| 1 | Taking down cement plaster on brick or stone walls, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by the Engr-in-Charge.Note:- 1. The work shall be executed up to G+5th floor Height. |
| 2 | Material and labour for 5 mm thick plastering in CM With Nano fiiler 1: Cement 1: Sand 3 on concrete surfaces as in sides of column, lintel, beam, chajja, Ceiling facia, railing, RCC wardrobe etc including finish the surface even and fair without using extra cement complete all as specified and as directed.Note:- 1. The work shall be executed up to G+5th floor Height.2. Nano wall filler shall be measured and paid separately. |
| 3 | Material and labour for preparation of old/new plastered surfaces and applying Nanotechnology based Nano Putty is white cement based product with dispersible polymer and functional additives for application on interior rough plasters to give a smooth surface and will form base for paint finish for interiors of the building, applied in 02 coats of total thickness 1.5mm @ 1.2 kgs/sqm complete all as specified. |
| 4 | Material and Labour for 02 coats of Nanotechnology based Acrylic Regular Distemper, water based gives walls a smooth and matt finish and applied on prepared surface of wall & ceiling over a coat of approved nano primer @ 6.50 sqm/ltr using AUTO-ROLLER and AIR-LESS PAINT SPRAYER complete all as specified and dircted by Engr-in-Charge. |
| 5 | Material and labour for 15mm thick plaster in cement mortar with Nano wall filler 1: cement 1: sand 4 in two layers, i.e as per manufacturers instruction on brick or concrete surfaces of wall finished the surface fair and even complete all as specified.Note:- 1. The work shall be executed up to G+5th floor Height.2. Nano wall filler shall be measured and paid separately. |
| 6 | Material and labour for rendering 10mm thick in cement mortar with Nano wall filler 1: cement 1: sand 6 on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified.Note:- 1. The work shall be executed up to G+5th floor Height.2. Nano wall filler shall be measured and paid separately. |
| 7 | Supply only Nanotechnology based Elastomeric Hydrophobic Powder/admixture (EHP) powder for cement plaster and concrete. |
| 8 | Material and labour for exposing cracks more than 1mm wide with tile cutter and foming V groves nex 10mm wide and 10 mm deep in INSIDE RCC roof and filling Nanotechnology based Anti- corrosive with high strength Carbon fiber based Shorter chain epoxy Coating Perocess:a) Clean the Surface and open the crack and apply nano base Bond coatb) Mix with Nano wall filler with Bond coat and Fill the crackc) Apply Final Bond coat in the cracked surfaceNote:- 1. Rate shall include for making surface clean,dustfree, dry, and free of wax, grease, oil, loose or peeling particle, and other foreign materials.2. During application ambient temperature is preferred. Frost, fog, or damp conditions should be avoided. |
| 9 | M&L for preparation of new surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/itre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt esistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10. sqm over new surfaces complete all as specified and as directedNote:- 1. The work shall be executed up to G+5th floor Height |
| 10 | M&L for complete removal of existing treatment and preparation of old surfaces and applying two or more coats of 100% Premium acrylicemuision paint having VOC less than 50 gm/itre and UV resistance as per IS15489 2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 itre/ 10 sgm over including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces compiete all as specified and as directed.Note :- 1. The work shall be executed up to G+5th floor Height |
| 11 | M&L preparation of new plastered surfaces and applying two coats of cement base paint over a coat of cement primer on external surfaces of walls complete all as specified and directed. |
| 12 | Complete removal of existing treatment & levelling of wall/ceiling surface using MECHANICAL / ELECTRICAL OPERATED SANDING / SCRAPING MACHINE WITH INBUILT VACCUM SUCTION system to suck the existing treatment as retrieved by scrapping/sanding etc for obtaining smooth paintable surface applying two coats of cement base paint on walls over a coat of cement primer all as specified & directed. Note:- 1. The work shall be executed up to G+5th floor Height |
| 13 | Complete removal of existing treatment & levelling of wall/ceiling surface using MECHANICAL / ELECTRICAL OPERATED SANDING / SCRAPING MACHINE WITH INBUILT VACCUM SUCTION system to suck the existing treatment as retrieved by scrapping/sanding etc for obtaining smooth paintable surface and preparation of old surface 02 coats of Nanotechnology based cement based paint, water based gives walls a smooth and matt finish and applied on prepared surface of wall & ceiling over a coat of approved nano primer @ 6.50 sqm/ltr using AUTO-ROLLER and AIR-LESS PAINT SPRAYER complete all as specified and dircted by Engr-in-Charge.Note :- 1. The work shall be executed up to G+5th floor Height |
| 14 | Complete removal of existing treatment & levelling of wall/ceiling surface using MECHANICAL / ELECTRICAL OPERATED SANDING / SCRAPING MACHINE WITH INBUILT VACCUM SUCTION system to suck the existing treatment as retrieved by scrapping/sanding etc for obtaining smooth paintable surface and preparation of old surface 02 coats of Nanotechnology based Acrylic Regular Distemper, water based gives walls a smooth and matt finish and applied on prepared surface of wall & ceiling over a coat of approved nano primer @ 6.50 sqm/ltr using AUTO-ROLLER and AIR-LESS PAINT SPRAYER complete all as specified and dircted by Engr-in-Charge. |
| 15 | M&L for preparation of old steel surfaces of any description over 10cm width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 16 | M&L for preparation of old wooden surfaces of any description over 10cm width or girth and apply one coat of synthetic enamel paint complete all as specified and directed. |
| 17 | M&L preparation of surfaces by complete removal of existing treatment & applying two coats of Colour/White wash on walls complete all as specified & directed. |
| 18 | M&L for preparation new plastered surfaces of any description and applying three coat of white wash on ceiling surfaces complete all as specified and directed |
| 19 | M&L for complete removal and preparation old unplastered surfaces of any description and applying two coat of white wash on ceiling surfaces complete all as specified and directed |
| 20 | Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition complete all as specified and directed. |
| 21 | M&L for RCC 1:2:4 Type B-0 as in Chajjas, slab and the like complete all as specified and directed. |
| 22 | Use & Waste of formwork to Chajjas, soffits of slab ,chullah hoods, troughs and similar items including edges rough finished surfaces complete all as specified and directed. |
| 23 | S&F of TMT bars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 24 | M&L for dismentaling/demolition of RCC fins/parapets of any size incl. cutting down rusted reinforcement and makig good with CM 1:3 and provided drip course 25 mmx10 mm deep with CM 1:3 at edges of RCC slab/chajjas etc including necessary scaffolding arrangements complete all as specified and directed.Note:- Work Execute up to 5 floors heaight |
| 25 | Demolition of brickwork built in cement mortar including all quions, arches, pillars etc complete all as specified and as directed. |
| 26 | M&L brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius in CM 1:6 complete all as specified and directed. |
| 27 | S&F 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall including taking down existing pipe complete. |
| 28 | S&F 110mm dia PVC SWR bends of any radius with out access door complete all as specified and as directed Please Enable Macros to View BoQ information |
| 29 | S&F 110mm dia PVC SWR bends of any radius with out access door complete all as specified and as directed Please Enable Macros to View BoQ information |