| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE NEW DELHI Name of Work: MAINT/ REPAIR OF FENCING, BOUNDARY WALL, DRAINAGE, HARDSTANDING, SEWER LINE, MANHOLES, CLEANING OF SEWER LINE APPURTENANCES AND SEWAGE LINE IN CHANAKYA BAGH AND NARAINA BAGH UNDER GE NEW DELHI Contract No: GE/ND-120/2025-26 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Cleaning, Flushing of chocked and desilting of outdoor sewage lines of 300mm internal diameter of any depth upto three meter. The cleaning shall be carried out with mechanized operation by means of diesal/electric operated vehicle mounted hydraulic operated high pressure suction cum jetting machines fitted with pump of requisite capacty and the sludge sucked out with super succer machine of required capacity and sent to storage tanks for further disposal to the authorised disposal site. the sludge deposited in the sewage ling shall be fully ceaned and disposed off the same outside the MoD land at any distance and without any additional cost on the same day when it was taken out. The job shall be carried out with safety precaution equipments and with strick supervision complete all as specified and directed by Engr in charge. Note:- (a) The service proider/contractor during the mechanised operation shall be equiped with gas monitor, nylon rope ladder, torch light and compressor blower etc along with the sewage cleaning truck mounted suction/jetting machine.(b) Manual cleaning operation/scavenging is prohibited.(c) The unit rate quoted by the contractor shall deem to include the cost of providing skilled driver and operator and supervising Engineer including provision of water for jetting and removal of sludge/stilt/liquid/mud and sand (in fou position) etc. |
| 3 | Desluding of existing manholes of depth upto 2 mtr (vol of MH exc 0.20 cum but not exc 2.88 cum) for liquid, solids and slurry material by machanical means using hydraulic operated high pressure suction cum jetting sewer cleaning machine having jetting tank capacity of minimum 5000 ltr and suction tank capacity of 300 ltrs and 260 LPM with minimum 145 bar suction flow of 10200 LPM including skilled driver and operator and supervising Engineer including provison of water for jetting and removal of sludge/silt/liquid/mud abd sand (in foul position) etc removed to outside the MoD land/premises at any distance all as directed by engr-in-charge incluidng loading, unloading, digging outt pit of any size in any type of soil, surring sludge/stilt/spoil/mud etc into the pit and sprreying bleaching power over the entire surface complete all as specified and directed. Note:- (a) The service provider/contractorduring the mechanized operation shall be equiped with gas monitor, nylon rope ladder, torch light and compressor blower etc along with the sewage cleaning truck mounted suction/jetting machine.(b) The cleaning shall be carried out with machanised operation by means of jetting machines and the sludge sucked out with super succer machine of required capacity and sent to storage tanks for further disposal to the authorised disposal site. (c) Manual cleaning operation/scavenging is prohibited.(d) The unit rate shall deem to include for all material, labour and skilled/unskilled) tools and plants and requisite quantity of water for the entire operation and transpotation arrangements. |
| 4 | Desludging including dewatering of septic tank/soak well in dia/ greese trap depth and manholes above 2 mtr in depth for liquid and slurry material and removing the sludge from the tank by machanical using hydraulic operated high pressure suction cum jetting sewer cleaning machine having jetting tank capacity of minimum 5000 ltr andsuction tank capacity of 300 ltrs and 260 LPM with minimum 145 bar suction flow of 10200 LPM including skiled driver and operator abd supervising Engineer including provition of water for jetting and removal of sludge/ silt/ liquid/ mud and sand (in foul position) etc out side the MoD land/premises at any distance all as directed by Engr-in-Charge including loading, unloading digging out pit of any size in any type of soil, surring sludge/silt/spoil/mud tec into the pit and spreying bleaching powder over the entire surface complete all as specified and directed by Engg in charge.Note:- (a) The service provider/contractorduring the mechanized operation shall be equiped with gas monitor, nylon rope ladder, torch light and compressor blower etc along with the sewage cleaning truck mounted suction/jetting machine.(b) The cleaning shall be carried out with machanised operation by means of jetting machines and the sludge sucked out with super succer machine of required capacity and sent to storage tanks for further disposal to the authorised disposal site. (c) Manual cleaning operation/scavenging is prohibited.(d) The unit rate shall deem to include for all material, labour 9skilled/unskilled) tools and plants and requisite quantity of water for the entire operation and transpotation arrangements.(e) The measurement shall be included with depth of water and sludge/silt/mud. |
| 5 | Cleaning of manhole and removing the blockage sludge from manhole by manually with the help of bampos/rods/pipes incluidng rodding and flushing the water and dispose off the sludge out side of MoD land complete all as directed at site for any size, description of manhole up to 1.5 m internal depth complete all as specified and directed. |
| 6 | Cleaning of sewer line and removing the blockage by manually with the help of bampoos/rods/pipes including rodding and flushing the water and dispose off tge sludge out side the MoD land of 150 to 200 mm dia pipes complete all as specified and directed. |
| 7 | M&L for cleaning of all blockages of Nahani traps/ floor traps/ bottle traps, blockages of WC's, Rain water pipes, Rain water spouts at roof level, 100 mm dia CI pipes upto 1st manhole/GT in shafts, vertical CI soil/waste pipe stacks, CI Tee/door bends etc & cleaning of drain pipes 150 mm to 250 mm internal dia by rodding and manholes upto 3.0 metre in depth and removal of sludge/silt/liquid mud sand (in foul conditions) etc, out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) complete all as specified and directed by the Engineer-in-Charge to maintain internal & external sewage system in functional state at all the time. The contractor shall engage required skilled manpower and provide all necessary tools and plants (manual/pressure cleaning pump and flexible rods and other necessary equipment (as per rules of public health), etc to ensure resolution of complaint in time frame as desired by Engineer-in-Charge.Any type of complaint related to cleaning of sewage line and other connected items need to be catered for by the contractor complete all as specified and directed.Note :- (a) Contractor may have to deploy more manpower in the particular area and deploy adequate sewage cleaning machinery/ equipment to clean the line and open blockages within 06 hours of complaint received (on same day). (b) In case contractor fails to get the complaint rectified within 06 hours of complaint received, he shall be penalised for the same at a flat rate of Rs 200/- per complaint , in addition to cost incurred by the department for rectification of complaints from third party. (c) Proper records (date wise) of complaints received & rectified by the contractor shall be maintained and shall be produced for verification at the time of payment of each RAR/Bill.Note :- Day to day Complaint received from user's should be resolved within 06 hours of complaint received. Note :- Removing building materials /old waste unwanted existing material of any description or any type etc. to a distance of 5km or beyond out side MOD Land and the cost for the same is deemed to be included in the quoted unit rates.(d) The contractor must keep in mind the above said provisions while quoting his rates. |
| 8 | Demolition of cement concrete in ground floor and pavings not exc 15 cm in thick below or above ground level complete all as specified and directed. |
| 9 | Demoletion and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) any size and set in cement mortar complete all as specified and directed by Engr in Charge. |
| 10 | M&L for cement concrete 1:3:6 type C-2 in bed to drain pipes incls packing under, and haunching against the sides of pipes after they are laid and tested of bore 150mm dia drain pipe complete all as specified and directed by Engr in charge. |
| 11 | M&L for cement concrete 1:3:6 type C-2 in bed to drain pipes incls packing under, and haunching against the sides of pipes after they are laid and tested of bore 200mm dia drain pipe complete all as specified and directed by Engr in charge. |
| 12 | M&L for cement concrete 1:3:6 type C-2 in bed to drain pipes incls packing under, and haunching against the sides of pipes after they are laid and tested of bore 300mm dia drain pipe complete all as specified and directed by Engr in charge. |
| 13 | S&F 150 mm bore dia SGSW drain pipe laid in trenches and jointed complete all as specified and directed by Engr in Charge. |
| 14 | S&F 200mm dia Reinforced concrete pipes, class NP-2 laid and jointed complete all as specified and directed. |
| 15 | S&F 300mm dia Reinforced concrete pipes, class NP-2 laid and jointed complete all as specified and directed. |
| 16 | S&F 600mm dia Reinforced concrete pipes ,class NP-2 laid and jointed including cement concrete bed 1:3:6 type C2 in drain pipes complete all as specified and directed. |
| 17 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for fdn etc in any type of soil complete all as specified and directed. |
| 18 | All as per item No 15.00 above depth exceeding 1.5 mtr complete all as specified and directed. |
| 19 | Returning filling in, including, spreading, levelling, watering, and well ramming in layers not exc. 25cm complete all as specified and directed. |
| 20 | Removing excavated materials/surplus soil out side of defence land up to a total distance of 1.5 Km complete all as specified and directed. |
| 21 | Demolition of brick work or stone/ boulder masonary built in cement mortar or cement lime mortar complete all as specified and directed. |
| 22 | M&L for brick work with sub class B bricks straight or curved on plan exc. 6 meter mean radius built in cement mortar 1:6 complete all as specified and directed by Engg in charge. |
| 23 | M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggragated) as in benchning, copings, channels, slightly chamfered or rounded on edge including necessary use of form work complete all as specified and directed. |
| 24 | M&L for Rendering 15 mm thick in cement mortar 1:4, on fair faces of brick work or cement concrete surfaces, finished even and smooth without using extra complete all as specified and directed.cement. |
| 25 | Taking down cement plaster on brick wall any description incl racking out joint, hacking for key, scrubbing down with water complete rubbish out of MOD land complete all as specified and directed. |
| 26 | Demolition of RCC manhole cover slabs and similar suspended work incl (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 27 | S&F MS framed brackets of angle iron or of flat iron/ guard bars/ plates with hold fasts or as in grating/ tank cover/ tank staging etc as directed incl necessary welding etc complete for manholes and covers confirming to Fe-410-0 or Fe-310-0 complete all as specified and directed. |
| 28 | S&F precast RCC 1:2:4 manhole covers slabs any size, thickness with 3 mm thick FL around cover slab complete all as specified Make PPRC, polycrete including reinforcement as per manufacture design with frame complete all as specified and directed. |
| 29 | M&L for Cutting into existing manholes for connecting new drain making good to pipe and rendering cutting out existing benching for and forming channel (1/2 or 3/4 section) in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate finishing smooth and refrming benching as required for 150/200 mm dia pipes complete all as specified and directed. |
| 30 | S&F in repair Cast iron floor trap of size 75mm, with grating including jointing to waste pipe fixed in cement concrete type B-1(1:2:4:), complete all as specified and directed. |
| 31 | S&F in repair salt glazed stone ware gully trap of size 180X150 mm squire or rounded mouthed,type \\"P\\" complete all as specified and directed. |
| 32 | Dismantling of cast iron or reinforced concrete drain pipe 100/75mm bore, jointed in cement mottor and taking out of treanches if required complete all as specified and directed. |
| 33 | S&F Cast iron soil, waste and vent sand cast pipes pipes in any length with or without ears, with cement joints, laid in trenches or in floors of size 100 mm bore complete all as specified and directed. |
| 34 | S&F Cast iron soil,waste and vent sand cast pipes pipes in any length with or without ears, with cement joints, laid in trenches or in floors of size 75 mm bore complete all as specified and directed |
| 35 | S&F in repair Cast iron bends (any radius) with ducks foot or heel rest.of size 100mm bore of pipe complete all as specified and directed. |
| 36 | S&F in repair Cast iron bends (any radius) with ducks foot or heel rest.of size 75mm bore of pipe complete all as speciifed and directed. |
| 37 | Demolition of cement concrete (unreinforced) of any description as in any position and removing rubbish off the premisses ouside MOD land complete all as specified and directed. |
| 38 | M&L for cement concrete in filling mass concrete as in sub base type C2 1:3:6 (40mm graded aggregate) complete all as specified and directed. |
| 39 | Dismantlling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 40 | M&L for 10-12 mm thick heavy duty parking tiles 400x400 mm of any pattern decided by Engr in charge as in pavings laid over 20 mm thick screed bed 1:4 laid and jointed with cement slurry mixed with pigments to match the shade of tiles complete all as specified and directed. Make Johnson/Kajaria/Somany |
| 41 | S&F in repair 2.24mm barbed with 2mm dia barbs at 75mm spacing galvanised, 2 strand, in fencing including straining and fixing to wood concrete or steel posts or straining bolts, incluidng securing with provision of galvanised iron tying wire, galvanised iron tying wire (each line of wire to be measured) complete all as specified and directed. |
| 42 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick ( square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 sqm, in floors etc. in patches set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed in Cement mortar 1:6 as in floor complete all as specified and directed. |
| 43 | M&L for non skid ceramic coloured tiles 7 to 8 mm thick ( square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc. in patches set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15 mm thick screed in Cement mortar 1:6 as in floor complete all as specified and directed. |
| 44 | M&L for glazed ceramic coloured tiles in vertical surface 450 x 300 x 7 mm thick over 10 mm thick rendering 1:4 CM set and jointed in neat cement slurry and pointed in white or colour cement to match coloured tiles complete all as specified and directed. |
| 45 | M&L for Non skid joint less coloured DGVT matt finished tiles 8 to 10mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm (600x600mm), in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 46 | S&F in repairs, wash hand basin vitreous china white, (flat back or angle back type) of size 550X400 mm including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 47 | S&F in repairs, wash hand basin vitreous china white, Oval shape of any size including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 48 | S&F in repair Vitreous china squatting pan of 'Orissa pattern' long pan size 580 x 440 mm white with integral foot rest incl ‘P’ or ‘S’ trap and flush pipe etc complete all as specified and directed. |
| 49 | S&F in repair Vitreous China wash down water closet pan with seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe)including sheet cover complete all as specified and directed. |
| 50 | S&F in repairs, 10 Ltrs capacity PVC valveless, syphonic action type, flushing cisterm, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. Make:- cera/Hindware/Parryware |
| 51 | S&F in repair concertina coil 450 mm dia for fixing on boundary wall complete all as specified and directed. |
| 52 | Dismantling plain or corrugated steel sheeting, in any pattern, any guage, complete all as specified and directed. |
| 53 | S&F Pre-painted galvatume aluminium zince coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 54 | M&L for 25mm thick cement concrete type B-0,1:2:4 (12.5mm graded aggregate) as in sub bsae floor complete all as specified and directed. |
| 55 | Dismantling stone slab or paver block of any description or thickness in floors laid dry aprons etc complete all as specified and directed. |
| 56 | M&L for Granite (of any type) 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, including 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engg in charge. |
| 57 | M&L for rounding the edges of stone slabs one edge, such as steps, cooking platform, and other similar situations complete all as specifeid and directed by Engr in charge. |
| 58 | M&L for L 22-25 mm thick Red Agra sand stone as in wall cladding, steps, footpath gang saw machine cut edges , polished, over 20mm thick cement screed in CM 1:4,set and jointed in cement mortar 1:3 and pointed in cement mixed with approved pigment to match the colour of the stone ( Note: Size and colour of stone to be matched with existing stone) complete all as specified and directed by Engg in charge. |
| 59 | M&L for 22-25 mm thick Dholpur stone as in wall cladding, steps, footpath gang saw machine cut edges , polished, over 20mm thick cement screed in CM 1:4,set and jointed in cement mortar 1:3 and pointed in cement mixed with approved pigment to match the colour of the stone ( Note:- Size and colour of stone to be matched with existing stone) complete all as specified and directed. |
| 60 | M&L for machine pressed precast concrete interloking paver block coloured glossy finished with grey cement and pigments any shape and size confirming to IS 15658 - 2006 of 80 mm thick M-40 grade including coarse sand of required thickness for laying of paver block complete all as specified and directed. |
| 61 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 62 | Dismantling fencing wire mesh/ chain link fencing, any type complete all as specified and directed. |
| 63 | M&L for mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 64 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire complete all as specifeid and directed. |
| 65 | Supply onlyr Chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 66 | M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces of any description complete all as specified and directed. Note: (a) Srl Item No 12.00 to 15.00, 21.00 to 23.00, 26.00, 32.00, 33.00, 39.00 to 44.00, 52.00, 55.00, 57.00 to 59.00 & 62.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody.(b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |