| Sl. No. | Item Description |
| 1 | Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. |
| 2 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc. all as specified and as directed for the followings:- |
| 3 | One light/exhaust fan point controlled by one way switch |
| 4 | One bell/buzzer point controlled by one bell push |
| 5 | One light point controlled by two Nos two way switches |
| 6 | One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board. |
| 7 | One 3 pin 5 Amps socket outlet point controlled by one way switch on same board |
| 8 | All as per item No 2 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge |
| 9 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box/M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate/3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc. all as specified and as directed for the followings:- |
| 10 | One light/fan point controlled by one way switch |
| 11 | One bell /buzzer point controlled by one bell push |
| 12 | One light point controlled by two Nos two way switches |
| 13 | One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board. |
| 14 | One 3 pin 5 Amps socket outlet point controlled by one way switch on same board |
| 15 | All as per item No 4 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge. |
| 16 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 1module/2 module concealed in walls with suitable modular inner and outer plate for housing switches, socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately |
| 17 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 3 module/4 module concealed in walls with suitable modular inner and outer plate for housing switches, socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately |
| 18 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 6 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc. including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately |
| 19 | Taking down old unserviceable MS Steel terminal boxes from wall and supply and fixing fabricated branded modular metal flush box 8 module concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc including make good of disturbed surface complete all as specified and directed by Engineer in charge. Note-Switch,socket, regulator will be paid separately |
| 20 | M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 21 | M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge. |
| 22 | M&L in replacement Modular Bell push button SP, 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 23 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 24 | M&L in replacement switch Modular type 16 Amps 1 way, 1 module with modular plate 230V AC complete all as specified and directed by Engineer in charge. |
| 25 | M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 26 | M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge. |
| 27 | M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge. |
| 28 | M&L in replacement switch piano flush button type single pole two way 6 Amps complete all as specified and directed by Engineer in charge. |
| 29 | M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge. |
| 30 | M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge . |
| 31 | M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. |
| 32 | M&L in replacement socket outlet 5 pin 6 Amp flush button type complete all as specified and directed by Engineer in charge. |
| 33 | M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed. |
| 34 | M&L in replacement bell electric (ding dong) 230 volt, SP all complete all as specified and directed by Engineer in charge . |
| 35 | M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge. |
| 36 | S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge. |
| 37 | M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge. |
| 38 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, IP-20 protected,voltage range-180 to 270 Volts AC, temperature range 0 to 45 Degree C minimum and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. |
| 39 | Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and IP- 20 protected,voltage range - 180 to 270 volts AC, temperature range 0 to 45 Degree C minimum, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed. |
| 40 | S&F LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3600lm with Metallic CRCA powder coated body,ambient temperature 0 to 50 Deg C, voltage variation range of 150-270 V including necessary fixing arrangementsfixed complete all as specified and directed. |
| 41 | Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, driver with Voltage range 180-270V, Temperature range 0 to 45 Deg minimum, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire complete all as specified and directed. |
| 42 | S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge. |
| 43 | Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 100 Lumens/watt, driver with voltage variation range - 180 to 270 Volts AC and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire complete all as specified and directed. |
