| 1 | Rewiring Group C for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 2 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.20mm |
| 3 | 25 mm |
| 4 | Wiring for circuit/ submain wiring along-with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 16 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm |
| 6 | 3 x 4 sq. mm |
| 7 | Supplying and fixing following modular type switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 8 | 15/16 A switch |
| 9 | 3 pin 5/6 A socket outlet |
| 10 | 6 pin 15/16 A socket outlet |
| 11 | Bell Push |
| 12 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 13 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as requiredSingle Pole |
| 14 | Double Pole |
| 15 | Triple Pole and Neutral |
| 16 | Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 17 | Supplying and fixing 16 Way Double Door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 18 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 19 | Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required. |
| 20 | Supplying and fixing 63 Ampere four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 21 | Supply of 200 mm sweep Exhaust-fan with 100% copper motor rotating at min. 1000 RPM complete in all respect in PVC Body i/c 10% less rebate for dismantled material. |
| 22 | Installation, Testing and Commissioning of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required |
| 23 | Extra for fixing the louvers/shutters complete with frame for a exhaust fan of all sizes. |
| 24 | Supply of 1200mm, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm,suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req. i/c 10% less rebate for dismantled material. |
| 25 | Supply of 10 Watt 2 Feet LED Batten having polycarbonate body with IP 20 Rating, Driver Efficiency >= 88%, minimuum 100 lm/W efficacy & 4 kV Built-in Surge Protection working on 140 V AC - 270 V AC, 6500 K, 50 Hz supply including connection, testing as required. |
| 26 | Supply & Installation of Wall-mounted RO+UV+UF+TDS Control Kent-make Water Purifier having min. 20 L/hr flow-rate and min. 8 Litre Storage Capacity working at 230 V 50 Hz supply with minimum 1Year Brand Warranty i/c connections, fittings etc. complete as required. |
| 27 | Supplying, Installation, Testing & Commissioning of 36 Watt Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P.F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 28 | Supply & Installation of 2 HP Rated ISI-marked Monoblock Centrifugal-type Pump working on single phase supply of 230 Volt, 50 Hz supply with suction & delivery of 25 mm X 25 mm (using reducer etc.) running at 2800-2900 RPM having head 20 - 30 metre against discharge of 3.5 - 2 lps and with CI Impeller, Steel Shaft and Mechanical Sealing etc. with all fittings & connection like reducer, nipple, bends,elbows,tee etc. complete as required & having 1 year warranty. |
| 29 | Supplying, Installation, Testing & Commissioning of following power LED Recessed/Surface Down lighter (Round / Square/ Rectangular) COB i.e. Chip-On-Board Type Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) |
| 30 | 5 - 7 watt |
| 31 | 22 watt |
| 32 | Supply and Installation of Powder Fire Extinguisher (Stored Pressure type) Capacity 06 Kg duly ISI marked conforming to IS: 15683:2018, with IS 4308, ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual and bracket. Operating Temperature: -30°C to + 60°C etc. complete as required i/c 10% less rebate for dismantled material. |
| 33 | Supply and Installation of CO2 type Fire Extinguisher Capacity 4.5 Kg duly ISI marked conforming to IS: 15683 complete with delivery hose horn, wheel type release valve, locking arrangement, operation manual and bracket. Operating Temperature:- 30°C to +60°C etc. complete as required i/c 10% less rebate for dismantled material. |
| 34 | Supply & Installation of Direct-Cool type Single Door Refrigerator with minimum capacity 180 ltr. with digital inverter compressor having minimum 20 year brand warranty i/c all minor sparts etc. complete as required |
| 35 | Supplying, Installation, Testing & Commissioning of Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) 18-22 Watt LED Batten surface light (System lumen efficacy >135 lm/Watt) as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Please Enable Macros to View BoQ information |