| 1 | Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in any type of soil getting out and levelling of bottom surface to required level complete all as specified and as directed. |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed. |
| 3 | Removing excavated material (soil) from site to a distance not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 4 | Supply and laying of old size sub class -B bricks as in cable protection laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and directed. |
| 5 | Supply and filing of sand free from impurities and vegetation as in sand cushioning with fine dry sand in trenches, for cable protection 10 cm below cable and 15 cm above cable punned to 18 cm complete all as specified and directed.NOTE: Punned depth of sand shall be measured and paid . |
| 6 | Supply and fixing 40 mm bore GI pipe, medium grade, for protection of cable, laid in trenches / under floors / Paths /along poles/ equipments etc complete all as specified & directed |
| 7 | Disconnecting Electric connections from LT Control pannel and starter of non clogging submerssible pump set of any size 5 HP to 25 HP capacity and removing the pipe line connections from discharge side and taking out submersible pump set along with, column pipe from sewage sump with the help of chain pully block including transportation to workshop and back for repair and lowering of same pump in sewage sump after repair including renewal of rusted nuts bolts, rubber gasket complete, making all electric connection good, complete all as specified and as directed . |
| 8 | Labour only for opening the centrifugal /submersible pump set, repairing, rewinding and assembling the pump set including insulating material of any size 5HP to 10 HP capacity complete all as specified and as directed . ( Copper winding wire and other spare parts required for repairing will be measured and paid separately under respective item) |
| 9 | Labour only for opening the non clogging submerssible pump set, repairing, rewinding and assembling the pump set including insulating material of any size 12.5 HP to 25 HP capacity complete all as specified and as directed( Copper winding wire and other spare parts required for repairing will be measured and paid separately under respective item) |
| 10 | Supply only copper winding wire of existing gauge for non clogging submersible / submerssible pump / induction motor sets all as specified and directed.NOTE: BOO shall be ordered by GE for working out consumption of copper winding wire in each non-clogging submersible and motor. |
| 11 | Supply only in renewal of following spare parts for non-clogging sewage submersible pump set any type of capacity upto 25 HP |
| 12 | SS rotor sleeve |
| 13 | SS rotor shaft ASS 410 |
| 14 | Water seal |
| 15 | Connetion plate |
| 16 | Re-metalling of rotor & turning/grinding |
| 17 | GM suction ring |
| 18 | GM/SS Impeller |
| 19 | SS stud with nut |
| 20 | Impeller nut |
| 21 | Impeller key |
| 22 | Joint of submersible cable any size |
| 23 | Mechanical seal set upper and lower |
| 24 | Jointing of cable kit without float switch |
| 25 | CI suction plate |
| 26 | O ring set |
| 27 | Insulation kit |
| 28 | Ball bearing 6312ZZ |
| 29 | Roller Bearing 3310 |
| 30 | Roller Bearing NU 305 |
| 31 | Temperature sensor |
| 32 | Moisture sensor |
| 33 | Bearing 6306 2RS1/C3 |
| 34 | Bearing 6308 2 R S1/C3 |
| 35 | Bearing 6309 2 R S1/C3 |
| 36 | Bearing 3212 |
| 37 | Labour for dismantling, disconnecting the centrifugal/sewage pump set from foundation including transportation to workshop and back for repair and re - fixing after repairing rewinding and assembling the pump set including insulating material of any size ,testing complete up to 15 HP including transportation to workshop for repair all as specified and directed. Note: Copper winding wire and other spare parts required for repairing will be measured and paid separately under respective item. |
| 38 | Supply only the following items for DB model pumps of capacity upto 15 HP |
| 39 | CI Impeller |
| 40 | Pump shaft SS AISI410 |
| 41 | Mechanical seal for pump shaft AISI-410 |
| 42 | Wear ring |
| 43 | CI Gland |
| 44 | Ball bearing 6307ZZ |
| 45 | Bearing housing NDE |
| 46 | Shaft Sleeve SS |
| 47 | impeller Nut |
| 48 | Lock nut |
| 49 | Gland packing |
| 50 | Set of O rings |
| 51 | Liquid deflector |
| 52 | SS Gland Eye Bolt with nut |
| 53 | Impeller Key |
| 54 | Oil seal |
| 55 | Mechanical seal for support plate |
| 56 | Bent plug |
| 57 | Set of gasket |
| 58 | Support foot |
| 59 | Lantern ring |
| 60 | coupling Key CS |
| 61 | Mechanical Seal |
| 62 | Star Coupling Set L-110 |
| 63 | Star Coupling Set L-190 |
| 64 | Note for item No 13 to 13.25: (a) Inventory of each pump/submersible pump repaired under above items shall be prepared itemwise and kept in record duly signed by Engineer-in-charge and JE(E/M). Inventory will be produced alongwith RAR for verification and tech check. (b) Cost of repair of each pump will not be beyond economical cost of repair. |
| 65 | M&L for Repair, servicing including Dismantling/taking down all electrical and mechanical connection of twin lobe existing blowers of pressure upto 0.65 kg/cm2 capacity upto 600 Cum/Hrs and servicing whole body, change gear oil/lubricant and V belt,overhauling of the same including refixing and testing complete all as specified and directed.Note:- Unit rate quoted shall be deemed to be included supply & fixing of spare parts and compressor oil/ lubricant and supply of following materials :-(i) Changing of rotors assembly alongwith shaft (ii) Compressor oil as recoended by OEM (Compressor oil required for refilling will be measured and paid under relevant item as supply only)(iii) Bearing as per sample for air blowers model (iv) Gasket kit as per sample for air blowers model(v) Oil seal as per sample for air blowers model (vi) V-belt as per sample for air blowers model(vii) Air filter as per sample for air blowers model |
| 66 | -Ditto- all as per item No 14 here-in-before but for pressure upto 0.8 kg/cm2 capacity upto 600 Cum/Hr. |
| 67 | -Ditto- all as per item No 14 here-in-before but for pressure upto 0.3 kg/cm2 capacity upto 400 Cum/Hr. |
| 68 | Note for item No 14 to 16:(a) Datewise cleaning shall be entered in MB alongwith location of STP.(b) Contractor will be required to remove sewage sludge cum mud and silt in sealed container outside of MOD land.(c)T&P required for cleaning shall be provided by contractor at his own arrangements. |
| 69 | M&L for taking out suction pipe from sump of any capacity, dismantling of foot valve of capacity 80 mm to 200 mm size screw / flanged type, and relowering after refixing in position the same duly cleaned / minor repair if any required such as renewal of rubber gasket/ lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as required and as directed. |
| 70 | M&L for periodical cleaning of oil & grease chamber of any size and removing of settled down sewage sludge cum mud/de-silting etc complete all as specified and as directed. |
| 71 | M&L for periodical cleaning of bar screen chamber of any size/ capacity and removing of settled down sewage sludge cum mud/de-silting etc complete all as specified and as directed. |
| 72 | M&L for periodical cleaning of sewage and removing of settled down sewage sludge cum mud/de-silting etc at for equalization tank of 2MLD plant at Shankar Vihar STP complete all as specified and as directed. |
| 73 | M&L for periodical cleaning of sewage and removing of settled down sewage sludge cum mud/de-silting etc at for equalization tank of 1 MLD plant at Mahipalpur STP complete all as specified and as directed. |
| 74 | M&L for periodical cleaning of sewage and removing of settled down sewage sludge cum mud/de-silting etc at for equalization tank of 650 MLD at Rangpuri STP complete all as specified and as directed. |
| 75 | M&L for periodical cleaning of sewage and removing of settled down sewage sludge cum mud/de-silting etc at for equalization tank of 150 KLD plant at DGIS STP complete all as specified and as directed. |
| 76 | M&L for periodical cleaning of sewage and removing of settled down sewage sludge cum mud/de-silting etc at for equalization tank of 100 KLD plant at TPT Coy complete all as specified and as directed. |
| 77 | M&L for periodical cleaning of sewage and removing of settled down sewage sludge cum mud/de-silting etc at for equalization tank of 80 KLD plant at OTM-I complete all as specified and as directed. |
| 78 | M&L for periodical cleaning of sewage and removing of settled down sewage sludge cum mud from tube settler tank of 2 MLD/1 MLD/650 KLD STP plant complete all as specified and as directed. |
| 79 | M&L for periodical cleaning of sewage and removing of settled down sewage sludge cum mud from tube settler tank of 150/100/80 KLD STP Plant complete all as specified and as directed. |
| 80 | M&L for periodical cleaning of sewage and removing of settled down sewage sludge cum mud from MBBR-1 & MBBR-2 of 2 MLD/1 MLD/650 KLD STP Plant complete all as specified and as directed. |
| 81 | M&L for Periodical Cleaning of Sewage and removing of settled down Sewage sludge cum mud from MBBR-1 & MBBR-2 of 150/100/80 KLD STP Plant complete all as specified and as directed. |
| 82 | M&L for cleaning of treated water tank of storage capacity 3,00,000 ltrs (300 Cum), filter feed tank of capacity 30 Cum, chlorine contract tank of capacity 15 Cum thoroughly by removing mud, grits etc complete all as specified and as directed. |
| 83 | M&L for cleaning of treated water tank of storage capacity 3,50,000 ltrs (350 Cum), filter feed tank of capacity 65 Cum, chlorine contract tank of capacity 42 Cum thoroughly by removing mud, grits etc complete all as specified and as directed. |
| 84 | M&L for cleaning of treated water tank of storage capacity 2,50,000 ltrs (250 Cum), filter feed tank of capacity 84 Cum, chlorine contract tank of capacity 21 Cum, slurry tank of capacity 25.87 Cum thoroughly by removing mud, grits etc complete all as specified and as directed. |
| 85 | M&L for cleaning of treated water tank of storage capacity 50,000 ltrs (50 Cum), filter feed tank of capacity 30 Cum, chlorine contract tank of capacity 15 Cum thoroughly by removing mud, grits etc complete all as specified and as directed. |
| 86 | Notes for Srl item No 17 to 33 :- (a) leaning inner surface of tank complete by scraping with steel wire brush and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr all as specified and directed.(b) Washing with clean water and bleaching powder complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr all as specified and directed. |
| 87 | M&L for periodical cleaning dewatering and pumping out of existing accumulated Sewage/sludge and removing of settled down Sewage sludge cum mud/de-silting etc of Sewage Well of size 8 mtr height x 6 mtr dia complete all as specified and as directed. |
| 88 | M&L for Periodical cleaning dewatering and pumping out of existing accumulated sewage/sludge of sewage installation and removing of settled down Sewage/ sludge cum mud/de-silting etc of Sewage well of size 8 mtr height x 9 mtr lentgh x 7 width Notes for item No 17 to 35 :- Rate quoted shall include the following aspects:- (i) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De-Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes.(ii) Tractor mounted storage tank of appropriate capacity not less than 1 KL with driver directly collected from the soak well and disposing the same to the location where approved by the Delhi Canttonment Board/PCB.(iii) Tractor/truck with driver for disposal of sewage sludge and POL required for the same (duly covered with necessary tirpaul/tent cloths) and depositing the same to the location where approved by the Delhi Canttonment Board/PCB. (iv) Labour element shall be included in the unit cost quoted by contractor. (v) Necessary oxygen mask shall be included in the unit rate quoted by the contractor. |
| 89 | M&L for renewal of filteration media drying bed with sand and stone gravels (a) Natural graded gravels of size 20mm to 25mm - 150mm layer (b) natural graded of size 15mm to 10mm - 100 mm layer (c) natural graded gravels of size 10mm to 6mm - 100 mm layer (d) White graded coarse quartz sand of size 8-14 mm - 100 mm layer (e) White graded coarse quartz sand of 16-30 mm 600 mm layer complete all as specified and directed. |
| 90 | M&L for renewal of unserviceable MBBR Media from the tank and supply of filling fresh media of MBBR media in the main reactor as specified of existing /suitable Make with the following specificatios:-Effective surface area of media Approx - 400 Sqm(b) Media ht Approx - 15/10 mm(c)Media dia Approx- 22 mm(d) Weight per unit surface area approx -22 mm(e) Voidage - >093 gm/Cucm(g) Media fill Range - 25-55% of volume |
| 91 | Supply and fixing in renewal Stainless steel Pipe of size 15 mm dia with holes at 1 mtr intervals welded at closed ends fixing on floors for use of diffusers of air blowers complete all as specified and directed. |
| 92 | Taking down Old Unserviceable Dosing System refixing the same after repair/renewal of the unserviceable parts (Copper winding wire and other spare parts required for repairing will be measured and paid separately under respective item.) |
| 93 | Supply only FRP Tank 100 Ltrs |
| 94 | Supply only Back Pressure Valve |
| 95 | Supply only Safty Relief Valves |
| 96 | Supply only Pulsation Dampeners |
| 97 | Supply only Suction and discharge Valves |
| 98 | Supply only O Ring |
| 99 | Supply only Injection Valves |
| 100 | Supply only Injection pipe |
| 101 | Boring holes under road pavement manually in any type of soil upto 200 mm bore complete all as specified and directed. |
| 102 | Supply and fixing in renewal mild steel work for manhole cover, stair case steps etc made of MS angle/ flats/channels etc including cutting out top and bottom to shape as directed, drilling holes, notching for wire etc flat iron fillets including all necessary drilling, bolting or rivetting etc and similar works confirming to Fe-290, Gde E-165 and applying two coats of synthetic enamel paint over a coat of red oxide primer including preperation after demolition of existing covers,steps etc complete all as specified and as directed. |
| 103 | Supplying and fixing in renewal pressure gauge 100 mm dia suitable for 0 to 10 kg/sqcm for online purposes complete all as specified and as directed. |
| 104 | Dismantling of existing water meter strainers, dirt box, 80 mm bore to 200 mm bore , any make/model, fixed at any location and cleaning of jalli,renewal of packing seal etc. to make it functional including making good connections with gasket rubber sheet , nuts & bolts, fixed in horizental/inclined/ vertical position complete all as specified and as directed . |
| 105 | Supplying, fixing, jointing & testing cast Iron Sluice Valve, ISI Marked, flanged ends drilled pressure rating PN-1.6, PD Short body confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top complete with Nuts, Bolts, washers and rubber gaskets of 80 mm dia including taking out of unserviceable sluice valve complete all as specified and as directed. |
| 106 | -Ditto- all as per srl item No. 44.00 here-in-before but 100 mm dia |
| 107 | -Ditto- all as per srl item No. 44.00 here-in-before but 150 mm dia |
| 108 | Supplying, Laying, jointing, testing and commmisioning of DI Pipe 80 mm dia, as per ISO - 7186 - 2011, K-7 with spigot and socketed ends centrifugally cast Class LA Push on joint laid in trenches complete including taking out of old UNSV pipe line any type complete all as specified and directed at site.Note- Excavation & earth work for new location shall be measured & paid for seperately. |
| 109 | -Ditto- all as per srl item No. 47.00 here-in-before but 100 mm dia |
| 110 | -Ditto- all as per srl item No. 47.00 here-in-before but 150 mm dia |
| 111 | -Ditto- all as per srl item No. 47.00 here-in-before but 200 mm dia |
| 112 | M&L for CI/DI special such as tees, bends of any size and radius, tapers, collers, tail pieces, caps and plugs complete all as specified and as directed for upto 150 mm bore. |
| 113 | -Ditto- all as per srl item No. 51.00 here-in-before but 200 mm to 300mm bore |
| 114 | Supply and fixing for Tyton joints (with SVR gasket, IS-5382 marked) suitable for DI pipe of 80 mm dia complete all as specified and as directed. |
| 115 | -Ditto- all as per srl item No. 53.00 here-in-before but 100 mm dia |
| 116 | -Ditto- all as per srl item No. 53.00 here-in-before but 150 mm dia |
| 117 | -Ditto- all as per srl item No. 53.00 here-in-before but 200 mm dia |
| 118 | Supply, installation and testing of in renewal flanged ends flow Meter ISI marked woltman type, Class 'B' of 100 mm dia and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including cutting of pipes complete all as specified and directed.Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item. |
| 119 | -Ditto- all as per srl item No. 57.00 here-in-before but 200 mm dia |
| 120 | Supplying , laying , jointing, welding & testing MS Pipe, Heavy duly class 'C' of 80 mm bore as per IS 1239-2004 Laid in trenches or laying on floors for connections to centrifugal pump sets or through HDD Pipe under road/path/hard standing, for fresh water supply pipe line, suction of pump set, to header and to connected out going water main CI/DI pipe line, including taking down the u/s one complete all as specified and directed.Note:- (a) MS Flanges and flanged joints complete with jointing material shall be measured and paid separately. |
| 121 | -Ditto- all as per srl item No. 59.00 here-in-before but 100 mm bore |
| 122 | -Ditto- all as per srl item No. 59.00 here-in-before but 150 mm bore |
| 123 | M&L for Cutting of 80mm bore SS/MS/CI Pipe in position for reducing to required length for insertion of new branches of 100 mm bore complete all as specified and directed. |
