| 1 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out soft/loose soil complete all as specified and directed. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 3 | M&L for PCC type D2, ( using 40mm graded aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 4 | M&L for Reinforced cement concrete (Design Mix, M-30) using 20mm graded aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.Note:- Reinforcement shall be measured separately. |
| 5 | M&L for Reinforced cement concrete (Design Mix, M-30) using 20mm graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed. Note:- Reinforcement shall be measured separately. |
| 6 | M&L for Reinforced cement concrete (Design Mix, M-30) using 20mm graded aggregate in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.Note:- Reinforcement shall be measured separately. |
| 7 | M&L for Reinforced cement concrete (Design Mix) M-30 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.Note:- Reinforcement shall be measured separately. |
| 8 | M&L for Reinforced cement concrete (Design Mix) M-30 as in Chajjas complete all as specified and directed by Engineer-in-Charge.Note:- Reinforcement shall be measured separately. |
| 9 | S&F Mild Steel TMT bars 10mm and over, cut to lenghth, bent to shape requird, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clip, complete all as specified and directed by Engineer-in-Charge. |
| 10 | All as per item No 09.00 here-in-before 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 11 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finihed surfaces complete all as specified and directed. |
| 12 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams for rough finished surfaces etc complete all as specified and directed. |
| 13 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and directed. |
| 14 | Formwork to Floor/Roof slabs incl Mumty slabs (Excl beams) for rough finished surfaces etc complete all as specified and directed. |
| 15 | Formwork to Chajjas for rough finished surfaces etc complete all as specified and directed. |
| 16 | M & L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 17 | M&L for Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of wall finsihed even and smooth with out using extra cement complete all as specified and directed. |
| 18 | M&L for Rendering 15mm thick in CM 1:4 using liquid waterproofing compound as per manufacturer instruction on fair faces of brick work or concrete surfaces of wall complete all as specified and directed. |
| 19 | Supply only Liquid water proofing compound, complete all as specified and directed by Engineer-in-Charge. |
| 20 | M&L for 5 mm thick rendering in CM (1:3) on brick or concrete surfaces on ceiling surface, complete all as specified and as directed. |
| 21 | M&L for Preparation of New or previously untreated surfaces of cement or plastered surfaces, of any description and girth, not otherwise described and applying 1mm thick wall care putty and chalk whitening primer on wall surface to achieve even and smooth surface and applying two coats of oil bound distemper on walls, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material & Labour preparing and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces incl 1 mm thick wall care putty complete all as specifeid and as directed. |
| 23 | M&L for preparation of new plastered surfaces of ceiling including cornices, pilasters etc and applying three coat of white wash, complete all as specified and directed. |
| 24 | Providing and fixing factory made uPVC white color Sliding window Two track made of extruded profiles with wall thickness of 2.3mm (+- 0.2mm). Window profile with hollow section with multi chamber, Frame (60mm x 62mm). sash (42mm x 67mm). Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm). Glazing bead (24.5mmx 16mm) will he mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel frame (30mm x 21.5mm), Sash (30mm x 18mm), profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : [Touch Lock of zinc alloyed (white powder coated), steel roller system including 5mm thick glazing with selected quality glass, aluminum track on bottom rail for two track sliding frame, wool pine for Sliding sash and interlock.] (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose) n exc 2.00 sqm each complete all as specified and as directed |
| 25 | Supply & fixing for frosted glass / tined glass 5.5 mm thick glazing in aluminium frames and ms pre coated frames, area not exc. 0.50 sqm in each pane, complete all as specified and directed. |
| 26 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed by Engineer-in-Charge. |
| 27 | S&F in 1.25 mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, an- choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete push pull or manual type gear operated type with bevel gear box and crank handle, complete all as specified and directed by Engineer-in-Charge. |
| 28 | M&L Hardcore broken stone or boulders of gauge n exc. 63mm, deposited, spread and leveliled in layers n exc. 150mm thick, watered and rammed to a true surface complete all as specified and directed. |
| 29 | M&L for 75mm thick Cement concrete type C- 2,1:3:6 (using 40mm graded stone aggregate) as in subbase of floor complete all as specified and directed. |
| 30 | M&L 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in floor for levelling course complete all as specified and directed by Egineer-in-Charge. |
| 31 | M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl 20 mm thick screed bed in CM (1:4) complete all as specified and as directed |
| 32 | M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including 10 mm thick rendering CM (1:3) complete all as specified and as directed. |
| 33 | M&L Non - skid Ceramic Coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry over screed bed or bedding layer of 15 mm thick with cement mortar 1:4 and pointed in white or coloured cement to match complete all as specified and directed. |
| 34 | M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry over 10 mm thick rendering with CM 1:4 and pointed in white or colour cement to match the colour of tiles complete all as speciified and directed. |
| 35 | S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed. |
| 36 | M & L for 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as spd and directed by Engr-In-Charge . |
| 37 | S&F factory made solid PVC door frame of size 50mmx47mm made out of 5 mm wood grain printed PVC shee twith mild steel square tube complete as per manufacturer specification & drawing complete all as specified and directed by Engr - in - Charge. |
| 38 | S&F factory made solid panel PVC door shutter 30 mm thick (stiles) consisting of frame made out of mild steel tubes for top & bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC \\"C\\" channel having a PVC sheet strip of 20 mm with stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap inserted for top rail and botttom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement fixing in the frame at site as per specification ,drawing complete all as specified and directed by Engr - in - Charge. |
| 39 | S&F 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed as specified and directed by engineer-in-charge. |
| 40 | Supply and fix 150 mm long aluminium anodised barrel tower bolt of extruded section and fixed complete all as specified and directed. |
| 41 | Supply and fix 150 mm aluminium handle cast type, anodised, complete all as specified and directed |
| 42 | S&F Vitreous China wash down water colset (Squat pattern) white complete as fixed in repair excluding flushing cistern and flush pipe \\"Orissa\\" pattern size 580x440 with integral footrest inject connection to trap antisyphonage etc complete incl joint between flushing pipe and coket of WC complete all as specified and directed. |
| 43 | S&F 10Ltr PVC valveless, syphonicaction type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed by Engineer-in-Charge. |
| 44 | Supply only Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern etc complete all as specified and directed |
| 45 | Supply & fix vitreous china wash basin, white, flat back, size, 550X400mm including bracket for fixing 32 mm waste coupling, waste pipe etc complete all as specifid and direted. |
| 46 | Supply and fix Pillar taps, 15mm bore, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'HOT or COLD' with long scrwed shanks and fly-nuts, screwed for iron pipe or for connection pipe, complete all as specified and directed. |
| 47 | S&F Bib taps of 15mm bore fancy type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule complete all as specified and directed. |
| 48 | S&F stop valve of 15mm bore , chromium plated with long shank and cup concealed type cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule complete all as specified and directed. |
| 49 | S&F PVC connection 15 mm size PTMT nuts of length ength 600 mm complete all as specified and directed |
| 50 | S&F soap dish vitreous china white size 160x160x90mm approx all as directed by Engineer -in-Charge |
| 51 | S&F 15 mm dia bore steel tubing medium grade galvanised with all fittings and connection complete all as specified and directed. |
| 52 | S&F 20 mm dia bore steel tubing medium grade galvanised with all fittings and connection complete all as specified and directed. |
| 53 | S&F 20mm bore gun metal glove or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed. |
| 54 | S& F 500 Ltr capcity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. |
| 55 | S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches/wall or in floors complete all as specified and directed. |
| 56 | S&F 110mm bore PVC (SWR) bends any radius with access door complete all as specified and as directed by EIC. |
| 57 | S&F PVC (SWR) junction double, (double T), equal or unequal complete all as specified and as directed. |
| 58 | S&F 110mm PVC (SWR) vent cowl, complete all as specified and directed by Engineer-in-Charge. |
| 59 | M&L for 75mm thick Cement concrete type C-1, 1:3:6 (20mm graded aggregate) as in plinth protection finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 60 | M&L for brushing neat cement slurry with 03 Kg of cement per Sqm, complete all as specified and directed by Engineer-in-Charge. |
| 61 | M&L for 15mm thick rendering in cement mortar (1:4) on fair faces of brickwork or concrete surfaces with water proofing compound @ 3% by the weight of cement as per manufacturer's instructions finished even and smooth without using extra cement, complete all as specifed and as directed. |
| 62 | Supply only integral water proofing compound, complete all as specified and directed. |
| 63 | M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application including coating the surface with waterbased bituminous primer blow bitumen of 85/25 or 90/15 at 1.2 kg/sqm at bottom of the membrane incl primering the surface and applying normal treatment, complete all as specified and directed by Engineer-in-Charge. |
| 64 | Returning, filling in and including spreading, leveling, watering & well ramming in layers n.exceeding 25 cm in soft/loose soil, complete all as specified and directed. |
| 65 | Removing of excavated materials to a distance n. exc 50m and depositing where directed at a level n exc 1.5m above the starting point in soft/loose soil complete all as specified and directed by Engineer-in-Charge. |
| 66 | Excavation over area, not exc 1.5m deep for laying foundation etc in soft/loose soil and getting out, complete all as specified and directed by Engineer-in-Charge. |
| 67 | Excavation over area, exc 1.5m but not exc 3.00m deep for laying foundation etc in soft/loose soil and getting out, complete all as specified and directed by Engineer-in-Charge. |
| 68 | M&L PCC 1:3:6 type C-2 ( with using 40mm graded stone aggregate) in foundation filling and mass concrete, complete all as specified and directed |
| 69 | M &L for RCC M-30 (design mix) using 20mm graded stone aggregate, as in wall retaining wall, basement walls ,ballast walls and the like any thickness above top of footings including attached pilasters and buttresses, complete all as specified and directed by Engineer-in-Charge. |
| 70 | Formwork to faces of walls,retaining walls, abutments,parapets and staircase railings and similar work including attached pillasters, buttresses,etc.; vertical or to batter complete all as specified and directed. |
| 71 | M&L for preparation of new decorated plastered surfaces of wall including cornices, pilasters etc and applying three coat of white wash complete all as specified and directed. |
| 72 | M&L for 75 mm thick cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in plinth protection finished even and smooth without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 metres and every change of direction and filling the same with & including bitumen and sand 1:3 by weight of grade 'A' complete with and including necessary form work etc complete all as specified and as directed. |
| 73 | M &L for RCC M-30 (design mix) using 20mm graded stone aggregate, as in foundation including raffs footing, foundation beams, plinth beams for column etc complete all as specified and directed. |
| 74 | Earth work excavation (by mechanical means- Hydraulical excavator) in foundation trenches n.exc 1.5m wide & n exc 1.5 m in depth for foundation etc including getting out in all kinds of soil and disposal of excavated earth upto 50m, complete all as specified and directed by Engineer-in-Charge. |
| 75 | M & L for Plain Cement Concrete Type C2 1:3:6 ( using 40 mm graded granite stone aggregte) in foundations, filling and mass concrete, complete all as specified and directed by Engineer-in-Charge. |
| 76 | M&L for Pre-cast cement concrete solid block masonry with grade C5 solid units having density not less than 1800 kgs/Sqm as per IS 2185 Pt-I built in CM 1:6, exc 10cm in width and setting in mortar, complete all as specified and directed. |
| 77 | M & F for Plain cement concrete type B1 1:2:4 ( using 20 mm graded granite stone aggregate) copings, bed plates and the like including weathering, slightly, complete all as specified and directed by Engineer-in-Charge. |
| 78 | M&L for 15 mm thick rendering on brick masonry/concrete surfaces in cm 1:4 including finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. |
| 79 | Removing of excavated material exc 50 m but n exc 250m and depositing, complete all as specified and directed by Engineer-in-Charge. |
| 80 | Removing excavated material exc. 250 m but n exc. 500 m and depositing, complete all as specified and directed by Engineer-in-Charge. |
| 81 | M & L for hardcore of gauge exc. 63 mm but n exc 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 82 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate 75 mm thick as in sub base, complete all as specified and directed |
| 83 | M&L for sand cushion for fixing of inter locking tiles, complete all as specified and directed. |
| 84 | M&L for Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade, approved colour, complete all as specified and directed by Engineer-in-Charge. |
| 85 | M & L for precast cement concrete type 'B-1' 1:2:4mm (using 20mm graded aggregate) solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar 1:4, complete all as specified and directed. |
| 86 | M&L for cement concrete (1:4:8) type D2 using 40mm graded stone agg) as in foundation filling and mass concrete, complete all as specified & directed. |
| 87 | M &L for RCC M-30 (design mix) using 20mm graded stone aggregate, as in foundation including raffs footing, foundation beams, plinth beams for column etc, complete all as specified and directed. |
| 88 | M &L for RCC M-30 (design mix) using 20mm graded stone aggregate, as in columnss, pillars,piers,post and struts, complete as as specified and directed. |
| 89 | M &L for RCC M-30 (design mix) using 20mm graded stone aggregate, as in beam ,lintels & tie beam etc, complete as as specified and directed. |
| 90 | M&L for random rubble masonry work brought up to course solidly hearted in cm (1:6), complete all as specified and directed by Engineer-in-Charge. |
| 91 | M & L 15 mm thick rendering on fair faces of brick work/concrete surfaces in cement mortar 1.4, surface finished even and fair without using extra cement, complete all as specified and directed. |
| 92 | S & F mild steel as in posts, struts, etc in fencing including cutting tops to shape as directed drilling holes notching for wire etc, flat iron filets, MS plate etc (for Security wire etc) including all necessary drilling, botting or reveting etc and similar work confirming to Fe-290 Gde E-165, complete all as complete and directed. |
| 93 | S&F galvanised 2 strand steel barbed wire 2.24m dia barbed with 2mm dia barts at 75mm spacing and straiing and fixing to any type of standard rails, including straining bolts, including security or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc, complete all as specified and directed. Note- Each line of wire shall be measured separately. |
| 94 | S&F Helix concertina coil 0f 600mm dia meter including 'U' clip & 'C' clip (bebore stretch) having 50 numbers of spirais & composed of reinforced punched barbed tape (RPBT) wire having continous punched blade edged barbs on both sides of coil rolled low carbon steel to centre pitch 36mm alongwith flattened strip width of 18.60mm and centre width 7.40mm. The barbs should have 180 degree straightness with razor edge cut. The razor tape should have minimum galvanising coating thickness of 12 microne (both sides inclusive). The core wire should have minimum wire dia meter 2.59mm and tensile strength of 1620 N/Sqmm. All the materials should be coated by dipping process with anti corrosive black bitumineous paint conforming to IS-168. The length of coil should be 8 mtr stretch per coil. The concertina coil should be as per relivent IS, complete all as specified and directed by Engineer-in-Charge. |
| 95 | S&F PVC pipe 75mm dia single socketed in any length fixed in wall as weep holes etc, complete all as specified and directed. |
| 96 | M & L for Preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of primer on wall, complete all as specified and as directed by Engr-in-Charge |
| 97 | M&L for preparing new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed |
| 98 | M&L for crushed stone dust under foundation spread levelled and rammed including watering and consolidating, complete all as specified and as directed. |
| 99 | S&F 285 gsm non wooven geo textile cloth of approved make to be approved by GE and placing in position, complete all as specified and as directed. |
| 100 | M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of Fe 410-W (Gde E250) quality-B, complete all as specified and directed by Engineer-in-Charge. |
| 101 | Material and labour for point wiring complete with 2.5 sqmm FR PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core in conceled PVC conduit pipe of minimum 20 mm size complete including suitable size of 1 to 8 module metal flush box, modular front plate as per site requirenment for mounting modular switch/ sockets regulators etc.and with 2.5 sqmm FR PVC insulated copper conductor earth wire and connected to earth dolly for one light/ fan point controlled by one switch, complete all as specified and as directed by Engineer-in-charge. |
| 102 | All as per serial item No. 101.00 above but for 3 pin socket outlet point controlled by one, one way switch on the same board.(one circuit with maximum 8 points (not more than 2X6A sockets in one circuit). |
| 103 | All as per serial item No. 101.00 above but for one 3 pin switch socket combination of 5 Amp capacity on independent board but wire of size 2.5 sqmm (one circuit with maximum 4 points) |
| 104 | All as per serial item No. 101.00 above but for 3 pin switch socket combination of 15 Amp on independent board with cable 4 sqmm unsheathed stranded 1100 Volts grade complete with 4.0 sqmm FR PVC insulated earth wire and connecting to earth dolly complete all as specified and as directed by Engineer-in-charge.(one circuit with one point only) |
| 105 | S&F modular switch one way 6 Amps , 1 module type, complete all as specified and directed by Engineer-in-Charge. |
| 106 | S&F modular socket , 6 Amps , 2/3 pin combined 2 module, complete all as specified and directed by Engineer-in-Charge. |
| 107 | S&F modular switch socket combination, 6 Amps / 16 Amps , 2/3 pin combined 2 module, complete all as specified and directed by Engineer-in-Charge. |
| 108 | Supply and fix ceiling rose surface backelite three terminal complete all as specified and as directed by Engineer-in-charge. |
| 109 | Supply and fix MCB SPN 240 Volts 32 Amp breaking capacity 10 KA rating complete all as specified and as directed by Engineer-in-charge. |
| 110 | Supply and fix MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating, complete all as specified and as directed by Engineer-in-charge. |
| 111 | Supply and fix sheet metal enclosure powder painted for MCB SPN 12 way DB double door with din rail and bus bar including making good to the disturbed surface matching with the existing, complete all as specified and as directed by Engineer-in-charge. |
| 112 | Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting upto PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirement and 2 Nos of round or square PVC bolck for fixing of FTL fitting, complete all as specified and directed by Engineer-in-Charge. |
| 113 | Supply and fixing ceiling fans complete with blades, down rods, electronic modular fan regulator for speed control and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value greater than equal 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and directed by Engineer-in-charge. |
| 114 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450m sweep with, blades, and frame and louvers complete all as specified and directed. |
| 115 | Supply and fix LED street light fitting 35 Watt 230 V AC with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection fixed on pole complete inccluding all fixing arrangments, complete all as specified and directed by Engineer-in-Charge. |
| 116 | M&L for Earthing complete with galvanised steel earth plate electrode 600 ×600× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and directed by Engineer-in-Charge.Note :-(i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.(ii) Earthing lead and GI protection pipe up to the DB is included in the quoted price. |
| 117 | Supply and fix in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 16 sqmm 2 core complete all as specified and directed |
| 118 | Supply and laying GI tube light grade 50 mm bore, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 119 | Supply and laying GI tube light grade 50 mm bore, complete all as specified and directed. Please Enable Macros to View BoQ information |