| 1 | S&F providing WPC Jalli 24mm thick including fixing materials including Frame work (Iron /Steel) and dismantling of existing PCC Jalli, pcc debries thorwn away from site complete all as specified and directed. Note:- Frame work shall be measured and paid separately. |
| 2 | S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar Road crossing drain covers work conforming to Fe.290.Gde-E-165 complete all as directed |
| 3 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid and bedded in any morter. |
| 4 | M&L for granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) 20mm thick with admixture of pigment to match with shade of granite incl 12mm thick rendering in CM 1:3 as backing coat for receiving of granite complete all as specified and directed. |
| 5 | Dismantling of fencing wire mesh, any type, complete all as specified and directed. |
| 6 | Supply Mild Steel Galvanised Chain link fencing including wires, mesh of size 50x50mm, weight not less than 3.0 Kg/Sqm confirming to IS, type standards rails, straining bolts etc including provision of binding wire, complete all as specified and directed. |
| 7 | Fixing onlyMild Steel Galvanised chain link fencing including line wire, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified and directed. |
| 8 | Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 9 | S&F MS screw bolts (machine made) with hexagonal or square heads at one ends and screwed the other, or screwed both ends, each screwed end to be fitting with washer and one hexagonal or square nut n.exc. 5cm long and dia of shank 8 to 10 mm etc. |
| 10 | M&L for TMT Bars 10mm dia and over cut to length , bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire aneeanlead not less than 0.90mm dia or securing with clips etc complete all as specified and directed |
| 11 | M&L for RCC 1:2:4 Type B1 (Usong 20mm graded stone aggregate as in slabs/covers/beams including necessary formwork and demolition of old exisintg Rein forced cement concrete etc complete all as specified and directed |
| 12 | Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground , complete all as specified and directed. |
| 13 | Dismentling wrought iron or mild steel work of any description not other wise provided. |
| 14 | S & F in Repairs Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc.as directed (each line wire to be measured). |
| 15 | Restraining & resecuring existing barbed wire of any type incl making good staples etc any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc (each line wire to be measured) complete all as specified. |
| 16 | Mild steel angle iron posts and struts, MS flat iron fillet securing chain link fencing confirming to FE-290 E-165 as in fencing including cutting tops for required shape, drilling holes,bolting, notching for wire including all necessary drilling of similar work, complete all as specified and directed. |
| 17 | M&L, preparation of new steel surface, priming with red oxide / zinc chromate and two coats of synthetic enamel (ordinary tint) painting to steel and iron surface of any description over 10cm in width or girth not otherwise described. |
| 18 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/Plain steel sheet 0.50mm thick as in screen on top of wall crimpted/tapard at the external end slope of any colour having tensile strength 550 Mpa as in roof covering fixed with self tapping screws and caps etc complete all as specified and directed. |
| 19 | M&L for Plain cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in foundation, filling and mass concrete, complete all as specified and directed. |
| 20 | Demolition of stone, brick masonry built in cement mortar incl quoins, arches, etc but exceeding ashlar facing dressed stone Work etc. |
| 21 | Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM(1:4) incl Dismantling of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified. |
| 22 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. |
| 23 | M&L rendering 15 mm thick on fair faces of brick surfaces or concrete surfaces and finished surfaces even & smooth without using extra cement in CM 1:4 fair finishing to top surface as directed by Engineer-in-Charge |
| 24 | Preparation of new plastered/unplastered surfaces of walls and applying three coats of white/Colour wash, complete all as specified and directed. |
| 25 | Preparing old decorated/plastered or un-plastered surfaces of walls by scrapping the surfaces and steel wire brushing down smoke soot,mould,mass and efflorescence salts and trading oil and greasy spots etc and applying one coat of Acrylic exterior emulsin paint complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for complete removal existing surfaces of Old plasterd and applying two coats of White/Colour wash complete all as specified and as direcred. |
| 27 | Demolition of plain un reinforeced cement concrete for any thickness in any position and of any discription complete all as specified and as diredted |
| 28 | M&L FOR Providing, cement concrete Type B1,1:2:4 (using 20 mm graded aggregate) as in copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 29 | M&L 100mm htick PCC 1:2:4 type B-2 using 40 mm thick stone aggregate as in hard standing. etc incl finished even & fair complete all as specified. |
| 30 | M&L 40mm htick PCC 1:2:4 type B-1 using 20 mm thick stone aggregate as in path/hard standing incl finished even & fair complete all as specified. |
| 31 | M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm thick stone aggregate as in subbase of floor for chequred tiles/Paver Block complete all as specified. |
| 32 | M&L coloured chequerred cement concrete tiles 30 cm x 30 cm x 25 mm thick machine pressed set jointed and pointed with grey cement & pigments in neat cement slurry in floors set in 15mm thick CM(1:6) including filling joints withwhite or colour cement as directed. |
| 33 | M&L for Machine pressed precast concrete interlocking paver block of colour Red/Yellow glossy type any shape and size, as approved by Engr-in-Charge confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade |
| 34 | M&L for Machine pressed precast concrete interlocking paver block of colour Red/Yellow glossy type any shape and size, as approved by Engr-in-Charge confirming to IS 15658-2006 of 80 mm thickness, M-35 Grade |
| 35 | M&L for dismantling and laying of old existing Machine pressed precast concrete interlocking paver block any size of colour Red/Yellow glossy type any shape and size, as approved by Engr-in-Charge confirming to IS 15658-2006 of 60 mm/80mm thickness, M-35 GradeNote : Sand Cushion measured separatley |
| 36 | M&L sand filing under floors or in foundations including watering and consoldation. |
| 37 | S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding and screwing & Painting on top surfaces compleate all as specified and directed |
| 38 | S&F rolled mild steel as in doors or gate of angle of other section with gusset plates,rails, braces, etc coplete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and incl either hooks and hinges or steel hanging door fitting(exlusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. |
| 39 | S&F PVC(SWR) pipes, 75 mm external dia double socketed in any length with rubber joints, fixed to walls etc with MS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of 100/75 mm dia and in any position complete all as specified. |
| 40 | S&F PVC (SWR) bends suitable for 75 mm external dia with or without access door complete all as specified |
| 41 | S&F PVC (SWR) pipes, 110 mm external dia, type-B, ISI marked (IS:13592) double socketed in any length with rubber ring joints, fixed to walls etc with ms clampsMS clamps including dismantling of cast iron, AC / PVC pipes including all fittings and accessories of 100/75 mm dia and in any position complete all as specified. |
| 42 | S&F PVC (SWR) bends suitable for 110 mm external dia with or without access door complete all as specified |
| 43 | M&L for Reinforced concrete 300mm dia pipes, class NP2, laid and jointed complete with collars including necessary pacing in plain cement concrete 1:3:6 complete all as specified and directed. |
| 44 | M&L for Reinforced concrete 450mm dia pipes, class NP2, laid and jointed complete with collars including necessary pacing in plain cement concrete 1:3:6 complete all as specified and directed. |
| 45 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains, side guide wall including all necessary form work complete all as specified and directed. |
| 46 | S&F SFRC drain covers and frame medium duty of overal size 600mmX450mmX80mm thick, factory made and test load 10 tonnes (MD-10), strength as per IS: 1726-1991 (Make-Polycrete) all as specified by Engineer-in-Charge. |
| 47 | M&L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making dainage opening wherever required complete all as specified and directed. |
| 48 | M&L for using mechinical means or manual method to clean the existing drain of any size or depth to clean such that free from any soil, dirt or building material including demolition of any existing foreign material , complete all as directed by Engr-in-charge. Please Enable Macros to View BoQ information |