonry in CM 1:4, RCC cover slab in M-25 interconnecting pipes of RCC complete filled with brick bats of size 1.8m DIa 3.0m effective depth compelte all as specified and directed. |
| 20 | Item No 04 : S & laying for DWCPE (SN8) 180 (OD)/163(ID) mm, diameter Pipes for Depth 0.7-1.65 meter laid on 150 mm thick bed with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional complete all as specified and directed. |
| 21 | Item No 05 : S & laying for DWCPE (SN8) 180 (OD)/163(ID) mm, diameter Pipes for Depth 1.65-2.30 meter laid on 150 mm thick bed with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional complete all as specified and directed. |
| 22 | Item No 06 : S & F for sheet metal enclosure MCB DB VTPN 4 Way vertical type with incoming as MCCB with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing specification of wall complete all as specified and directed. |
| 23 | Item No 07 : M&L for shifting of existing pole by mechnanical means and refixing by excavation in trenches n exc 1.5m in any type of soil and PCC 1:3:6 upto GL and PCC 1:2:4 300mm above GL complete all as specified and directed. |
| 24 | Item No 08 : Removing of existing DI pipe and refixing by excavation in trenches by mechanical means, refilling the soil and removing excess soil n exc 1.00 km away from site complete all as specified and directed. |
| 25 | Item No 09 : Supply and laying pipe for 100mm DI pipe incl special class K-9 incl fittings complete all as specified and directed. |
| 26 | Item No 10 : S&F CP towel rail 600mm long fixed with and incl CP brass screws and wooden cleat complete all as specified and directed. |
| 27 | Item No 11 : S&F CP towel ring of dia 250mm fixed with and incl CP brass screws and wooden cleat complete all as specified and directed. |
| 28 | Item No 12 : S&F of brass extension nipplr 15mm dia and 50-75 mm long alongwith SS cover plate complete all as specified and directed. |
| 29 | Item No 13 : S&F CP Health faucet mild steel CP suitable for 15mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 30 | Item No 14 : S&F CP jet sprey of length 1.25 m long fixed in position complete all as specified and directed. |
| 31 | Item No 15 : S&F air cooled split unit air conditioner (AC) with copper winding, electric driven, single phase of capacity of 1.5TR, BEE 5 star rating inverter type with refrigerant R-32 all as specified and directed by engr-in-charge. |
| 32 | Item No 16 : S&F LED batten (1.2m) made of CRCA sheet housing Each with a PC glossy difusser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 105 lumens per watt and total power consumption not more than 19 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete. |
| 33 | Item No 17 : S&F (Exhaust Ventilation fan 300mm sweep metal body automaic front openting to prevent entry of foreign objects and easy maintainance and cleaning complete with fixing arrangement complete all as specified and directed. |
| 34 | Item No 18 : S & F for energy efficient exhaust fan of 230 mm sweep made of metal body Ventil Air - Each DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base compelte all as specified and directed. (Note: Cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted). |
| 35 | Item No 19 : S&F BLDC ceiling fans complete with blades, down rods and accessories, 230 V, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor complete all as specified and directed. |
| 36 | Item No 20 : S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as specified and directed |
| 37 | Item No 21 : M&L earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm x6.0mm thick buried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5m below ground level connected to and including galvanized iron wire 4.0mm not exceeding 7.5meters for each earth without protection pipe, including test point by means of bolts, nuts, check nuts, and washers made out of Gl all as shown on plate No 5 of SSR Part I to the extent applicable to this item including necessary making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 6 mm dia MS bars 3 Nos both ways with lifting hook made out of 6 mm dia bar and testing on completion to achieve value complete all se enecified and directed |
| 38 | Item No 22 : M & L for earthing complete with galvanized steel sarth plate electrode 60 cm x 60 cm x Each 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to Gl earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia, medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, Ci frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type of soil/strata and testing on completion. Note Gl earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. |
| 39 | Item No 23 : Supply and fix in replacement of LED Security Light Luminaire 35 watt 6000K with high power LED cool white. CRI 75, +/-5% supply voltage 220/240/50 Hz, light engine driver base. Pole adapter. Powder coated pressure die cast medium grade not less than with 1.2m, long in any shape with 2 nos of pole fixing clamps made out of MS flat, nuts bolts and painding with aluminium paint complete all as specified and directed. |
| 40 | Item No 24 : S & F for LED tube light fitting 2 feet x 10 watts mirror type with high out put diffuser, Each decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed. |
| 41 | Item No 25 : S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, Each anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 42 | Item No 26 : S&F energy efficient recessed mounted LED luminaire 35/36 Watt suitable for 2'x2' grid Each ceiling with flat diffuser and lumen output of 3300 lumens having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable in renewal of any type luminaire as required. Please Enable Macros to View BoQ information |