| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair /Maint of LT Cable Network at CHNC and other areas under GE (Utilities) Udhampur Contract No: GE/U-03/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Taking out old defective LT UG cable from trenches /floors/ road/wall/pole/pipe of any size descripitonincluding disconnecting the connection from OH lines and main DB, complete all as specified and directed by Engineer-in-charge |
| 3 | S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 400 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge |
| 4 | S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 240 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge |
| 5 | S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 185 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge |
| 6 | S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 150 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge |
| 7 | S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 70 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge |
| 8 | S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 35 sqmm 3.5 core , complete all as specified and directed by Engineer-in-charge |
| 9 | S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 25 sqmm 3.5 core, complete all as specified and directed by Engineer-in-charge |
| 10 | S&F XLPE LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 16 sqmm 2 core, complete all as specified and directed by Engineer-in-charge |
| 11 | Supply and fixing GI pipe light grade 80 mm bore for cable protection fixed to poles with clamps/along wall/floor/under road/across the drain or nallah all as specified and directed by Engineer-in-Charge. |
| 12 | Material and labour for making the hole under road and hard standing suitable for laying and inserting pipe upto 100 mm dia any length by mechanical drill system or Auger system and making the surface good as existing surface.complete all as specified and as directed by Engineer-in-charge. |
| 13 | Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for taking out of unserviceble /laying new LT under ground cable, complete all as specified and directed by Engineer-in-charge |
| 14 | Returning, filling in,including spreding ,levelling ,watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed by Engineer-in-charge. |
| 15 | Removal of surplus excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete all as specified and directed by Engineer-in-charge. |
| 16 | S&F double walled corrugated (DWC) pipe of size 90/76 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground , complete all as specified and directed by Engineer-in-charge. |
| 17 | S&F double walled corrugated (DWC) pipe of size 77/63 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground , complete all as specified and directed by Engineer-in-charge. |
| 18 | Opening / disconnecting the electrical connection of defective / burnt out underground LT cable of any size 2 to 4 core from main switch/DB/Junction boxes LT OH Line,taking out the required length of cable from existing loop,cutting the defective portion of cable, providing required thimbles/connectors at cable end and reconnecting the cable in previous location with existing main switch/DB/Junction boxes LT/OH Line etc , complete all as specified and directed by Engineer-in-charge. Note (i) The cost of required earth work ie excavation,returning filling relaying of sand and bricks and cost of drawing the required length from protection pipe breaking of required brick work/plaster/concrete and redoing the required work to match the existing surface is deemed to be included in quoted rates and nothing extra should be paid on this account (ii) Additional cable/protection pipe required at stie if any shall be measured and paid separately. |
| 19 | Supply and fixing in replacement of MCCB, 4 pole, 415 volt of capacity 630 amp,Ics=50%Icu short circuit, breaking capacity not less than 50 KA , thermal setting 80 to 100 % confirming to IEC-947, IS-13947 , including thimbles, nuts, bolts ,washers etc disconnecting and making incoming , out going connections , complete all as specified and directed by Engineer-in-charge. |
| 20 | Supply and fixing in replacement of MCCB, 3 phase, 4 pole, 415 volts of capacity 400 Amps, breaking capacity not less than 35/36 KA, thermal setting 80-100%, Ics=100% Icu conforming to IEC-947, IS-13947 including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections, complete all as specified and directed by Engr-in-Charge. |
| 21 | Description all as per Ser item No 19.00 here-in- before but capacity of MCCB 250 Amps 25 KA . |
| 22 | Description all as per Ser item No 19.00 here-in- before but capacity of MCCB 200 Amps 25 KA. |
| 23 | Description all as per Ser item No 19.00 here-in- before but capacity of MCCB 160 Amps 25 KA. |
| 24 | Description all as per Ser item No 19.00 here-in- before but capacity of MCCB 100 Amps 25 KA. |
| 25 | Description all as per Ser item No 19.00 here-in- before but capacity of MCCB 63 Amps 25 KA. |
| 26 | Supply and fix MCB TPN 415 volts 63 amps with 10KA breaking capacity complete all as specified and directed by Engineer-in-charge |
| 27 | M&L in replacement of Aluminium lugs suitable for 300 Sqmm Copper cable including taking down the existing unserviceable one complete all as specified and directed by Engineer-in-Charge. |
| 28 | Description all as per Ser item No 26.00 here-in- before but size of 240 SQMM |
| 29 | Description all as per Ser item No 26.00 here-in- before but size of 185 SQMM |
| 30 | Description all as per Ser item No 26.00 here-in- before but size of 120 SQMM |
| 31 | Description all as per Ser item No 26.00 here-in- before but size of 95 SQMM |
| 32 | Description all as per Ser item No 26.00 here-in- before but size of 70 SQMM |
| 33 | Description all as per Ser item No 26.00 here-in- before but size of 50 SQMM |
| 34 | Material and Labour for earthing complete with galvanized iron of street or earth plate of size 60cmx60cmx6 mm thick buried directly in ground. Vertically total depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surounded from all sides with alternate layers of charcoal and common salt and connected to GI earth strip 32x6 mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer ( including making of test point with GI strip of size 32x6 mm) including GI protection pipe 40 mm light grade dia for protection of strip upto test point all as directed GI pipe medium grade 20 mm bore for watering including providing funnel and wire mesh CI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40 mm graded stone aggredates complete including excavation and earth work, all as specified and show in plate No 3 of SRR-2009 Part-1, PCC pit shall be provided at least 50cm away from the earth pit and not just on earth pit including testing on completion, complete all as specified and directed by Engineer-in-Charge. |
| 35 | M&L in replacement of PVC insulation tape roll 25 mm X 25 Mtr (LT) including taking down the existing unserviceable one, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Opening, maintenance and general servicing of servo voltage stabilizer of capacity 1250 kVA incuding removal of sludge from disserstate coils, buck boost transfomers, tightening of all nuts and bolts, cleaning of stabilzer coils, checking and servicing of servo mechanisam, gear, syncronising system, automatic voltage regulator circuits and other allied electrical components complete all as specified and directed by Engineer-in-Charge. Note: (a) The entire work shall be got executed through OEM i.e. M/s Electric Instrumentation only. b) Voltage stabilizer must be repaired by original manufacturer or by authorised service provider of the company. c) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item d) All T & P and transportaion arrangement are deemed to be included in the rates quoted. |
| 37 | Supply only following parts suitable for three phase servo voltage stabilizer 1250 kVA capacity as per existing make or as recommanded by original stabilizer manufacturer ie M/s Electric Instrumentation only, complete all as specified and directed by Engineer-in-Charge. |
| 38 | Control card H-999 |
| 39 | Control card J-1195 |
| 40 | THH Transformer T-HH |
| 41 | Step Syn Motor 20kg SS-202 |
| 42 | RFP Card REP-301 |
| 43 | Pot meter 5k 1W |
| 44 | Carbon Brush |
| 45 | Tension spring |
| 46 | E-Wire 200 AMPS |
| 47 | Carbon brush holder |
| 48 | M&L for Dehydration including filtration and cleaning of Servo Voltage Stabilizer oil by dehydrating machine incl testing of sample before and after dehydration and filtration complete all as specified and directed by Engineer-in-Charge. NOTE:- dehydration machine and testing kit will be provided by the Cont.Sample testing will be carried out in the presence of Engr-in-Charge on site. |
| 49 | Supply & Filling /pouring of up to the appropriate level Servo Voltage Stabilizer oil of low viscosity having dielectric strength not less than 60 KV complete all as specified and directed by Engineer-in-Charge. NOTE:- Dielectric strength test shall be carried out at site before poring/filling in Servo Voltage Stabilizer in the presence of Engr-in-Charge on the site. |
| 50 | M & L Preparing surfaces of Servo Voltage Stabilizercomplete body and applying painting two coats of superior quality synthetic enamel paint using spray gun including sticker work and writing of MES/SM Nos etc, complete all as specified and directed by Engineer-in-Charge. |
| 51 | Supply and fixing LT junction box cubical type of size 60x40x30 cm,415 volts for outdoor use made out of CRCA sheet 3.15 mm thick powder coated ,machine pressed front opening with single door with provision of rubber beading and locking system including aluminium bus bar 4 strip of size 30 mm wide and 6 mm thick with provision of hole on bus bar fixing of cable mounted on PVC / epoxy insulators, mounted on angle legs of size 25x25x5mm frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer ,legs grouted in PCC(1:2:4) Type B-1 (using 20 mm graded stone aggregate) complete including all provision of opening for incomming/outgoing cables and testing, complete all as specified and directed by Engineer-in-Charge. |
| 52 | M&L for reparing/servicing of APFC panel board of Cap 300 kVAR by replacing the all defective components with new components, rewiring, cleaning, testing, reconnecting, reinstalling and commisssioning the APFC panel boad complete all as specified and directed by Engineer-in-Charge. Note : a) Spare parts required for replacement will be measured and paid for separately under respective items of schedule labour for fixing parts is included in the unit rate of item. b) All T & P and transportaion arrangement are deemed to be included in the rates quoted. |
| 53 | S&F in replacement of VIF meter complete all as specified and directed by Engineer-in-Charge. |
| 54 | S&F in replacement of MCB TP 63A 10kA complete all as specified and directed by Engineer-in-Charge. |
| 55 | S&F in existing panel of Capacitors mixed dielectric type 3Ph 440v AC 12.5 KVAR, complete all as specified and directed by Engineer-in-Charge. Make Schneider |
| 56 | S&F in existing panel of LED indication lamps 230VAC SP R Phase, complete all as specified and directed by Engineer-in-Charge. |
| 57 | S&F in existing panel of LED indication lamps 230VAC SP Y Phase, complete all as specified and directed by Engineer-in-Charge. |
| 58 | S&F in existing panel of LED indication lamps 230VAC SP B Phase, complete all as specified and directed by Engineer-in-Charge. |
| 59 | S&F in existing panel of APFC Relay 12 Stage, complete all as specified and directed by Engineer-in-Charge. |
| 60 | Calliberation of APFC Relay , complete all as specified and directed by Engineer-in-Charge. |
| 61 | S&F in existing panel of capacitor switching duty contactor suitable for 12.5 KVAR, complete all as specified and directed by Engineer-in-Charge. |
| 62 | S&F new 2 HP monoblock pump set drip proof, capacitor start, continuous duty rated, thermally protectd fluid temp to 220 degree F (104 Degree C), Body/Impellers - Noryl, 230 Vots, 50 Hz Flow rate Range to 40 gpm Maximum head 50 feet complete all as specified and directed by Engineer-in-Charge. Make : Kirlosker/Crompton/Mather & Plantt/KSB. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |