| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Repair/Replacement of pumping system, pipe line control valves pumping system and switch gear installed at JIB area under GE Utilities Udhampur Contract No: GE/U-05/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Material and labour for decoupling and disconnecting suction and discharge pipelines, dismantling and taking down the pump set from foundation, dismounting from base channels, stripping and opening of all pump components, derusting, cleaning, and complete overhauling, including repair or replacement of unserviceable parts of the pump set, and transportation to workshop for repairs wherever required. Reassembling of the pump set, mounting and fixing on base channels, recoupling of suction and discharge lines, alignment, commissioning and testing, complete, in respect of centrifugal / multistage pump of capacity 75 HP, all as specified and as directed by the Engineer-in-Charge. |
| 3 | Note: The quoted rate shall be deemed to include the following:(i) Provision of hydra crane, if required, complete with operator, helper(s) and requisite number of mates for decoupling, disconnecting, loading, unloading, positioning, fixing on base channels, recoupling of suction and discharge lines and alignment of pump set.(ii) Vehicle for transportation of pump set to and from workshop, wherever required.(iii) Manpower comprising Skilled Pump Mechanic for dismantling, overhauling, reassembly and alignment works.(iv) Tools & Plants including slings, lifting tackles, holding/catching devices, clamps, load supports and all other accessories required for safe handling of the pump set.(v) Skilled Electrician for disconnection and reconnection of electrical connections of pump motor and associated control panel, including testing after reinstallation.(vi) Supply and fixing of replacement parts, shall be measured and paid for separately under the relevant items of Schedule ‘A’. |
| 4 | Description all as per ser item No 1.0 here-in-before but capacity 30/40/50 HP. |
| 5 | Supply and fixing of new spare parts for single stage / double stage / multistage centrifugal pump sets of capacity 75 HP, as per manufacturer’s standard composition and specifications of the existing make and model of pump, including replacement of worn-out, damaged or unserviceable components, complete, all as specified and as directed by the Engineer-in-Charge. |
| 6 | Impeller, MOC: CI |
| 7 | Shaft, MOC: CS |
| 8 | Shaft sleeves, MOC: BR |
| 9 | Casing bearing, MOC: CI |
| 10 | Bearing housing/Bearing cover, MOC: CI |
| 11 | Gland cup with nut and bolts, MOC: CI |
| 12 | Jaw/Spider/Star/Tyre Coupler, MOC: CI |
| 13 | Inter stage ring/Shaft sleeve nut, MOC: BR |
| 14 | O Ring, MOC: Neopren rubber |
| 15 | Packings/Mechanical seal |
| 16 | Supply and fixing of new spare parts for single stage / double stage / multistage centrifugal pump sets of capacity 30/40/50 HP, as per manufacturer’s standard composition and specifications of the existing make and model of pump, including replacement of worn-out, damaged or unserviceable components, complete, all as specified and as directed by the Engineer-in-Charge. |
| 17 | Impeller, MOC: CI |
| 18 | Shaft, MOC: CS |
| 19 | Shaft sleeves, MOC: BR |
| 20 | Casing bearing, MOC: CI |
| 21 | Bearing housing/Bearing cover, MOC: CI |
| 22 | Gland cup with nut and bolts, MOC: CI |
| 23 | Jaw/Spider/Star/Tyre Coupler, MOC: CI |
| 24 | Inter stage ring/Shaft sleeve nut, MOC: BR |
| 25 | O Ring, MOC: Neopren rubber |
| 26 | Packings/Mechanical seal |
| 27 | Lath/Mchining works of any type at workshop required for balancing of impller/for fixing of new parts to existing shafts required for proper setting and smooth functioning to achieve desired discharge of the pump for 75 HP pump complete all as specified and as directed by Engr-in-charge. |
| 28 | Description all as per srl item No. 5.00 here-in-before but capacity of 30 to 50 HP Pump |
| 29 | Material and labour for disconnecting electrical connections of 75 HP motor, dismantling and removing the unserviceable motor from its existing position by unscrewing foundation bolts and nuts, decoupling the motor from the pump, shifting and transporting the same to workshop for repairs, including dismantling of motor, cutting and removal of burnt stator/rotor windings, cleaning of slots, and transporting the motor back after repairs/winding. Re-assembling, refixing and aligning the motor at its original location, including coupling with pump, commissioning and testing, complete, all as specified and as directed by the Engineer-in-Charge.Note:(i) Rewinding of motor stator and/or rotor shall be measured and paid for separately under the relevant items of Schedule ‘A’.(ii) The quoted rate shall be deemed to include the cost of loading, unloading, transportation, Bearings, grease, nuts, bolts and washers of any size and shape, minor consumables, refixing of serviceable motor, electrical reconnection, alignment with pump, and making the motor fully functional, including testing at its existing location/position, complete, all as specified and as directed by the Engineer-in-Charge. |
| 30 | Description all as per srl item no. 7.00 here-in-before but capacity 30/40/50 HP motor |
| 31 | Removing burnt-out winding from rotor and stator, cleaning of slots thoroughly, repairing and refilling of damaged slots wherever required with approved insulating/slot repair material, providing and inserting high quality Class ‘B’ insulation paper inside the slots, rewinding of electric motor of capacity 75/60/50/40/30/25/20/15/12/10/5/3/2/1.5 HP with super enamelled copper winding wire of same size and gauge as per existing, wrapping with high quality cotton tape, varnishing with superior quality insulating varnish, including baking/drying at required temperature and for required duration, complete, all as specified and as directed by the Engineer-in-Charge.Note: The quoted rate shall be deemed to include the cost of all labour, slot repairing/refilling material, insulation, winding, varnishing, baking/drying and routine testing. |
| 32 | S&F Bearing No. 6307 C3, including dismantling of old/unserviceable, cleaning, re-alignment, lubrication, and testing, complete, all as specified and directed by the Engineer-in-Charge. |
| 33 | S&F Bearing No. 3307 ATN9, including dismantling of old/unserviceable, cleaning, re-alignment, lubrication, and testing, complete, all as specified and directed by the Engineer-in-Charge. |
| 34 | Supply, installation, testing and commissioning of OFF-load changeover switch, 800 Amps, 415 Volts, 4-pole, side-handle operated, complete with stainless steel enclosure of approved gauge including Including taking down and dismantling of existing old/unserviceable OFF-load changeover switch, disconnecting of incoming and outgoing power cables, supply and fixing of new changeover switch in replacement, refixing and reconnecting of incoming and outgoing cables with new suitable size cable lugs, nuts, bolts, washers and insulating sleeves, proper termination, alignment and tightening, earthing connections, and making good disturbed surfaces,complete, all as specified and directed by the Engineer-in-Charge. |
| 35 | Description all as per srl item No. 12.00 here-in-before but of capacity 320 Amps. |
| 36 | Supply, installation, testing and commissioning of on-load changeover switch, 400 Amps, 415 Volts, 4-pole, suitable for LT applications, complete with all necessary accessories. Including dismantling, disconnecting and removal of existing old/unserviceable on-load changeover switch, supply and fixing of new changeover switch in replacement in the existing LT panel, disconnecting and reconnecting incoming and outgoing power cables with proper termination using suitable size cable lugs, nuts, bolts, washers and insulating sleeves, providing earthing connections, alignment and tightening of terminals, and making good disturbed surfaces. |
| 37 | Descriptio all as per srl item No. 14.00 here-in-before but of capacity 320 Amps. |
| 38 | Descriptio all as per srl item No. 14.00 here-in-before but of capacity 200 Amps. |
| 39 | S&F in relpacement of load line MCCB 800 Amps 4 pole 415 volts with adjustable thermal and fixed magnetic setting of breaking capacity 35/36KA, Ics=100% Icu including taking down the old existing MCCB complete all as directed by Engr in charge. |
| 40 | Description all as per srl item No. 17.00 here-in-before but of capacity 630 Amps. |
| 41 | Description all as per srl item No. 17.00 here-in-before but of capacity 400 Amps. |
| 42 | Description all as per srl item No. 17.00 here-in-before but of capacity 320 Amps. |
| 43 | Description all as per srl item No. 17.00 here-in-before but of capacity 200 Amps. |
| 44 | Description all as per srl item No. 17.00 here-in-before but of capacity 160 Amps. |
| 45 | Description all as per srl item No. 17.00 here-in-before but of capacity 125 Amps. |
| 46 | Supply, installation, testing and commissioning of power contactor, 3-pole, AC-3 duty, suitable for 415 V, 50 Hz, with AC coil, current rating suitable for motor capacity up to 75 HP and FRAME size shall match the existing contactor, complete with auxiliary contacts (minimum 1 NO + 1 NC), arc chutes, terminal shrouds, mounting accessories, internal control wiring with ferrules, and electrical/mechanical interlocking arrangement (where applicable), including dismantling of old/unserviceable contactor and refixing of new contactor in existing star-delta starter / LT panel, complete, all as specified and directed by the Engineer-in-Charge. Make: Same as existing Siemens / L&T / Schneider / ABB / Havells, or equivalent of matching frame size and mounting to suit existing starter/panel, conforming to relevant IS / IEC standards. |
| 47 | Description all as per srl item No. 24.00 here-in-before but suitable for motor capacity up to 50 HP. |
| 48 | Supply, installation, testing, and commissioning of thermal overload relay (OLR) suitable for three-phase induction motors up to 75 HP, with adjustable current range matching the motor’s full-load current, including single-phasing protection, manual/auto reset facility, and trip indication. The OLR shall be fully compatible with AC-3 duty contactors. The work includes dismantling of old/unserviceable OLR and refixing of the new OLR on the existing contactor in star-delta starter / LT panel, complete with all required wiring, ferrules, setting of current, and functional testing under load. Make: Same as existing Siemens / L&T / Schneider / ABB / Havells, or equivalent, ensuring compatibility with existing starter/contactor, and conforming to relevant IS / IEC standards, as specified and directed by the Engineer-in-Charge. |
| 49 | Supply, installation, testing and commissioning of electronic star-delta timer, panel-mounting type, suitable for 415 V AC, 50 Hz system, with adjustable time delay range 0–30 seconds / 0–60 seconds, having minimum 2 NO + 2 NC potential-free contacts, LED status indication, suitable for use in star-delta starter for motors up to 75 HP, including dismantling of old timer (if any), mounting, wiring, integration with existing control circuit, setting of time delay, testing and commissioning, complete, all as specified and directed by the Engineer-in-Charge. Make: Same as existing Siemens / L&T / Schneider / ABB / Havells, or equivalent of matching mounting and compatibility to suit existing contactor/starter, conforming to relevant IS / IEC standards. |
| 50 | Supply, laying, and fixing in replacement of PVC insulated, heavy-duty, single-core flexible copper conductor industrial cable, 1100 V grade, nominal cross-sectional area 120 sq. mm, including taking down of existing unserviceable cable, complete in all respects as per directions of the Engineer-in-Charge.Note: Excavation, earthwork, sand cushioning, protection with DWC/GI pipes, cable lugs, etc., shall be measured and paid separately under the respective items of Sch ‘A’. |
| 51 | Description all as per srl item No. 28.00 here-in-before but of size 95 sqmm. |
| 52 | Description all as per srl item No. 28.00 here-in-before but of size 70 sqmm. |
| 53 | Description all as per srl item No. 28.00 here-in-before but of size 50 sqmm. |
| 54 | Description all as per srl item No. 28.00 here-in-before but of size 35 sqmm. |
| 55 | Supply and fixing of heavy-duty copper thimble (lug), tinned, compression type, suitable for 120 sq. mm single-core copper conductor cable, including taking down and removal of existing unserviceable copper thimble, complete in all respects, all as specified and directed by the Engineer-in-Charge. |
| 56 | Description all as per srl item No. 33.00 here-in-before but of size 95 sqmm. |
| 57 | Description all as per srl item No. 33.00 here-in-before but of size 70 sqmm. |
| 58 | Description all as per srl item No. 33.00 here-in-before but of size 50 sqmm. |
| 59 | Description all as per srl item No. 33.00 here-in-before but of size 35 sqmm. |
| 60 | M&L for aluminium thimble of 240 sqmm size for cables all as specified and directed by Engr-in-Charge |
| 61 | Description all as per srl item No. 38.00 here-in-before but of size 185 sqmm. |
| 62 | Description all as per srl item No. 38.00 here-in-before but of size 150 sqmm. |
| 63 | Description all as per srl item No. 38.00 here-in-before but of size 70 sqmm. |
| 64 | S&F in replacement analog type Ampere meter (96mm x96 mm) complete with suitable CTs 0-300 Amps as per existing,complete all as specified and directed by Engineer - in - Charge. |
| 65 | S&F in replacement of analog type volt meter (96mm x96 mm) 0-500 volts as per existing, complete all as specified and directed by Engineer - in - Charge. |
| 66 | S&F in replacement of indicating lamps RYB as per existing, complete all as specified and directed by Engineer - in - Charge. |
| 67 | S&F in replacement of Push button as per existing, complete all as specified and directed by Engineer - in - Charge. |
| 68 | S&F in replacement of selector switch as per existing, complete all as specified and directed by Engineer - in - Charge. |
| 69 | Phase Changeover switches |
| 70 | Ammeter Selector Switches |
| 71 | Voltmeter Selector Switches |
| 72 | Changeover Selector Actuators (Side/Lever Handle) suitable for the existing changeover switch. |
| 73 | Changeover selector actuator (operating handle) including operating rod, suitable for the existing changeover switch. |
| 74 | Supply and laying DWC (Double wall corruguated) pipe 40/32 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing complete all as specified and directed by Engr-in-charge. |
| 75 | Description all as per srl item No. 47.00 here-in-before but of size 50/38 mm. |
| 76 | Description all as per srl item No. 47.00 here-in-before but of size 63/50 mm. |
| 77 | Description all as per srl item No. 47.00 here-in-before but of size 77/63 mm. |
| 78 | Description all as per srl item No. 47.00 here-in-before but of size 90/75 mm. |
| 79 | Material and labour for painting of pump set (including motor and frame) 50 HP / 75 HP, including surface preparation by scraping and cleaning with emery paper to remove rust, scale, and loose paint, and applying one coat of red oxide primer followed by two coats of synthetic enamel paint of approved make and existing colour, complete, to the satisfaction of the Engineer-in-Charge. |
| 80 | S&F in replacement of Gland Packing Rope type 3 of size 8 mm made of asbestos grip with silicon complete all as specified and directed by Engr-in-Charge. |
| 81 | Description all as per srl item No. 53.00 here-in-before but of size 10 mm. |
| 82 | Description all as per srl item No. 53.00 here-in-before but of size 12 mm. |
| 83 | Supply and laying of synthetic rubber insulated electrical safety mats, minimum 2.5 mm thick, suitable for use up to 11 kV, conforming to IS 15652, for electrical shock protection, anti-skid type, of size 2.0 m × 1.0 m, complete in all respects, all as specified and directed by the Engineer-in-Charge. |
| 84 | Supply only, in replacement, of mild steel (MS) stud bolts of existing size, suitable for pumps and motors of various capacities installed at site, complete in all respects, all as specified and directed by the Engineer-in-Charge. |
| 85 | Supply only, in replacement, of grouting nuts and bolts of existing size, suitable for pumps and motors of various capacities including their foundations, and for sluice valves, non-return valves, foot valves, and air-release valve flanges installed at site, complete in all respects, all as specified and directed by the Engineer-in-Charge. |
| 86 | Supply only lithium base grease AP3 in 20 Kg pack suitable for application to ball bearing with operating temperature 30 to 120 degree celsius drop point 174 degree celsius, colour light fawn complete all as specified and directed by Enr-in-Charge |
| 87 | Supply only cotton waste coloured Grade \\"A' for cleaning rags in 25 Kgs bag complete all as specified and directed by Engr-in-Charge |
| 88 | Opening, maintenance and general servicing of Servo Voltage Stabilizers of various makes, having capacity 500 kVA, including opening of panels, removal of sludge and carbon deposits from dissipated coils / variac coils, buck-boost transformers and internal components; tightening of all nuts, bolts and electrical terminations; thorough cleaning of stabilizer coils and panels; checking, servicing and adjustment of servo mechanism, gear synchronizing system, carbon brush assembly, and mechanical linkages; inspection, testing and servicing of automatic voltage regulator (AVR) circuits, control wiring and other allied electrical and electronic components; replacement/refitting of defective parts as required; filling/replenishment of transformer oil; testing, calibration and trial run under load to ensure proper and smooth operation of the stabilizer, complete, all as specified and directed by the Engineer-in-Charge. |
| 89 | Note: Rates quoted by the contractor shall be inclusive of supply, replacement, fitting and testing of the following items, as required:(a) Servo motor with RC network, torque up to 30 kg-cm – 02 No.(b) Electronic control card for automatic voltage regulation – 01 No.(c) Transformer oil, suitable grade – 35 litres(d) Voltmeter, 0–500 volts capacity – 01 No.(e) Ammeter, CT-operated, suitable rating – 01 No.(f) Control / Circuit PCB, suitable for stabilizers of 30 kVA to 400 kVA – 01 No.(g) Pulse transformer, suitable for stabilizers of 30 kVA to 400 kVA – 01 No.(h) Rewinding of copper coils, including supply of copper conductor – up to 25 kg(j) Shifting of stabilizer from AOR of AGE Water Supply to workshop and back (To & Fro)(k) Miscellaneous consumables and small items such as carbon brushes, encoder/slotted/feedback ring or disc, push buttons (auto/manual), micro/limit press switches/selector switches, indicator lamps, fuses, lugs, sleeves, nut bolts, etc. |
| 90 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :-(a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1.(c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm.(d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal.(g) Testing of earthing.Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. |
| 91 | Supply and fixing black flexible rubber Tyre coupling as per sample TC 14,TC 15, TC 16, TC 17, etc complete all as specified and directed by Engineer-in-Charge. |
| 92 | Supply and fixing flexible rubber star coupling as per sample complete all as specified and directed by Engineer-in-Charge. |
| 93 | Excavator for any type of work as per site requirement like surface excavation, leveling of uneven surface, cleaning of vegetation, removing of solids to clean surface, etc complete all as specified and directed by Engineer-in-Charge. |
| 94 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. |
| 95 | Repairing and servicing of existing LT electrical panels/equipment such as LT Panel, Soft Starter, Feeder Pillar Box, MCC/PCC Panel, Pump Control Panel, and similar LT distribution and control equipment, including thorough dust cleaning of all internal and external components using approved methods, visual and physical inspection of power and control circuits, checking for loose connections, overheating marks, damaged insulation, malfunctioning components, and identification of electrical/mechanical faults including attending to and rectifying minor faults by tightening, realigning, cleaning of contacts, terminals, busbars, relays, contactors, control wiring, and associated accessories; testing of control and power circuits, functional checking of interlocks and protections; reassembly, refixing in position, trial run, commissioning, and satisfactory performance testing to restore the panel/soft starter to normal and safe operating condition, complete all as specified and as directed by the Engineer-in-Charge. |
| 96 | Notes:(i) The work shall be executed only through trained, skilled, and licensed electrician(s) having valid competency for LT electrical works.(ii) All tools, plants, testing instruments, ladders, scaffolding, safety appliances, PPE, and other T&P required for execution of the work shall be provided by the contractor at his own cost.(iii) Supply and fixing of any new parts, components, accessories, or replacement items, if required, shall be measured and paid for separately under the relevant item(s) of Schedule ‘A’.(iv) The contractor shall be responsible for taking all necessary safety precautions against electric shock and other electrical hazards during execution of the work, in accordance with the relevant safety provisions of the General Conditions of Contract and applicable statutory regulations. Any accident, mishap, or electric shock occurring during the execution of the work shall be the responsibility of the contractor, and the department shall not be held liable. |
| 97 | Supply only of Electrical Insulation Tape of approved make and quality, manufactured from high-grade PVC/self-adhesive insulating material, suitable for LT electrical applications, in different colours i.e. Red, Yellow and Blue (RYB) or any other colour as directed by the Engineer-in-Charge, having minimum thickness of 0.18 mm, width 19 mm, and length 20 metres per roll. The tape shall have good dielectric strength, adequate adhesive properties, resistance to moisture, heat, abrasion, and ageing, suitable for identification, insulation, and protection of electrical conductors and terminations, complete all as specified and as directed by the Engineer-in-Charge. |
| 98 | Supply and fixing in replacement of motor cooling fan, manufactured from stainless steel (SS) of approved grade and workmanship, suitable for induction motor of rating 75 HP, duly balanced and compatible with the existing motor shaft. The cooling fan shall be of size, design, and specifications matching the existing/sample and ensuring proper airflow and effective cooling of the motor, including removal of the unserviceable fan and refixing of the new fan, proper alignment, checking for smooth and vibration-free operation, and trial run of the motor, complete all as specified and as directed by the Engineer-in-Charge. |
| 99 | Description all as per ser item No 69.00 here-in-before but for motor ratting 30/40/50 HP |
| 100 | Supply and fixing in replacement of motor terminal box complete assembly, consisting of terminal enclosure box (outer housing) and internal terminal block, of approved make and workmanship, suitable for induction motors of rating 40/50/75 HP, matching the existing make, dimensions, mounting arrangement, and specifications, including taking down and removal of the existing complete terminal box assembly (enclosure box along with internal terminal block), supply and fixing of new complete terminal box assembly including terminal studs, insulation base, gasket, cover, fixing hardware, and making all electrical connections properly includes checking, tightening, insulation verification, and ensuring the motor is ready for safe and satisfactory operation, complete all as specified and as directed by the Engineer-in-Charge. |
| 101 | M & L for painting of existing LT panel board / LT feeder pillar box, indoor or outdoor type, of size up to 2.0 × 1.50 × 0.60 metres, including inner shell and outer shell as well as angle iron frame, with Siemens Grey shade or matching the existing colour, as directed by the Engineer-in-Charge.The work includes thorough surface preparation by scraping, rubbing down with sand paper, wire brushing/grinding to remove loose paint, rusted and corroded particles; cleaning the surfaces with dry cloths to make them free from dust, grease, and foreign matter; repairing and making good uneven surfaces to achieve a smooth finish. The prepared surfaces shall then be treated with one coat of red oxide zinc chromate primer, followed by two coats of approved synthetic enamel paint, applied uniformly to obtain an even, smooth, and durable finish, complete all as specified and as directed by the Engineer-in-Charge. |
| 102 | M & L for chemical spray using contact cleaner (DC 2.26 or equivalent), supplied in sealed container of 415 ml / 300 g, being a precision blended, multipurpose electrical contact cleaner, suitable for cleaning and maintenance of electrical and electronic components. The chemical shall be capable of penetrating and loosening stuck or rusted mechanisms, preventing corrosion, providing light lubrication, displacing and sealing out moisture, and improving electrical contact performance without leaving harmful residue. The item includes application at site as required for cleaning and protection of contacts, terminals, switches, relays, and similar components, complete all as specified and as directed by the Engineer-in-Charge. |
| 103 | M & L for repairing of outer housing of existing LT panel board / LT feeder pillar box, indoor or outdoor type, of size up to 3.00 × 1.50 × 0.60 metres, fabricated out of 2.0 mm / 3.15 mm thick CRCA sheet, including inner shell and outer shell, complete, including repairing and/or replacement of damaged or deformed portions of outer shell panels, panel doors, MCCB housing doors, changeover housing doors, straightening, refabrication where required, repairing of angle iron frame, tightening and/or replacement of nuts, bolts, screws, clamps, hinges, locking arrangements, and making the housing structurally sound, rigid, and properly aligned. Making good all repaired surfaces, ensuring proper closing and locking of doors, alignment of housings, and restoring the panel to serviceable condition, complete all as specified and as directed by the Engineer-in-Charge.Note: The cost of replacement of minor parts and accessories such as doors, angle iron sections, nuts, bolts, screws, clamps, hinges, and similar items required for execution of the work shall be deemed to be included in the quoted rate. |
| 104 | Supply, laying, fixing, jointing, testing, and commissioning of LT power cable, XLPE insulated, galvanized steel strip armoured, 3.5 core × 240 sqmm, 1100 Volt grade, heavy-duty, ISI marked, with aluminium conductor, overall sheathed with PVC, suitable for LT power distribution. The cable shall be laid in trenches, through protective pipes, under floors, or through walls, including necessary bends, supports, saddles/clamps, dressing, termination preparation, identification, and making electrical connections, complete all as specified and as directed by the Engineer-in-Charge. The item also includes taking down, dismantling, and removal of the existing unserviceable LT cable of similar capacity from site, complete.Notes:(i) Excavation, refilling, earthwork, sand cushioning, brick/cover protection, protective pipes/ducts, and related civil works shall be measured and paid for separately under the relevant items of Schedule ‘A’.(ii) Cable terminations, glands, lugs, and end connections shall be deemed to be included in quoted item rate. |
| 105 | Description all as per srl item No. 75.00 here-in-before but of size 185 sqmm 3.5 core. |
| 106 | Supply, installation, testing and commissioning in replacement of outdoor type Feeder Pillar Box, mounted on rigid angle iron frame, overall size not less than 1200 × 1500 × 450 mm, having independent compartments for busbar incoming and outgoing feeders, dust, vermin and weather proof with IP-65, conforming to IS/IEC 60529 and IS 2417 (as applicable), factory made, fabricated out of 3.15 mm thick CRCA MS sheet, suitable for 3 phase 415 V, 50 Hz AC supply. The chamber shall comprise aluminium busbars rated 1000 A for 3 phase and neutral, duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators – 01 set, with common earth busbar of GI strip 32 × 6 mm at the bottom and 2 earth terminals for the chamber. Complete with cable glands with independent plates at bottom for each outgoing and incoming feeder and powder coated in Siemens grey colour, fabricated with double door locking arrangement, all as approved. |
| 107 | Incoming: (i) ACB 4 Pole, 415 V, Manual Drawout typewith microprocessor release of capacity 800 Amps – 01 Nos.(ii) Digital modular metering panel comprising 3-phase Voltmeter, Ammeter & Phase Indicating lamps – 01 set.Outgoing:(i) MCCB 4 Pole, Current rating 630 A, electronic trip unit, adjustable overload & short circuit protection, breaking capacity 36 kA at 415 V, 50 Hz, including extended terminals – 02 Nos.(ii) MCCB 4 Pole, Current rating 400 A, electronic trip unit, adjustable overload & short circuit protection, breaking capacity 36 kA at 415 V, 50 Hz, including extended terminals – 02 Nos.Note:(i) Complete with earthing arrangement, danger notice plate, all interconnections, supports, shrouding, mounting, testing, commissioning, and accessories, as specified and directed by the Engineer-in-Charge.(ii) All switchgear mounted neatly inside compartments, with sufficient space for safe operation and cable terminations.Note: PCC work required for fixing / grouting of the panel on floor shall be deemed to be included in the quoted rate. |
| 108 | Supply, installation, commisioning and testing in replacement of LT Panel board outdoor type mounted on rigid angle iron frame, overall size not less than 1500 x 1200 x 450 mm having independent compartment for busbar incoming and outgoing feeders, dust and vermin proof, weather proof with IP-65, conforming to IS/IEC 60529 and IS 2417 (as applicable), factory made, fabricated out of 3.15 mm thick CRCA sheet suitable for 3 phase 415 V, 50 Hz AC supply busbar chamber with Aluminium busbar 600 Amp rating for 3 phase and neutral for wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators 01 set, common earth busbar of GI strip 32 x6 at bottom with panel board at 2 earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables and complete panel board painted with powder coating in siemens Grey colour and fabricated with double door system locking arrangement all as approved and comprising as under:- |
| 109 | Incoming : (i) MCCB 4 Pole, Current rating 400 Amps with electronic trip unit, adjustable overload & short circuit, breaking capacity 36 KA at 415 V, 50 Hz, including with extended terminals, frame size/ type compact- 01 Nos(ii) Changeover Switch 400 Amp 4 Pole - 01 Nos(iii) Meter module with Voltmeter, Ammeter, Selector Switch, CTs Control Fuse & Phase Indicating lamps.Outgoing : (i) MCCB 4 Pole, Current rating 200 Amps with electronic trip unit, adjustable overload & short circuit, breaking capacity 36 KA at 415 V, 50 Hz, including with extended terminals, frame size/ type compact - 03 NosNote: PCC work required for fixing / grouting of the panel on floor shall be deemed to be included in the quoted rate. |
| 110 | Supply, installation, commisioning and testing in replacement of LT Panel board indoor type mounted on rigid angle iron frame, overall size not less than 1500 x 1200 x 450 mm having independent compartment for busbar incoming and outgoing feeders, dust and vermin proof, factory made, fabricated out of 2 mm thick CRCA sheet suitable for 3 phase 415 V, 50 Hz AC supply busbar chamber with Aluminium busbar 400 Amp rating for 3 phase and neutral for wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators 01 set, common earth busbar of GI strip 32 x6 at bottom with panel board at 2 earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables and complete panel board painted with powder coating in siemens Grey colour and fabricated with double door system locking arrangement all as approved and comprising as under:- |
| 111 | Incoming : (i) MCCB 4 Pole, Current rating 320 Amps with electronic trip unit, adjustable overload & short circuit, breaking capacity 36 KA at 415 V, 50 Hz, including with extended terminals, frame size/ type compact- 01 Nos(ii) Changeover Switch 320 Amp 4 Pole - 01 Nos(iii) Meter module with Voltmeter, Ammeter, Selector Switch, CTs Control Fuse & Phase Indicating lamps.Outgoing : (i) MCCB 4 Pole, Current rating 160 Amps with electronic trip unit, adjustable overload & short circuit, breaking capacity 36 KA at 415 V, 50 Hz, including with extended terminals, frame size/ type compact - 03 Nos(ii) MCCB 4 Pole, Current rating 100 Amps with electronic trip unit, adjustable overload & short circuit, breaking capacity 36 KA at 415 V, 50 Hz, including with extended terminals, frame size/ type compact - 01 NosNote: PCC work required for fixing / grouting of the panel on floor shall be deemed to be included in the quoted rate. |
| 112 | Supplying, installing, testing and commissioning in replacement of factory-made, outdoor-type busbar chamber (feeder pillar box), overall size not less than 600 x 1000 x 450 mm, fabricated out of 3.15 mm thick CRCA MS sheet, dust, vermin and weather-proof, having IP-65 degree of protection conforming to IS/IEC 60529 and IS 2417 (as applicable), suitable for 3-phase, 415 V, 50 Hz AC supply, complete with independent compartments for busbar, incoming and outgoing feeders. The chamber shall be provided with minimum three (03) incoming cable provisions and minimum four (04) outgoing cable provisions. The busbar chamber shall comprise aluminium busbars of 1000 ampere rating for three phases and neutral, duly insulated with heat-shrinkable sleeves as per approved colour code and supported on epoxy insulators (one set). A common earth busbar of GI strip size 32 × 6 mm shall be provided at the bottom with two (02) earth terminals for the chamber. The feeder pillar shall be complete with independent bottom gland plates for each incoming and outgoing feeder, suitable cable glands, double-door locking arrangement, powder coated in Siemens grey colour, complete in all respects, as specified and as approved.Note: PCC work required for fixing / grouting of the panel on floor shall be deemed to be included in the quoted rate. |
| 113 | Taking out / taking down (retrieval) of unserviceable XLPE armoured LT underground/ laid along wall / laid on floor cable of any size and capacity, complete in all respects, including disconnection, careful removal, handling, stacking at designated location, and making good disturbed surfaces, all as specified and as directed by the Engineer-in-Charge. |
| 114 | Supplying and fixing, in replacement, cable route marker comprising 10 cm × 10 cm × 5 mm thick GI plate with inscription thereon, bolted and/or welded to 35 mm × 35 mm × 6 mm angle iron post of 60 cm length, including removal of the existing old marker and fixing the new marker firmly in the ground, complete in all respects, as specified and as directed by the Engineer-in-Charge. |
| 115 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth,foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. and taking out/laying of pipe lines of soft/loose soil. Complete all as specified and directed by Engr-in-Charge. |
| 116 | Returning, filling in, including spreading, leveling, watering and well ramming in layers, each layer not exceeding 25cm thick after pipes have been laid and tested complete, all as specified and directed by Engineer-in-Charge |
| 117 | Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete, all as specified and directed by Engineer-in-Charge |
| 118 | Material and labour for cutting of existing hard standing/floors/walls/PCC/RCC for crossing of DWC/GI pipes for laying of LT cables of any size, including necessary excavation and earthwork, and making good and repairing the cut portion with RCC/PCC, with width of trench not exceeding 0.45 m and depth not exceeding 0.75 m, complete all as specified and as directed by the Engineer-in-Charge. |
| 119 | Supply and fix in replacement cast iron sluice valve suitable of size 250 mm (PN 1.6) as per IS : 14846 with iron wheel head both end flanged, non rising type and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,complete all as specified and directed by Engr-in-Charge. |
| 120 | Description all as per as per ser item No 87.00 here-in-before but of size 200 mm dia |
| 121 | Description all as per as per ser item No 87.00 here-in-before but of size 150 mm dia |
| 122 | Supply and fix in replacement of cast iron non return valve suitable for 150 mm bore pipe heavy duty both end flanged of pressure rating PN 1.6 as per IS:5312 and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,Complete all as specified and directed by Engr-in-Charge. |
| 123 | M&L for replacement of complete unserviceable/damaged outer casing of 50 HP split case centrifugal pump having discharge capacity 19 LPS and head 68 metres, Pump make Kirloskar, Model DSM 80/36 (2 stages), including dismantling of existing casing, removal from site, fitting and fixing of new casing with proper alignment, jointing, nuts, bolts, gaskets, and all necessary accessories, complete in all respects. MOC: CI 260 (012) / BR LTB2 (110) / 40C8 (053), complete all as specified and as directed by Engineer-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail