| 1 | M&L for opening the electric induction motor of capacity 10-25 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including all other insulating material complete all as specified and as directed.Note : \\"Copper winding wire of appropriate gauge will be measured under item No. 16 here-in-after as supply only\\" |
| 2 | M&L for opening the electric induction motor of capacity 30-40HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including all other insulating material complete all as specified and as directed. Note : \\"Copper winding wire of appropriate gauge will be measured under item No. 16 here-in-after as supply only\\" |
| 3 | M&L for opening the electric induction motor of capacity 50-75 HP and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including complete all as specified and as directed. Note : \\"Copper winding wire of appropriate gauge will be measured under item No. 16 here-in-after as supply only\\" |
| 4 | Disconnecting of electrical connections from panel board and taking out electic motor of capacity 10-25 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed. Note :- Spare Part will be measured & paid spaerately |
| 5 | Disconnecting of electrical connections from panel board and taking out electic motor of capacity 30-40 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed. Note :- Spare Part will be measured & paid spaerately |
| 6 | Disconnecting of electrical connections from panel board and taking out electic motor of capacity 50-75 HP from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed. Note :- Spare Part will be measured & paid spaerately |
| 7 | Supply only terminal box for 10-25 HP Motor. |
| 8 | Supply only terminal box for 30-40 HP Motor. |
| 9 | Supply only terminal box for 50-75 HP Motor. |
| 10 | Supply only terminal connection plate for 10-25 HP. |
| 11 | Supply only terminal connection plate for 30-40 HP. |
| 12 | Supply only terminal connection plate for 50-75 HP. |
| 13 | Supply and Fixing in renewal of CI bearing plate for electric motor 10-25 HP. |
| 14 | Supply and Fixing in renewal of CI bearing plate for electric motor 30-40 HP. |
| 15 | Supply and Fixing in renewal of CI bearing plate for electric motor 50-75 HP. |
| 16 | Supply only super enamelled copper winding wire of suitable gauge complete all as specified and as directed. |
| 17 | Disconnecting and De-coupling the centrifugal pump of capacity 10-25 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position including MS nuts, bolts and packing flange complete all as specified and as directed. |
| 18 | Disconnecting and De-coupling the centrifugal pump of capacity 30-40 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position including MS nuts, bolts and packing flange complete all as specified and as directed. |
| 19 | Disconnecting and De-coupling the centrifugal pump of capacity 50-75 HP from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position including MS nuts, bolts and packing flange complete all as specified and as directed. |
| 20 | Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position of 10 to 25 HP.Note :- Spare Part will be measured & paid spaerately |
| 21 | Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position of 30 to 40 HP. Note :- Spare Part will be measured & paid spaerately |
| 22 | Opening the centrifugal pump and repairing the same by renewal the unserviceable spare parts including machining work and re-assembling the same in original position of 50 to 75 HP. Note :- Spare Part will be measured & paid spaerately |
| 23 | Supply only following spare parts for centrifugal pump of capacity 10-25 HP. |
| 24 | CI Impaller |
| 25 | CI Casing wear ring DE/NDE |
| 26 | CI Gland plate |
| 27 | Key for impeller |
| 28 | Impeller nut |
| 29 | Remetalling of pump shaft turning and balancing |
| 30 | CI Stuffing box bush |
| 31 | Pump shaft SS (AISI-410) |
| 32 | Gland packing champion |
| 33 | CI Bearing cartiage DE/NDE |
| 34 | CI Tyre coupling type TC/P/011 make unique |
| 35 | SS Eye bolt with nut |
| 36 | CI Shaft sleeve |
| 37 | Set Gasket packing. |
| 38 | MS Stud with nut |
| 39 | Supply only following spare parts for centrifugal pump of capacity 30-40 HP |
| 40 | CI Impaller |
| 41 | CI Casing wear ring DE/NDE |
| 42 | CI Gland plate |
| 43 | Key for impeller |
| 44 | Impeller nut |
| 45 | Remetalling of pump shaft turning and balancing |
| 46 | CI Stuffing box bush |
| 47 | Pump shaft SS (AISI-410) |
| 48 | Gland packing champion |
| 49 | CI Bearing cartiage DE/NDE |
| 50 | CI Tyre coupling type TC/Q/014 make unique |
| 51 | SS Eye bolt with nut |
| 52 | CI Shaft sleeve |
| 53 | Set Gasket packing. |
| 54 | MS Stud with nut |
| 55 | Supply only following spare parts for centrifugal pump of capacity 50-75 HP |
| 56 | CI Impaller |
| 57 | CI Casing wear ring DE/NDE |
| 58 | CI Gland plate |
| 59 | Key for impeller |
| 60 | Impeller nut |
| 61 | Remetalling of pump shaft turning and balancing |
| 62 | CI Stuffing box bush |
| 63 | Pump shaft SS (AISI-410) |
| 64 | Gland packing champion |
| 65 | CI Bearing cartiage DE/NDE |
| 66 | CI Tyre coupling type TC/Q/014 make unique |
| 67 | SS Eye bolt with nut |
| 68 | CI Shaft sleeve |
| 69 | Set Gasket packing. |
| 70 | MS Stud with nut |
| 71 | MS coupling key |
| 72 | M&L for painting two coat of synthetic enamel paint on centrifugal pump & motor of any capacity rating 10-75 HP, scratching the rusted and suction/delivery pipe line including NRV and sluice valve, MS Base chanel complete all as specified and as directed. |
| 73 | S/F in renewal of MS base channel of existing size including cutting welding making hole and painting (two coat of synthetic enamel paint over a coat of red oxide) complete all as specified and as directed. |
| 74 | S/F in renewal of MS foundation bolts with nuts and washers size 20 mm dia and 450 mm long |
| 75 | Supply and Fixing Ball bearing 6305 |
| 76 | Supply and Fixing Ball bearing 6306 |
| 77 | Supply and Fixing Ball bearing 6307 |
| 78 | Supply and Fixing Ball bearing 6308 |
| 79 | Supply and Fixing Ball bearing 6309 |
| 80 | Supply and Fixing Ball bearing 6310 |
| 81 | Supply and Fixing Ball bearing 6311 |
| 82 | Supply and Fixing Ball bearing 6312 |
| 83 | Supply and Fixing Ball bearing 6313 |
| 84 | Supply and Fixing Ball bearing 6314 |
| 85 | Supply and Fixing of double ball bearing 3307 |
| 86 | Supply and Fixing of double ball bearing 3309 |
| 87 | Supply and Fixing of double ball bearing 21309 |
| 88 | Supply and fixing of Rollar bearing No-313 |
| 89 | Supply and fixing of Rollar bearing No-314 |
| 90 | Supply and fixing in renewal of CI foot valve flanged 100 mm bore complete all as specified and as directed |
| 91 | Supply and fixing in renewal of CI foot valve flanged 150 mm bore complete all as specified and as directed |
| 92 | Supply and fixing in renewal of CI foot valve flanged 80 mm bore complete all as specified and as directed |
| 93 | Supply and fixing of CI Non return valve of follolwing sizes complete all as specified and as directed |
| 94 | 200 mm bore dia pipe. |
| 95 | 150 mm bore dia pipe. |
| 96 | 100 mm bore dia pipe. |
| 97 | 80 mm bore dia pipe. |
| 98 | Supplying & Fixing , jointing and testing of cast iron sluice valve ISI marked (PN-1.6) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and as directed. |
| 99 | 200 mm bore dia |
| 100 | 150 mm bore dia. |
| 101 | 100 mm bore dia.. |
| 102 | 80 mm bore dia.. |
| 103 | Supply, fixing, jointing and testing of cast iron butterfly valve of following size ISI marked class (PN 1.6) Disc DI, confirming to IS 13095, having stainless steel stem including taking out unserviceable butterfly valve complete all as specified and as directed . |
| 104 | 80mm dia |
| 105 | 100mm dia |
| 106 | 150 mm dia |
| 107 | Supply and fixing in renewal of over load relay, type ML-2 relay range 9-14 Amps complete all as specified and as directed. |
| 108 | M&L for PVC insulated multistranded copper conductor wire 1100 volts in renewal single core of size 10.00 Sq mm complete all as specified and as directed. |
| 109 | M&L for PVC insulated multistranded copper conductor wire 1100 volts in renewal single core of size 16.00 Sq mm complete all as specified and as directed. |
| 110 | S & F in renewal of biometallic thermal over load relay 415 V 50 Hz of range 9-14 amp complete all as specified and as directed. |
| 111 | S & F in renewal of biometallic thermal over load relay 415 V 50 Hz of range 13-21 amp complete all as specified and as directed. |
| 112 | S & F in renewal of biometallic thermal over load relay 415 V 50 Hz of range 20-32 amp complete all as specified and as directed. |
| 113 | S & F in renewal of biometallic thermal over load relay 415 V 50 Hz of range 28-42 amp complete all as specified and as directed. |
| 114 | S & F in renewal of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Digital Type complete all as specified and as directed. |
| 115 | S & F in renewal of Volt Meter 0 to 500 Volts of size 96 x 96 mm Digital Type complete all as specified and as directed. |
| 116 | S&F in renewal Timer analog type |
| 117 | Disconnecting Electric connections from LT Control pannel and starter of non clogging submerssible Sewage pump set of any size 10 HP to 25 HP capacity and removing the pipe line connections from discharge side and taking out submersible pump set along with, column pipe from sewage sump with the help of chain pully block including transportation to workshop and back for repair and lowering of same pump in sewage sump after repair including renewal of rusted nuts bolts, rubber gasket complete all as specified and as directed |
| 118 | Labour for opening the non-clogging submerssible Sewage pump set, repairing, rewinding and assembling the pump set including insulating material of any size 10HP to 25 HP capacity complete all as specified and as directed. Note:- Copper winding wire and other spare parts required for repairing will be measured and paid under relevant item as supply |
| 119 | Supply and in renewal following spare parts for non-clogging sewage submersible pump set vertical type (KRTU type) of capacity upto 25 HP |
| 120 | SS rotor sleeve |
| 121 | SS rotor shaft ASS 410 |
| 122 | Joint of submersible cable |
| 123 | Submersible cable flat/round 3 Core 10 Sqmm |
| 124 | Ball bearing 6312ZZ |
| 125 | Roller Bearing 3310 |
| 126 | Roller Bearing NU 305 |
| 127 | Bearing 6306 2RS1/C3 |
| 128 | Bearing 6308 2RS1/C3 |
| 129 | Bearing 6309 2 R S1/C3 |
| 130 | Bearing 3212 |
| 131 | Mechanical seal up to 25 HP |
| 132 | M&L earthing complete with galvanised steel earth plate electrode 60x60cmx 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below nominal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 25x4 mm as earthing lead by mean of bolts, nuts, check nuts and washer of galvanised iron or steel all as shown in Electrical plate No-3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed. (Note:- GI strip 25x4 mm upto 7.5Rm shall be included in quoted unit rate and if extra required the same shall be measured and paid seperately under respective items.) NOTE :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 9.1 of Particular Specification. The decision of accepting officer in this regard shall be final concluding and binding on the contractor. |
| 133 | Supply and fixing LED street light fitting 70Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. |
| 134 | M&L for renewal unserviceable gland packing champion of pump set of any capacity upto 75 HP at site complete all as specified and as directed. |
| 135 | S&F in renewal of pressure gauge (0-10 Kg/Sqcm) with connecting accessories of suitable size for pumps |
| 136 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr deep for pipe line/cable in any type of soil getting out and levelling of bottom surface to required level complete all as specified and as directed. |
| 137 | Excavation in trenches exc 1.5 mtr wide and not exc 3.00 mtr deep for pipe line/cable in any type of soil getting out and levelling of bottom surface to required level complete all as specified and as directed. |
| 138 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed. |
| 139 | Removing excavated material from site to a distance not exc 50mtr away and depositing where directed at a level not exc 1.5mtr from the starting point complete all as specified and as directed. |
| 140 | Surface dressing n.exc 30 cm deep, averaging 15 cm deep for cleaning the area by cutting the unwanted bushes/vegitation growth in and arround the area of installations/around the valve pit chamber/along the pipe line routes if reqd etc and getting out in soft/loose soil, complete all as specified and as directed. |
| 141 | Disconnecting electric connections from LT Control pannel and starter of submerssible pump set of any size 5HP to 20 HP and removing the pipe line connections from discharge side and taking out submerssible pump set along with, column pipe from bore well with the help of chain pully block including transportation to workshop for repair and lowering of same pump in bore well after repair including renewal of rusted nuts bolts, rubber gasket complete all as specifeid and as directed. |
| 142 | M&L for development of tube well with compressed air and after with 25 % extra capacity pump by pumping muddy water. Note :-Development with compressed air by means of air compressor 210-310 CFM with pressure line at 4 to 6 Kg/Sqcm using suitable capacity pump until sand free water is obtained. The compressor/pumping set/ equipment for testing as required shall be arranged by the contractor. Vertical test of tube well housing up to reducer position plumb and alignment immediately after lowering the house in pipe and before commencement for gravel packing by tripped and plumb complete. Chemical & bacteriological testing of water sample from approved laboratory to ensure portability of water. No extra payment will be done on this account. |
| 143 | M&L for development of tube well with compressed air and after with 25 % extra capacity pump by pumping muddy water. Note :-Development with compressed air by means of air compressor 310-450 CFM with pressure line at 8 to 10 Kg/Sqcm using suitable capacity pump until sand free water is obtained. The compressor/pumping set/ equipment for testing as required shall be arranged by the contractor. Vertical test of tube well housing up to reducer position plumb and alignment immediately after lowering the house in pipe and before commencement for gravel packing by tripped and plumb complete. Chemical & bacteriological testing of water sample from approved laboratory to ensure portability of water. No extra payment will be done on this account. |
| 144 | Supply and fixing for water proof submersible cable 3 core copper conductor, PVC insulated 1100 volts grade 4 Sqmm protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable submersible cable complete all as specified and as directed. |
| 145 | All as per item No.77 here-in-before but of size 6 Sqmm |
| 146 | Supplying and lowering of GI column pipe 80mm dia, heavy duty including all fitting and welding both ends complete all as specified and as directed. |
| 147 | Supplying and lowering of GI column pipe 100mm dia, heavy duty including all fitting and welding both ends complete all as specified and as directed. |
| 148 | S&F in renewal moulded case circuit breakers 4 pole 160 Amps having breaking capcity 36 KA at 415 volts complete all as specified and as directed. |
| 149 | S&F in renewal moulded case circuit breakers 3 pole 100 Amps having breaking capcity 16 KA at 415 volts complete all as specified and as directed. |
| 150 | S&F in renewal moulded case circuit breakers 3 pole 63 Amps having breaking capcity 16 KA at 415 volts complete all as specified and as directed. |
| 151 | S&F in renewal 3 pole power contactor ML-2, 32 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed. |
| 152 | S&F in renewal 3 pole power contactor ML-1.5, 25 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed. |
| 153 | S&F in renewal 3 pole power contactor MNX-32, 32 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed. |
| 154 | S&F in renewal of fully automatic star - delta straters in sheet enclosure type ML-1.5 FASD complete all as specified and as directed. |
| 155 | S&F in renewal of fully automatic star - delta straters in sheet enclosure type ML-2.0 FASD complete all as specified and as directed. |
| 156 | S&F for submersible pump controller MUG-6 (5 HP - 7.5 HP DOL) or 3 seat enclosure with over load, short circuit, under current, unbalance, phase reversal, phase loss,locked rotar, eath fault, stall ,CB failure with fault record with date and time, having feature of fail safe operation, and over load characterstic complete all as specified and as directed. |
| 157 | Supply and fixing in renewal of mild steel nuts, bolts & washers etc of any size complete all as specified and as directed. |
| 158 | Supply and fixing well cap suitable for 200/250/300 mm bore pipe consisting of two parts complete with welding and machinery work having provision of cut out for passing of column pipe and fabricated out of mild steel sheet 3.15 mm thick complete all as specified and as directed . |
| 159 | Supply and laying new XLPE UG armoured , heavy duty electric cable with aluminium conductor, 1100 volts grade, of cross siectional area of following sizes including taking down the unserviceable one and deposited to MES store yard complete all as specified and as directed:- |
| 160 | 4 core x 16 Sqmm |
| 161 | 4 core x 25 Sqmm |
| 162 | M&L for dry river sand for cable cushioning for under and above the cable including punning complete all as specified and as directed. |
| 163 | S&F for sub Class 'B' brick, laid across the cable above the sand cushioning for protection of cable complete all as specified and as directed. |
| 164 | M&L for Straight through joints (epoxy) for LT underground cable including joint kits and labour complete for making joints suitable for aluminium conductor cables of size upto 25 Sqmm 4 core. |
| 165 | Material and labour for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, flooring sub base complete all as specified and as directed. |
| 166 | Material and labour for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in coping, grouting, MS frame made out of angle iron, finished even and smooth without using extra cement as on brick work/flooring complete all as specified and as directed. |
| 167 | Material and labour for PCC (1:3:6) type C-1 (with 20 mm graded stone aggregate) as in channel drain , finished even and smooth without using extra cement as on brick work/flooring complete all as specified and as directed. |
| 168 | Drilling not less than 250 mm bore hole by DTH (Down the hole) method to any depth below the ground level in any kind of rock/soil upto 100 mtr deep including disposal of surplus soil to a distance not exc 50 mtr away complete all as specified and directed. Note : 1) In case of encountering rock prior to 30 mtr depth from ground level, the decision of the Garrison Engineer for reboring shall be final and binding. Specific order in writing shall be issued by Garrison Engineer for reboring and the quantities shall vary accordingly. 2) Cost of transportation of DTH plant is deemed to be included in the unit rate. |
| 169 | Supplying, lowering & fixing 200 mm nominal bore MS casing pipe, heavy duty as per IS-3589, minimum 6.0 mm thick ERW duly welded both sides socketed ends including Pea gravels complete all as specified and as directed. |
| 170 | Supplying, lowering & fixing into bore hole 200 mm nominal bore MS casing pipe, heavy duty as per IS -3589 minimum 6.00 mm thick ERW slotted tube having 1000 slots of size 1.58 x 75 mm per mtr length uniformly distributed on surface, duly welded both side socketed ends including pea gravels complete all as specified and as directed. |
| 171 | Supplying, lowering & fixing 150 mm nominal bore MS casing pipe, heavy duty as per IS-3589, minimum 6.0 mm thick ERW duly welded both sides socketed ends including Pea gravels complete all as specified and as directed. |
| 172 | Supplying, lowering & fixing into bore hole 150 mm nominal bore MS casing pipe, heavy duty as per IS -3589 minimum 6.00 mm thick ERW slotted tube having 1000 slots of size 1.58 x 75 mm per mtr length uniformly distributed on surface, duly welded both side socketed ends including pea gravels complete all as specified and as directed. |
| 173 | M&L for 200 mm internal dia UPVC casing pipe conforming to IS-4985-2000 with minimum pressure rating 8.0 Kg/Sqcm in 6.00 mtr length with male and female end with all necessary fittings including joiting and jointing materials complete all as specified and as directed. |
| 174 | M&L for 200 mm internal dia UPVC slotted pipe conforming to IS-4985-2000 with minimum pressure rating of 8.0 Kg/Sqcm having 3mm slots in 2.44 to 3.85 mtr length with male and female end with all necessary fittings including joiting and jointing materials complete all as specified and as directed. |
| 175 | M&L for 75 mm internal dia UPVC pipe conforming to IS-4985-2000 (SCH-80) having with male and female end with all necessary fittings including joiting and jointing materials complete all as specified and as directed. |
| 176 | M&L for 50 mm internal dia UPVC pipe conforming to IS-4985-2000 (SCH-80) having with male and female end with all necessary fittings including joiting and jointing materials complete all as specified and as directed. |
| 177 | Supply & fixing housing clamp for 50 mm bore pipe made out of flat MS 100x10 mm thick (length 60 cm) with 4 Nos 20 mm dia of suitable size of bolt, nuts, washers etc including drilling holes of suitable sizes and painting 2 coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and as directed. |
| 178 | Supply and fixing in renewal, installation, testing and commissioning of feeder pillar box ,outdoor type cubical shape,three phase, 4 wire, Al bus bar for phases and neutral made out of CRCA sheet 3.15 mm thick ,factory fabricated , CPRI approved , powder coated ,dust and vermin proof , provn for ventilation , angle iron frame and four legs of 50x50x6mm thick angle iron ,2 ft long grouted on PCC foundation of height not less than 30 cm from the ground level , grouting properly and of suitable size to accommodate the items mentioned below and having separate compartment /chambers for cable gallery busbar ,switch gear etc all as specified and comprising of following including necessary cable connections to the MCCBs, voltmeter, Ammeter and cable lugs etc . |
| 179 | (a) Al bus bar with PVC sleeve suitable for 200 amps for phase & 200 Amp for neutral - 01Set.(b) Voltmeter,digital type 0- 500 volt,with selector switch - 01 set (c) Ammeter Digital type 0-100Amps, with selector switch and CT'-1set(d) Phase indicating lamps LED type ( red , yellow, blue) 01 set(e) Incoming MCCB 63 Amp 3 pole 18 KA with adjustable thermal and fixed magnetic release -01 No(f) outgoing MCCB 40 Amp 3 pole 18 KA with adjustable thermal and fixed magnetic release -01 No(g) FASD Starter ML 1.5 FASD with MS sheet enclosure -01 Nos Make-L&T(h) Analog time switch -01 No (j) Single phase preventer-01 No(k) Phase sequence corrector for complete three phase system - 01 Set |
| 180 | Supply and filling coarse sand in bottom of recharge chamber 1.5 to 2mm size as per existing complete all as specified and as directed. |
| 181 | Taking out old/existing coarse aggregate of any size, washing it high pressure water pressure at site and relaying to its original position for easy perculation of rain water pit into ground complete all as specified and as directed. |
| 182 | Supply and filling/topping up coarse aggregate 63mm as screening material in rain water pit complete all as specified and direcetd. |
| 183 | Demolition of brickwork or stone/Boulder masonry built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles etc complete all as specified and as directed. |
| 184 | M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and as directed. |
| 185 | All as per srl item No.114 here-in-before but except bricks.Note:- Bricks obtaiend from demolition from item No 113 here-in-before to be used. |
| 186 | M&L for 10mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:4) complete all as specified and as directed. |
| 187 | M&L for 15mm thick cement plaster on other than fair faces of brick work or concrete surfaces in cement mortar (1:4) complete all as specified and as directed. |
| 188 | De-silting of existing drain of size exc 0.30x0.30 mtr but n.exc.0.75x0.75 mtr and removal of clag/mud, vegetation, garbage, dry leafs etc and removing the same from site to a distance exc. 250mtr but n.exc.500 mtr and depositing as and where directed. |
| 189 | Labour for cutting thick bushes, shrubs and tree of girth not exc. 30 cm and removing/depositing the same as and where directed. |
| 190 | Removing old/broken PCC/RCC covers of any size and M&L for SFRC perforated cover heavy duty 100mm thick set in CM 1:4 complete all as specified and as directed. Note: Covers shall be measured in complete and no deduction shall be made for perforation. |
| 191 | M&L for pre cast RCC 1:2:4 type B-1 as in cover slab inclusive of form work and set in cement mortar (1:4) complete all as specified and as directed. |
| 192 | Dismantlling old/broken PCC/RCC covers of any size and any type complete all as specified and as diirected. |
| 193 | M&L Framed work such as in grills, grating, angle Iron, MS strip, MS Sheet upto 3 mm, etc with ends of bars, shoulder or revetted or forged into spike frame,guard bars barred iron door,railing frame or similar work and locking arrangement including cutting, drilling , welding and painting with coat of synthetic enameled paint over a coat of redoxide primer after preparation of surface complete all as specified and directed. |
| 194 | M&L Preparation of new/old plastered surfaces of walls & applying two coats of apex weather coat paint over a coat of white primer complete all as specified and as directed. |
| 195 | M&L for sign board made out of 2mm thick in Radium Paint sheet steel of size 120x90 Cms painted both side with over a coat of red oxide primer and writing both side \\"Rain water harvesting pit No/Bore well No, GE (U) water supply\\" with white paint over approved painted back ground and embedded in PCC 1:3:6 type C2 of 30cmx30cm x 30 cm at 2 mtr height above ground level complete with angle Iron of size 50x50x5 mm including taking down old unserviceable sign board complete all as specified and as directed. |
| 196 | Supply and filling/topping up broken boulders 5mm to 25mm as screening material complete all as specified and as directed. |
| 197 | Supply and filling/topping up coarse aggregate 40 mm as screening material complete all as specified and direcetd. |
| 198 | Supply and filling/topping up coarse aggregate 20 mm as screening material complete all as specified and direcetd. (xi) All existing earthing of the lifts shall be maintained and made fully functional by the contractor to the entire satisfaction of the Engr-in-Charge. Please Enable Macros to View BoQ information |