| 44 | Supply and fixing LED light fitting 1x16 watt flame proof CMRI certified recommended for explosive depot/ amunition stores IP-65 protection with diecast aluminium housing with heat resistant tougned glass with LED tube light fixtures, driver, holders, connector etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 45 | S&F 35W high efficient LED street light fitting with pressure die cast Aluminum housing and has lenses for street lighting with polycarbonate cover. The luminaire is IP-65 protected,voltage variation range 180-270V,including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 46 | M & L for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out / unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge. |
| 47 | Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 48 | Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 49 | Supply and fix in repair MCB SPN 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge. |
| 50 | Supply and fix in repair MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge. |
| 51 | Supply and fix in repair MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge. |
| 52 | Supply and fixing ventilating fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 53 | Supply and fixing ventilating fan 200 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 54 | Supply and fixing exhaust fan 450 mm sweep (steel Body), 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 55 | Supply and fix wall mounted fan 400mm, 230 volts, 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed. |
| 56 | S & F water heater storage type (Geyser) steel body, vertical type with suitable size of fastner and including provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure complete all as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating with minimum two year warrant on product.Note : old unservicable geyser will be deposoted in MES yard. conversion against low rating to 5 star rating. |
| 57 | Supply and fixing wall mounted angular electric chimney black colour of suction power not less than not less than 1200Cum/Hr,Al casette with stainless steel outer layer, touch control panel,3 speed motor with 250 watt with decorative smart cooker hood SS and glass, energy efficent LED light with digital display, including ducting not less than 12 feet as per site required complete all as specified and as directed by Engr-in-Charge. |
| 58 | Supply and fixing ceiling fans complete with blade, down rods, with remote and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM, BEE five star rated voltage range 180 - 270 volts with brushess direct current motor (BLDC) all as specified and directed by Engr in Charge. (Against BLDC converson). Old fan shall be deposited to MES store yard. |
| 59 | S&F in repair sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. |
| 60 | M&L for fan motor of ventilating fan 250/300mm sweep plastic body operated on single phase 230 volts 50Hz electric supply as per sample complete including making necessary electrical connections and testing on site after replacement all as specified and directed by Engr-in-Charge at site. |
| 61 | Supply and fix in repair sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. |
| 62 | Supply and fix in repair sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. |
| 63 | Supply and fix in repair sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. |
| 64 | S&F plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge. |
| 65 | S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge . |
| 66 | S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 67 | S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 68 | S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge. |
| 69 | M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 70 | M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 71 | M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 72 | M & L in replacement for only single core PVC insulated cable 6 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 73 | M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 74 | M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge. |
| 75 | Supply and fixing LED Bollard integral decorative with PMMA diffuser 10 watt of height not less than 0.6 meter with IP 65 protection suitable for single phase 230 volts 50 HZ AC Supply including LED bulb , Poles, service wire and cement work complete all as specified and directed by Engineer-in-Charge. |
| 76 | Supply and fixing new generation, post top energy saving environmently friendly 25W , long life aesthetically designed with symmetrical light distribuiton spun aluminium landscape luminaire with high power LED as light sources. |
| 77 | Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed. |
| 78 | Supply only heating element of 2 KW any type with nut bolt washer complete all as directed. |
| 79 | Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed. |
| 80 | Supply only replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed. |
| 81 | Taking down MCB distribution board of any rating/type/size or other descriptions. |
| 82 | Taking down MCBs/MCCBs of any rating/type/size or other descriptions. |
| 83 | Supply and fix MCB DB SPN 8 way Horizontal, IP-43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link complete. |
| 84 | Supply and fix MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link complete all as directed by Engineer -in- Charge. |
| 85 | Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.Note : MCCB to be measured and paid separately. |
| 86 | Supply and fixing MCCB 160 Amps, four pole 415 volts 25 KA 50 HZ with thermal magnetic setting complete including making necessary electrical connections all as specified and directed. |
| 87 | Supply and fixing in replacement 415V, 10KA 'B' curve miniature circuit breaker (MCB) of three pole and neutral and current carrying capacity 16 to 32 amps complete with connection testing and commissioning. |
| 88 | Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 89 | Supply and fix in repair MCCB 250 Amps, FP 415 volts 25 16KA, 4 pole 50 HZ with thermal magnetic setting complete all as specified and directed. |
| 90 | M&L for glow sign board made out of chromium nickle based stainless steel frame 304 grade of size 1.50 Mtr x1.50 Mtr and height not less than 3 mtr fabricated with stainless steel frame and pipe of 40mm dia and sheet not less than 3mm thick and mounted/erected on SS pipe of 40mm and writing letter with white radium shade on navy blue background as “SEWAGE INSTALLATION, MILITARY ENGINEER SERVICES, AGE E/M (CENTRAL), GARRISON ENGINEER (CENTRAL) DELHI CANTT” of suitable size as directed by Engr-in-Charge and fixing/grouting it at suitable height including mounting bracket/legs fixed into ground or as directed at site by Engr-in- Chrage and including of all welding/grouting in PCC and other materials all as required at site and testing on completion of job. |
| 91 | S&F not less than 60 Watt High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP-66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.90, voltage variation range 180-270V, THD<10%, high and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall complete as specified and directed. |
| 92 | GI bracket 40mm/50mm bend to shape including clamps,nuts, bolts and washers and grouting in wall and painting with two coats of black enamelled paint over a red of red oxide primer all as specified. |
| 93 | M&L copper three core cable 1.5 sqmm for connecting street light with connector all as directed. |
| 94 | Taking down of old unsv garden/gate light fittings of any description including service connection/wires of any dia or size and accessories etc complete. |
| 95 | Supply, installing, testing and commissioning factory made and tested LT Panel Indoor type, platform mounted of size: 800 X 200 X 1200 mm ( LxWxH ) suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Copper bus bars of capacity 250 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof, IP-42 and made out of 2.00 mm thick CRCA mild steel sheet Wall mounted type, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade complete all as specified and directed by Engineer-in-Charge. The scope of work also comprising of the following:- BUS BAR CHAMBER:- (a) 250 Amp TPN, Copper conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER:- (i) Volt Meter,96mm,flush type rated 0-500V, Digital type with Volt Meter selector switch- 01 Set. (ii) Amp Meter,96mm,flush type rated 0-200A, Digital type with suitable size C.T's, and Amp Selector switch- 01 Set (iii) RYB Phase indicating light LED type with MCB 2A SP C Series- 1 Set of three. INCOMING:- (i) MCCB 160 Amps 25 KA , 4 Pole with adjustable thermal magnetic release=01 No., Make of MCCB:- Siemens / Legrand/ Schneider.OUTGOING:- (i) MCB 2 Pole 63 Amps, 415 volts , 50Hz, 10 KA = 04 Nos. (ii) MCB 2 Pole 10 Amps, 415 volts , 50Hz, 10 KA = 01 Nos. (iii) Provision for Prepaid meter (Meter provided by MES ) (v) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 10 Sqmm flexible.Note :- (i) Marking of Flat Nos on outgoing feeders of LT Panel. (ii) Time duration for replacement of LT Panel should not be more than 4 Hours. (iii) Rate quoted are deemed to be inclusive of all the fixture /fittings cater above |
| 96 | Supply and fix 7 mtr octagonal pole with base plate and J bolts. |
| 97 | M&L for plain cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in foundation of pole and mass concrete complete all as specified and directed. |
| 98 | M&L for cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in foundation of stay and coping around poles complete all as specified and directed. |
| 99 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or secring with clips. |
| 100 | M&L for machine pressed precast concrete chemically treated interlock paver block of any shape, size and colourconfirming to IS 15658-2006 of 60mm thickness M-35 grade including 25mm thick sand cushion complete all as specified and directed by Engineer-in-Charge. |
| 101 | M&L PCC 1:2:4 type B-2 using 40mm graded stone aggregate as in floor finish even and smooth of thickness 50mm including demolition etc all as specified and directedd. |
| 102 | Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene (XLPE Cable) insulated,10 sqmm 2 core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutlistranded, heavy duty 1100 Volts grade complete all as specified laid in trenches / laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items). |
| 103 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundations etc. or for shafts, well cess pits, manholes, pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing /trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified. |
| 104 | Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified. |
| 105 | Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified. |
| 106 | Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified. |