| 124 | -Ditto- all as per srl item No. 62.00 here-in-before but 150 mm bore |
| 125 | Supply and fixing of CI butterfly valve of size 80 mm bore, PN 1.6 complete all as specified and directed. |
| 126 | -Ditto- all as per item No. 64.00 here-in-before but size 100 mm bore. |
| 127 | -Ditto- all as per item No. 64.00 here-in-before but size 150 mm bore. |
| 128 | Supply and laying 3 layer (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fitting in trenches/wall/celling or laying in floors complete of 20 mm size outer dia including all fittings with and including taking down old Pipe complete all as specified and as directed.Note :- Excavation & earth work shall be measured & paid for separetely. |
| 129 | -Ditto- all as per Item No 67.00 here-in-before but 25 mm size outer dia. |
| 130 | -Ditto- all as per Item No 67.00 here-in-before but 50 mm size outer dia. |
| 131 | -Ditto- all as per Item No 67.00 here-in-before but 63 mm size outer dia. |
| 132 | -Ditto- all as per item No.67.00 here-in-before but 75 mm size outer dia. |
| 133 | Supply, fixing, jointing and testing of Cast iron Non Return valve of 80 mm dia, without by pass arrangement , Swing type, confirming to IS 5312, flanged ends, pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. |
| 134 | -Ditto- all as per item No. 72.00 here-in-before but 100 mm dia. |
| 135 | -Ditto- all as per item No. 72.00 here-in-before but 150 mm dia. |
| 136 | -Ditto- all as per item No. 72.00 here-in-before but 200 mm dia. |
| 137 | Supplying and fixing, MS flanges of 80 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and directed |
| 138 | Supplying and fixing, MS flanges of 100 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and directed |
| 139 | Supplying and fixing, MS flanges of 150 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and directed |
| 140 | Supplying and fixing, MS flanges of 200 mm bore not less than 16 mm thick duly welded on ends of MS pipe complete all as specified and directed |
| 141 | M&L for Flanged Joints with rubber or fibre board gasket including nuts, bolts and double washers of 80 mm dia complete all as specified and directed |
| 142 | -Ditto- all as per item No. 80.00 here-in-before but 100 mm dia. |
| 143 | -Ditto- all as per item No. 80.00 here-in-before but 150 mm dia. |
| 144 | -Ditto- all as per item No. 80.00 here-in-before but 200 mm dia. |
| 145 | Supply and fixing of PPR gate valve (Brass inserted), ISI Marked of 25 mm bore, complete all as specified and as directed. |
| 146 | -Ditto- all as per item No. 84.00 here-in-before but 32 mm bore. |
| 147 | -Ditto- all as per item No. 84.00 here-in-before but 50 mm bore. |
| 148 | -Ditto- all as per item No. 84.00 here-in-before but 63 mm bore. |
| 149 | S&F for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 500 Ltr hoisting and fixing in position here-in-before, all as specified in SSR Part I including taking down existing tank with fittings, complete all as specified and directed. |
| 150 | Trimming of tree branches around Bar screen chamber , MBBR reactor, Tube settler, Filteration system, chlorine contact tank/ hypo Dosing tank sludge drying bed , Oil and grease trap chamber, Rawwater collecition sump and over the boundry wall of STP plants area and cleaning upto 3 Mtrs distance from Eqpts and plants removing cut materials (tree branches) from site and stacing properly where directed. Grith of branch (where cutting took place) not exceeding 50 mm complete all as specified. |
| 151 | S&F mild steel plate/board of size 200mmx650mm of thickness 3mm MS plate duly painted and written \\"NO ENTRY\\" on bothsides alongwith necessary fixing arrangements for instalations as per sample and as directed. |
| 152 | Supply and fixing in renewal of flat submersible copper cable of size 2.5 sqmm 3 core 1100 volts complete all as specified and directed. |
| 153 | -Ditto- all as per item No. 91.00 here-in-before but of size 4 sqmm . |
| 154 | -Ditto- all as per item No. 91.00 here-in-before but of size 6 sqmm |
| 155 | -Ditto- all as per item No. 91.00 here-in-before but of size 10 sqmm . |
| 156 | Supply & laying LT XLPE insulated armoured PVC sheathed heavy duty underground cable with aluminium multi stranded conductor with armoured 1100 volt grade of size 10 Sqmm 4 core laid in trenches /duct passing through pipe/ duct fixed in pole and connecting and testing complete all as specified and directed. |
| 157 | -Ditto- all as per item No. 95.00 here-in-before but 16 Sqmm 4 core |
| 158 | -Ditto- all as per item No. 95.00 here-in-before but 25 Sqmm 3.5 core |
| 159 | -Ditto- all as per item No. 95.00 here-in-before but 50 Sqmm 3.5 core |
| 160 | Supply and fix PVC insulated multistranded aluminium conductor, 1100 volts grade, 6 sqmm cross sectional 2 core complete all as specified and directed. |
| 161 | Supply and fix PVC insulated multistranded aluminium conductor, 1100 volts grade, 10 sqmm cross sectional 2 core complete all as specified and directed. |
| 162 | S & F in renewal of Heat Resistance, weather proof agro shed GREEN WEDGE net for covering of tanks at various STP complete with fixing arrangement around the tank complete all as specified and as directed. |
| 163 | M&L for complete overhauling and repairing of multigrade sand filter with renewal of filter media as per existing and activated carbon filter media including renewal of filter media other connected assessories as required at site of STP capacity of 2 MLD and 01 MLD including testing and wire mesh size shuold as per existing ,colour in Black ,Grade of GAC 8x30 and bulk density approx 450kg /cum, Hardness( abrasion number) approx 95-99 and PH value - 7 complete all as specified and directed. |
| 164 | M&L for complete overhauling and repairing of multigrade sand filter with renewal of filter media as per existing and activated carbon filter media including renewal of filter media other connected assessories as required at site of STP capacity o 650 KLD including testing and wire mesh size shuold as per existing ,colour in Black ,Grade of GAC 8x30 and bulk density approx 450kg /cum, Hardness( abrasion number) approx 95-99 and PH value - 7 complete all as specified and directed. |
| 165 | M&L for complete overhauling and repairing of multigrade sand filter with renewal of filter media as per existing and activated carbon filter media including renewal of filter media other connected assessories as required at site of STP capacity of 150/100/80 KLD including testing and wire mesh size shuold as per existing ,colour in Black ,Grade of GAC 8x30 and bulk density approx 450kg /cum, Hardness( abrasion number) approx 95-99 and PH value - 7 complete all as specified and directed. |
| 166 | Supplying and fixing of chequerred rubber matting of size 2m x 1m x 10mm thick complete all as specified and directed. |
| 167 | Supply & Fixing in renewal MCCB 250 Amp 415 Volts, 36 KA, 4 pole, 50 Hz, with adjustable thermal & fixed magnetic setting complete all as specified and as directed. |
| 168 | Supply & Fixing in renewal MCCB 200 Amp 415 Volts, 36 KA, 4 pole, 50 Hz, with adjustable thermal & fixed magnetic setting complete all as specified and as directed. |
| 169 | Supply & Fixing in renewal MCCB 100 Amp 415 Volts, 16 KA, 4 pole, 50 Hz, with fixed thermal & fixed magnetic setting complete all as specified and as directed. |
| 170 | Supply & Fixing in renewal MCCB 63 Amp 415 Volts, 16 KA, 4 pole, 50 Hz, with fixed thermal & fixed magnetic setting complete all as specified and as directed. |
| 171 | Supply & Fixing in renewal MCB 20 Amp DP complete all as specified and as directed. |
| 172 | Supply and fix in renewal 3 pole power contactor ML-3, 40 Amps,415/440 volts,50 Hz suitable for fixing in existing panel complete all as specified and as directed. |
| 173 | Supply and fix in renewal 3 pole power contactor ML-2, 32 Amps,415/440 volts,50 Hz suitable for fixing in existing panel complete all as specified and as directed. |
| 174 | Supply & Fixing in renewal of Timer suitable for mounting on existing contactor complete all as specified and as directed. |
| 175 | Supply & Fixing in renewal 3 pole power contactor, 3TF-35 with luxury block type (NO/NC) ,32A-55A, complete all as specified and directed. |
| 176 | Supply & Fixing in renewal 3 pole power contactor MNX25 type contactor,25A-45A, complete all as specified and directed. |
| 177 | Supply and fixing in renewal thermal over load relay, type MN, range 20-32 Amp complete all as specified and as directed. |
| 178 | Supply and fixing in renewal thermal over load relay, type MN, range 45-75 Amp complete all as specified and as directed. |
| 179 | Supply and fixing in renewal automatic star-delta starter in sheet metal enclosure with voltmeter and amp meter.Each motor rating 415 V 3 phase 50 hz for 5 HP submerisible pump complete all as specified and directed. |
| 180 | -Ditto- all as per item No.94 here-in-before but for 7.5 HP submerisible pump. |
| 181 | -Ditto- all as per item No.94 here-in-before but 10 HP submerisible pump. |
| 182 | Supply only Compressor Oil (as recommended by OEM of eqpts) in air blower at STPs in sealed container . |
| 183 | M&L for plate earthing complete with galvanised copper plate electrode 600×600×6mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and 25×4mm copper strip earth lead bolted (with brass nuts, bolts & check nuts) and riveted to earth plate at one end and connected to test point at the other, earth strip from top of electrode to body of equipment fixed with clamps, bolts, nuts and washer and also including necessary earth work, excavation etc and medium grade 40mm GI pipe of suitable length for protection of copper strip, 20 mm bore GI pipe light grade for watering from bottom of earth pit to top of plate electrode, complete with wire mesh, funnel and earth pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate and RCC cover as shown in electrical plate No. 3 of SSR Part-I and testing on completion complete all as specified and directed. NOTE: Excavation and earthwork shall be deemed included in quoted unit rate and strip upto 7.5 m from test point included in unit rate. |
| 184 | M&L for PCC (1:4:8) type D2 using 40 mm crushed graded stone aggregate for foundation complete all as specified and as directed. |
| 185 | M&L for PCC (1:2:4) type B1 coping with 20mm graded crushed aggregate for grouting MS frame including necessary foam work complete all as specified and as directed. |
| 186 | M&L for brick work with subclass 'B' bricks straight or curved on plan to any radius in walls built in cement mortar (1:4) complete all as directed and specified. |
| 187 | M&L for rendering plaster 10 mm thick with cement mortar (1:6) on fair faces of brick work for finishing the surface fair and even complete all as specified and directed. |
| 188 | Supply and fixing for painting to steel and iron surfaces by using spray Gun with one coat of red oxide and two coat of synthetic enamel paint as per existing pattern after preparation of old surfaces of any description over 10 cm in width or girth complete all as specified and as directed. |
| 189 | Supply and fixing for painting to Sluice Valves and NRV surfaces by using spray Gun with one coat of synthetic enamel paint as per existing pattern after preparation of old surfaces of any description over 10 cm in width or girth complete all as specified and as directed. |
| 190 | Supplying and fixing in renewal of 1.5 sqmm of PVC insulated copper conductor, single core cable in the existing surface /recessedPVC/Steel conduit /PVC casing caping as required complete all as specified and directed. |
| 191 | Supply and fixing in renewal of Bldg security light 60 Watts IP 66 including brackets and fittings complete all as specified and as directed |
| 192 | Supply and fix in renewal street light bracket 1.2 mtr long made out of 40 mm dia light grade GI tuing made to shape including two sets of flat iron clamps, nuts, bolts washers complete all as specifiedand directed. Note: Clamp shall be made of 40 x6 mm flat iron and fixed with 15mm dia x 50 mm long bolts nuts. Wt of each clamp shall not be more than 5 kg including wt of nuts and bolts . Providing two coats of aluminium paint over one coat of red oxide primer shall be part of item at no extra cost . |
| 193 | M & L for preparation of old surfaces of LT steel tubular poles of any size and type with bracket clamps etc and painting with two coats of Aluminium paint upto 6 mtr long and exposed surface of Pole yellow and black paint in strips alternative 30 cm wide upto 1.5 mtr from ground level including marking of pole No's with paint complete all as specified and as directed. |
| 194 | Carrying samples for Testing of treated water of STP ,submission of detailed test report to the office of the Engineer-in-charge and testing in NABL approved laboratory as approved by GE.Details are as under :-(a) Carrying out minimum essential testing of water as per IS 10500 of 1991 mandatory for chemicals, colour, odour, PH value, TSS, BOD, COD, Total residual chlorine, total Nitrogen, Total Phosphorus, Sulphate, oil and grease , Ammonical Nitrogen (NH3-N) and Bacteriological total coliform organisms per 100 ml (MPN) and E colliie in 100 ml.Note:- Rate quoted shall deemed to be included for :-(i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample (xi) All existing earthing of the lifts shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engr-in-Charge. Please Enable Macros to View BoQ information |