| 1 | Taking down carefully surface aluminium point wiring with wooden battens / PVC conduit (light, fan, socket, bell or power) including fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators etc and making good disturbed surfaces complete all as specified and as directed by Engr-in-Charge. |
| 2 | M&L for point wiring with 1.5 Sqmm single core PVC insulated unsheathed copper multi stranded conductor including PVC rigid non metallic concealed Conduit of size 19/20 mm ISI marked as per site requirement inclusive of tees, bend, elbows etc including modular sunken steel box as per IS specification concealed in wall for housing for modular switch socket etc with modular plate with frame of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm as earth wire to common earth dolly for connection to ceiling rose to earth terminal incl cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed at site.(a) One light point controlled by one switch complete all as specified and directed. |
| 3 | (b) Ceiling fan/Exhaust fan point controlled by one switch complete all as specified and directed. |
| 4 | (c) One Bell point controlled by one switch complete all as specified and directed. |
| 5 | (d) One 3/5 pin switch socket 5/6 Amps on Independent board complete all as specified and directed. |
| 6 | (e) One 3/5 pin switch socket 5/6 Amps on same board complete all as specified and directed. |
| 7 | M&L for point wiring with 4 Sqmm PVC insulated and unsheathed FRLS single core multistranded copper conductor point in and including PVC rigid non metalic concealed conduit 19/20mm dia, medium duty, ISI marked to be teminated in pressed steel terminal boxes including 4 Sqmm PVC inslulated and unsheathed FRLS single core multistranded copper earth continuity conductore controlled by one witch and / or one regulator complete for following items complete all as specified and as directed by Engr-in Charge. |
| 8 | M&L for point wiring complete with PVC insulated unsheathed FRLS multistranded copper conductor cable conforming to IS : 694 of size 1.5 Sqmm Two single core drawn through in and including suitable size PVC casing capping ISI Marked complete with one run of PVC insulated copper conductor cable 1.5 Sq mm single core green colour earth wire and connecting to earth dolly including colour coding of cable shall be for phase, neutral and earth wire as specified in MES SSR Part I 2009 with provision of sunken galvanised not less than 1.12 mm thick MS sheet pressed terminal boxes concealed on wall, with 3 mm thick laminated sheet top cover ISI marked for fixing of switches/socket/regulator with screws complete including making good of disturbed surfaces of wall/ceiling/floor in same specification as per existing all as specified and directed. (a) One light/bell point controlled by one switch complete all as specified and directed. |
| 9 | One fan point controlled by one switch complete all as specified and directed. |
| 10 | One 5 amps switch socket combination on independent board complete all as specified and directed. |
| 11 | One 5 amps socket outlet on same board controlled by another switch complete all as specified and directed. |
| 12 | All as per item No. 4 (here in before) but with 2.5 Sqmm PVC insulated unsheathed FRLS multistranded copper conductor cable conforming to IS : 694 for power point complete all as specified and directed. |
| 13 | Supply and fix switch piano flush type, 5 Amps 240 volts single pole one way complete all as specified and directed by Engr-in-Charge. |
| 14 | S&F switch socket combination 2 in 1, 5 amps flush type complete all as specified and directed by Engr-in-Charge. |
| 15 | S&F socket outlet, 5 pin 5amps, flush type complete all as specified and directed by Engr-in-Charge. |
| 16 | S&F switch socket combination 5/15 amps, 5 in 1, flush type complete all as specified and directed by Engr-in-Charge. |
| 17 | S&F fan regulator electronic type, step type, 240 Volt complete all as specified and directed. |
| 18 | S&F ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body complete all as specified and directed. |
| 19 | S&F in repair Bell push flush type, 5 Amps complete all as specified and directed. |
| 20 | S&F in replacement Modular switch piano flush type, single pole, one way, 6 Amp 230 volts all as specified and directed. |
| 21 | S&F in replacement Modular switch piano flush type, single pole, one way, 16 Amp 230 volts all as specified and directed. |
| 22 | S&F in replacement Modular Socket, single pole, one way, 16 Amp 230 volts all as specified and directed. |
| 23 | S&F in replacement Modular Socket, single pole, one way, 6 Amp 230 volts all as specified and directed. |
| 24 | S&F in replacement Modular Bell push , one way, 6 Amp 230 volts all as specified and directed. |
| 25 | Supply & fixing Bell ding dong type, AC 230 volts all as specified and directed. |
| 26 | Supply & fixing Lamp holder insulated body with back plate batten/angle type for batten fittings complete all as specified and directed. |
| 27 | Supply and fixing LED bulb of capacity 9/10 W complete all as specified and as directed. |
| 28 | S&F in replacement Modular ceiling rose three terminals, ISI complete all as specified and directed. |
| 29 | Supply and fixing in repairs surface and wall mounted LED light batten fitting energy efficient of 20 watt, including LED light, provision of PVC insulated sheathed round flexible wire with multi strand copper conductor of size 1.5 sqmm 3 core 1100 Volts grade all as specified and directed. |
| 30 | Supply and fixing in replacement Only LED Batten CRCA sheet box type fixture 4 feet,long Single Side Connection suitable for 18/20w LED tube light Rod with G13 lamp holders. Complete with Mounting Brackets & accessories as required with connections, complete all as specified and as directed. |
| 31 | Supply and Fixing in replacement LED tube rod only having aluminium extrusion 18W, 4ft for existing tubelight fitting complete all as specified and directed. |
| 32 | Supply & Fixing LED tube light fitting complete 1X9 (2Feet long) polycarbonate batten including LED tube,complete all as specified and directed. |
| 33 | Supply and Fixing in replacement modular ceiling fan regulator electronic step type of suitable wattage 230V suitable for 1200/1400 mm sweep ceiling fan etc complete all as specified and directed. |
| 34 | S & F sheet metal enclosure MCCB VTPN 4 way with 200 amps rated bus bar 415 volts double door with isolated Neutral bar & Shrouded bus bar IP protection 43 having door earthing complete, including taking down old U/s MCB complete all as specified and directed. |
| 35 | Supply and fix MCCB 125 Amps, breaking capacity 16KA complete all as specified and directed by Engr-in-charge. |
| 36 | Supply and fix MCB Single pole 6 to 32 Amps, breaking capacity 10 KA (Type ' B' ) complete all as specified and directed by Engr-in-charge. |
| 37 | Supply and fix MCB SPN 40 Amps, breaking capacity 10 KA (Type ' B' ) complete all as specified and directed by Engr-in-charge. |
| 38 | Supply and Fix of MCB SPN , 8 way with 200 amps rated bus bar 240 volts double door with isolated Neutral bar & Shrouded bus bar IP protection 43 having door earthing complete all as specified and directed by Engr-in-charge. |
| 39 | Supply and draw submain wiring with two single core 6 sqmm FRLS PVC insulated copper cable 1100 volts grade multistranded, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 6 sqmm multi strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete after taking down the old unserviceable wiring complete all as specified and directed. |
| 40 | Supply and draw submain wiring with two single core 4 sqmm FRLS PVC insulated copper cable 1100 volts grade multistranded, unsheathed conductor drawn into PVC casing and capping and all necessary fittings including 4 sqmm multi strand FRLS PVC insulated copper wire for earth continuity conductor connected to common earth dolly complete after taking down the old unserviceable wiring complete all as specified and directed. |
| 41 | M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I and including necessary excavation and earth work in any type of soil, removal and refilling of soil and funnel with wire mesh and GI watering pipe 20mm dia, Chamber in PCC 1:3:6, type C1 using 20mm graded stone aggregate and 40mm thick cover in RCC 1:2:4, type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 150mm c/c on both ways, handle with 16mm dia round bars and 15mm dia GI pipe upto 7.5m for protection and connected to earthing test point all as specified or indicated including testing on completion. Note:- (i) GI earth lead wire upto 7.5m shall be measured and paid. (ii) PCC chamber shall be provided 50cm away from the plinth of building. |
| 42 | Supply & fixing in replacement LED street light luminaries of capacity 25 watt, SPD-10KV internal with lense, 240 volt, pressure dia cast aluminium housing frame, heat resistant toughened clear glass with frame complete with accessories, IP 66 protection, pre wired up to a terminal block and mounting attachment, including pvc connector for connection complete all as specified and directed. |
| 43 | Supply and fix in repairs street light bracket made out of 25 mm bore galvanised iron, light grade (approx 1.5 mtr in length) including necessary two nos suitable size of clamp with nuts, bolts and washers, etc and two costs of synthetic enameled paint over a coat of red oxide primer complete all as specified and directed. |
| 44 | Supplying and fixing in repair/replacement 1100 volts grade heavy duty cable PVC insulated aluminium stranded/Solid conductor, served with inner sheathing of PVC sheathed wire, one twin core cable flat or circular of 6 sqmm complete all as specified and directed. |
| 45 | Supply and Fixing modular cover plate with frame, 1 module complete all as specified and directed. |
| 46 | Supply and Fixing modular cover plate with frame, 2 module complete all as specified and directed. |
| 47 | Supply and Fixing modular cover plate with frame, 3 module complete all as specified and directed. |
| 48 | Supply and Fixing modular cover plate with frame, 4 module complete all as specified and directed. |
| 49 | Supply and Fixing modular cover plate with frame, 6 module complete all as specified and directed. |
| 50 | Supply and Fixing modular cover plate with frame, 8 module complete all as specified and directed. |
| 51 | Supply and Fixing modular metal flush box 1/2 module complete all as specified and directed. |
| 52 | Supply and Fixing modular metal flush box 3 module complete all as specified and directed. |
| 53 | Supply and Fixing modular metal flush box 4 module complete all as specified and directed. |
| 54 | Supply and Fixing modular metal flush box 6 module complete all as specified and directed. |
| 55 | Supply and Fixing modular metal flush box 8 module complete all as specified and directed. |
| 56 | Supply and Fixing in replacement LED light fitting wall mounted decoretive Monarc Wall complete all as specified and directed. |
| 57 | Supply and Fixing in replacement LED light fittings 36 Watt Recess Mounting type, with mounting arrangement (Recess suitable for, 2x2 Grid, Hanging) Sheet aluminium housing with high quality LGP and PMMA diffuser, Separate HPF driver suitable for Armstrong and grid ceiling LED 240 volt along with fixing arrangements all as directed. |
| 58 | Supply and fix in repair sheet metal enclosures with socket plug top and MCBs single pole and neutral enclosure with a 2 pin and earth plug and socket complete with one SP MCB of 16 Amp rating 240 Volt complete all as specified and directed .( Geyser & AC) Please Enable Macros to View BoQ information |