| 107 | Supply, laying and jointing (HDPE) of 40mm dia and pressure rating 6 kgf/cm2 for cable protection including tee,bend,elbow and other accessories complete all as specified and directed |
| 108 | M&L for PCC 1:3:6 type C1 using 20mm aggregate for light foundation etc complete all as specified and directed. |
| 109 | Supply and fixing MCCB 250 Amps, four pole 415 volts 25 KA 50 HZ with thermal magnetic setting complete including making necessary electrical connections all as specified and directed. |
| 110 | Supply and fixing cast aluminium/cast iron decorative pole suitable for land scapining type of height not less than 2.165 mtr including PCC foundation of suitable ratio and depth not ness than 45cms and nuts, bolts and washers grouted in PCC foundation to erect the pole vertically and making light connections all as specified and directed. |
| 111 | Supply and fixing post top light fittings cast aluminium base, spun aluminium top, acrylic diffuser, stainless screws, corroson and UV rays rasistant coating complete type with LED lamp 40 watt and making necessary electrical connection with suitable size copper multistranded cable 1100 volts grade and testin on completion all as specified and directed by Engr-in-Charge. |
| 112 | Supply,installation,testing and commissioning of self priming regenerative pump with pressure control device, 0.5/0.37 HP/KW, single Phase 220 volt+18%, discharge range 1950-450 LPH, head range 6-21 mtr insulation class ‘F’ of size 25x25mm complete including mounting bracket of angle iron of suitable size with necessary nuts, bolts and washer etc and making electrical connection with suitable size copper multi stranded cable of suitable length and connecting with GI/ uPVC/cPVC water supply line of any dia/size alongwith accessories such as tee,bend, elbow and socket etc including making bypass arrangement for any fault in pump in future to provide uniterrupted water supply to building all as specified and directed at site by Engr-in-Charge. |
| 113 | Supply installation testing and commissioning of prepaid meter single phase, 2 wire 5-60A capacity,240 volts,50Hz, class-1.0 rating,IS 15884:2024, encased meter of protective class-II,load switching utilization category UC3 with key pad based token carrier interface including freedom device complete all as specified and directed. Model: Liberty 170 of make Secure. |
| 114 | Supply, laying, connecting and testing twin flat PVC insulated cable 10Sqmm 1100 Volts with aluminium multi stranded conductor two core suitable for service connection all as specified and directed by Engr-in-Charge. |
| 115 | Supply, laying, connecting and testing twin flat PVC insulated cable 6 sqmm 1100 Volts with aluminium multi stranded conductor two core suitable for service connection all as specified and directed by Engr-in-Charge. |
| 116 | Supply, laying, connecting and testing twin flat PVC insulated cable 4 sqmm 1100 Volts with aluminium multi stranded conductor two core suitable for service connection all as specified and directed by Engr-in-Charge. |
| 117 | Supply, installation, testing and commissioning factory fabricated and tested LT Panel board Indoor type,made out of CRCA sheet not less than 2mm thick,CPRI approved, platform mounted of of suitable size, 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic copper bus bars of capacity 250 Amps rating installed on DMC insulators with bus bar chamber, dust and vermin proof, IP-42, front opening type with aprons for cable entry, with proper ferrule & cable gland, prewired with PVC insulated multistranded copper conductor FRLS cable of suitable size but not less than 1.5 sqmm complete 1100 volts grade mounted at suitable working height with adequate workable ground clearnce on MS frame not less than 50x50x3mm having anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade and comprising of the following:- BUS BAR CHAMBER:- (a) 250 Amp three phase and neutral copper conductor, with color coding with heat shrinkable sleave and shall be mounted on non-hygroscopic, non-combustible, high strength DMC material, inter connection of all incomings & outgoings.INSTRUMENT CHAMBER:- (i) Volt Meter 96mmx96mm,flush type rated 0-500V, Digital type with selector switch- 01 Set. (ii) Amp Meter,96mmx96mm,flush type rated 0-200 Amps digital type with suitable size CT's (for three phase)- 01 Set . (iii) RYB Phase indicating lamp LED type with MCB 20A SP 'C' Series- 1 Set of three. INCOMING:- (i) MCCB 125 Amps 25 KA , 4 Pole with adjustable thermal magnetic release-01 Nos. OUTGOING:- (i) MCCB 4 Pole 63 Amps, 415 volts, 50Hz, 16 KA-03 Nos. (ii) MCB 2 Pole 10 Amps, 415 volts, 50Hz, 10 KA-01 Nos. (iIi) Automatic star delta starter for 10 HP to 15 HP Motor three phase 415 Volt -02 Nos (iv) Automatic star delta starter for 10 HP to 15 HP Motor three phase 415 Volt 15 HP to 25 HP-01 Nos Make : Havells/L &T or Equivelent. (v) Panel wiring for control circuit with copper cable 1.5 sqmm & power wiring minimum 4 Sqmm PVC insulated 1100 volts grade. (vi) PCC of suitable ratio for foundation etc. |
| 118 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25x4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991). (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 7.5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 119 | M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip. |
| 120 | Schedule of Credit Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail